Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEASUREMENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

MEASUREMENT OF GALAXY CLUSTER INTEGRATED COMPTONIZATION AND MASS SCALING RELATIONS WITH THE SOUTH POLE TELESCOPE

We describe a method for measuring the integrated Comptonization (Y {sub SZ}) of clusters of galaxies from measurements of the Sunyaev-Zel'dovich (SZ) effect in multiple frequency bands and use this method to characterize a sample of galaxy clusters detected in the South Pole Telescope (SPT) data. We use a Markov Chain Monte Carlo method to fit a β-model source profile and integrate Y {sub SZ} within an angular aperture on the sky. In simulated observations of an SPT-like survey that include cosmic microwave background anisotropy, point sources, and atmospheric and instrumental noise at typical SPT-SZ survey levels, we show that we can accurately recover β-model parameters for inputted clusters. We measure Y {sub SZ} for simulated semi-analytic clusters and find that Y {sub SZ} is most accurately determined in an angular aperture comparable to the SPT beam size. We demonstrate the utility of this method to measure Y {sub SZ} and to constrain mass scaling relations using X-ray mass estimates for a sample of 18 galaxy clusters from the SPT-SZ survey. Measuring Y {sub SZ} within a 0.'75 radius aperture, we find an intrinsic log-normal scatter of 21% ± 11% in Y {sub SZ} at a fixed mass. Measuring Y {sub SZ} within a 0.3 Mpc projected radius (equivalent to 0.'75 at the survey median redshift z = 0.6), we find a scatter of 26% ± 9%. Prior to this study, the SPT observable found to have the lowest scatter with mass was cluster detection significance. We demonstrate, from both simulations and SPT observed clusters that Y {sub SZ} measured within an aperture comparable to the SPT beam size is equivalent, in terms of scatter with cluster mass, to SPT cluster detection significance.

79 ASTRONOMY AND ASTROPHYSICS↗

Joint analysis of Dark Energy Survey Year 3 data and CMB lensing from SPT and P l a n c k . II. Cross-correlation measurements and cosmological constraints

Cross-correlations of galaxy positions and galaxy shears with maps of gravitational lensing of the cosmic microwave background (CMB) are sensitive to the distribution of large-scale structure in the Universe. Such cross-correlations are also expected to be immune to some of the systematic effects that complicate correlation measurements internal to galaxy surveys. We present measurements and modeling of the cross-correlations between galaxy positions and galaxy lensing measured in the first three years of data from the Dark Energy Survey with CMB lensing maps derived from a combination of data from the 2500 deg 2 SPT-SZ survey conducted with the South Pole Telescope and full-sky data from the Planck satellite. The CMB lensing maps used in this analysis have been constructed in a way that minimizes biases from the thermal Sunyaev Zel’dovich effect, making them well suited for cross-correlation studies. The total signal-to-noise of the cross-correlation measurements is 23.9 (25.7) when using a choice of angular scales optimized for a linear (nonlinear) galaxy bias model. Here we use the cross-correlation measurements to obtain constraints on cosmological parameters. For our fiducial galaxy sample, which consist of four bins of magnitude-selected galaxies, we find constraints of Ω m =0.272$^{+0.032}_{-0.052}$ and S 8 ≡σ8$\sqrt{Ω_m/0.3}$=0.736$^{+0.032}_{-0.028}$ (Ω m =0.245$^{+0.026}_{-0.044}$ and S 8 =0.734$^{+0.035}_{-0.028}$) when assuming linear (nonlinear) galaxy bias in our modeling. Considering only the cross-correlation of galaxy shear with CMB lensing, we find Ω m =0.270$^{+0.043}_{-0.061}$ and S 8 =0.740$^{+0.034}_{-0.029}$. Our constraints on S8 are consistent with recent cosmic shear measurements, but lower than the values preferred by primary CMB measurements from Planck.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom

Purpose: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Methods: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0–6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. Results: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4–6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0–4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. Conclusions: The authors demonstrate that relative dose distributions for VHEE beams of 50–70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

07 ISOTOPE AND RADIATION SOURCES↗

Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at $\sqrt{s}=7\mbox{~TeV}$ with the ATLAS detector

