Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSPHERES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Validation of fluorescent-labeled microspheres for measurement of relative blood flow in severely injured lungs

The aim of the study was to validate a nonradioactive method for relative blood flow measurements in severely injured lungs that avoids labor-intensive tissue processing. The use of fluorescent-labeled microspheres was compared with the standard radiolabeled-microsphere method. In seven sheep, lung injury was established by using oleic acid. Five pairs of radio- and fluorescent-labeled microspheres were injected before and after established lung injury. Across all animals, 175 pieces were selected randomly. The radioactivity of each piece was determined by using a scintillation counter. The fluorescent dye was extracted from each piece with a solvent without digestion or filtering. The fluorescence was determined with an automated fluorescent spectrophotometer. Perfusion was calculated for each piece from both the radioactivity and fluorescence and volume normalized. Correlations between flow determined by the two methods were in the range from 0.987 +/- 0.007 (SD) to 0.991 +/- 0.002 (SD) after 9 days of soaking. Thus the fluorescent microsphere technique is a valuable tool for investigating regional perfusion in severely injured lungs and can replace radioactivity.

Non-NASA Center↗

Evaluation of recycle pathways for out-of-specification uranium microspheres from the internal gelation process

During the production of uranium oxide microspheres with carbon using internal gelation, a small fraction of microspheres will not meet the required size or sphericity specification. The uranium microspheres with carbon can be rejected after they have been air-dried or converted into uranium carbide and uranium oxide (UCO) kernels. The next step for the rejected spheres was an air oxidation for carbon removal. The air-dried spheres became triuranium octoxide (U 3 O 8 ) spheres, which were sometimes ground into powder. The UCO kernels became U 3 O 8 powder during the air oxidation. The next recycle step was nitric acid dissolution of the U 3 O 8 spheres or powders to produce acid-deficient uranyl nitrate (ADUN) solutions, which were used to make new uranium oxide microspheres with carbon and subsequently UCO kernels. Finaly, the kinetics of the acid dissolution process were compared, and the impurity levels in the different ADUN solutions were determined. X-ray diffraction results for the UCO kernels from the initial and recycled ADUN solutions indicate that changes in the impurity levels can impact the uranium carbide to uranium dicarbide ratio in the UCO kernels.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Self-Templated Formation of P2-type K 0.6 CoO 2 Microspheres for High Reversible Potassium-Ion Batteries

We report that layered metal oxides have been widely used as the best cathode materials for commercial lithium-ion batteries and are being intensively explored for sodium-ion batteries. However, their application to potassium-ion batteries (PIBs) is hampered because of the poor cycling stability and low rate capability due to the larger ionic size of K + than of Li + or Na + . Herein, a facile self-templated strategy was used to synthesize unique P2-type K 0.6 CoO 2 microspheres that consist of aggregated primary nanoplates as PIB cathodes. The unique K 0.6 CoO 2 microspheres with aggregated structure significantly enhanced the kinetics of the K + intercalation/deintercation and also minimized the parasitic reactions between the electrolyte and K 0.6 CoO 2 . The P2-K 0.6 CoO 2 microspheres demonstrated a high reversible capacity of 82 mAh g –1 at 10 mA g –1 , high rate capability of 65 mAh g –1 at 100 mA g –1 , and long cycle life (87% capacity retention over 300 cycles). The high reversibility of the P2-K 0.6 CoO 2 full cell paired with a hard carbon anode further demonstrated the feasibility of PIBs. Lastly, this work not only successfully demonstrates exceptional performance of P2-type K 0.6 CoO 2 cathodes and microspheres K 0.6 CoO 2 ∥hard carbon full cells, but also provides new insights into the exploration of other layered metal oxides for PIBs.

