Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MPC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

THE BARYONIC ACOUSTIC FEATURE AND LARGE-SCALE CLUSTERING IN THE SLOAN DIGITAL SKY SURVEY LUMINOUS RED GALAXY SAMPLE

We examine the correlation function xi of the Sloan Digital Sky Survey Luminous Red Galaxy sample at large scales (60 h {sup -1} Mpc < s < 400 h {sup -1} Mpc) using the final data release (DR7). Focusing on a quasi-volume-limited (0.16 < z < 0.36) subsample and utilizing mock galaxy catalogs, we demonstrate that the observed baryonic acoustic peak and larger scale signal are consistent with LAMBDACDM at 70%-95% confidence. Fitting data to a non-linear, redshift-space, template-based model, we constrain the peak position at s{sub p} = 101.7+- 3.0 h {sup -1} Mpc when fitting the range 60 h {sup -1} Mpc < s < 150 h {sup -1} Mpc (1sigma uncertainties). This redshift-space distance s{sub p} is related to the comoving sound horizon scale r{sub s} after taking into account matter-clustering non-linearities, redshift distortions, and galaxy-clustering bias. Mock catalogs show that the probability that a DR7-sized sample would not have an identifiable peak is at least {approx}10%. As a consistency check of a fiducial cosmology, we use the observed s{sub p} to obtain the distance D{sub V}{identical_to}((1+z){sup 2}D{sup 2}{sub A}cz/H(z)){sup 1/3} relative to the acoustic scale. We find r{sub s} /D{sub V} (z = 0.278) = 0.1389 +- 0.0043. This result is in excellent agreement with Percival et al., who examine roughly the same data set, but use the power spectrum. Comparison with other determinations in the literature are also in very good agreement. The signal of the full sample at 125 h {sup -1} Mpc < s < 200 h {sup -1} Mpc tends to be high relative to theoretical expectations; this slight deviation can probably be attributed to sample variance. We have tested our results against a battery of possible systematic effects, finding all effects are smaller than our estimated sample variance.

79 ASTRONOMY AND ASTROPHYSICS↗

The clustering of galaxies in the SDSS-III Baryon Oscillation Spectroscopic Survey: baryon acoustic oscillations in the correlation function of LOWZ and CMASS galaxies in Data Release 12

In this paper, we present distance scale measurements from the baryon acoustic oscillation signal in the constant stellar mass and low-redshift sample samples from the Data Release 12 of the Baryon Oscillation Spectroscopic Survey. The total volume probed is 14.5 Gpc 3 , a 10 per cent increment from Data Release 11. From an analysis of the spherically averaged correlation function, we infer a distance to z = 0.57 of D V (z)r$fid\atop{d}$ /r d = 2028 ± 21 Mpc and a distance to z = 0.32 of V (z)r$fid\atop{d}$ /r d = 1264 ± 22 Mpc assuming a cosmology in which r$fid\atop{d}$ = 147.10 Mpc. From the anisotropic analysis, we find an angular diameter distance to z = 0.57 of D A (z)r$fid\atop{d}$ /r d = 1401 ± 21 Mpc and a distance to z = 0.32 of 981 ± 20 Mpc, a 1.5 and 2.0 per cent measurement, respectively. The Hubble parameter at z = 0.57 is H(z)r d /r$fid\atop{d}$ = 100.3 ± 3.7kms -1 Mpc -1 and its value at z=0.32 is 79.2±5.6 kms -1 Mpc -1 , a 3.7 and 7.1 per cent measurement, respectively. In conclusion, these cosmic distance scale constraints are in excellent agreement with aΛcold dark matter model with cosmological parameters released by the recent Planck 2015 results.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-F-CAMPUS-J-01: A Novel and Efficient Daily QA Program for Both Modern Linear Accelerator and Optical Surface Motion Systems