The inclusive and dijet production cross-sections have been measured for jets containing b-hadrons (b-jets) in proton–proton collisions at a centre-of-mass energy of s√=7~TeVs=7~TeV , using the ATLAS detector at the LHC. The measurements use data corresponding to an integrated luminosity of 34 pb -1 . The b-jets are identified using either a lifetime-based method, where secondary decay vertices of b-hadrons in jets are reconstructed using information from the tracking detectors, or a muon-based method where the presence of a muon is used to identify semileptonic decays of b-hadrons inside jets. The inclusive b-jet cross-section is measured as a function of transverse momentum in the range 20 T <400 GeV and rapidity in the range |y|<2.1. The $b\bar{b}$ -dijet cross-section is measured as a function of the dijet invariant mass in the range 110< m jj <760 GeV, the azimuthal angle difference between the two jets and the angular variable χ in two dijet mass regions. The results are compared with next-to-leading-order QCD predictions. Finally, good agreement is observed between the measured cross-sections and the predictions obtained using POWHEG + Pythia. MC@NLO + Herwig shows good agreement with the measured $b\bar{b}$-dijet cross-section. However, it does not reproduce the measured inclusive cross-section well, particularly for central b-jets with large transverse momenta.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Millennial model: in search of measurable pools and transformations for modeling soil carbon in the new century

Soil organic carbon (SOC) can be defined by measurable chemical and physical pools, such as mineral-associated carbon, carbon physically entrapped in aggregates, dissolved carbon, and fragments of plant detritus. Yet, most soil models use conceptual rather than measurable SOC pools. What would the traditional pool-based soil model look like if it were built today, reflecting the latest understanding of biological, chemical, and physical transformations in soils? We propose a conceptual model-the Millennial model-that defines pools as measurable entities. First, we discuss relevant pool definitions conceptually and in terms of the measurements that can be used to quantify pool size, formation, and destabilization. Then, we develop a numerical model following the Millennial model conceptual framework to evaluate against the Century model, a widely-used standard for estimating SOC stocks across space and through time. The Millennial model predicts qualitatively similar changes in total SOC in response to single factor perturbations when compared to Century, but different responses to multiple factor perturbations. We review important conceptual and behavioral differences between the Millennial and Century modeling approaches, and the field and lab measurements needed to constrain parameter values. We propose the Millennial model as a simple but comprehensive framework to model SOC pools and guide measurements for further model development.

decomposition↗

Comparing ecosystem and soil respiration: Review and key challenges of tower-based and soil measurements

The net ecosystem exchange (NEE) is the difference between ecosystem CO2 assimilation and CO2 losses to the atmosphere. Ecosystem respiration (Reco), the efflux of CO2 from the ecosystem to the atmosphere, includes the soil-to-atmosphere carbon flux (i.e., soil respiration; Rsoil) and aboveground plant respiration. Therefore, Rsoil is a fraction of Reco and by definition has to be smaller than Reco at annual, seasonal and daily scales. However, several studies estimating Reco with the eddy covariance technique and measuring Rsoil within the footprint of the tower have reported higher Rsoil than Reco at different time scales. Here, we compare four different and contrasting ecosystems (from forest to grasslands, and from boreal to semiarid) to study whether, and under what conditions, measurements of Reco are lower than Rsoil. In general, both fluxes showed similar temporal patterns, but Reco was not consistently higher than Rsoil from daily to annual scales across sites. We identified several issues that apply for measuring NEE and measuring/upscaling Rsoil that could result in an underestimation of Reco and/or an overestimation of Rsoil. These issues are discussed based on (a) nighttime measurements of NEE, (b) Rsoil measurements, and (c) the interpretation of the functional relationships of these fluxes with temperature (i.e., Q10). We highlight that there is still a need for better integration of Rsoil with eddy covariance measurements to address challenges related to spatial and temporal variability of Reco and Rsoil.

Barba, Josep↗

Rate equation model of laser induced bias in uranium isotope ratios measured by resonance ionization mass spectrometry

Resonance Ionization Mass Spectrometry (RIMS) has been developed as a method to measure uranium isotope abundances. In this approach, RIMS is used as an element-selective ionization process between uranium atoms and potential isobars without the aid of chemical purification and separation. The use of broad bandwidth lasers with automated feedback control of wavelength was applied to the measurement of the U-235/U-238 ratio to decrease laser-induced isotopic fractionation. In application, isotope standards are used to identify and correct bias in measured isotope ratios, but understanding laser-induced bias from first-principles can improve the precision and accuracy of experimental measurements. A rate equation model for predicting the relative ionization probability has been developed to study the effect of variations in laser parameters on the measured isotope ratio. The model uses atomic data and empirical descriptions of laser performance to estimate the laser-induced bias expected in experimental measurements of the U-235/U-238 ratio. Empirical corrections are also included to account for ionization processes that are difficult to calculate from first principles with the available atomic data. Development of this model has highlighted several important considerations for properly interpreting experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Poloidally and radially resolved parallel D{sup +} velocity measurements in the DIII-D boundary and comparison to neoclassical computations