25 ENERGY STORAGE↗

Frequency comb generation in WGM microsphere based generators for telecommunication applications

We review the frequency comb generation process, main microresonator parameters such as free spectral range (FSR) and Q-factor, previously used optical frequency comb (OFC) generator parameters and resulting frequency combs, as well as the implementation of OFC for optical data transmission. An optical frequency comb is produced in a setup based on a tapered fibre and a SiO{sub 2} microsphere. The generated frequency comb has a frequency spacing of 2 nm or 257 GHz. During the fabrication of a tapered fibre from SMF28, use is made of the transmission signal to control the taper pulling process. The final measured tapered fibre transmission is ∼96%. A microsphere whispering gallery-mode resonator (WGMR), exhibiting a Q-factor of at least 2 × 10{sup 7}, is fabricated from an optical fibre with a thicker core than SSMF. Moreover, for future experiments, a frequency comb generator based on a free-space setup consisting of lenses, a prism, and a microsphere is developed, and the Q-factor dependence on different distances between the prism and the microsphere is investigated. (optical components of fibre-optic communication lines)

36 MATERIALS SCIENCE↗

Metallic Coating of Cerium Oxide Microspheres

The ability to remove heat is paramount to nuclear fuel performance and longevity. Retaining fission product and separating fuel from reactor coolant and the environment is also necessary to prevent radiological contamination. Conventional nuclear fuel for commercial light water reactors and radioisotope power systems (RPS) is composed of oxide powders pressed into a pellet (cm-scale) and then sealed into a metal cladding to confine the fuel. What typical fuels lack is a method to surround each particle of nuclear fuel in metal, thus providing a more intimate protection layer for accident tolerance and boosting the thermal extraction from the fuel element. In such a way, metal-coated fuel particles increase heat extraction efficiency over clad-pellet designs while increasing the accident tolerance of the fuel. Metal oxide microspheres have wide-ranging applications, including the realm of fuels for nuclear reactors and RPS. Microspheres of uranium oxide/uranium carbide, mixed uranium/plutonium oxides, transuranics, and thorium fuels have been extensively studied. Pacific Northwest National Laboratory has also demonstrated the production of 238 PuO 2 microspheres for RPS applications. Metal-coated oxide microsphere fuels may also be attractive for other applications such as nuclear thermal rockets, future nuclear reactor designs, and catalysts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synthesis and characterization of monodisperse magnetite hollow microspheres

Monodisperse hollow magnetite microspheres were successfully synthesized by an one-step process through a template-free hydrothermal approach employing simultaneously a mixture of FeCl 3 ·6H 2 O and ferrocene as precursor and a propylene glycol-isopropanol mixture as solvent. The morphologies and properties of the magnetite microspheres were characterized by X-ray diffraction (XRD), Raman and infrared spectroscopy, field emission scanning electron microscopy (FE-SEM), X-ray photoelectron spectroscopy (XPS), adsorption of nitrogen (BET method) and SQUID magnetometry. The results show that the microspheres consist of a single crystalline phase of magnetite. Furthermore, the size and the internal hollow of the microspheres depend on the temperature of growth and can be tuned by modifying the synthesis conditions.

36 MATERIALS SCIENCE↗

Melanoidin and aldocyanoin microspheres - Implications for chemical evolution and early Precambrian micropaleontology

Two new classes of organic microspheres are described. One of them (melanoidin) is synthesized from amino acids and sugars in heated aqueous solutions. The other (aldocyanoin) is formed in aqueous solutions of ammonium cyanide and formaldehyde at room temperature. The general properties of these microspheres, including conditions of synthesis, size and shape, mechanical and pH stability, and solubility, are compared with corresponding properties of other protocell model systems. It is concluded that melanoidin and aldocyanoin microspheres are plausible candidates for precellular units in the primitive hydrosphere. Since the bulk of the organic carbon in early Precambrian sediments is insoluble kerogen-melanoidin, it is suggested that some Precambrian microfossils may be abiotic melanoidin microspheres.

Kenyon, D. H.↗

Properties and applications of a pitch carbon microsphere composite

Some properties and applications of a pitch carbon microsphere composite are described. The small hollow microspheres are made from the pitch which is usually a wasted by-product of petroleum refining. In contrast to high density composites or syntactic foams in which microspheres are inclusions within a continuous matrix, this composite is an aggregate of microspheres bonded together by a small amount of thermosetting polymer which does not form a continuous matrix. The result is a composite with low density and thermal expansion, modest strength and rigidity, and high porosity and carbon content. Mechanical, thermal, and sorption properties have been measured. Applications of the composite include honeycomb filler for high temperature or ionizing radiation fields and a wicking absorber for solar-powered stills.