Purpose: The camera-based optical surface monitoring system(OSMS) is a standard motion-tracking system for TrueBeam™ machine. Daily quality assurance(DQA) procedures for the TrueBeam and OSMS systems currently require multiple phantoms and test sequences. Machine Performance Check(MPC) uses the IsoCal™ phantom to test geometric and dosimetric aspects, and has been validated for routine TrueBeam DQA. This work examines the novel use of MPC to simultaneously conduct DQA of OSMS,utilizing one phantom and test sequence for QA of both the TrueBeam and OSMS systems. Methods: TrueBeam with 6 degree-of-freedom(6DOF) couch, MPC and OSMS were installed. The therapists routinely use MPC with the IsoCal phantom to verify geometric and dosimetric parameters with an automated sequence of varying gantry and collimator angles, MLC positions, and couch translations and rotations as the DQA for TrueBeam. A surface outline of the IsoCal phantom, generated from a CT dataset, was imported to OSMS and used to monitor the position of the phantom at isocenter and to track its movement up to 5cm/10°(yaw) and rotation in pitch and roll up to 3° in real time during the automated MPC sequence. Motion of the phantom throughout the MPC routine was compared to the couch position shown by the digital readout. Results: The coincidence of isocenter, as determined by OSMS, and TrueBeam radiation isocenter was within ±0.8mm/±0.8° in three axes. Between OSMS and TrueBeam 6DOF couch, the mean couch relative shifts/angles were within ±0.7mm/±0.8° for each axis. Reported pitch and roll values were within ±0.4mm/±0.4°. The total measurement time for each DQA session took approximately 5 minutes. Conclusion: Use of the IsoCal phantom and MPC for simultaneous DQA of TrueBeam and OSMS increases QA efficiency and reduces complexity. OSMS isocenter position and motion-tracking capability in 6DOF were verified in real-time and were found to be within 1mm of the expected value.

60 APPLIED LIFE SCIENCES↗

Ontologies at Work: Analyzing Information Requirements for Model Predictive Control in Buildings

Model Predictive Control (MPC) has shown significant potential for improving energy efficiency, indoor air quality and occupant comfort of buildings. MPC-based control algorithms have also shown the ability to shift loads and optimize for multiple objectives, including but not limited to reducing the green-house gas emissions, energy costs and peak demand. However, one of the main implementation challenges of these control algorithms is the integration and configuration effort needed to deploy a supervisory MPC controller in a building. By assigning standardized references to information sources and control points in buildings, existing studies have shown that semantic ontologies and corresponding queries have the potential to ease the deployment of such controllers. Yet, the use of semantic information to ease the deployment processes of MPC controllers is still limited. In this paper, we review three MPC experiments and synthesize the information requirements of these optimization problems. We then turn to existing and upcoming semantic ontologies such as Brick, SAREF and ASHRAE Standard 223 to represent these requirements, evaluating their potential to support the implementation of an MPC controller. This investigation concludes with a discussion of existing opportunities and open questions that the community should explore to support more streamlined MPC implementations.

Prakash, Anand Krishnan↗

Transient Efficiency Flexibility and Reliability Optimization of Coal-Fired Power Plants: Model-Predictive Control Library Development (Report)

This document pertains to the reporting requirements of DOE contract FE-0031767. The document covers the development of a model predictive control (MPC) library for implementing MPC for a general dynamic system. The library is implemented in a standardized manner in Matlab/Simulink, where core functions on model prediction, linearization and formulation and solution of a quadratic programming (QP) optimization problem is done in the core library - independent of the specific application. The user can provide the application-specific dynamic model in continuous and discrete time, to rapidly implement and test the MPC performance in a desktop simulation. The MPC optimization objective and constraints are also easily configured via an Excel file to allow iterative refinement as needed. Finally, the MPC library enables a rapid deployment to a target environment through auto C-code generation and containerization. The MPC library works seamlessly with the model based estimation (MBE) library to obtain the overall output feedback control solution. In this program, the reduced order model (ROM) of a coal-fired power plant (CFPP) is used to implement and test the MPC solution.

