Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microchannel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Construction of a Compact Array of Microplasma Jet Devices and Its Application for Random Mutagenesis of Rhodosporidium toruloides

A small and efficient DNA mutation-inducing machine was constructed with an array of microplasma jet devices (7 × 1) that can be operated at atmospheric pressure for microbial mutagenesis. Using this machine, we report disruption of a plasmid DNA and generation of mutants of an oleaginous yeast Rhodosporidium toruloides. Specifically, a compact-sized microplasma channel (25 × 20 × 2 mm 3 ) capable of generating an electron density of greater than 10 13 cm –3 was constructed to produce reactive species (N 2 *, N 2 +, O, OH, and H α ) under helium atmospheric conditions to induce DNA mutagenesis. The length of microplasma channels in the device played a critical role in augmenting both the volume of plasma and the concentration of reactive species. First, we confirmed that microplasma treatment can linearize a plasmid by creating nicks in vitro. Second, we treated R. toruloides cells with a jet device containing 7 microchannels for 5 min; 94.8% of the treated cells were killed, and 0.44% of surviving cells showed different colony colors as compared to their parental colony. Microplasma-based DNA mutation is energy-efficient and can be a safe alternative for inducing mutations compared to conventional methods using toxic mutagens. In conclusion, this compact and scalable device is amenable for industrial strain improvement involving large-scale mutagenesis.

59 BASIC BIOLOGICAL SCIENCES↗

Low cost and massively parallel force spectroscopy with fluid loading on a chip

Current approaches for single molecule force spectroscopy are typically constrained by low throughput and high instrumentation cost. Herein, a low-cost, high throughput technique is demonstrated using microfluidics for multiplexed mechanical manipulation of up to ~4000 individual molecules via molecular fluid loading on-a-chip (FLO-Chip). The FLO-Chip consists of serially connected microchannels with varying width, allowing for simultaneous testing at multiple loading rates. Molecular force measurements are demonstrated by dissociating Biotin-Streptavidin and Digoxigenin-AntiDigoxigenin interactions along with unzipping of double stranded DNA of varying sequence under different dynamic loading rates and solution conditions. Rupture force results under varying loading rates and solution conditions are in good agreement with prior studies, verifying a versatile approach for single molecule biophysics and molecular mechanobiology. FLO-Chip enables straightforward, rapid, low-cost, and portable mechanical testing of single molecules that can be implemented on a wide range of microscopes to broaden access and may enable new applications of molecular force spectroscopy.

42 ENGINEERING↗

Time-resolved RIXS experiment with pulse-by-pulse parallel readout data collection using X-ray free electron laser

Abstract Time-resolved resonant inelastic X-ray scattering (RIXS) is one of the developing techniques enabled by the advent of X-ray free electron laser (FEL). It is important to evaluate how the FEL jitter, which is inherent in the self-amplified spontaneous emission process, influences the RIXS measurement. Here, we use a microchannel plate (MCP) based Timepix soft X-ray detector to conduct a time-resolved RIXS measurement at the Ti L 3 -edge on a charge-density-wave material TiSe 2 . The fast parallel Timepix readout and single photon sensitivity enable pulse-by-pulse data acquisition and analysis. Due to the FEL jitter, low detection efficiency of spectrometer, and low quantum yield of RIXS process, we find that less than 2% of the X-ray FEL pulses produce signals, preventing acquiring sufficient data statistics while maintaining temporal and energy resolution in this measurement. These limitations can be mitigated by using future X-ray FELs with high repetition rates, approaching MHz such as the European XFEL in Germany and LCLS-II in the USA, as well as by utilizing advanced detectors, such as the prototype used in this study.

36 MATERIALS SCIENCE↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Multi-layering of SU-8 exhibits distinct geometrical transitions from circular to planarized profiles

The negative tone photoresist SU-8 permits the creation of micrometer-scale structures by optical lithography. It is also the most used photoresist in soft lithography for the fast-prototyping of microfluidic devices. Despite its importance, the effect of capillary forces on SU-8 multi-layering onto topographical features has not been thoroughly studied. In particular, the profile of the added layer has not been examined in detail. The overlaying process exhibits a set of distinct behaviors, or regimes, depending on the relative thickness of the overlay and the underlying rectangular pattern. We demonstrate how capillary effects control the profile of multi-layer microchannels in a predictable manner. We derive a simple static model to describe the evolution of the overlay as a function of dimensionless geometric parameters. Our study provides a critical understanding of the parameters that govern multi-layer spin coating.

