Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEV RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Plasma wave undulator for laser-accelerated electrons

Laser-plasma accelerators have become compact sources of ultrashort electron bunches at energies up to the gigaelectronvolt range thanks to the remarkable progress made over the past decade. A direct application of these electron bunches is the production of short pulse x-ray radiation sources. In this letter, we study a fully optically driven x-ray source based on the combination of a laser-plasma accelerator and a plasma wave undulator. The longitudinal electric field of a laser-generated plasma wave is used to wiggle electrons transversally. The period of this plasma undulator being equal to the plasma wavelength, tunable photon energies in the 10 keV range can be achieved with electron energies in the 100-200 MeV range. Considering a 10s TW class femtosecond laser system, undulators with a strength parameter K{approx}0.5 and with about ten periods can be combined with a laser-plasma accelerator, resulting in several 10{sup -2} emitted x-ray photons per electron.

43 PARTICLE ACCELERATORS↗

All-Sky Medium-Energy Gamma-Ray Observatory (AMEGO)

The gamma-ray energy range from a few hundred keV (kiloelectronvolts) to a few hundred MeV (megaelectronvolts) has remained largely unexplored since the pioneering but limited observations by COMPTEL (The Imaging Compton Telescope) on the CGRO (Compton Gamma Ray Observatory) (1991-2000). Fundamental astrophysics questions can be addressed by a mission in the MeV range, from astrophysical jets and extreme physics of compact objects to a large population of unidentified objects. Such a mission will also provide critical inputs for multimessenger astrophysics by identifying and exploring the astrophysical objects that produce gravitational waves and neutrinos. To address these questions, we are developing AMEGO: All-sky Medium Energy Gamma-ray Observatory, as a NASA probe-class mission, to investigate the energy range from 200 keV to greater than10 GeV with good energy (ranging from less than 1 percent at the low end to approximately 10 percent at the high end) and angular resolution (from 2 to 6 degrees depending on energy) and with sensitivity a factor of 20-50 better than previous instruments. Measurements at these energies are challenging, mainly due to the fact that two photon interaction processes, Compton scattering and pair production, compete. These interaction processes require different approaches in both detection and data analysis, and consequently in the instrument concept. AMEGO will be capable of measuring both Compton-scattering events at lower energies and pair-production events at higher energies. AMEGO will also have sensitivity to linear polarization of detected radiation at a level of 20 percent minimum detectable polarization from a source 1 percent of the Crab intensity, observed for 106 seconds. AMEGO will be operating mainly in scanning (discovery) mode with a field-of-view of 2.5 sr (Special Relativity) (20 percent of the sky observation any time), with the capability to be pointed to particular regions of interest..

Moiseev, Alexander↗

Response functions of Fuji imaging plates to monoenergetic protons in the energy range 0.6-3.2 MeV

We have measured the responses of Fuji MS, SR, and TR imaging plates (IPs) to protons with energies ranging from 0.6 to 3.2 MeV. Monoenergetic protons were produced with the 3.5 MV AIFIRA (Applications Interdisciplinaires de Faisceaux d'Ions en Region Aquitaine) accelerator at the Centre d'Etudes Nucleaires de Bordeaux Gradignan (CENBG). The IPs were irradiated with protons backscattered off a tantalum target. We present the photo-stimulated luminescence response of the IPs together with the fading measurements for these IPs. A method is applied to allow correction of fading effects for variable proton irradiation duration. Using the IP fading corrections, a model of the IP response function to protons was developed. The model enables extrapolation of the IP response to protons up to proton energies of 10 MeV. Our work is finally compared to previous works conducted on Fuji TR IP response to protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HEAO 3 observations of strong variable 0.5-3 MeV emission from the Taurus region

Preliminary results are reported of observations of strong (greater than 10 sigma) variable MeV emission from the Taurus region, possibly the Crab nebula, in 1980 by the HEAO 3 Gamma-Ray Spectroscopy experiment. The about 50-day time-averaged spectrum of the Crab shows a new component, which consists of a hard spectral 'knee' in the 0.4-1 MeV range, followed by a higher energy component extending to greater than 3 MeV, superposed on the canonical Crab power law spectrum with a spectral index of 2.2. This new spectral component was not observed four months earlier in the fall of 1979, when the spectrum was consistent with a single power law with the index of 2.2, the same as that observed in 1980. There is no indication that the gamma-ray emission was pulsed.

