The use of multilayer insulation on the LM vehicle.
Lunar module multilayer radiation insulation for thermal control, testing aluminum coated Mylar and Kapton sheets
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Lunar module multilayer radiation insulation for thermal control, testing aluminum coated Mylar and Kapton sheets
Multilayer insulation of prefabricated panels is developed for cryogenic storage tanks. System utilizes panels of aluminized Mylar separated by sheets of low conductivity polyurethane foam. Panels are self-evacuated by cryopumping of gaseous carbon dioxide at time of use.
Self opening em-operated secondary and ternary mylar diaphragms for expansion tubes and tunnels
Fabric knitted on conventional knitting machines uses commercially available yarns, has high aerodynamic drag capability, and is relatively inexpensive. The two yarn components used are 15-denier nylon monofilament and aluminized Mylar tape.
Self evacuating multilayer insulation system of aluminized Mylar and polyurethane foam for liquid hydrogen tanks
Multilayer composite consisting of alternate spunbond nylon layers and doubly aluminized mylar layers is used primarily in cryogenic thermal protection systems.
Mylar diaphragms in shock tubes are a major improvement over steel diaphragms. Other improvements include: better electrode design; improved flow by opening the throat and removing all constrictions; and improved driver geometry by optimizing volume and shape.
A sonic boom pressure profile was simulated in the far-field by detonation of a methane-oxygen mixture contained in a slender, shaped Mylar envelope. Ideal N-waves were synthesized with peak overpressures from two to five psf and durations of 30 to 75 milliseconds. The detonation of the gas mixture was initiated by a single Primacord strand running the length of balloon. The N-wave producing balloon was synthesized as a composite structure, utilizing experimental pressure profiles obtained from the detonations of slender, axisymmetric balloons with elementary, non-cylindrical shapes.
The electron current drained from a plasma through approximately 0.05 cm diameter holes in eight possible space applicable dielectrics placed on a probe biased at voltages up to 2000 V dc have been determined both theoretically and experimentally. The dielectrics tested were Parylene C and N, Teflon FEP type C, Teflon TFE, Nomex, quartz 7940 Corning Glass, Mylar A, and Kapton H polymide film. A Laplace field was used to predict an upper limit for the drainage current. The measured current was less than the computed current for quartz, Teflon FEP, and the 0.0123 cm thick sample of Parylene N for all voltages tested. The drainage current through the other dielectrics became equal to or greater than the computed current at a voltage below 2000 V. The magnitudes of the currents were between 0.1 and 10 microamperes for most of the dielectrics.
The feasibility of reducing the gas permeability rate of Mylar and Kapton films without drastically effecting their flexibility characteristics at cryogenic temperatures was considered. This feasibility was established using a concept of diffusion bonding two layers of metallized films together forming a film-metal-film sandwich laminate. The permeability of kapton film to gaseous helium was reduced from a nominal ten = to the minus 9 power cc-mm/sq cm sec. cm Hg to ten to the minus 13 power cc-mm/ sq cm - sec. cm Hg with some values as low as ten to the minus 15 power cc - mm/sq cm m-sec - cm Hg being obtained. Similar reductions occurred in the liquid hydrogen permeability at -252 C. In the course of the program the permeability, flexibility and bond strength of plain, metalized and diffusion bond film were determined at +25 C, -195 C and -252 C. The cryogenic flexibility of Kapton film was reduced slightly due to the metallization process but no additional loss in flexibility resulted from the diffusion bonding process.
Results of a test program designed to determine the effects of 100 temperature and compressive loading cycles on several multilayer insulation materials and composites. A total of four reflector materials, four separator materials, eight face-sheet systems, and one fastener material were subjected to 100 temperature cycles from -320 to 400 or 650 F. Generic types of materials studied included Mylar, Kapton, Dacron, Nomex, and Beta Glass. The temperature cycling was followed by visual inspection, metal adhesion tests on the reflectors, and tensile tests of the face sheets, fastener, and separators. A total of six composites were subjected to compressive cycles between zero and 0.15 psi, and density changes were measured. Application of the experimental results to the shuttle orbiter is discussed.