Price, H. L.↗

Coupling Light from a High-Q Microsphere Resonator Using a UV-induced Surface Grating

High-Q microspheres with whispering-gallery modes have very narrow resonances that can be used for fiber-optic filters, ultra-compact narrow-linewidth lasers and optical/microwave oscillators. Whispering-gallery modes were previously excited in microspheres using evanescent optical fields. The necessary phase synchronism was obtained by adjusting the incident angle of input light beam (prism coupler) or adjustment of the waveguide propagation constant (fiber taper coupler). For many applications, however, bulky near-field couplers are undesirable. They compromise the symmetry and generate stray fields. Also, the control of coupling is crucial for the performance of microsphere resonators: in analogy with radio frequency circuits, the loading Q-factor should be less than the intrinsic Q-factor, Q(sub L) less than or equal to Q(sub O). Ideally one should combine a stable coupling element and a resonator into a single microsphere component.

Ilchenko, V. S.↗

Microspheres in Plasma Display Panels

Filling small bubbles of molten glass with gases is just as difficult as it sounds, but the technical staff at NASA is not known to shy away from a difficult task. When Microsphere Systems, Inc. (MSI), of Ypsilanti, Michigan, and Imaging Systems Technology, Inc. (IST), of Toledo, Ohio, were trying to push the limits of plasma displays but were having difficulty with the designs, NASA s Glenn Garrett Morgan Commercialization Initiative (GMCI) assembled key personnel at Glenn Research Center and Ohio State University for a brainstorming session to come up with a solution for the companies. They needed a system that could produce hollow, glass micro-sized spheres (microspheres) that could be filled with a variety of gasses. But the extremely high temperature required to force the micro-sized glass bubbles to form at the tip of a metal nozzle resulted in severe discoloration of the microspheres. After countless experiments on various glass-metal combinations, they had turned to the GMCI for help. NASA experts in advanced metals, ceramics, and glass concluded that a new design approach was necessary. The team determined that what was needed was a phosphate glass composition that would remain transparent, and they went to work on a solution. Six weeks later, using the design tips from the NASA team, Tim Henderson, president of MSI, had designed a new system in which all surfaces in contact with the molten glass would be ceramic instead of metal. Meanwhile, IST was able to complete a Phase I Small Business Innovation Research (SBIR) grant supported by the National Science Foundation (NSF) and supply a potential customer with samples of the microspheres for evaluation as filler materials for high-performance insulations.

Source record↗

Coupling system to a microsphere cavity

A system of coupling optical energy in a waveguide mode, into a resonator that operates in a whispering gallery mode. A first part of the operation uses a fiber in its waveguide mode to couple information into a resonator e.g. a microsphere. The fiber is cleaved at an angle .PHI. which causes total internal reflection within the fiber. The energy in the fiber then forms an evanescent field and a microsphere is placed in the area of the evanescent field. If the microsphere resonance is resonant with energy in the fiber, then the information in the fiber is effectively transferred to the microsphere.

Iltchenko, Vladimir↗

Coupling system to a microsphere cavity

A system of coupling optical energy in a waveguide mode, into a resonator that operates in a whispering gallery mode. A first part of the operation uses a fiber in its waveguide mode to couple information into a resonator e.g. a microsphere. The fiber is cleaved at an angle .PHI. which causes total internal reflection within the fiber. The energy in the fiber then forms an evanescent field and a microsphere is placed in the area of the evanescent field. If the microsphere resonance is resonant with energy in the fiber, then the information in the fiber is effectively transferred to the microsphere.

Iltchenko, Vladimir↗

Fabrication of Cerium Oxide and Uranium Oxide Microspheres for Space Nuclear Power Applications

Cerium oxide and uranium oxide microspheres are being produced via an internal gelation sol-gel method to investigate alternative fabrication routes for space nuclear fuels. Depleted uranium and non-radioactive cerium are being utilized as surrogates for plutonium-238 (Pu-238) used in radioisotope thermoelectric generators and for enriched uranium required by nuclear thermal rockets. While current methods used to produce Pu-238 fuels at Los Alamos National Laboratory (LANL) involve the generation of fine powders that pose a respiratory hazard and have a propensity to contaminate glove boxes, the sol-gel route allows for the generation of oxide microsphere fuels through an aqueous route. The sol-gel method does not generate fine powders and may require fewer processing steps than the LANL method with less operator handling. High-quality cerium dioxide microspheres have been fabricated in the desired size range and equipment is being prepared to establish a uranium dioxide microsphere production capability.