Ling, James C.↗

Direct dark matter searches with metal halide perovskites

Polar materials with optical phonons in the meV range are excellent candidates for both dark matter direct detection via dark photon-mediated scattering and light dark matter absorption. In this study, we propose, for the first time, the metal halide perovskites MAPbI 3 , MAPbCl 3 , and CsPbI 3 for these purposes. Our findings reveal that CsPbI 3 is the best material, significantly improving exclusion limits compared to other polar materials. For scattering, CsPbI 3 can probe dark matter masses down to the keV range. For absorption, it enhances sensitivity to detect dark photon masses below ∼10 meV. The only material that has so far been investigated and that could provide competitive bounds is CsI, which, however, demonstrates lower stability as device platform compared to CsPbI 3 . Moreover, CsI is isotropic while the anisotropic structure of CsPbI 3 enables daily modulation analysis, showing that a significant percentage of daily modulation exceeding 1% is achievable for dark matter masses below 40 keV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Jovian electron spectrum and synchrotron radiation at 375 cm

The synchrotron radiation expected at Earth from the region L=2.9-5 R sub J of Jupiter's magnetosphere is calculated using the Pioneer 10 electron model. The result is approximately 21 flux units (f.u.). This value is to be compared with 6.0 + or - 0.7 f.u., the flux density of synchrotron radiation measured from Jupiter's entire magnetosphere in ground-based radio observations. Most of the radiation at 375 cm is emitted by electrons in the 1 to 10 MeV range. If the electron model used for calculations is cut off below 10 MeV, the calculated flux is reduced to approximately 4 f.u., a level compatible with the radio observations.

Birmingham, T. J.↗

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste - 16648

Measures required to assure long term safe storage of Low-level and intermediate-level short-lived (LIL/SL) waste generated by the nuclear-power industry in France include the characterization of the waste and identification of materials within the waste. Digital Radiography (DR) techniques using x-ray at energies in the 6 MeV range have been shown to be effective for validation of the integrity of the concrete containers, and it was considered that the use of this technique together with the addition of Computed Tomography (CT) techniques could effectively identify materials within the waste. This paper describes the initial evaluation of two DR imaging techniques and two CT techniques using x-ray energy spectra up to 9 MeV to inspect a surrogate waste package, which comprised an outer concrete cylindrical container of 1400 mm diameter with 148 mm wall thickness, and an overall volume of 2 meters cubed, within which a 200 liter drum containing representative heterogeneous inactive waste, was placed in the center and the annulus between the 200 liter drum and the outer cylindrical package was filled with cement grout. The surrogate waste within the 200 liter drum comprised three separate layers of high density, medium density and low density mixed materials. The equipment used was a linear accelerator producing high energy spectra at either 6 MeV or 9 MeV and a high-precision CT manipulator with X, Y, Z and rotation motions, which were common to all techniques investigated. Two different digital detectors were used in the DR and CT performance evaluations, a Digital Detector Array (DDA) comprising a columnar Thallium-doped Cesium-Iodide scintillator screen in intimate contact with a 2 k by 2 k array of amorphous silicon detectors, 200 μm x 200 μm in area, and a Linear Diode Array (LDA) comprising a line of Cadmium-Tungstate columns, 1 cm thick and 400 μm x 400 μm in area. The work comprised evaluations of linear accelerator spectra and the attenuation effects of the waste container and contents, image acquisition performance of each detector, and CT techniques using area detector and linear detector. The results presented in this paper include mathematical evaluation of the two CT techniques, and analysis of measurement data, digital images, CT reconstruction images, and estimated material densities. The data was compared with recorded details and photographs of the actual configuration of materials within the surrogate waste. The Digital Detector Array can generate CT inspection volumes with considerable resolution and detail for the low-density and medium-density sections of the surrogate waste, however, the high-density sections were not imaged with sufficient detail and the images contained a large number of artifacts mainly due to the detectors lack of high energy photon stopping power. Materials identification with the Digital Detector Array, while possible for certain materials, for materials in the steel to plastic density range the attenuation values of the voxels in the reconstruction are too similar and difficult to resolve from the artifacts present. The Linear Diode Array can generate CT inspection volumes of regions of interest of the low-density and medium-density sections with considerable resolution and contrast, and potentially acceptable levels of resolution and contrast of the high-density section of the waste. While a few artifacts were present in the reconstructions, the majority are not due to the fundamental properties of the detector and are considered to be correctable. Materials identification with the LDA inspection data appear to be viable, with steel, copper, and higher-density metals being readily be distinguished from other materials on the basis of voxel value. Future work is needed to obtain a better definition of optimum spatial resolution and inspection speed, and to develop a system of 'calibration rods' which would consist of a series of 50 mm diameter cylinders of 7 materials; Plastic, Teflon, Concrete, Aluminum, Copper, Tungsten and Lead. The cylinders will be distributed at a certain radius in the surrogate waste and will be used as reference points in the evaluation and demonstration of the contrastive performance for the low, medium and high-density cases. The ability to identify the materials within a sealed waste container, by nondestructive examination, enables the verification of waste acceptance criteria without the need to open the waste containers. This eliminates the need for complex and expensive equipment to open and remotely handle the intermediate level waste, avoids potential hazards and risk of personnel dose uptake, and does not increase the volume of waste caused by repackaging of materials after examination and the decontamination or disposal of equipment used.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overview of fast particle experiments in the first MAST Upgrade experimental campaigns

