Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Medical Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

An Application of Faster R-CNNs in Object Detection Efforts Applied to the Critical Infrastructure Domain

Object detection and segmentation approaches have been successfully applied to multiple interdisciplinary domains ranging from medical imaging to autonomous vehicles. The following study details efforts to apply segmentation methods to the critical infrastructure domain. Specifically, the identification of critical sub-components of four facilities: airports, hospitals, hydroelectric dams, and water treatment plants. Data for this study was extracted from the U.S. Department of Agriculture’s National Agriculture Imagery Program data set. Each facility class was considered independently of the other facilities, producing four different segmentation models during the testing and training process. Ultimately, the study team concluded there are significant challenges associated with object detection modeling when applied to facility analysis within the critical infrastructure domain. The study team was able to identify possible sources of these challenges that could be potentially addressed in future work.

97 MATHEMATICS AND COMPUTING↗

Ultrasonic Measurements of Temperature Profile and Heat Fluxes in Coal-Fired Power Plants (Final Report)

Many industrial processes are inaccessible or inhospitable to characterization by traditional temperature measurement methods, such as thermocouples, especially over prolonged exposure to harsh environments. Ultrasound is an established characterization technology with diverse applications ranging from medical imaging to therapies to flaw detection to nondestructive evaluation. Ultrasound may characterize solid materials and components noninvasively as a nondestructive evaluation modality and obtain internal measurements of material properties. For example, the speed of ultrasound propagation changes with Young’s modulus and Poisson’s ratio, which can be found from its measurements. Traditional ultrasonic characterization assumes all material properties remain constant with the position. When this assumption holds, a property of interest may be measured by relating it to the speed of ultrasound propagation (or a speed of sound, SOS) and measuring the SOS by timing the ultrasound propagation through a known distance. However, when a property of interest is spatially distributed, the propagation time depends on the SOS changing with the position along the ultrasound propagation path. The multiple temperature distributions may lead to an identical time of flight (TOF). Temperature is one property that impacts the speed of ultrasound and often cannot be assumed to remain constant with the position. Previously, in the context of temperature, we addressed the challenge of ultrasonic characterization of spatially distributed properties by developing a method for measuring segmental temperature distributions (MSTD). This method divides the ultrasonic propagation into segments bound by echogenic features. These features provide ultrasonic interfaces where some energy is reflected toward the receiving transducer, and the rest continues through the medium. The time-of-flight between the echoes reflected from echogenic features characterizes the spatial distribution in the properties of interest in the corresponding segment of the ultrasonic propagation path. This project demonstrated the application of the MSTD method in industrial conditions of the coal-fired power plant. We implemented the MSTD using metals and alloys waveguides, which may be the existing structure for which the temperature distribution is characterized or purposefully designed waveguides added to the structure by welding or other means specifically to quantify thermal properties using the MSTD method. Previous iterations of the MSTD method used ceramic and cementitious waveguides, which significantly attenuate ultrasound. On the other hand, low attenuation in metallic waveguides creates interactions between echogenic features which compilates the signal analysis in the segmental TOF measurements. We have established the WG design principles that minimize the interferences between trailing and primary echoes and, in some cases, eliminate them. The waveguides in which echoes do not interfere improve the timing accuracy and the robustness of ultrasonic measurements of the spatial distributions in material properties. Our emphasis remained on the estimation of the temperature distributions. We have developed general recommendations for designing ultrasonically segmented waveguides with the reduced influence of trailing echoes. Two of our waveguide designs were tested in the industry. The first waveguide was designed for insertion into a combustion zone of the utility-scale coal-fired power plant boiler. The second design allows the characterization of temperature distribution in the direction normal to the boiler’s water wall, a large heat exchanger converting the chemical energy released during combustion to the steam driving the electrical power generation turbines. These waveguides were designed to operate within a restrictive space of thermally insulated water wall and incorporate densely located echogenic features while combatting the influence of trailing echoes. The project has successfully demonstrated the feasibility of using the developed method for accurate, continuous, and robust temperature measurements in extreme environments of power generation and other industrial processes. It, therefore, has achieved its overarching goal of advancing the technology readiness level of the novel Ultrasound Measurements of Segmental Temperature Distribution (US-MSTD) method for real-time measurements of the temperature distribution and heat fluxes closer to commercial availability, developing a prototype multipoint measurement system, and validating its performance on coal-fired utility boilers. The success of this project was achieved in collaboration with the power generator, Rocky Mountain Power, and set the stage for the transfer of this technology from the laboratory to the industry.