01 COAL, LIGNITE, AND PEAT↗

Analyses of Model-Based Predictive Control for a S-CO 2 Brayton Cycle Power Converter

The supercritical carbon dioxide (S-CO 2 ) Brayton cycle is a promising alternative to steam cycles as an energy converter for advanced nuclear reactors as well as fossil-fired and concentrated solar power plants. For advanced reactors, such as Sodium-cooled Fast Reactors (SFRs), the S-CO 2 cycle offers the benefits of high cycle efficiency, very compact turbomachinery, and elimination of sodium-water reactions, all of which may enable improved economics. The efficiency gains calculated for the S-CO 2 cycle are particularly significant if advantage can be taken of the sharp changes in the carbon dioxide thermo-physical properties near the critical point. On the other hand, the same property variations give rise to challenges in the cycle design, analysis, and control. The onset of two-phase flow (where the minimum cycle temperature and pressure drop drop below the critical value) can degrade compressor performance and potentially cause damage to the compressor blades. In previous work, the feasibility of the Model-based Predictive Control (MPC) approach was assessed for improving regulation of the precooler outlet temperature. A linear reduced-order model for the precooler was generated and for this simplified standalone system operating with an MPC controller the response of outlet temperature was evaluated through simulations. These evaluations included the presence of temperature measurement time delay representing a degraded sensor. It was demonstrated that the MPC controller maintained stable precooler temperature for those delay cases where a proportional-integral controller became unstable. In the present work the simulations have been extended to evaluate the MPC controller operating under more realistic conditions, namely in the split-flow recompression cycle non-linear plant. This compares with the previous standalone reduced-order linear system described above. In the present work the MPC-based control scheme was implemented in a GPASS 1-D systems code representation of the split-flow recompression cycle. The performance of the controller was again investigated for degraded sensor conditions and compared to that of a proportional-integral controller. The results were qualitatively similar to the previous results with the MPC controller and again providing superior stability characteristics. This work provides a sound starting point for the development of model-based control systems. In particular, the MPC control approach applied to Multiple Input Multiple Output systems can be used to synchronize the operation of the different system components to improve control system dynamic performance.

20 FOSSIL-FUELED POWER PLANTS↗

A Model Predictive Control to Improve Grid Resilience

The following article details a model predictive control (MPC) to improve grid resilience when faced with variable generation resources. This topic is of significant interest to utility power systems where distributed intermittent energy sources will increase significantly and be relied on for electric grid ancillary services. Previous work on MPCs has focused on narrowly targeted control applications such as improving electric vehicle (EV) charging infrastructure or reducing the cost of integrating Energy Storage Systems (ESSs) into the grid. In contrast, this article develops a comprehensive treatment of the construction of an MPC tailored to electric grids and then applies it integration of intermittent energy resources. To accomplish this, the following article includes a description of a reduced order model (ROM) of an electric power grid based on a circuit model, an optimization formulation that describes the MPC, a collocation method for solving linear time-dependent differential algebraic equations (DAEs) that result from the ROM, and an overall strategy for iteratively refining the behavior of the MPC. Next, the algorithm is validated using two separate numerical experiments. First, the algorithm is compared to an existing MPC code and the results are verified by a numerically precise simulation. It is shown that this algorithm produces a control comparable to existing algorithms and the behavior of the control carefully respects the bounds specified. Second, the MPC is applied to a small nine bus system that contains a mix of turbine-spinning-machine-based and intermittent generation in order to demonstrate the algorithm’s utility for resource planning and control of intermittent resources. This study demonstrates how the MPC can be tuned to change the behavior of the control, which can then assist with the integration of intermittent resources into the grid. The emphasis throughout the paper is to provide systematic treatment of the topic and produce a novel nonlinear control compatible design framework applicable to electric grids and the control of variable resources. This differs from the more targeted application-based focus in most presentations.