Abstract MAST-U is equipped with on-axis and off-axis neutral beam injectors (NBI), and these external sources of super-Alfvénic deuterium fast-ions provide opportunities for studying a wide range of phenomena relevant to the physics of alpha-particles in burning plasmas. The MeV range D-D fusion product ions are also produced but are not confined. Simulations with the ASCOT code show that up to 20% of fast ions produced by NBI can be lost due to charge exchange (CX) with edge neutrals. Dedicated experiments employing low field side (LFS) gas fuelling show a significant drop in the measured neutron fluxes resulting from beam-plasma reactions, providing additional evidence of CX-induced fast-ion losses, similar to the ASCOT findings. Clear evidence of fast-ion redistribution and loss due to sawteeth (ST), fishbones (FB), long-lived modes (LLM), Toroidal Alfvén Eigenmodes (TAE), Edge Localised Modes (ELM) and neoclassical tearing modes (NTM) has been found in measurements with a Neutron Camera (NCU), a scintillator-based Fast-Ion Loss Detector (FILD), a Solid-State Neutral Particle Analyser (SSNPA) and a Fast-Ion Deuterium- α (FIDA) spectrometer. Unprecedented FILD measurements in the range of 1–2 MHz indicate that fast-ion losses can be also induced by the beam ion cyclotron resonance interaction with compressional or global Alfvén eigenmodes (CAEs or GAEs). These results show the wide variety of scenarios and the unique conditions in which fast ions can be studied in MAST-U, under conditions that are relevant for future devices like STEP or ITER.

Physics↗

The Effect of 1–10-MeV Neutrons on the JESD89 Test Standard

Here, the JESD89 test standard defines how terrestrial neutron testing is conducted [1] . The test standard covers a number of different types of radiation used for testing, including protons, neutrons, and alphas, and different types of testing, including life testing and accelerated testing. Broad-spectrum neutron testing is the most common type of accelerated radiation testing for the terrestrial radiation environment. Unlike most test standards, the JESD89 defines the minimum energy for determining the cumulative fluence for the deployed and test environment. Currently, the minimum energy is set at 10 MeV. As the test standard is currently being rewritten, changing the minimum energy to 1 MeV is being explored, because it is believed that the onset to neutron-induced single-event effects (SEEs) is less than 10 MeV. There are three separate problems with lowering the minimum energy: determining whether electronics have a sensitivity to neutron-induced SEEs below 10 MeV, determining whether the test spectra match the terrestrial environment in the 1–10-MeV range, and the measurement error caused by not including the fluence from 1 to 10 MeV. In this paper, we present information on these factors and whether the minimum energy should be lowered to 1 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the total photoabsorption cross section on a proton in the energy range 600-1500 MeV at the GRAAL

The total photoabsorption cross section on a free proton was measured at the GRAAL facility in the energy range E{sub {gamma}} = 600-1500 MeV. The large-aperture LAGRAN{gamma}E detector and a liquid hydrogen target were used in the experiment performed with a back-scattered Compton gamma beam. To improve the accuracy, two alternative methods were employed. First, a subtraction method of using empty-target measurements allowed the cross section {sigma}{sub tot} to be evaluated directly because of a low level of the electromagnetic background. Second, an algorithm for evaluating {sigma}{sub tot} on the basis of summing the dominating partial cross sections was developed. Experimental results obtained for {sigma}{sub tot} by the two methods are compared with existing data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SONTRAC: A solar neutron track chamber detector