Sauzade, Martin↗

Plasma temperature measurement with a silicon photomultiplier (SiPM)

The temperature of a nonneutral plasma confined in a Penning–Malmberg trap can be determined by slowly lowering one side of the trap’s electrostatic axial confinement barrier; the temperature is inferred from the rate at which particles escape the trap as a function of the barrier height. In many experiments, the escaping particles are directed toward a microchannel plate, and the resulting amplified charge is collected on a phosphor screen. The screen is used for imaging the plasma but can also be used as a Faraday cup (FC) for a temperature measurement. The sensitivity limit is then set by microphonic noise enhanced by the screen’s high-voltage bias. Alternately, a silicon photomultiplier (SiPM) can be employed to measure the charge via the light emitted from the phosphor screen. This decouples the signal from the microphonic noise and allows the temperature of colder and smaller plasmas to be measured than could be measured previously; this paper focuses on the advantages of a SiPM over a FC.

Hunter, E. D. (ORCID:0000000236242840)↗

Guiding light via slippery liquid-infused porous surfaces

Slippery liquid-infused porous surfaces (SLIPSs) have been explored for many applications, taking advantage of their highly non-wetting property. In this work, we explore the SLIPS as a cladding material for waveguiding. SLIPSs are prepared by infusing perfluoropolyether oil to hydrophobized nanoporous surfaces of silicon. Power loss and transmission efficiency of an HeNe laser (1.82 mW and 632.8 nm) with varying incident angles were measured through microchannels consisting of the SLIPSs as cladding layers (noil = 1.30) and water (nwater = 1.33) as a core, compared to other cladding types including a planar silicon surface and the nanoporous surfaces in hydrophilic (Wenzel state) and hydrophobic (Cassie–Baxter state) conditions with no oil infused. Agreeing with Snell's law, a total internal reflection occurs at the incident angle as high as 14° for the SLIPSs. The waveguide loss at 14° is only 1.8 dB/cm for the SLIPSs, while those for planar silicon, hydrophilic nanoporous, and hydrophobic nanoporous surfaces are 5.9, 7.4, and 4.9 dB/cm, respectively. The power transmission efficiency of the SLIPSs is independent of the porosity because the surfaces are fully covered with the oil layer, whereas those of hydrophilic and hydrophobic nanoporous surfaces, whose pores are filled with water and air, respectively, depend on the porosity. The significantly lower power loss and the insensitivity to the surface porosity are advantages of the SLIPSs over the other surfaces and can benefit in waveguiding applications such as optofluidics.

Asawa, Kaustubh (ORCID:0000000197142555)↗

Slicing Newton spheres with a two-camera 3D imaging system

We demonstrate a simple approach to achieve three-dimensional ion momentum imaging. The method employs two complementary metal–oxide–semiconductor cameras in addition to a standard microchannel plates/phosphor screen imaging detector. The two cameras are timed to measure the decay of luminescence excited by ion hits to extract the time of flight. The achieved time resolution is better than 10 ns, which is mainly limited by camera jitters. A better than 5 ns resolution can be achieved when the jitter is suppressed.

Chemistry↗

High-temperature oxidation of transient-liquid phase bonded Ni-based alloys in 1 bar and 250 bar carbon dioxide

Compact microchannel heat exchanger designs for supercritical CO 2 power cycles are valued for equipment size reduction and increased heat transfer. They can be fabricated via transient-liquid phase (TLP) bonding, which utilizes a lower melting point interlayer for bonding facilitation of etched thin plates. Haynes 230 and 282 TLP bonded stacks were exposed to high-purity CO 2 at 1 bar/700 °C to 4000 h and 250 bar/720 °C (supercritical) to 1500 h. All samples obeyed parabolic kinetics after an oxide buildup stage of 500-1000 h. Mass gains were similar for the base and TLP bonded alloys, and oxide thicknesses and scales did not significantly differ around the TLP bond regions. Furthermore, there were some slight oxide compositional differences for the H282 TLP samples at 250 bar. There was a slight pressure effect on mass gain, as samples exposed at the higher pressure experienced higher initial mass gains, but then slower continued oxide growth.