First measurements of the D{sup +} parallel velocity, V{sub ||}{sup D+}, in L-mode discharges in the DIII-D [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] tokamak boundary region at two poloidal locations, {theta}{approx}0 deg. and {theta}{approx}255 deg., made using Mach probes, feature a peak with velocities of up to 80 km/s at the midplane last closed flux surface (LCFS), as high as ten times the charge exchange recombination C{sup 6+} toroidal velocity, V{sub {phi}}{sup C6+}, in the same location. The V{sub ||}{sup D+} profiles are very asymmetric poloidally, by a factor of 8-10, and feature a local peak at the midplane. This peak, 1-2 cm wide, is located at or just inside the LCFS, and it suggests a large source of momentum in that location. This momentum source is quantified at {approx}0.31 N m by using a simple momentum transport model. This is the most accurate measurement of the effects of so called 'intrinsic' edge momentum source to date. The V{sub ||}{sup D+} measurements are quantitatively consistent with a purely neoclassical computational modeling of V{sub ||}{sup D+} by the code NEO[E. A. Belli and J. Candy, Plasma Phys. Controlled Fusion 50, 095010 (2008)], using V{sub {phi}}{sup C6+} as input, for {rho}{approx}0.7-0.95 at the two poloidal locations, where V{sub ||}{sup D+} measurements exist. The midplane NEO-calculated V{sub ||}{sup D+} grows larger than V{sub ||}{sup C6+} in the steeper edge gradient region and trends to agreement with the probe-measured V{sub ||}{sup D+} data near {rho}{approx}1, where the local V{sub ||}{sup D+} velocity peak exists. The measurements and computations were made in OH and L-mode discharges on an upper single null, with ion {nabla}B{sub T} drift away from the divertor. The rotating layer finding is similar in auxiliary heated discharges with and without external momentum input, except that at higher density the edge velocity weakens.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On specular reflectivity measurements in high and low-contrast relativistic laser-plasma interactions

Using both experiment and 2D3V particle-in-cell (PIC) simulations, we describe the use of specular reflectivity measurements to study relativistic (Iλ{sup 2 }> 10{sup 18 }W/cm{sup 2}⋅μm{sup 2}) laser-plasma interactions for both high and low-contrast 527 nm laser pulses on initially solid density aluminum targets. In the context of hot-electron generation, studies typically rely on diagnostics which, more-often-than-not, represent indirect processes driven by fast electrons transiting through solid density materials. Specular reflectivity measurements, however, can provide a direct measure of the interaction that is highly sensitive to how the EM fields and plasma profiles, critical input parameters for modeling of hot-electron generation, evolve near the interaction region. While the fields of interest occur near the relativistic critical electron density, experimental reflectivity measurements are obtained centimeters away from the interaction region, well after diffraction has fully manifested itself. Using a combination of PIC simulations with experimentally inspired conditions and an analytic, non-paraxial, pulse propagation algorithm, we calculate reflected pulse properties, both near and far from the interaction region, and compare with specular reflectivity measurements. The experiment results and PIC simulations demonstrate that specular reflectivity measurements are an extremely sensitive qualitative, and partially quantitative, indicator of initial laser/target conditions, ionization effects, and other details of intense laser-matter interactions. The techniques described can provide strong constraints on many systems of importance in ultra-intense laser interactions with matter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the Inclusive $t\bar{t}$ Production Cross Section in $p\bar{p}$ Collisions at $\sqrt{s}=1.96$ TeV and Determination of the Top Quark Pole Mass

The inclusive cross section of top quark-antiquark pairs produced in pp¯ collisions at s=1.96 TeV is measured in the lepton+jets and dilepton decay channels. The data sample corresponds to 9.7 fb-1 of integrated luminosity recorded with the D0 detector during Run II of the Fermilab Tevatron Collider. Employing multivariate analysis techniques we measure the cross section in the two decay channels and we perform a combined cross section measurement. For a top quark mass of 172.5 GeV, we measure a combined inclusive top quark-antiquark pair production cross section of σtt¯=7.26±0.13(stat)-0.50+0.57(syst) pb which is consistent with standard model predictions. We also perform a likelihood fit to the measured and predicted top quark mass dependence of the inclusive cross section, which yields a measurement of the pole mass of the top quark. The extracted value is mt=172.8±1.1(theo)-3.1+3.3(exp) GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Airborne Sunphotometer Measurements of Aerosol Optical Depth and Columnar Water Vapor During the Puerto Rico Dust Experiment, and Comparison with Land, Aircraft, and Satellite Measurements