07 ISOTOPE AND RADIATION SOURCES↗

Space-Confined Polymerization: Controlled Fabrication of Nitrogen-Doped Polymer and Carbon Microspheres with Refined Hierarchical Architectures

The construction of refined architectures plays a crucial role in performance improvement and application expansion of advanced materials. The synthesis of carbon microspheres with a refined hierarchical structure is still a problem in synthetic methodology, because it is difficult to achieve the necessary delicate control of the interior structure and outer shell across the microscale to nanoscale. Nitrogen-doped multichamber carbon (MCC) microspheres with a refined hierarchical structure are realized here via a surfactant-directed space-confined polymerization strategy. The MCC precursor is not the traditional phenolic resol but a new kind of 2,6-diaminopyridine-based multichamber polymer (MCP) with a high nitrogen content up to 20 wt%. The morphology and sizes of MCP microspheres can be easily controlled by a dual-surfactant system. The as-synthesized MCC with a highly microporous shell, a multichamber inner core, and beneficial N-doping can serve as a promising supercapacitor material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transcatheter Arterial Chemoembolization with Epirubicin-Loaded Superabsorbent Polymer Microspheres for 135 Hepatocellular Carcinoma Patients: Single-Center Experience

Purpose: To evaluate the safety, clinical outcomes, and hepatic artery damage after transcatheter arterial chemoembolization (TACE) with epirubicin-loaded superabsorbent polymer microspheres (ELM-TACE) in patients with hepatocellular carcinoma (HCC) in a single center in Japan. Materials and Methods: This embolic agent is the original form of microspheres, which has the same composition and nature as HepaSpheres. Between May 2007 and June 2009, 135 patients with unresectable HCC who underwent ELM-TACE were enrolled. Embolization through extrahepatic collaterals was performed in 27 (20.0%) patients. Tumor response was evaluated using European Association for the Study of the Liver criteria at 1 and 6 months after initial ELM-TACE. Results: All procedures were successfully performed. The median number of TACE per patient was 1.7 sessions (range 1-5), and the mean epirubicin dose per session was 19.7 mg (range 2.0-60.0). Local pooling within target tumors was observed during TACE in 34 (25.2%) patients, and in 14 (10.4%) of the patients, gelatin sponge particles were added after the microspheres until each pooling disappeared. No serious adverse events associated with TACE occurred, and the incidence of postembolization syndrome was {<=}17.8%. The 1- and 6-month tumor response rates were 56.3 and 52.6%, respectively. The overall 1- and 2-year survival rates were 73.7 and 59.0%, respectively. Among 99 evaluated patients, 90 (90.9%) were found to have no hepatic artery damage after initial ELM-TACE. Conclusion: ELM-TACE is safe and effective treatment for unresectable HCC and is associated with low frequency of postembolization syndrome and minimal damage to the hepatic artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Study Using 100–300 Versus 300–500 μm Microspheres for Symptomatic Patients Due to Enlarged-BPH Prostates

PurposeThe purpose of the study was to compare safety and efficacy outcomes following prostate artery embolization (PAE) for the treatment of lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH) with 100–300 versus 300–500 μm tris-acryl gelatin microspheres.Materials and MethodsPatients were prospectively treated between August 2011 and June 2013 to receive PAE with 100–300 μm (group A) or 300–500 μm (group B) tris-acryl gelatin microspheres. Patients were followed for a minimum of 12 months and were assessed for changes in International Prostate Symptom Score (IPSS), quality of life (QoL) index, prostate volume determined by magnetic resonance imaging, serum prostate specific antigen (PSA), and maximum urine flow rate (Q{sub max}), as well as any treatment-related adverse events.ResultsFifteen patients were included in each group, and PAE was technically successful in all cases. Both groups experienced significant improvement in mean IPSS, QoL, prostate volume, PSA, and Q{sub max} (p < 0.05 for all). The differences observed between the two groups included a marginally insignificant more adverse events (p = 0.066) and greater mean serum PSA reduction at 3 months of follow-up (p = 0.056) in group A.ConclusionsBoth 100–300 and 300–500 μm microspheres are safe and effective embolic agents for PAE to treat LUTS-related to BPH. Although functional and imaging outcomes did not differ significantly following use of the two embolic sizes, the greater incidence of adverse events with 100–300 μm microspheres suggests that 300–500 μm embolic materials may be more appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 90}Y Resin Microspheres Radioembolization for Colon Cancer Liver Metastases Using Full-Strength Contrast Material