01 COAL, LIGNITE, AND PEAT↗

Resilient GaN-based Power Module with Improved Diagnostic for Future Accelerator

Los Alamos Neutron Science Center (LANSCE) and Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) play a pivotal role in advancing scientific research and national security initiatives. As a premier facility for neutron science, LANSCE and DARHT provide invaluable insights into fundamental research, materials science, nuclear physics, high-energy physics, material science, and medical imaging. Existing (DC) power supply and pulse modulation technologies used in LANSCE and DARHT face limitations in terms of reliability, maintainability, and diagnostics which hinder the progress of these cutting-edge facilities. By proposing improvements to LANL accelerator facilities’ performance and addressing component failure, we aim to enhance scientific outcomes and minimize disruptions, allowing for more efficient and productive research activities while ensuring the continuity of valuable contributions to the user community. This proposal aims to revolutionize (DC) power supply and pulse power systems for future particle accelerators via the development of a resilient GaN-based power module with improved diagnostic and redundant submodules.

43 PARTICLE ACCELERATORS↗

Characterization of High-Temperature SiPM Noise

Introduction • Background: Silicon photomultipliers (SiPMs) are compact, low-power, and high-efficiency detectors that are increasingly used in radiation detection applications like medical imaging and nuclear safeguards. The have advantages of PMTs because they are smaller, operate at lower voltages, and offer high photon detection efficiency. • Challenges: SiPMs suffer from increased dark count rate (DCR) and optical crosstalk (OCT), which degrades performance. • Purpose of study: This study compares the Advansid ASD-NUV3S-P-40, Broadcom AFBR-S4K33C0147L, and Onsemi MicroFJ-30035-TSVTR under four different temperatures to compare their performance in harsh environments.

Fritchie, Jacob↗

Effect of Surface Passivation of CZTS Semiconductor Detector on Leakage Current

Cadmium Zinc Telluride Selenide (CdZnTeSe or CZTS)has shown high crystal quality for room-temperature gamma ray and X-ray detection applications compared to Cadmium Zinc Telluride (CdZnTe or CZT) [1,2]. Current applications of CZT include medical imaging, homeland security, and X-ray and gamma ray astronomy [3]. CZST has similar potential applications

Kangethe, Anthony [Morgan State Univ., Baltimore, ↗

FAIR Data and Interpretable AI Framework for Architectured Metamaterials (Final Report)

This research program established a transformative framework for the discovery and design of mechanical metamaterials, which are architected structures engineered to control physical phenomena like sound and vibration in ways natural materials cannot. To overcome the traditional reliance on trial-and-error, the project developed an interpretable Artificial Intelligence (AI) framework that moves beyond "black box" models to reveal the specific geometric patterns—such as "unit-cell templates"—that govern a material’s performance. A major breakthrough was the development of a hierarchical design method, which allows a single material to block vibrations across multiple frequency ranges simultaneously by layering patterns at different scales without them interfering with one another. This was further expanded to include irregular, graph-based designs that use spanning tree algorithms to ensure structural connectivity while allowing for customized, direction-dependent properties like stiffness and acoustic impedance. Beyond design, the project addressed the practicalities of real-world production by developing uncertainty quantification techniques that account for manufacturing defects and material variability, reducing the need for expensive physical testing by orders of magnitude. To speed up the discovery process, the team implemented Gaussian Process Regression and other surrogate models that provide accurate performance predictions at a fraction of the traditional computational cost. The AI-generated designs were successfully validated through fabrication of physical samples and wave propagation experiments, confirming their ability to accurately guide or reflect waves as predicted. By contributing these tools and high-quality FAIR benchmark datasets to the wider scientific community, this work provides a scalable foundation for advancing technologies in aerospace vibration control, medical imaging, and noise reduction.

