Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic resonance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Detecting rare earth elements via optically detected magnetic resonance (ODMR) and spin-relaxometry using nitrogen vacancy centers in nanodiamonds

Nanodiamonds embedded with nitrogen-vacancy (NV) centers are emerging as powerful tools in quantum sensing due to their remarkable sensitivity to local variations in electromagnetic fields, temperature, and pressure. These point defects in the diamond lattice can be probed using optically detected magnetic resonance (ODMR) and spin relaxometry techniques, allowing for the detection and characterization of magnetic nanoparticles and ions. The sensing mechanism relies on laser-induced excitation of the NV center's non-degenerate triplet ground state, which promotes electrons to an excited state. Subsequent photoluminescence (PL) emission, which is spin-state dependent, is then measured. These spin states are highly responsive to magnetic perturbations in the surrounding environment. By analyzing changes in the ODMR spectra and spin relaxation times, we can effectively monitor how magnetic species influence the NV center's spin dynamics, thus enabling sensitive and selective characterization of nanoscale magnetic materials. These techniques have been applied for the characterization of transition metals and rare earth elements which shows natural ferromagnetic properties.

magnetic nanopartgicles and ions↗

Small resonant magnetic perturbations result in three-dimensional material transport in the fusion plasma edge

Erosion patterns in a 3D magnetic topology are significantly altered when compared to an axisymmetric scenario due to differences in the impurity transport in a plasma environment. When resonant magnetic perturbations are applied in L-Mode discharges, eroded impurities can buildup in regions where an axisymmetric plasma would otherwise lead to zones of net erosion across the full toroidal length of the divertor. The reduction on the local and integrated erosion observed across a parametric study of the anomalous diffusion and impurity content in a plasma, can lead to the extension of divertor lifetimes in low power scenarios when 3D fields are applied. By contrast, in axisymmetric scenarios, most of the carbon eroded from the divertor are carried away to the far scrape-off layer.

DIII-D↗

Left ventricular dimensions and mass using magnetic resonance imaging in female endurance athletes

Few published studies of left ventricular (LV) mass in female endurance athletes have been performed with M-mode echocardiography, which involves assumptions of LV geometry. Therefore, magnetic resonance imaging, a 3-dimensional technique, was used to examine LV mass, LV end-diastolic volume and mean wall thickness in female long distance runners (n = 13; mean age 29 years), cyclists (n = 12; mean age 26 years) and cross-country skiers (n = 11; mean age 24 years), and the findings were compared with sedentary control subjects (n = 10; mean age 27 years) matched for height and body weight. The physical characteristics for all subjects included height (mean 166 cm, and body weight (mean 56 kg). The percent body fat (mean 11.7) and maximal oxygen uptake (VO2max, mean 63 ml.kg-1.min-1) were similar (p greater than 0.05) among all athletic groups, but significantly different from the control group (body fat, mean 22.5%; VO2max, mean 35 ml.kg-1.min-1). LV mass (mean 159 kg), LV end-diastolic volume (mean 122 ml), and mean wall thickness (mean 11.5 mm) were also similar among the athletic groups and significantly larger than the following control values: LV mass (mean 115 g), LV end-diastolic volume (mean 93 ml) and mean wall thickness (mean 9.8 mm). Ratios of LV mass to lean body weight were similar among all athletic groups, although athletic groups had larger ratios (p less than 0.05) than the sedentary control subjects. LV mass/LV end-diastolic volume ratio was similar (p greater than 0.05) among all groups.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Cardiopulmonary↗

Stochastic fluctuation and transport of tokamak edge plasmas with the resonant magnetic perturbation field