microgrid↗

Summary

An effective risk assessment system is needed to address the threat posed by an active or passive insider who, acting alone or in collusion, could attempt diversion or theft of nuclear material. The material control and accountability (MC&A) system effectiveness tool (MSET) is a self-assessment or inspection tool utilizing probabilistic risk assessment (PRA) methodology to calculate the system effectiveness of a nuclear facility's material protection, control, and accountability (MPC&A) system. The MSET process is divided into four distinct and separate parts: (1) Completion of the questionnaire that assembles information about the operations of every aspect of the MPC&A system; (2) Conversion of questionnaire data into numeric values associated with risk; (3) Analysis of the numeric data utilizing the MPC&A fault tree and the SAPHIRE computer software; and (4) Self-assessment using the MSET reports to perform the effectiveness evaluation of the facility's MPC&A system. The process should lead to confirmation that mitigating features of the system effectively minimize the threat, or it could lead to the conclusion that system improvements or upgrades are necessary to achieve acceptable protection against the threat. If the need for system improvements or upgrades is indicated when the system is analyzed, MSET provides the capability to evaluate potential or actual system improvements or upgrades. A facility's MC&A system can be evaluated at a point in time. The system can be reevaluated after upgrades are implemented or after other system changes occur. The total system or specific subareas within the system can be evaluated. Areas of potential system improvement can be assessed to determine where the most beneficial and cost-effective improvements should be made. Analyses of risk importance factors show that sustainability is essential for optimal performance and reveals where performance degradation has the greatest impact on total system risk. The risk importance factors show the amount of risk reduction achievable with potential upgrades and the amount of risk reduction achieved after upgrades are completed. Applying the risk assessment tool gives support to budget prioritization by showing where budget support levels must be sustained for MC&A functions most important to risk. Results of the risk assessment are also useful in supporting funding justifications for system improvements that significantly reduce system risk. The functional model, the system risk assessment tool, and the facility evaluation questionnaire are valuable educational tools for MPC&A personnel. These educational tools provide a framework for ongoing dialogue between organizations regarding the design, development, implementation, operation, assessment, and sustainability of MPC&A systems. An organization considering the use of MSET as an analytical tool for evaluating the effectiveness of its MPC&A system will benefit from conducting a complete MSET exercise at an existing nuclear facility.

99 GENERAL AND MISCELLANEOUS↗

Dynamic Control of Sodium Cold Trap Purification Temperature Using LSTM System Identification

This study investigates the dynamic regulation of the sodium cold trap purification temperature at Argonne National Laboratory’s liquid sodium test facility, employing long short-term memory (LSTM) system identification techniques. The investigation introduces an innovative hybrid approach by integrating model predictive control (MPC) based on first principles dynamic models with a multi-step time–frequency LSTM model in predicting the temperature profiles of a sodium cold trap purification system. The long short-term memory–model predictive controller (LSTM-MPC) model employs a sliding window scheme to gather training samples for multi-step prediction, leveraging historical data to construct predictive models that capture the non-linearities of the complex system dynamics without explicitly modeling the underlying physical processes. The performance of the LSTM-MPC and MPC were evaluated through simulation experiments, where both models were assessed on their capacity to maintain the cold trap temperature within predefined set-points while minimizing deviations and overshoots. Results obtained show how the data-driven LSTM-MPC model demonstrates stability and adaptability. In contrast, the traditional MPC model exhibits irregularities, particularly evident as overshoots around set-point limits, which can potentially compromise its effectiveness over long prediction time intervals. The findings obtained offer valuable insights into integrating data-driven techniques for enhancing real-time monitoring systems.

LSTM-MPC↗

Simulation-based Performance Evaluation of Model Predictive Control for Building Energy Systems

The performance of model predictive control (MPC) can be significantly affected by different choices of controller parameters such as the time intervals for model discretization and control sampling. Due to the lack of a systematic understanding on how these parameters affect control performance, they are usually selected arbitrarily in practice.In this paper, the combined impacts of selected time intervals for model discretization and control sampling on the performance of MPC are comprehensively investigated for the first time through detailed simulations. Specifically, a typical MPC strategy is first designed to improve building operations based on a reduced-order model of building dynamics. Then, the performance of the designed MPC is evaluated against different choices of time intervals for model discretization and control sampling on a simulated office building. The detailed simulation results reveal that the time interval for model discretization has a much greater influence on the performance of MPC than the time interval for control sampling. Although the time interval for control sampling usually receives more attentions in practice, it turns out that the time interval for model discretization affects the prediction performance, cost saving, and computation time simultaneously and more significantly. Therefore, the simulation-based performance evaluation presented here sheds light on the impacts of different time intervals and facilitates their selection for practical applications of MPC to building operations

Huang, Sen↗

Reinforcement learning for online adaptation of model predictive controllers: Application to a selective catalytic reduction unit