Analyses of aerosol optical depth (AOD) and columnar water vapor (CWV) measurements obtained with the six-channel NASA Ames Airborne Tracking Sunphotometer (AATS-6) mounted on a twin-engine aircraft during the summer 2000 Puerto Rico Dust Experiment are presented. In general, aerosol extinction values calculated from AATS-6 AOD measurements acquired during aircraft profiles up to 5 km ASL reproduce the vertical structure measured by coincident aircraft in-situ measurements of total aerosol number and surface area concentration. Calculations show that the spectral dependence of AOD was small (mean Angstrom wavelength exponents of approximately 0.20) within three atmospheric layers defined as the total column beneath the top of each aircraft profile, the region beneath the trade wind inversion, and the region within the Saharan Air Layer (SAL) above the trade inversion. This spectral behavior is consistent with attenuation of incoming solar radiation by large dust particles or by dust plus sea salt. Values of CWV calculated from profile measurements by AATS-6 at 941.9 nm and from aircraft in-situ measurements by a chilled mirror dewpoint hygrometer agree to within approximately 4% (0.13 g/sq cm). AATS-6 AOD values measured on the ground at Roosevelt Roads Naval Air Station and during low altitude aircraft runs over the adjacent Cabras Island aerosol/radiation ground site agree to within 0.004 to 0.030 with coincident data obtained with an AERONET Sun/sky Cimel radiometer located at Cabras Island. For the same observation times, AERONET retrievals of CWV exceed AATS-6 values by a mean of 0.74 g/sq cm (approximately 21 %) for the 2.9-3.9 g/sq cm measured by AATS-6. Comparison of AATS-6 aerosol extinction values obtained during four aircraft ascents over Cabras Island with corresponding values calculated from coincident aerosol backscatter measurements by a ground-based micro-pulse lidar (MPL-Net) located at Cabras yields a similar vertical structure above the trade inversion. Finally, AATS-6 AOD values measured during low altitude aircraft traverses over the ocean are compared with corresponding AOD values retrieved over water from upwelling radiance measurements by the MODIS, TOMS, and GOES-8 Imager satellite sensors, with mixed results. These exercises highlight the need for continued satellite sensor comparison/validation studies to improve satellite AOD retrieval algorithms, and the usefulness of airborne sunphotometer measurements in the validation process.

Livingston, John M.↗

Isolation Standard Measures: A Set of Validated and Feasible Measurements Ensuring Comparability Across Isolation and Confinement Studies

Isolation and confinement studies have been essential to the preparation of crewed long-duration space missions, acting as analogues that facilitate the study of psychological and physiological responses to isolation and confinement. They also serve as opportunities for the development, testing, and validation of countermeasures and coping methods to handle the challenges that arise in such scenarios. Due to the small sample sizes in combination with high inter-individual variability, single isolation campaigns are not always sufficient for obtaining statistically significant scientific findings. To address this issue and improve comparability between different studies, the need for standardized measures to be collected in all future isolation and confinement studies was identified. Additionally, these measures should also be shown to be generally valid, reliable, feasible and acceptable in analogue and spaceflight environments. Standard measures in isolation and confinement studies allow for more direct comparisons of results and synthesis of data across isolation and confinement studies as well as provide an important step toward standard measures in spaceflight. An international expert group with representatives from different space agencies worldwide was brought together to define a core set of standard measures for isolation and confinement studies. This paper provides an overview of the expert group’s recommendations for international standard measures for future isolation and confinement studies, along with subsequent updates coordinated by the International Countermeasures Working Group (ICMWG), which was established as a sub-Working Group under the International Space Life Sciences Working Group (ISLSWG). Additional experts were consulted by the ICMWG partner agencies as required. The collection of the described set of isolation standard measures will provide data on the following parameters: sleep, mood, psychological state, psychophysiology, cognitive performance, stress and the immune system, general health and well-being, team measures, nutritional measures, and environmental conditions. For each measure, recommendations were made about duration and frequency of administration, along with specific implementation recommendations in relation to the duration of the isolation study. The set of isolation standard measures will be reassessed every two years at a minimum to ensure they are up to date and reflect the current state-of-the-art.