The recent detection on the solar maximum mission (SMM) satellite of high energy neutrons emitted during large solar flares has provided renewed incentive to design a neutron detector which has the sensitivity, energy resolution, and time resolution to measure the neutron time and energy spectra with sufficient precision to improve our understanding of the basic flare processes. Over the past two decades a variety of neutron detectors has been flown to measure the atmospheric neutron intensity above 10 MeV and to search for solar neutrons. The SONTRAC (Solar Neutron Track Chamber) detector, a new type of neutron detector which utilizes n-p scattering and has a sensitivity 1-3 orders of magnitude greater than previous instruments in the 20-200 MeV range is described. The energy resolution is 1% for neutron kinetic energy, T sub n 50 MeV. When used with a coded aperture mask at 50 m (as would be possible on the space station) an angular resolution of approx. 4 arc sec could be achieved, thereby locating the sites of high energy nuclear interactions with an angular precision comparable to the existing x-ray experiments on SMM. The scintillation chamber is investigated as a track chamber for high energy physics, either by using arrays of scintillating optical fibers or by optical imaging of particle trajectories in a block of scintillator.

Frye, G. M., Jr.↗

Discovery of ions with nuclear charge Z greater than or equal to 9 stability trapped in the earth's radiation belts

Observations of MeV heavy ions obtained by Explorer 45 in an equatorial earth orbit during a 7 month period in 1972 are presented, including data from four major magnetic storms. The spacecraft contained a heavy ion detector telescope and heavy ion discriminator electronics. Heavy ions were distinguished from protons and electrons, and He ions and ions heavier than F were recorded on separate data channels. The L equals 2.25 to L equals 4 zones were probed, and it was found that the relative enhancement in heavy ion fluxes in the radiation belts over the prestorm ion flux intensities tends to increase with increasing ion mass and/or increasing ion energy in the MeV range. The radial profiles of ions with nucleon number greater than nine peak at L equals 2.9, and MeV ions in this class decay on time scales from 23 days at L equals 3.25 to 55 days at L equals 2.25. Indirect evidence indicated a solar source for the very heavy ions in the magnetosphere.

Spjeldvik, W. N.↗

Analysis of data on proton-proton scattering in the energy range 100-1300 MeV

The results of a partial-wave analysis of data on proton-proton interaction in the energy range 100-1300 MeV are presented. The real parts of phase shifts were found for states of orbital angular momentum up to L = 9, while their imaginary parts were determined for states of orbital angular momentum up to L = 5. The sixth parameter of the S matrix was introduced in order to describe states of total angular momentum J = 2 and 4. The inelasticity thresholds were chosen individually for each state and were found to be substantially different from one another. The resulting solution was characterized by {chi}{sup 2} = 1.155 per point in the case where the number of experimental data was 12 841 and by a large imaginary part of the phase shift in the {sup 3}P{sub 2}-wave state at the edge of the energy range. Special features of the interaction in orbital states are discussed along with the energy dependence of integrated amplitudes and amplitudes of the scattering matrix at zero angle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characteristics of bursts observed by the SMM Gamma-Ray Spectrometer

The Gamma Ray Spectrometer (GRS) on the SMM completed close to 10 years of highly successful operation when the spacecraft reentered the atmosphere on December 2, 1989. During this period the GRS detected 177 events above 300 keV which have been classified as cosmic gamma-ray bursts. A catalog of these events is in preparation which will include time profiles and spectra for all events. Visual inspection of the spectra indicates that emission typically extends into the MeV range, without any evidence for a high-energy cutoff; 17 of these events are also observed above 10 MeV. We find no convincing evidence for line-like emission features in any of the time-integrated spectra.

Share, G. H.↗

Gamma-ray observations of Cygnus X-1 and Cygnus X-3 using a coded-aperture telescope

A balloon-borne coded-aperture telescope, measuring gamma-ray photons in the 160 keV to 9.3 MeV range, was used to observe the Cygnus region of the sky on October 1 and 2, 1984. In the 2-9.3-MeV band, evidence is found for a hard spectral component with a mean flux level at the top of the atmosphere of 7.4 + or - 2.5 x 10 to the -7th photons/sq cm per s per keV, inconsistent with the predictions of the inverse Compton models normally used to describe the X-ray emission. Both Cyg X-1 and Cyg X-3 could be observed simultaneously with the telescope. The results are used to establish 1-sigma upper flux limits on the spectral emission from Cyg X-3.