Here we present a novel application of reinforcement learning (RL) for online dynamic tuning of model predictive controllers (MPC). Applying a state-action-reward-state-action (SARSA) algorithm for temporal difference learning with a control-specific reward function improves the error tracking performance of a standard MPC formulation. The proposed RL approach is also readily adaptable to other MPCs, or entirely different control approaches. Practical details for the implementation of the RL-MPC algorithm are also presented. The proposed algorithm is applied to a case study of controlling nitrogen oxide (NO x ) emissions in an industrial selective catalytic reduction (SCR) unit, a control problem characterized by significant nonlinearity and time delay. Along with an RL-MPC formulation for NOx control, another MPC is proposed to mitigate ammonia slip and decrease ammonia consumption in the SCR. Results showing the efficacy of the RL-MPC for NO x control through learning and implementation on the nonlinear SCR dynamic model are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

Multiscale model predictive control of battery systems for frequency regulation markets using physics-based models

In this work, we propose a multiscale model predictive control (MPC) framework for stationary battery systems that exploits high-fidelity models to trade-off short-term economic incentives provided by energy and frequency regulation (FR) markets and long-term degradation effects. We find that the MPC framework can drastically reduce long-term degradation while properly responding to FR and energy market signals (compared to MPC formulations that use low-fidelity models). Our results also provide evidence that sophisticated battery models can be embedded within closed-loop MPC simulations by using modern nonlinear programming solvers (we provide an efficient and easy-to-use implementation in Julia). We use insights obtained with our simulations to design a low-complexity MPC formulation that matches the behavior obtained with high-fidelity models. This is done by designing a suitable terminal penalty term that implicitly captures long-term degradation. The results suggest that complex degradation behavior can be accounted for in low-complexity MPC formulations by properly designing the cost function. We believe that our proof-of-concept results can be of industrial relevance, as battery vendors are seeking to participate in fast-changing electricity markets while maintaining asset integrity.

42 ENGINEERING↗

Virtual storage capability of residential buildings for sustainable smart city via model-based predictive control

This paper evaluates the virtual storage capability of a residential air-conditioning (AC) system by utilizing the building mass as a thermal storage to enable sustainable cities through model-based predictive control (MPC). The control-oriented building model was developed with a grey-box model structure based on the experimental data to predict the indoor air temperature. Based on the model, the operation cost-saving potential of the MPC was investigated in a single house with different comfort levels, electricity prices, and prediction horizons. The cost-saving of the MPC was approximately 10.6 % compared to the conventional control. The MPC was expanded to a residential building cluster considering the peak demand charge. In an hourly shedding and load-up scenario, the performances of the MPC and the heuristic prior-based control (PBC) are promising. When shedding was enforced all day, the peak demand saving of the MPC was 36~38 %, whereas that of the PBC was 25.7 % compared to the baseline. In addition, the monthly electricity bill, including the operation and peak demand cost, was investigated with different demand charge rates and weather conditions. The total saving decreased with a low demand charge rate and hot conditions, and the operation cost saving was compromised with more aggressive demand shedding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ligand-Enhanced Optical Response of Gold Nanomolecules and Its Fragment Projection Analysis: The Case of Au 30 (SR) 18

We investigate via first-principles simulations the optical absorption spectra of three different Au 30 (SR) 18 monolayer-protected clusters (MPC): Au 30 (StBu) 18 , Au 30 (SPh) 18 , and Au 30 (SPh-pNO 2 ) 18 . Au 30 (StBu) 18 is known in the literature, and its crystal structure is available. In contrast, Au 30 (SPh) 18 and Au 30 (SPh-pNO 2 ) 18 are two species that have been designed by replacing the tert-butyl organic residues of Au 30 (StBu) 18 with aromatic ones so as to investigate the effects of ligand replacement on the optical response of Au nanomolecules. By analogy to a previously studied Au 23 (SR)16– anionic species, despite distinct differences in charge and chemical composition, a substantial ligand enhancement of the absorption intensity in the optical region is also obtained for the Au 30 (SPh-pNO 2 ) 18 MPC. Furthermore, the use of conjugated aromatic ligands with properly chosen electron-withdrawing substituents and exhibiting steric hindrance so as to also achieve charge decompression at the surface is therefore demonstrated as a general approach to enhancing the MPC photoabsorption intensity in the optical region. In addition, we here subject the ligand-enhancement phenomenon to a detailed analysis based on the fragment projection of electronic excited states and on induced transition densities, leading to a better understanding of the physical origin of this phenomenon, thus opening avenues to its more precise control and exploitation.