36 MATERIALS SCIENCE↗

PSEC5 Physical Verification

Ultra-Fast timing detectors, having a time resolution of 10pSec or less, are becoming increasingly important for many scientific disciplines, including High Energy Physics, Nuclear Physics, Medical Imaging and more. When developing ultra-fast detectors such as MCPs, LAPPDs, LGADs, SNSPDs, it is necessary to have access to a readout system that is low power, can support many channels and is cost effective. The PSEC5 chip was an application specific integrated circuit (ASIC) developed by the pioneering group of Prof. Henry Frisch at University of Chicago and micro electronic engineers at Fermi National Accelerator Laboratory. Three boards were designed, two to implement the readout system for an LAPPD and one to only characterize the PSEC1 chip. The main goal of the project shifted to setting up a testing environment to focus on the characterization of the chip. My student and I tested and characterized this ASIC using the third chip-on-board printed circuit board. Results show the successful fabrication and operation of some of the key building blocks and lead to the suggestions on modification for the second iteration of the chip.

Rico Aniles, H. D. [Unlisted]↗

Electrochemical hydrogen isotope fractionation - fundamental insights leading to process scale up

Introduction Deuterium and tritium, the two isotopes of hydrogen besides protium, are utilized in many industries. Deuterium is routinely used as a nuclear reactor moderator and molecular labeling agent, while tritium is used as an autoradiography label in medical imaging, and in an emerging market for self-powered lighting for watches, exit signs, firearm night-sights and future fusion fuel. Tritium is produced naturally at very low steady-state levels due to cosmic rays, natural nuclear decay reactions, as well as commercial nuclear fission reactors, and terrestrial nuclear testing conducted primarily in the mid-twentieth century. Tritium often accumulates in the heavy water used in nuclear fission reactors and sometimes appears in groundwater near nuclear reactors due to slight leakage from water sources in the reactor. Because of the health and environmental impacts from tritium leaking into the water sources, as well as the value of this precious material, it is desirable to remove and recover as much tritium as reasonably possible from contaminated water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Poisson-response Tensor-on-Tensor Regression and Applications

We introduce Poisson-response tensor-on-tensor regression (PToTR), a novel regression framework designed to handle tensor responses composed element-wise of random Poisson-distributed counts. Tensors, or multi-dimensional arrays, composed of counts are common data in fields such as inter national relations, social networks, epidemiology, and medical imaging, where events occur across multiple dimensions like time, location, and dyads. PToTR accommodates such tensor responses alongside tensor covariates, providing a versatile tool for multi dimensional data analysis. We propose algorithms for maximum likelihood estimation under a canonical polyadic (CP) structure on the regression coefficient tensor that satisfy the positivity of Poisson parameters and then provide an initial theoretical error analysis for PToTR estimators. We also demonstrate the utility of PToTR through three concrete applications: longitudinal data analysis of the Integrated Crisis Early Warning System database, positron emission tomography (PET) image reconstruction, and change-point detection of communication patterns in longitudinal dyadic data. These applications highlight the versatility of PToTR in addressing complex, structured count data across various domains.