Here we present that a statistical method known as the complexity–entropy analysis is useful to characterize a state of plasma turbulence and flux in the resonant magnetic perturbation (RMP) edge localized mode (ELM) control experiment. The stochastic pedestal top temperature fluctuation in the RMP ELM suppression phase is distinguished from the chaotic fluctuation in the natural ELM-free phase. It is discussed that the stochastic temperature fluctuation can be originated from the narrow layer of the field penetration on the pedestal top. The forced magnetic island can emit the resonant drift wave of comparable sizes (relatively low-k) in the RMP ELM suppression phase, and it can result in the generation of stochastic higher wavenumber fluctuations coupled to tangled fields around the island. The analysis of the ion saturation current measurement around the major outer striking point on the divertor shows that it also becomes more stochastic as the stronger plasma response to the RMP field is expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic resonance imaging of the calcaneus: preliminary assessment of trabecular bone-dependent regional variations in marrow relaxation time compared with dual X-ray absorptiometry

RATIONALE AND OBJECTIVES: Marrow transverse relaxation time (T2*) in magnetic resonance (MR) imaging may be related to the density and structure of the surrounding trabecular network. We investigated regional variations of T2* in the human calcaneus and compared the findings with bone mineral density (BMD), as measured by dual X-ray absorpiometry (DXA). Short- and long-term precisions were evaluated first to determine whether MR imaging would be useful for the clinical assessment of disease status and progression in osteoporosis. METHODS: Gradient-recalled echo MR images of the calcaneus were acquired at 1.5 T from six volunteers. Measurements of T2* were compared with BMD and (for one volunteer) conventional radiography. RESULTS: T2* values showed significant regional variation; they typically were shortest in the superior region of the calcaneus. There was a linear correlation between MR and DXA measurements (r = .66 for 1/T2* versus BMD). Differences in T2* attributable to variations in analysis region-of-interest placement were not significant for five of the six volunteers. Sagittal MR images had short- and long-term precision errors of 4.2% and 3.3%, respectively. For DXA, the precision was 1.3% (coefficient of variation). CONCLUSION: MR imaging may be useful for trabecular bone assessment in the calcaneus. However, given the large regional variations in bone density and structure, the choice of an ROI is likely to play a major role in the accuracy, precision, and overall clinical efficacy of T2* measurements.

Non-NASA Center↗

The role of edge resonant magnetic perturbations in edge-localized-mode suppression and density pump-out in low-collisionality DIII-D plasmas

Two-fluid nonlinear MHD simulations using the TM1 code demonstrate that the formation of magnetic islands at the top and bottom of the H-mode pedestal, together with the strong screening of resonant fields in the gradient region of the pedestal, can account for ELM suppression and density pump-out by n = 2 resonant magnetic perturbations (RMPs) in low-collisionality DIII-D ITER similar shape (ISS) plasmas. Using experimentally relevant transport coefficients, neoclassical resistivity, electron collisionality, and RMP amplitudes, nonlinear MHD simulations reproduce the observed level of density reduction (density pump-out) in DIII-D due to the formation of narrow magnetic islands in the resistive foot of pedestal. For large amplitude RMPs ( B r / B t > 1 × 10 -4 ) simulations predict resonant field penetration and resulting in pressure reduction at the top of the pedestal, consistent with experimental observations at the onset of ELM suppression. The predicted reduction in the height and width of the pedestal by magnetic island enhanced collisional transport provides a quantitative mechanism for the stabilization of the peeling-ballooning mode (PBM). Importantly, these simulations predict strong screening of resonant fields in the steep gradient region of the pedestal due to strong E × B rotation and diamagnetic flows. Yet, if the plasma resistivity is made artificially larger (~ 10X) than neoclassical, the simulations predict magnetic stochasticity throughout the plasma edge and the collapse of the pedestal due to the reduction in the penetration threshold with increasing resistivity. A scaling relation for resonant field penetration at the pedestal top, using several hundred nonlinear simulations, reproduces the density and E × B rotation dependence of the ELM suppression threshold observed in DIII-D. Simulations using ITER model equilibria indicate that the penetration threshold at the top of the ITER pedestal will be lower than in DIII-D due to the anticipated lower perpendicular flow velocities in ITER, resulting in the weaker screening of resonant fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced detection of paramagnetic fluorine-19 magnetic resonance imaging agents using zero echo time sequence and compressed sensing