36 MATERIALS SCIENCE↗

Microfluidic cells for the 1–10 2 MPa pressure range

Thin membrane-delimited fluid cells supporting up to 1 at (0.1 MPa) of pressure are well known and commercially available for use in vacuum chambers of electron, photon, or various particle beam microscopies or spectroscopies. Hereby, we report on the development of fluid cells capable of working at 1–10 MPa, extending the analysis domain for investigating chemical, biochemical, or physical processes at pressures of interest in chemical synthesis, underwater biochemistry studies or underground geology. We explored ways to optimize cell membranes to better resist pressure beyond simply increasing the thickness or decreasing the size of the membranes, using finite element analysis and experimental validation via membrane bulging experiments and failure statistics. Fluid cell prototypes were fabricated using ∼75 nm-thick SiN x membranes, engineered to withstand 4.7 MPa (average value), compared to regular (un-engineered) membranes withstanding only 3.4 MPa (average value). The fluid cell prototypes include eight microchannels for feeding/evacuating the fluids and applying pressure into micro-reaction chambers, two electrodes for electrochemical or conduction measurements in the sample, and a possible pressure or temperature sensor, customizable for specific experiments.

hi-pressure↗

Study of SXR/EUV radiation of exploded foils and wires with spectral, spatial and temporal resolution simultaneously on KING electric discharge facility.

The results of studies of the soft X-ray and extreme ultraviolet (SXR/EUV) radiation of thin flat aluminum foils and wires under the explosion in an electric discharge on the compact high-current KING generator are presented. These studies were based on the SXR/EUV spectroscopy with a spectral resolution of 6 Å, a temporal resolution of 5 ns and a spatial resolution of 200 μm. To study the plasma radiation of exploded foils and wires in the SXR/EUV range, we used a transmission diffraction grating spectrograph which in combination with two additional slits provided spectral and spatial resolution. The spectrograph was coupled with a 4-frame recorder based on a microchannel plate for providing temporal resolution. The analysis and comparison of the spectral, spatial, temporal, and energy characteristics of the SXR/EUV radiation of plasma formed under the explosion of foils and wires of a similar mass made of aluminum was carried out. Here, the spectra were calculated as well and the plasma parameters and their changes in time and space were estimated on the basis of these calculations and comparison with relevant experimental results. Experiments have shown that when foils explode, a single intense source of SXR/EUV radiation is formed with radiated energy in the range of 10-20 J and a power of up to 100 MW in the quantum energy range from 30 to 250 eV. At the same time, the radiation power under the explosion of foils turned out to be about twice above the power under the explosion of wires of comparable mass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coupling of electroelastic dynamics and direct contact ultrasonic drying formulation for annular piezoelectric bimorph transducers

A newly developed technique for drying clothes without thermal energy has been developed through the utilization of ultrasonic vibrations from piezoelectric transducers. The novel technique incorporates the actuation of a thin stainless steel disk in contact with wet fabric via annular piezoelectric rings, where water in the liquid form is atomized, transported through microchannels in the disk, and ejected as a mist. In such a system, resonance matching between the actuation portion of the transducer and the portion contacting fabric must be realized, with theoretical results from the developed electromechanical model showing a reduction in energy consumption by 50% when resonance matching is achieved. The electrically coupled distributed parameter model for an annular bimorph piezoelectric transducer is developed for optimization of ultrasonic drying technology. The thickness mode vibrations are shown to dominate the behavior of the system, where the analytically developed model can be optimized to increase the output acceleration of the transducer, thus increasing drying performance. Here, the electromechanical equation developed will be connected to the drying rates of fabrics in contact with said vibrations, where the novelty of the coupled equations and its description of the physics of ultrasonic drying will be discussed.

36 MATERIALS SCIENCE↗

Advances in the Large Area Picosecond Photo-Detector (LAPPD TM ): 8" × 8" MCP-PMT with Capacitively Coupled Readout

Abstract We present advances made in the Large Area Picosecond Photodetector (LAPPD), an 8" × 8" microchannel plate photomultiplier tube (MCP-PMT), since pilot production was initiated at Incom, Inc. in 2018. The Gen-I LAPPD utilizes a stripline anode for direct charge readout. The novel Gen-II LAPPD employs an internal resistive thin-film which capacitively couples to a customizable external signal readout board, streamlining production and increasing customer flexibility. The Gen-II LAPPD, with an active area of 373 cm 2 , is capable of high single photoelectron (PE) gain of ∼10 7 , low dark rates (∼1 kHz/cm 2 ), single PE (SPE) timing resolution of ∼65 ps, and 𝒪(mm) position resolution. Coupled with a UV-grade fused silica window, the LAPPD features a high quantum efficiency (QE) bialkali photocathode of >30% at 365 nm with spectral response down to ∼165 nm. The LAPPD is an excellent candidate for electromagnetic calorimeter (ECAL) timing layers, photon-based neutrino detectors, high energy collider experiments, medical imaging systems, and nuclear non-proliferation applications.