97 MATHEMATICS AND COMPUTING↗

Evaluation of intracoronary hemodynamics identifies perturbations in vorticity

Coronary artery disease (CAD) is highly prevalent and associated with adverse events. Challenges have emerged in the treatment of intermediate coronary artery stenoses. These lesions are often interrogated with fractional flow reserve (FFR) testing to determine if a stenosis is likely to be causative for ischemia in a cardiac territory. This invasive test requires insertion of a pressure wire into a coronary vessel. Recently computational fluid dynamics (CFD) has been used to noninvasively assess fractional flow reserve in vessels reconstructed from medical imaging data. However, many of these simulations are unable to provide additional information about intravascular hemodynamics, including velocity, endothelial shear stress (ESS), and vorticity. We hypothesized that vorticity, which has demonstrated utility in the assessment of ventricular and aortic diseases, would also be an important hemodynamic factor in CAD. Three-dimensional (3D), patient-specific coronary artery geometries that included all vessels >1 mm in diameter were created from angiography data obtained from 10 patients who underwent diagnostic angiography and FFR testing (n = 9). A massively parallel CFD solver (HARVEY) was used to calculate coronary hemodynamic parameters including pressure, velocity, ESS, and vorticity. These simulations were validated by comparing velocity flow fields from simulation to both velocities derived from in vitro particle image velocimetry and to invasively acquired pressure wire-based data from clinical testing. There was strong agreement between findings from CFD simulations and particle image velocimetry experimental testing (p < 0.01). CFD-FFR was also highly correlated with invasively measured FFR (ρ = 0.77, p = 0.01) with an average error of 5.9 ± 0.1%. CFD-FFR also had a strong inverse correlation with the vorticity (ρ = -0.86, p = 0.001). Simulations to determine the effect of the coronary stenosis on intravascular hemodynamics demonstrated significant differences in velocity and vorticity (both p < 0.05). Further evaluation of an angiographically normal appearing non-FFR coronary vessel in patients with CAD also demonstrated differences in vorticity when compared with FFR vessels (p < 0.05). The use of highly accurate 3D CFD-derived intravascular hemodynamics provides additional information beyond pressure measurements that can be used to calculate FFR. Vorticity is one parameter that is modified by a coronary stenosis and appears to be abnormal in angiographically normal vessels in patients with CAD, highlighting a possible use-case in preventative screening for early coronary disease.

59 BASIC BIOLOGICAL SCIENCES↗

Quaternary Semiconductor Cd1−xZnxTe1−ySey for High-Resolution, Room-Temperature Gamma-Ray Detection

The application of Cd0.9Zn0.1Te (CZT) single crystals, the primary choice for high-resolution, room-temperature compact gamma-ray detectors in the field of medical imaging and homeland security for the past three decades, is limited by the high cost of production and maintenance due to low detector grade crystal growth yield. The recent advent of its quaternary successor, Cd0.9Zn0.1Te1−ySey (CZTS), has exhibited remarkable crystal growth yield above 90% compared to that of ~33% for CZT. The inclusion of Se in appropriate stoichiometry in the CZT matrix is responsible for reducing the concentration of sub-grain boundary (SGB) networks which greatly enhances the compositional homogeneity and growth yield. SGB networks also host defect centers responsible for charge trapping, hence their reduced concentration ensures minimized charge trapping. Indeed, CZTS single crystals have shown remarkable improvement in electron charge transport properties and energy resolution over CZT detectors. However, our studies have found that the overall charge transport in CZTS is still limited by the hole trapping. In this article, we systematically review the advances in the CZTS growth techniques, its performance as room-temperature radiation detector, and the role of defects and their passivation studies needed to improve the performance of CZTS detectors further.

36 MATERIALS SCIENCE↗

Characterization of Crystal Properties and Defects in CdZnTe Radiation Detectors

CdZnTe-based detectors are highly valued because of their high spectral resolution, which is an essential feature for nuclear medical imaging. However, this resolution is compromised when there are substantial defects in the CdZnTe crystals. In this study, we present a learning-based approach to determine the spatially dependent bulk properties and defects in semiconductor detectors. This characterization allows us to mitigate and compensate for the undesired effects caused by crystal impurities. We tested our model with computer-generated noise-free input data, where it showed excellent accuracy, achieving an average RMSE of 0.43% between the predicted and the ground truth crystal properties. In addition, a sensitivity analysis was performed to determine the effect of noisy data on the accuracy of the model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Substituent Location on the Relationship between the Transition Dipole Moments, Difference Static Dipole, and Hydrophobicity in Squaraine Dyes for Quantum Information Devices