ObjectivesTo assess safety and efficacy of {sup 90}Y resin microspheres administration using undiluted non-ionic contrast material (UDCM) {100% Omnipaque-300 (Iohexol)} in both the “B” and “D” lines.Materials and methodsWe reviewed all colorectal cancer liver metastases patients treated with {sup 90}Y resin microspheres radioembolization (RAE) from 2009 to 2017. As of April 2013, two experienced operators started using UDCM (study group) instead of standard sandwich infusion (control group). Occurrence of myelosuppression (leukopenia, neutropenia, erythrocytopenia or/and thrombocytopenia), stasis, nontarget delivery (NTD), median fluoroscopy radiation dose (FRD), median infusion time (IT), liver progression-free (LPFS) and overall survivals (OS) was evaluated. Complications within 6 months post-RAE were reported according to CTCAE v3.0 criteria.ResultsStudy and control groups comprised 23(28%) and 58(72%) patients, respectively. Median follow-up was 9.1 months. There was no statistically significant difference in myelosuppression incidence within 6 months post-RAE between groups. Median FRD and IT for study and control groups were 44.6 vs. 97.35 Gy/cm{sup 2} (p = 0.048) and 31 vs. 39 min (p = 0.006), respectively. A 38% lower stasis incidence in study group was not significant (p = 0.34). NTD occurred in 1/27(4%) study vs. 5/73(7%) control group procedures (p = 1). Grade 1–2 and grade 3–4 toxicities between study and control group patients were 36%(8/22) vs. 45%(26/58), p = 0.61 and 9%(2/22) vs. 16%(9/58), p = 0.72, respectively. There was no difference in LPFS and OS between groups.ConclusionAdministration of {sup 90}Y resin microspheres using UDCM in both lines is safe and effective, resulting in lower fluoroscopy radiation dose and shorter infusion time, without evidence of myelosuppression or increased stasis incidence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

End-hole Versus Microvalve Infusion Catheters in Patients Undergoing Drug-Eluting Microspheres-TACE for Solitary Hepatocellular Carcinoma Tumors: A Retrospective Analysis

Introduction: Pre-transplant locoregional therapy for hepatocellular carcinoma (HCC) during bridge-to-transplant impacts recurrence and survival rates following liver transplantation. Optimizing the effectiveness of transarterial chemoembolization (TACE) in this population is imperative, and microvalve infusion catheters offer a means of such improvement. Methods: All treatment-naive patients with solitary HCC tumors < 6.5 cm who underwent drug-eluting microspheres (DEM) TACE between 04/2015 and 08/2017 were retrospectively reviewed. Eighty-eight included patients underwent DEM-TACE with either standard end-hole catheters (EH) or microvalve infusion catheters (MVI). The EH (n = 70) and MVI (n = 18) cohorts had similar baseline tumor size, laboratory values, and tumor etiologies. Results: Initial objective response rates were significantly higher in MVI vs. EH (100% vs. 76.5%, p = 0.019). There was no difference in adverse events between groups (p = 0.265). MVI patients exhibited lower AST (p = 0.003) and ALT (p = 0.044) at 6 months. Blinded pathological analysis of explanted livers showed greater concentrations of microspheres within the tumor relative to the surrounding tissue in MVI explants (88.7 ± 10.6%) versus the EH explants (55.3 ± 32.7%) (p = 0.002). There was significantly higher percentage tumor necrosis in the MVI group (89.0 ± 2.2%) compared with the EH group (56.1 ± 44.5%) (p = 0.006). Conclusion: In this retrospective study of a single-center cohort, DEM-TACE procedures with MVI were associated with improved tumor response, increased deposition of microspheres within tumor tissue, and higher percentage tumor necrosis at explant relative to those performed using EH catheters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