Isolation↗

Double Chooz {theta}13 measurement via total neutron capture detection

Neutrinos were assumed to be massless particles until the discovery of the neutrino oscillation process. This phenomenon indicates that the neutrinos have non-zero masses and the mass eigenstates (nu(1), nu(2), nu(3)) are mixtures of their flavour eigenstates (nu(e), nu(mu), nu(tau)). The oscillations between different flavour eigenstates are described by three mixing angles (theta(12), theta(23), theta(13)), two differences of the squared neutrino masses of the nu(2)/nu(1) and nu(3)/nu(1) pairs and a charge conjugation parity symmetry violating phase delta(CP). The Double Chooz experiment, located near the Chooz Electricite de France reactors, measures the oscillation parameter theta(13) using reactor neutrinos. Here, the Double Chooz collaboration reports the measurement of the mixing angle theta(13) with the new total neutron capture detection technique from the full data set, yielding sin(2)(2 theta(13)) = 0.105 +/- 0.014. This measurement exploits the multidetector configuration, the isoflux baseline and data recorded when the reactors were switched off. In addition to the neutrino mixing angle measurement, Double Chooz provides a precise measurement of the reactor neutrino flux, given by the mean cross-section per fission <sigma(f)& rang; = (5.71 +/- 0.06) x 10(-43) cm(2) per fission, and reports an empirical model of the distortion in the reactor neutrino spectrum. The Double Chooz collaboration reports the neutrino oscillation parameter theta(13) from a measurement of the disappearance of reactor anti-electron neutrinos with the total neutron capture technique.

Djurcic, Z.↗

The Retrocausal Nature of Quantum Measurement Revealed by Partial and Weak Measurements

Quantum measurement is sometimes more effective when its result is not definite. Partial measurement turns the initial superposition not into a certain state but to a greater probability for it, enabling probing the quantum state in cases where complete measurement makes the noncommuting variables inaccessible. It also enables full quantum erasure that, unlike prevailing method, can be carried out even on recorded results. Aharonov's weak measurement is another method of imprecisely measuring quantum variables, outsmarting the uncertainty principle in even subtler ways. Happily, the two methods complement and corroborate one another in several interesting ways. We gedankenly apply these measurements to the EPR case. A pair of entangled particles undergoes more than one pair of partial and weak measurements, which, unlike complete measurements, leave them partially correlated. Their erasure is then shown to be as nonlocal as measurement itself. Surprisingly, the temporal relations between such measurements in the EPR setting do not follow the temporal sequence perceived by an external observer. For each particle, the measurements performed on the other operate as if they occurred (with signs reversed) in its own past, and in reversed order. This fully accords with Cramer's transactional interpretation and Aharonov's two state-vector formalism.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma response measurements of non-axisymmetric magnetic perturbations on DIII-D via soft x-ray imaging

Recent observations on DIII-D have advanced the understanding of plasma response to applied resonant magnetic perturbations (RMPs) in both H-mode and L-mode plasmas. Three distinct 3D features localized in minor radius are imaged via filtered soft x-ray emission: (i) the formation of lobes extending from the unperturbed separatrix in the X-point region at the plasma boundary, (ii) helical kink-like perturbations in the steep-gradient region inside the separatrix, and (iii) amplified islands in the core of a low-rotation L-mode plasma. In this study, these measurements are used to test and to validate plasma response models, which are crucial for providing predictive capability of edge-localized mode control. In particular, vacuum and two-fluid resistive magnetohydrodynamic(MHD) responses are tested in the regions of these measurements. At the plasma boundary in H-mode discharges with n = 3 RMPs applied, measurements compare well to vacuum-field calculations that predict lobe structures. Yet in the steep-gradient region, measurements agree better with calculations from the linear resistive two-fluid MHD code, M3D-C1. Relative to the vacuum fields, the resistive two-fluid MHD calculations show a reduction in the pitch-resonant components of the normal magnetic field (screening), and amplification of non-resonant components associated with ideal kink modes. However, the calculations still over-predict the amplitude of the measuredperturbation by a factor of 4. In a slowly rotating L-mode plasma with n = 1 RMPs, core islands are observed amplified from vacuum predictions. Finally, these results indicate that while the vacuum approach describes measurements in the edge region well, it is important to include effects of extended MHD in the pedestal and deeper in the plasma core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Local Resistance Measurement for Degradation of c-Si Heterojunction with Intrinsic Thin Layer (HIT) Solar Modules