Aggregates of organic dyes that exhibit excitonic coupling have a wide array of applications, including medical imaging, organic photovoltaics, and quantum information devices. The optical properties of a dye monomer, as a basis of dye aggregate, can be modified to strengthen excitonic coupling. Squaraine (SQ) dyes are attractive for those applications due to their strong absorbance peak in the visible range. While the effects of substituent types on the optical properties of SQ dyes have been previously examined, the effects of various substituent locations have not yet been investigated. In this study, density functional theory (DFT) and time-dependent density functional theory (TD-DFT) were used to investigate the relationships between SQ substituent location and several key properties of the performance of dye aggregate systems, namely, difference static dipole (Δd), transition dipole moment (μ), hydrophobicity, and the angle (θ) between Δd and μ. We found that attaching substituents along the long axis of the dye could increase μ while placement off the long axis was shown to increase Δd and reduce θ. The reduction in θ is largely due to a change in the direction of Δd as the direction of μ is not significantly affected by substituent position. Hydrophobicity decreases when electron-donating substituents are located close to the nitrogen of the indolenine ring. These results provide insight into the structure–property relationships of SQ dyes and guide the design of dye monomers for aggregate systems with desired properties and performance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Advances in CdZnTeSe for Radiation Detector Applications

Detection of X- and gamma-rays is essential to a wide range of applications from medical imaging to high energy physics, astronomy, and homeland security. Cadmium zinc telluride (CZT) is the most widely used material for room-temperature detector applications and has been fulfilling the requirements for growing detection demands over the last three decades. However, CZT still suffers from the presence of a high density of performance-limiting defects, such as sub-grain boundary networks and Te inclusions. Cadmium zinc telluride selenide (CZTS) is an emerging material with compelling properties that mitigate some of the long-standing issues seen in CZT. This new quaternary is free from sub-grain boundary networks and possesses very few Te inclusions. In addition, the material offers a high degree of compositional homogeneity. The advancement of CZTS has accelerated through investigations of the material properties and virtual Frisch-grid (VFG) detector performance. The excellent material quality with highly reduced performance-limiting defects elevates the importance of CZTS as a potential replacement to CZT at a substantially lower cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of an AC-LGAD strip sensor with a 120 GeV proton beam

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. In addition to high time resolution and thanks to the AC-coupling of the electrodes, LGAD silicon sensors can provide high resolution in the measurement of spatial coordinates of an incident minimum ionizing particle. Such AC-coupled LGADs, also known as AC-LGADs, are therefore considered as candidates for future detectors to provide 4-dimensional measurements in a single sensing device with 100$\%$ fill factor. This article presents the first characterization of an AC-LGAD sensor with a proton beam of 120 GeV momentum at Fermilab. The sensor consists of strips with 80 $\mu$m width, fabricated at Brookhaven National Laboratory. The signal properties, efficiency, spatial, and time resolution are presented. The experimental results show that the time resolution of such an AC-LGAD is compatible to standard LGADs with similar gain, and that AC-LGADs can be segmented with fine pitches as standard strip or pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Million Worker Study