Results of an extensive study conducted to evaluate multilayer insulation (MLI) materials suitable for repeated space vehicle operation are presented. Materials studied were radiation shields, shield spacers, blanket face sheets, fasteners, and adhesives. The Superfloc MLI concept - Kapton shields goldized on both sides as the radiation barrier with Dacron flock tufts as the spacers - appeared to be an excellent MLI for reusable cryogenic tankage. Superfloc configurations consisting of various combinations of film, spacer, and adhesive materials were manufactured and tested. Tensile, flexing, expansion, and cycling tests were performed on goldized Kapton and Mylar Superfloc and Beta glass reinforced Pyre ML face sheet material. A face sheet material that retains its shape was developed. Polyphenylene oxide material was selected for fabricating lightweight twin and tri-pin fasteners, together with grommets, face sheets, and reinforcement slabs. Measured material thermal conductivity values are tabulated.
The effects of spacecraft installation-type discontinuities on aluminized Mylar multilayer insulation have been measured using an electrically heated cylindrical calorimeter. The experimental results have been reproducible within plus or minus 10% or better for identical blankets and less than plus or minus 5% for the same blanket. Good blanket performance can be obtained using short interleaving for joints, eliminating stitched seams, and using small patches, particularly over the hot side of stitches. The heat loss through stitching is excessive but highly localized. Analytical models matched to thermocouple test results are presented. The manner in which radiation and conduction participate in heat transfer adjacent to discontinuities is indicated. High lateral heat transfer is also established as an important phenomenon in the vicinity of a discontinuity.
Report of an observation made with a rocket-borne argon-methane proportional counter, which was equipped with a 'Mylar' window and was sensitive to X rays in the range from 0.2 to 10 keV. During a scan of the galactic plane, the detector passed directly over the location of Cen X-3 at a roll rate of 1 deg per second. An extended minimum of X-ray flux was observed. It is concluded that the anomalous effect is intrinsic to the source.
Specimens of fabric and Mylar were loaded to failure both statically and dynamically. Static tests were accomplished by pressurizing the specimens and dynamic tests were conducted by firing a shock tube. The results of the study indicate that seam efficiency is degraded by dynamic loads and that a need exists to investigate a seaming procedure which gives an optimum dynamic efficiency. The study also illustrates the lack of correspondence between static and dynamic breaking strengths thereby indicating that fabrics which have dynamic applications should be evaluated using dynamic testing procedures such as the shock tube loading used in the present program.
An experimental and analytical investigation of the effect of a circular hole on the buckling of thin cylindrical shells under axial compression was carried out. The experimental results were obtained from tests performed on seamless electroformed copper shells and Mylar shells with a lap joint seam. These results indicated that the character of the shell buckling was dependent on a parameter which is proportional to the hole radius divided by the square root of the product of the shell radius and thickness. For small values of this parameter, there was no apparent effect of the hole on the buckling load. For slightly larger values of the parameter, the shells still buckled into a general collapse configuration, but the buckling loads were sharply reduced as the parameter increased. For still larger values of the parameter, the buckling loads were further reduced, and the shells buckled into a stable local buckling configuration.
Cylindrical drum, wrapped with flexible solar array of solar cells mounted on Mylar sheet, is held by two end-fittings with cable (under tension) passing through axel of drum. Drum is held to end-fittings by axial cable through drum axel; drum is released for deployment when cable is cut at each end and end-fittings spring outward.
The Jimsphere/Jimsonde system is described and some possible applications of the system for air-sea interface measurements are presented. As space vehicles became larger and more sophisticated, an improved method for obtaining wind profile data had to be found. To satisfy this need the FPS-16 radar/Jimsphere system was developed. The Jimsphere is an aluminized mylar spherical balloon, two meters in diameter. The balloon is under superpressure, and is tracked with a high precision radar system. The development of this detailed wind profile system was started in 1963, and the present design was established in 1964. To improve the system, a program was initiated in 1965 to obtain high resolution temperature data simultaneously with the wind profile data.