Fluorine-19 ( 19 F) magnetic resonance imaging (MRI) is an emerging technique offering specific detection of labeled cells in vivo. Lengthy acquisition times and modest signal-to-noise ratio (SNR) makes three-dimensional spin-density–weighted 19 F imaging challenging. Recent advances in tracer paramagnetic metallo-perfluorocarbon (MPFC) nanoemulsion probes have shown multifold SNR improvements due to an accelerated 19 F T 1 relaxation rate and a commensurate gain in imaging speed and averages. However, 19 F T 2 -reduction and increased linewidth limit the amount of metal additive in MPFC probes, thus constraining the ultimate SNR. To overcome these barriers, we describe a compressed sampling (CS) scheme, implemented using a “zero” echo time (ZTE) sequence, with data reconstructed via a sparsity-promoting algorithm. Our CS-ZTE scheme acquires k-space data using an undersampled spherical radial pattern and signal averaging. Image reconstruction employs off-the-shelf sparse solvers to solve a joint total variation and -norm regularized least square problem. To evaluate CS-ZTE, we performed simulations and acquired 19 F MRI data at 11.7 T in phantoms and mice receiving MPFC-labeled dendritic cells. For MPFC-labeled cells in vivo, we show SNR gains of ~6.3 × with 8-fold undersampling. We show that this enhancement is due to three mechanisms including undersampling and commensurate increase in signal averaging in a fixed scan time, denoising attributes from the CS algorithm, and paramagnetic reduction of T 1 . Importantly, 19 F image intensity analyses yield accurate estimates of absolute quantification of 19 F spins. Overall, the CS-ZTE method using MPFC probes achieves ultrafast imaging, a substantial boost in detection sensitivity, accurate 19 F spin quantification, and minimal image artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An improved nuclear magnetic resonance spectrometer

Cylindrical sample container provides a high degree of nuclear stabilization to a nuclear magnetic resonance /nmr/ spectrometer. It is placed coaxially about the nmr insert and contains reference sample that gives a signal suitable for locking the field and frequency of an nmr spectrometer with a simple audio modulation system.

Elleman, D. D.↗

A versatile pulse programmer for pulsed nuclear magnetic resonance spectroscopy.

A digital pulse programmer producing the standard pulse sequences required for pulsed nuclear magnetic resonance spectroscopy is described. In addition, a 'saturation burst' sequence, useful in the measurement of long relaxation times in solids, is provided. Both positive and negative 4 V trigger pulses are produced that are fully synchronous with a crystal-controlled time base, and the pulse programmer may be phase-locked with a maximum pulse jitter of 3 ns to the oscillator of a coherent pulse spectrometer. Medium speed TTL integrated circuits are used throughout.

Tarr, C. E.↗

A Field-Deployable Magnetic Resonance Imaging Rhizotron for Modeling and Enhancing Root Growth and Biogeochemical Function

A collaborative team from Texas A&M AgriLife Research, ABQMR Inc., the Soil Health Institute, the Athinoula A. Martinos Center for Biomedical Imaging, and NIST developed low-field magnetic resonance imaging (LF-MRI) instrumentation capable of imaging intact soil-root systems. The system measured root biomass, architecture, 3D mass distribution, and growth rates, providing a non-destructive means to evaluate ideal plant characteristics based on root metrics. It also successfully generated three-dimensional images of soil water content, a key property influencing root growth and exploration. Operating much like an MRI used in a medical setting, the system functioned in field conditions without damaging plants, overcoming the limitations of traditional methods such as trenching, soil coring, and root excavation. Over the course of the project, the team designed and built three functional prototype systems. These prototypes provided new insights into root–water–soil interactions that drive processes such as nutrient uptake, water use, and carbon management. This information contributed to efforts to optimize plants for carbon sequestration without sacrificing economic yield. The project also supported the identification of desirable traits for energy sorghum, including high root growth rates, more vertical root angles, and enhanced drought resilience under water-limiting conditions.