Radiation health issues have been an important aspect of DOE's Worker Safety and Health programs. The goal is to ensure that workers are adequately protected from the various radiological hazards associated with DOE sites and operations. Since the early 1940’s DOE has supported the conduct of epidemiologic studies of practically every DOE (AEC) facility and collected these data, now managed by the Oak Ridge Associated Universities (ORAU), in remarkable detail. In the early 2000s, the Office of Health, Safety and Security authorized access to specific DOE worker datasets. Shortly thereafter, the DOE Office of Science provided funds for a pilot study that confirmed the feasibility of the Million Worker Study (MWS), and then additional resources were provided (with other agencies) to extend the follow-up of many populations, not just DOE workers, but also atomic veterans, industrial radiographers, nuclear power plant workers and medical radiation workers (the Million Persons Study (MPS)). This proposal was a continuation of support provided by DOE, specifically to extend the follow-up of the worker populations at the Mallinckrodt Chemical Works (MCW) and Los Alamos National Laboratory (LANL). The work addresses DOE’s interest in clarifying the health risks of their workers as well as contributing knowledge on radiation risks that is relevant today with regard to compensation schemes. The findings are also important for the US public in light of the increased population exposure to medical imaging, environmental circumstances such as hydraulic fracturing, increased exposures during high altitude flights, and with regard to nuclear accidents such as Fukushima and possible terrorist events. Furthermore, it is important to consider reducing the uncertainty in current risk estimates by developing risk coefficients based on healthy American workers who are more representative of U.S. workers and the general public than 1945 Japanese survivors of the atomic bombs living in a war-torn country which experienced deprivation, malnourishment, and increased rates of infections and other diseases. But more importantly, it is important to learn whether radiation exposures received gradually over time (e.g., years) are more or less effective in causing health effects, cancer in particular, than if the radiation dose is received all at once in a fraction of a second as experienced by the Japanese atomic bomb survivors. Finally, the ability to evaluate and combine large populations with intakes of radionuclides such as uranium, radium, plutonium, americium and polonium will provide new quantitative knowledge on human health effects that hitherto has not been possible. This cost-efficient study has built on the investments made and foundations laid by investigators and government agencies, including DOE, over the past 30-40 years, which have established early worker cohorts that can now provide answers to questions on the lifetime human health risks associated with low-level radiation exposures. Collaborating institutions included: International Epidemiology Institute, Oak Ridge Associated Universities, Oak Ridge National Laboratory, Los Alamos National Laboratory, Landauer, Inc., and Vanderbilt University. Follow-up of these two populations and the integration of them with the many other cohorts (now a total of 31) in the MPS continues under a separate DOE grant (DE-AU0000046).

61 RADIATION PROTECTION AND DOSIMETRY↗

Peptoid-based chelating ligands for selective metal chelation

The present disclosure provides peptoid-based chelating ligands, corresponding cyclic peptoids, and methods of making thereof. Functional groups may be tailored for high metal binding affinity and selectivity. The side chains of a cyclic peptoid according to the present disclosure may be selected based on, for example, high affinity for actinide or other metal ions, selectivity for actinide or other metal ions, the ability to recover a metal once it is bound to the peptoid, and whether the overall peptoid should be hydrophobic or hydrophilic. Unlike siderophores, peptoid-based chelating ligands of the present disclosure are not readily hydrolyzed under physiological conditions. Therefore, peptoid-based chelating ligands may be, for example, used to treat actinide (e.g., iron and lead) poisoning in vivo. Moreover, peptoid-based chelating ligands of the present disclosure may be used for medical imaging, chelation therapy, drug delivery, and separation technologies, for example.

Williams, Robert F.↗

Peptoid-based chelating ligands for selective metal chelation

The present disclosure provides peptoid-based chelating ligands, corresponding cyclic peptoids, and methods of making thereof. Functional groups may be tailored for high metal binding affinity and selectivity. The side chains of a cyclic peptoid according to the present disclosure may be selected based on, for example, high affinity for actinide or other metal ions, selectivity for actinide or other metal ions, the ability to recover a metal once it is bound to the peptoid, and whether the overall peptoid should be hydrophobic or hydrophilic. Unlike siderophores, peptoid-based chelating ligands of the present disclosure are not readily hydrolyzed under physiological conditions. Therefore, peptoid-based chelating ligands may be, for example, used to treat actinide (e.g., iron and lead) poisoning in vivo. Moreover, peptoid-based chelating ligands of the present disclosure may be used for medical imaging, chelation therapy, drug delivery, and separation technologies, for example.

Williams, Robert F.↗