Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mesurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

138 records · Page 8

Avanced Jupiter Probe

This paper describes the results of new analyses and mission/system designs for low cost Advanced Jupiter Probes. Science and mesurement objectives, instrumentation, entry probe design, and mission/system design options are described and reflect an aggressive approach to the application of new advance technologies expected to be both available and developed over the next ten years.

Jupiter probes cost Jupiter composition Jupiter zo↗

Cassini Star Tracking and Identification Architecture

The Cassini spacecraft will launch October 1997 and will perform a detailed examination of the Saturnian system, including the release of a probe to study Saturn's Largest satellite, Titan. The star tracker for the Cassini mission must provide accurate data during the 12 years of flight including four years of mesurement in a harsh radiation environment.

Cassini↗

Mission Design for the Mars Environmental Survey

The purpose of this paper is to discuss some of the pertinent mission design issues associated with MESUR. Some details are given on the mission aspects of the network architecture studies. In addition, there is a description of the design trades that have been performed for pathfinder and the resulting reference mission design.

Mars↗

Precision X-Band Doppler and Ranging Navigation For Current and Future Mars Exploration Missions

This paper describes a navigation error convariance analysis of two scenarios derived from the Mars Observer mission and the planned Mars Environmental Survey (MESUR) Pathfinder mission, respectively. The analysis was performed to establish the potential navigational performance of the X-band tracking system in NASA's Deep Space Network, and to evaluate the sensitivity of the Predicted performance to variations in the quantity of data acquired, the ground system error modeling assumptions, and data reduction schemes.

Precision↗

Mission Design For the Mars Environmental Survey

The Mars Environmental Survey (MESUR) mission is the next logical evolutionary step in the thirty year program of Mars exploration. The purpose of this mission is to perform long duration in situ scientific measurements of the Martian environment at a number of globally distributed sites.

Mars↗

A Pulsar-Based Time-Scale from the International Pulsar Timing Array

We have constructed a new time-scale, TT(IPTA16), based on observations of radio pulsars presented in the first data release from the International Pulsar Timing Array (IPTA). We used two analysis techniques with independent estimates of the noise models for the pulsar observations and different algorithms for obtaining the pulsar time-scale. The two analyses agree within the estimated uncertainties and both agree with TT(BIPM17), a post-corrected time-scale produced by the Bureau International des Poids et Mesures (BIPM). We show that both methods could detect significant errors in TT(BIPM17) if they were present. We estimate the stability of the atomic clocks from which TT(BIPM17) is derived using observations of four rubidium fountain clocks at the US Naval Observatory. Comparing the power spectrum of TT(IPTA16) with that of these fountain clocks suggests that pulsar-based time-scales are unlikely to contribute to the stability of the best time-scales over the next decade, but they will remain a valuable independent check on atomic time-scales. We also find that the stability of the pulsar-based time-scale is likely to be limited by our knowledge of solar-system dynamics, and that errors in TT(BIPM17) will not be a limiting factor for the primary goal of the IPTA, which is to search for the signatures of nano-Hertz gravitational waves.

G. Hobbs↗

The Path to Large-Mass Double Beta Decay Experiments

The technology is ready for atmospheric scale sensitivity and we can at least discuss it for the solar scale. Even null results will be interesting. Supporting measurements are important and have an impact. Need several mesurements with a total uncertainty (experiment and theory) of {approx} 50% or less, and eventually even better. If we see {beta}{beta} the qualitative physics results are profound, but next we'll want to quantify the underlying physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of Calibration of Sensors Used for the Quantification of Nuclear Energy Rate Deposition

This present work deals with a collaborative program called GAMMA-MAJOR 'Development and qualification of a deterministic scheme for the evaluation of GAMMA heating in MTR reactors with exploitation as example MARIA reactor and Jules Horowitz Reactor' between the National Centre for Nuclear Research of Poland, the French Atomic Energy and Alternative Energies Commission and Aix Marseille University. One of main objectives of this program is to optimize the nuclear heating quantification thanks to calculation validated from experimental measurements of radiation energy deposition carried out in irradiation reactors. The quantification of the nuclear heating is a key data especially for the thermal, mechanical design and sizing of irradiation experimental devices in specific irradiated conditions and locations. The determination of this data is usually performed by differential calorimeters and gamma thermometers such as used in the experimental multi-sensors device called CARMEN 'Calorimetric en Reacteur et Mesures des Emissions Nucleaires'. In the framework of the GAMMA-MAJOR program a new calorimeter was designed for the nuclear energy deposition quantification. It corresponds to a single-cell calorimeter and it is called KAROLINA. This calorimeter was recently tested during an irradiation campaign inside MARIA reactor in Poland. This new single-cell calorimeter differs from previous CALMOS or CARMEN type differential calorimeters according to three main points: its geometry, its preliminary out-of-pile calibration, and its in-pile measurement method. The differential calorimeter, which is made of two identical cells containing heaters, has a calibration method based on the use of steady thermal states reached by simulating the nuclear energy deposition into the calorimeter sample by Joule effect; whereas the single-cell calorimeter, which has no heater, is calibrated by using the transient thermal response of the sensor (heating and cooling steps). The paper will concern these two kinds of calorimetric sensors. It will focus in particular on studies on their out-of-pile calibrations. Firstly, the characteristics of the sensor designs will be detailed (such as geometry, dimension, material sample, assembly, instrumentation). Then the out-of-pile calibration methods will be described. Furthermore numerical results obtained thanks to 2D axisymmetrical thermal simulations (Finite Element Method, CAST3M) and experimental results will be presented for each sensor. A comparison of the two different thermal sensor behaviours will be realized. To conclude a discussion of the advantages and the drawbacks of each sensor will be performed especially regarding measurement methods. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modified MTS MRB500 CATALYST PERFORMANCE TEST

An experiment was conducted to determine if the oxygen supply in a CuO catalyst considered for use in the TMIST-2 irradiation test would be sufficient to convert all the hydrogen isotopes coming from the irradiation test to water. A mixture of 2% H2 in Ar was supplied to a modified MRB 500 stack m onitor from Mound Techology Solutions, Miamisburg, OH. It was found that the catalyst could convert 3.75E-03 moles of H2 before losing its effectiveness. Conversion was found to begin at a catalyst temperature of about 220 deg C and to be fully effective at about 300 deg C.

08 HYDROGEN↗