09 BIOMASS FUELS↗

Influence of triangularity on the plasma response to resonant magnetic perturbations

The effect of the axisymmetric plasma shape on the non-axisymmetric plasma response to resonant magnetic perturbations is investigated in experiment and modeling for the DIII-D, EAST and ASDEX Upgrade tokamaks. Systematically modeling the effect of the triangularity, whilst keeping other equilibrium quantities largely unchanged, reveals that the plasma response is strongly suppressed at high triangularity compared to that at low triangularity. This is validated through targeted comparison with experiments at DIII-D, EAST, and ASDEX Upgrade. DIII-D and EAST magnetic measurements are used to validate simulations, while at ASDEX Upgrade the plasma edge displacement is measured. Both experiments and modeling find a reduced magnetic plasma response on the high-field side at high triangularity across devices. Multi-modal analysis of the simulation results extracts the mode structure and applied spectrum dependence of each mode. The amplitude of the dominant mode reveals similar trends with the edge resonance and radial displacement near the X-point, which suggests that the multi-mode plasma response provides another way to understand the edge localized mode (ELM) control physics. The plasma response is strongly reduced at high triangularity compared to that at low triangularity, which implies different ELM control effects as shaping is varied. Furthermore, these findings indicate that the plasma shape should be taken into consideration when designing an RMP-ELM control strategy in experiment, and that predictive plasma response calculations can be used to maximize access to RMP-ELM control in future devices by maximizing the coupling between coils and the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of edge-localized electron cyclotron current drive on edge-localized mode suppression by resonant magnetic perturbations in DIII-D

Abstract According to recent DIII-D experiments (Logan et al 2024 Nucl. Fusion 64 014003), injecting edge localized electron cyclotron current drive (ECCD) in the counter-plasma-current (counter- I p ) direction reduces the n = 3 resonant magnetic perturbation (RMP) current threshold for edge-localized mode (ELM) suppression, while co- I p ECCD during the suppressed ELM phase causes a back transition to ELMing. This paper presents nonlinear two-fluid simulations on the ECCD manipulation of edge magnetic islands induced by RMP using the TM1 code. In the presence of a magnetic island chain at the pedestal-top, co- I p ECCD is found to decrease the island width and restore the initially degraded pedestal pressure when its radial deposition location is close to the rational surface of the island. With a sufficiently strong co- I p ECCD current, the RMP-driven magnetic island can be healed, and the pedestal pressure fully recovers to its initial ELMing state. On the contrary, counter- I p ECCD is found to increase the island width and further reduce the pedestal pressure to levels significantly below the peeling-ballooning-mode limited height, leading to even stationary ELM suppression. These simulations align with the results from DIII-D experiments. However, when multiple magnetic island chains are present at the pedestal-top, the ECCD current experiences substantial broadening, and its effects on the island width and pedestal pressure become negligible. Further simulations reveal that counter- I p ECCD enhances RMP penetration by lowering the penetration threshold, with the degree of reduction proportional to the amplitude of ECCD current. For the ∼1 MW ECCD in DIII-D, the predicted decrease in the RMP penetration threshold for ELM suppression is approximately 20%, consistent with experimental observations. These simulations indicate that edge-localized ECCD can be used to either facilitate RMP-driven ELM suppression or optimize the confinement degradation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of dangling bond defects at the crystalline Si/SiO x interface in a polycrystalline Si passivating contact solar cell at room temperature with electrically detected magnetic resonance spectroscopy