36 MATERIALS SCIENCE↗

Architecture-Guided Fluid Flow Directs Renal Biomineralization

Nephrocalcinosis often begins on a calcium phosphate deposit, at the tip of the medullo-papillary complex (MPC) known as Randall’s plaque (RP). Contextualizing proximally observed biominerals within the MPC has led us to postulate a mechanobiological switch that can trigger interstitial biomineralization at the MPC tip, remote from the intratubular biominerals. Micro X-ray computed tomography scans of human MPCs correlated with transmission and scanning electron micrographs, and X-ray energy dispersive spectrometry demonstrated novel findings about anatomically-specific biominerals. An abundance of proximal intratubular biominerals were associated with emergence of distal interstitial RP. The fundamental architecture of the MPC and mineral densities at the proximal and distal locations of the MPC differed markedly. A predominance of plate-like minerals or radially oriented plate-like crystallites within spheroidal minerals in the proximal intratubular locations, and core-shell type crystallites within spheroidal minerals in distal interstitial locations were observed. Based on the MPC anatomic location of structure-specific biominerals, a biological switch within the mineral-free zone occurring between the proximal and distal locations is postulated. The “on” and “off” switch is dependent on changes in the pressure differential resulting from changes in tubule diameters; the “Venturi effect” changes the “circumferential strain” and culminates in interstitial crystal deposits in the distal tubule wall in response to proximal tubular obstruction. These distal interstitial mineralizations can emerge into the collecting system of the kidney linking nephrocalcinosis with nephrolithiasis.

59 BASIC BIOLOGICAL SCIENCES↗

TDCOSMO. XII. Improved Hubble constant measurement from lensing time delays using spatially resolved stellar kinematics of the lens galaxy

Strong-lensing time delays enable measurement of the Hubble constant ($H_{0}$) independently of other traditional methods. The main limitation to the precision of time-delay cosmography is mass-sheet degeneracy (MSD). Some of the previous TDCOSMO analyses broke the MSD by making standard assumptions about the mass density profile of the lens galaxy, reaching 2% precision from seven lenses. However, this approach could potentially bias the $H_0$ measurement or underestimate the errors. For this work, we broke the MSD for the first time using spatially resolved kinematics of the lens galaxy in RXJ1131$-$1231 obtained from the Keck Cosmic Web Imager spectroscopy, in combination with previously published time delay and lens models derived from Hubble Space Telescope imaging. This approach allowed us to robustly estimate $H_0$, effectively implementing a maximally flexible mass model. Following a blind analysis, we estimated the angular diameter distance to the lens galaxy $D_{\rm d} = 865_{-81}^{+85}$ Mpc and the time-delay distance $D_{\Delta t} = 2180_{-271}^{+472}$ Mpc, giving $H_0 = 77.1_{-7.1}^{+7.3}$ km s$^{-1}$ Mpc$^{-1}$ - for a flat $\Lambda$ cold dark matter cosmology. The error budget accounts for all uncertainties, including the MSD inherent to the lens mass profile and the line-of-sight effects, and those related to the mass-anisotropy degeneracy and projection effects. Our new measurement is in excellent agreement with those obtained in the past using standard simply parametrized mass profiles for this single system ($H_0 = 78.3^{+3.4}_{-3.3}$ km s$^{-1}$ Mpc$^{-1}$) and for seven lenses ($H_0 = 74.2_{-1.6}^{+1.6}$ km s$^{-1}$ Mpc$^{-1}$), or for seven lenses using single-aperture kinematics and the same maximally flexible models used by us ($H_0 = 73.3^{+5.8}_{-5.8}$ km s$^{-1}$ Mpc$^{-1}$). This agreement corroborates the methodology of time-delay cosmography.

79 ASTRONOMY AND ASTROPHYSICS↗