Silicon heterojunction with intrinsic thin layer (or HIT) modules typically degrade at a rate of less than 1% annually in solar fields with dominant degradation in open-circuit voltage and some degradation in series resistance. However, detailed mechanisms can differ from module to module. Here, we study increases in local series resistance that occur over long-term field deployment, indicated by cell areas where the photoluminescence intensity does not degrade but the electroluminescence degrades significantly. To directly measure the local series resistance, we have cored out the local electroluminescence-degraded area, and we measured the sheet resistance by 4-point-probe and local nm-scale resistance using scanning spreading resistance microscopy (SSRM). The results by 4-point-probe show scattered sheet resistance that can be caused, for example, by nonuniform current paths through the transparent conductive oxide layer, the a-Si:H emitter, or the near-junction c-Si inversion layer. In contrast, the SSRM results indicate a relatively uniform and non-degraded resistivity on smaller nanometer spatial scales. SSRM is an atomic force microscopy-based two-terminal resistance mapping technique that measures the local resistance in nm-volume beneath the probe. The consistent resistances measured on the control and degraded samples can exclude the degradation of transparent conductive oxide resistance.

41 EE - Solar Energy Technologies Office (EE-4S)↗

WE-A-BRE-01: Debate: To Measure or Not to Measure

Recent studies have highlighted some of the limitations of patient-specific pre-treatment IMRT QA measurements with respect to assessing plan deliverability. Pre-treatment QA measurements are frequently performed with detectors in phantoms that do not involve any patient heterogeneities or with an EPID without a phantom. Other techniques have been developed where measurement results are used to recalculate the patient-specific dose volume histograms. Measurements continue to play a fundamental role in understanding the initial and continued performance of treatment planning and delivery systems. Less attention has been focused on the role of computational techniques in a QA program such as calculation with independent dose calculation algorithms or recalculation of the delivery with machine log files or EPID measurements. This session will explore the role of pre-treatment measurements compared to other methods such as computational and transit dosimetry techniques. Efficiency and practicality of the two approaches will also be presented and debated. The speakers will present a history of IMRT quality assurance and debate each other regarding which types of techniques are needed today and for future quality assurance. Examples will be shared of situations where overall quality needed to be assessed with calculation techniques in addition to measurements. Elements where measurements continue to be crucial such as for a thorough end-to-end test involving measurement will be discussed. Operational details that can reduce the gamma tool effectiveness and accuracy for patient-specific pre-treatment IMRT/VMAT QA will be described. Finally, a vision for the future of IMRT and VMAT plan QA will be discussed from a safety perspective. Learning Objectives: Understand the advantages and limitations of measurement and calculation approaches for pre-treatment measurements for IMRT and VMAT planning Learn about the elements of a balanced quality assurance program involving modulated techniques Learn how to use tools and techniques such as an end-to-end test to enhance your IMRT and VMAT QA program.

60 APPLIED LIFE SCIENCES↗

Measurement of Sauter mean diameter in diesel sprays using a scattering–absorption measurement ratio technique

A new diagnostic for the quantification of Sauter mean diameter in high-pressure fuel sprays has been recently developed using combined optical and X-ray measurements at the Georgia Institute of Technology and Argonne National Laboratory, respectively. This diagnostic utilizes liquid scattering extinction measurements from diffuse back-illumination imaging, conducted at Georgia Tech, and liquid absorption measurements from X-ray radiography, conducted at Argonne’s Advanced Photon Source. The new diagnostic, entitled the scattering–absorption measurement ratio, quantifies two-dimensional distributions of path-integrated Sauter mean diameter, enabling the construction of the spatial history of drop size development within practical fuel sprays. This technique offers unique benefits over conventional drop-sizing methods in that it can be more robust in optically dense regions of the spray, while also providing high spatial resolution of the corresponding droplet field. The methodology for quantification of Sauter mean diameter distributions using the scattering–absorption measurement ratio technique has been previously introduced and demonstrated in diesel sprays using the Engine Combustion Network Spray D injector; however, a more detailed treatment of measurement uncertainties has been needed. In this work, we present a summary of the various sources of measurement uncertainty in the scattering–absorption measurement ratio diagnostic, like those due to the experimental setup, data processing methods, and theoretical assumptions, and assess how these sources of uncertainty affect the quantified Sauter mean diameter. The spatially resolved Sauter mean diameter measurements that result from the scattering–absorption measurement ratio diagnostic will be especially valuable to the engine modeling community for the quantitative validation of spray submodels in engine computational fluid dynamics codes. Careful evaluation and quantification of measurement uncertainties are important to support accurate model validation and to ensure the development of more predictive spray models.

42 ENGINEERING↗