Instruments & Instrumentation↗

Deep learning-based spatiotemporal multi-event reconstruction for delay line detectors

Abstract Accurate observation of two or more particles within a very narrow time window has always been a challenge in modern physics. It creates the possibility of correlation experiments, such as the ground-breaking Hanbury Brown–Twiss experiment, leading to new physical insights. For low-energy electrons, one possibility is to use a Microchannel plate with subsequent delay lines for the readout of the incident particle hits, a setup called a Delay Line Detector. The spatial and temporal coordinates of more than one particle can be fully reconstructed outside a region called the dead radius. For interesting events, where two electrons are close in space and time, the determination of the individual positions of the electrons requires elaborate peak finding algorithms. While classical methods work well with single particle hits, they fail to identify and reconstruct events caused by multiple nearby particles. To address this challenge, we present a new spatiotemporal machine learning model to identify and reconstruct the position and time of such multi-hit particle signals. This model achieves a much better resolution for nearby particle hits compared to the classical approach, removing some of the artifacts and reducing the dead radius a factor of eight. We show that machine learning models can be effective in improving the spatiotemporal performance of delay line detectors.

Computer Science↗

A novel two-layer-integrated microfluidic device for high-throughput yeast proteomic dynamics analysis at the single-cell level

Abstract Current microfluidic methods for studying multicell strains (e.g., m-types) with multienvironments (e.g., n-types) require large numbers of inlets/outlets (m*n), a complicated procedure or expensive machinery. Here, we developed a novel two-layer-integrated method to combine different PDMS microchannel layers with different functions into one chip by a PDMS through-hole array, which improved the design of a PDMS-based microfluidic system. Using this method, we succeeded in converting 2 × m × n inlets/outlets into m + n inlets/outlets and reduced the time cost of loading processing (from m × n to m) of the device for studying multicell strains (e.g., m-types) in varied multitemporal environments (i.e., n-types). Using this device, the dynamic behavior of the cell-stress-response proteins was studied when the glucose concentration decreased from 2% to a series of lower concentrations. Our device could also be widely used in high-throughput studies of various stress responses, and the new concept of a multilayer-integrated fabrication method could greatly improve the design of PDMS-based microfluidic systems.

Chen, Kaiyue↗

Single-shot ionization-based monitor for pulsed electron beams

In this work, we present an experimental demonstration of a single-shot, nondestructive electron beam diagnostic based on the ionization of a low-density pulsed gas jet. In our study, 7 MeV electron bunches from a radio-frequency photoinjector, carrying up to 100 pC of charge, traversed a localized distribution of nitrogen gas (N 2 ). The interaction of the electron bunches with the N 2 gas generated a correlated signature in the ionized particle distribution, which was spatially magnified using a series of electrostatic lenses and recorded with a microchannel-plate detector. Various modalities, including point-to-point imaging and velocity mapping, are investigated. A temporal trace of the detector current enabled the identification of single- and double-ionization events. The characteristics of the ionization distribution, dependence on gas density, total bunch charge, and other parameters, are described. Approaches to scaling to higher electron bunch density and energy are suggested. Additionally, the instrument proves useful for comprehensive studies of the ionization process itself.

47 OTHER INSTRUMENTATION↗

β -Nuclear-Recoil Correlation from $^6$$\mathrm{He}$ Decay in a Laser Trap

Here, we report the first precise measurement of a β-recoil correlation from a radioactive noble gas ( 6 He) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield |C T /C A | 2 ≤ 0.022 (90% confidence limit, C.L.). On the other hand, for left-handed neutrinos the limits are 0.007 < C T /C A < 0.111 (90% C.L.). The sensitivity of the present measurement is mainly limited by experimental uncertainties in determining the time response properties and the distance between the atom cloud and the microchannel plate used for recoil ion detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Conjugate Heat Transfer Analysis of the Supercritical CO2 Based Counter Flow Compact 3D Heat Exchangers

Compact heat exchangers using supercritical fluids such as CO2 are preferred due to their high heat transfer capacity and smaller footprint. Three-dimensional conjugate forced convection heat transfer analysis was performed on several shell-and-tube counter-flow microchannel heat exchangers. Numerical simulations were conducted to test effect of change in mass flow rate, hydraulic diameter and various cross sections on the heat transfer. Increasing mass flow rate improved heat transfer up to a maximum value and then decreased downstream with increasing turbulence. Maximum heat transfer was obtained for the micro channel with the smallest hydraulic diameter. Amongst the cross sections analyzed (circular, square, circular with radial ribs, and square with radial ribs), the most uniform distribution of temperature and maximum heat transfer were obtained for circular cross section with radial ribs. An optimally efficient operation of such a heat exchanger can be attained by considering these factors during multi-objective constrained optimization of geometric parameters and requirements for additive manufacturing of such compact heat exchangers.

Chitale, Janhavi↗