Mcconnell, M. L.↗

Probability Estimates of Solar Particle Event Doses During a Period of Low Sunspot Number for Thinly-Shielded Spacecraft and Short Duration Missions

In an earlier paper (Atwell, et al., 2015), we investigated solar particle event (SPE) radiation exposures (absorbed dose) to small, thinly-shielded spacecraft during a period when the sunspot number (SSN) was less than 30. These SPEs contain Ground Level Events (GLE), sub-GLEs, and sub-sub-GLEs (Tylka and Dietrich, 2009, Tylka and Dietrich, 2008, and Atwell, et al., 2008). GLEs are extremely energetic solar particle events having proton energies extending into the several GeV range and producing secondary particles in the atmosphere, mostly neutrons, observed with ground station neutron monitors. Sub-GLE events are less energetic, extending into the several hundred MeV range, but do not produce secondary atmospheric particles. Sub-sub GLEs are even less energetic with an observable increase in protons at energies greater than 30 MeV, but no observable proton flux above 300 MeV. In this paper, we consider those SPEs that occurred during 1973-2010 when the SSN was greater than 30 but less than 50. In addition, we provide probability estimates of absorbed dose based on mission duration with a 95% confidence level (CL). We also discuss the implications of these data and provide some recommendations that may be useful to spacecraft designers of these smaller spacecraft.

Atwell, William↗

Sub-GLE Solar Particle Events and the Implications for Lightly-Shielded Systems Flown During an Era of Low Solar Activity

Many of the large space missions must be very rigorous in their designs to reduce risk from radiation damage as much as possible. Some ways of reducing this risk have been to build in multiple redundancies, purchase/develop radiation hardened electronics parts, and plan for worst case radiation environment scenarios. These methods work well for these ambitious missions that can afford the costs associated with these meticulous efforts. However, there have been more small spacecraft and CubeSats with smaller duration missions entering the space arena, which can take some additional risks, but cannot afford to implement all of these risk-reducing methods. Therefore, one way to quantify the radiation exposure risk for these smaller spacecraft would be to investigate the radiation environment pertinent to the mission to better understand these radiation exposures, rather than always designing to the infrequent, worst-case environment. In this study, we have investigated 34 historical solar particle events (1974-2010) that occurred during a time period when the sun spot number (SSN) was less than 30. These events contain Ground Level Events (GLE), sub-GLEs, and sub-sub-GLEs(sup 1-3). GLEs are extremely energetic solar particle events (SPEs) having proton energies often extending into the several GeV range and producing secondary particles in the atmosphere, mostly neutrons, observed with ground station neutron monitors. Sub-GLE events are less energetic, extending into the several hundred MeV range, but without producing detectable levels of secondary atmospheric particles. Sub-sub GLEs are even less energetic with an observable increase in protons at energies greater than 30 MeV, but no observable proton flux above 300 MeV. The spectra for these events were fitted using a double power law fit in particle rigidity, called the Band fit method. The differential spectra were then input into the NASA Langley Research Center HZETRN 2005, which is a high-energy particle transport/dose code, to determine the dose in various thicknesses of aluminum, representing the spacecraft. This paper will detail the absorbed dose results of each of these environments, as well as analyze the data to better understand the doses over small thicknesses that are more relevant to small spacecraft and satellites, such as CubeSats. In addition, we will discuss the implications of these data and provide some recommendations that may be useful to spacecraft designers of these smaller spacecraft/CubeSat-type missions.

Atwell, William↗

Neutron fluences and dose equivalents measured with passive detectors on LDEF

Neutron fluences were measured on LDEF in the low energy (< 1 MeV) and high energy (> 1 MeV) ranges. The low energy detectors used the 6Li(n,alpha)T reaction with Gd foil absorbers to separate thermal (< 0.2 eV) and resonance (0.2 eV-1 MeV) neutron response. High energy detectors contained sets of fission foils (181Ta, 209Bi, 232Th, 238U) with different neutron energy thresholds. The measured neutron fluences together with predicted spectral shapes were used to estimate neutron dose equivalents. The detectors were located in the A0015 and P0006 experiments at the west and Earth sides of LDEF under shielding varying from 1 to 19 g/cm2. Dose equivalent rates varied from 0.8 to 3.3 microSv/d for the low energy neutrons and from 160 to 390 microSv/d for the high energy neutrons. This compares with TLD measured absorbed dose rates in the range of 1000-3000 microGy/d near these locations and demonstrates that high energy neutrons contribute a significant fraction of the total dose equivalent in LEO. Comparisons between measurements and calculations were made for high energy neutrons based on fission fragment tracks generated by fission foils at different shielding depths. A simple 1-D slab geometry was used in the calculations. Agreement between measurements and calculations depended on both shielding depth and threshold energy of the fission foils. Differences increased as both shielding and threshold energy increased. The modeled proton/neutron spectra appeared deficient at high energies. A 3-D model of the experiments is needed to help resolve the differences.

LDEF Project↗