Monocrystalline silicon solar cells can achieve photoconversion efficiencies exceeding 26%; however, performance-limiting defects that trap carriers continue to be a challenge. In this work, we have characterized Si solar cells with tunneling SiO x /polycrystalline-Si (poly-Si) passivating contacts (TOPCon) on As-doped Czochralski Si wafers with electrically detected magnetic resonance (EDMR) spectroscopy. We fabricated 2 × 20 mm 2 TOPCon-like mini solar cells with edge passivation alongside larger 4 cm 2 sister cells and obtained similar device characteristics. We performed EDMR spectroscopy at 300 K on two minicells with different degrees of surface passivation based on the recombination parameter, J o , values of 40 and 310 fA/cm2. We optimized the resolution and the signal-to-noise ratio of the EDMR response of the minicells by varying the forward bias voltage and the magnetic field modulation amplitude. We detect two distinct signals with EDMR spectroscopy, an axial-like signal at g = 2.009, 2.0087, and 2.0015, and an isotropic signal at g = 2.0024, which we attribute to Si dangling bonds (P b0 and P b centers) and boron–oxygen related defects, respectively, at or near the c-Si/SiO x interface. The EDMR signals were lower for the cell with a lower value of J o , while the ratio of the two defect populations was very similar. The EDMR signal increases with forward bias but drops to zero at bias voltages >0.5 V, consistent with interface defects within or near the boron-doped emitter depletion region. Our study demonstrates a method to fabricate minicells that can be characterized with EDMR spectroscopy to detect industrially relevant defects in TOPCon cells.

14 SOLAR ENERGY↗

Paramagnetic Mn 8 Fe 4 -co-Polystyrene Nanobeads as a Potential T 1 –T 2 Multimodal Magnetic Resonance Imaging Contrast Agent with In Vivo Studies

In developing a cluster-nanocarrier design, as a magnetic resonance imaging contrast agent, we have investigated the enhanced relaxivity of a manganese and iron-oxo cluster grafted within a porous polystyrene nanobead with increased relaxivity due to a higher surface area. The synthesis of the cluster-nanocarrier for the cluster Mn 8 Fe 4 O 12 (O 2 CC 6 H 4 CH=CH 2 ) 16 (H 2 O) 4 , cross-linked with polystyrene (the nano-carrier), under miniemulsion conditions is described. By including a branched hydrophobe, iso-octane, the resulting nanobeads are porous and similar to 70 nm in diameter. The increased surface area of the nanobeads compared to nonporous nanobeads leads to an enhancement in relaxivity; r 1 increases from 3.8 to 5.2 ± 0.1 mM -1 s -1 , and r 2 increases from 11.9 to 50.1 ± 4.8 mM -1 s -1 , at 9.4 teslas, strengthening the potential for T 1 and T 2 imaging. Several metrics were used to assess stability, and the porosity produced no reduction in metal stability. Synchrotron X-ray fluorescence microscopy was used to demonstrate that the nanobeads remain intact in vivo . In depth, physicochemical characteristics were determined, including extensive pharmacokinetics, in vivo imaging, and systemic biodistribution analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational study of runaway electrons in MST tokamak discharges with applied resonant magnetic perturbation

A numerical study of magnetohydrodynamics (MHD) and tracer-particle evolution investigates the effects of resonant magnetic perturbations (RMPs) on the confinement of runaway electrons (REs) in tokamak discharges conducted in the Madison Symmetric Torus. In computational results of applying RMPs having a broad toroidal spectrum but a single poloidal harmonic, m = 1 RMP does not suppress REs, whereas m = 3 RMP achieves significant deconfinement but not the complete suppression obtained in the experiment. MHD simulations with the NIMROD code produce sawtooth oscillations, and the associated magnetic reconnection can affect the trajectory of REs starting in the core region. Simulations with m = 3 RMP produce chaotic magnetic topology over the outer region, but the m = 1 RMP produces negligible changes in field topology, relative to applying no RMP. Using snapshots of the MHD simulation fields, full-orbit relativistic electron test particle computations with KORC show ≈50% loss from the m = 3 RMP compared to the 10%–15% loss from the m = 1 RMP. Here, test particle computations of the m = 3 RMP in the time-evolving MHD simulation fields show correlation between MHD activity and late-time particle losses, but total electron confinement is similar to computations using magnetic-field snapshots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