Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

H2O masers in star-forming regions

A comprehensive model is presented for the powerful H2O masers observed in star-forming regions. The shocks are the result of interaction of dense, high-velocity clumps with dense shells or clumps in the ambient medium. The shocked material is a thin slab in physical space, but breaks up into a network of filaments in velocity space. These filaments are the individual H2O maser features. The results of maser model calculations are presented which provide the maximum brightness temperatures that can be produced in single-temperature environments of any kind.

Elitzur, Moshe↗

Propagation and absorption of electron-cyclotron maser radiation during solar flares

The propagation and absorption of the maser radiation during solar flares are examined through linear theory and electromagnetic particle simulations. It is shown using linear theory that strong absorption of the radiation should occur as it propagates toward the second harmonic layer, where the magnetic field is half as strong as in the emission region. Only radiation propagating nearly parallel to the magnetic field in a low-temperature plasma may be able to escape under certain limited conditions. Finite temperature effects can cause radiation propagating nearly perpendicular to the magnetic field to refract, causing enhanced absorption. Particle simulations are then used to evaluate the nonlinear response of the plasma as the maser radiation propagates through the absorption layer. It is shown that some of the maser radiation is able to escape through a process of absorption below the second harmonic of the local gyrofrequency and re-emission above it. The fraction able to escape is much higher than that predicted by linear theory, although the amount of escaping energy is only a small fraction of the incident energy.

Mckean, M. E.↗

Modifications to the relationship between the magnetic field and weak Zeeman features in the spectra of astrophysical masers

Numerical solutions are presented for the equations of radiative transfer for astrophysical masers in a magnetic field to describe the observed weak circular polarization of H2O and SiO masers. Previously unrecognized intensity-dependent effects are found to produce circular polarization which resembles that of the usual Zeeman effect. Astrophysical H2O, SiO, and perhaps other masers are likely to be radiatively saturated with rates for stimulated emission that are within 1-2 orders of magnitude of the Zeeman frequency. Under these conditions, the circular polarization found here tends to be larger (but can be smaller) and may be of opposite sign from that given by the standard treatment for polarized Zeeman spectra.

Nedoluha, Gerald E.↗

Hydrogen masers with cavity frequency switching servos

The stability of the free-running hydrogen maser is limited by pulling of the unperturbed hydrogen transition frequency due to instability of the cavity resonance frequency. While automatic spin-exchange tuning is in principle the more basic and accurate method, the required beam intensity switching and the long servo time constant result in reduced stability for measuring intervals up to 10(exp 6) seconds. More importantly, the spin-exchange tuning method requires a second stable frequency source as a reference, ideally a second hydrogen maser, to get the best results. The cavity frequency switching servo, on the other hand, has very little effect on the maser short term stability, and is fast enough to correct for cavity drift while maintaining the cavity at the spin-exchange tuned offset required to minimize instability due to beam intensity fluctuations. Not only does the cavity frequency switching servo not require a second stable frequency source, but the frequency reference is the atomic hydrogen radiated beam signal, so that no extra RF connections need be made to the cavity, and externally generated signals that would perturb the hydrogen atom need not be transmitted through the cavity. The operation of the cavity frequency switching stabilization method is discussed and the transient response of the servo and certain other aspects of the technique that have potential for achieving improved basic accuracy are illustrated.

Peters, Harry E.↗

Physics of systematic frequency variations in hydrogen masers

The frequency stability of hydrogen masers for intervals longer that 10(exp 4) seconds is limited at present by systematic processes. Researchers discuss the physics of frequency-determining mechanisms internal to the maser that are susceptible to systematic variations, and the connections between these internal mechanisms and external environmental factors. Based upon estimates of the magnitudes of systematic effects, they find that the primary internal mechanisms currently limiting long-term maser frequency stability are cavity pulling, at the level parts in 10(exp 15) per day, and wall shift variations, at the level of parts in 10(exp 16) to parts in 10(exp 15) per day. They discuss strategies for reducing systematic frequency variations.

Mattison, Edward M.↗

In orbit demonstration of a H-maser clock system

The ESA/NASA technology demonstration flight of a pair of hydrogen masers on the EURECA 3 mission is planned for 1998. The ESA part of the experiment will have a maser built by Neuchatel Observatory and a microwave time and frequency transfer system derived from the existing Precise Range and Range Rate Equipment (PRARE) system. The NASA part of the experiment will have a maser built by the Smithsonian Astrophysical Observatory and a laser time transfer system. The technology demonstration experiment is described with its expected outcomes and applications.

Busca, Giovanni↗

Physics of systematic frequency variations in hydrogen masers

The frequency stability of hydrogen masers for intervals longer than 10 exp 4 s is currently limited by systematic processes. The physics of frequency-determining mechanisms internal to the maser that are susceptible to systematic variations, and the connections between these internal mechanisms and external environmental factors are discussed. From estimates of the magnitudes of systematic effects, it is found that the primary internal mechanisms limiting long-term maser frequency stability are cavity pulling, at the level of parts in 1015 per day, and wall shift variations, at the level of parts in 10 exp 16 to parts in 10 exp 15 per day. Strategies for reducing systematic frequency variations are discussed.

Mattison, Edward M.↗

Water masers in W49N - The youngest stellar jet?

Observations by Gwinn et al. (1992) of the proper motions of water masers in W49N show that they have an elongated distribution expanding from a common center. Features with high space velocity only occur far from the center, while low-velocity features occur at all distances. It is proposed that water masers in star-forming regions occur in expanding shells swept up by high-velocity winds from young, massive stars during the early phases of the expansion. In W49N, confinement of the bubble by a density distribution with an axial cavity can explain both the velocity field and the shape of the maser distribution. A fully dynamical calculation of the expanding bubble is presented which provides a satisfactory fit for the observations and suggests that this system is only about 250 yr old. Thus these observations may show the very first stages of the formation of a jet from a young stellar object.

Mac Low, MORDECAI-M.↗

Temperature-Control Apparatus For Hydrogen Maser

Thermal-control apparatus maintains hydrogen maser at nearly constant temperature during long-term operational test. Designed to maintain, in small cylindrical vacuum tank containing maser, nearly isothermal condition when test conducted in air. Provides approximation of more nearly isothermal condition expected to be maintained in intended application, in which maser operated in vacuum environment and losses of heat reduced further by multilayer reflective insulation.

Vessot, R. F. C.↗

Providing hydrogen maser timing stability to orbiting VLBI radio telescope observations by post-measurement compensation of linked frequency standard imperfections

Orbiting VLBI (OVLBI) astronomical observations are based upon measurements acquired simultaneously from ground-based and earth-orbiting radio telescopes. By the mid-1990s, two orbiting VLBI observatories, Russia's Radioastron and Japan's VSOP, will augment the worldwide VLBI network, providing baselines to earth radio telescopes as large as 80,000 km. The challenge for OVLBI is to effectuate space to ground radio telescope data cross-correlation (the observation) to a level of integrity currently achieved between ground radio telescopes. VLBI radio telescopes require ultrastable frequency and timing references in order that long term observations may be made without serious cross-correlation loss due to frequency source drift and phase noise. For this reason, such instruments make use of hydrogen maser frequency standards. Unfortunately, space-qualified hydrogen maser oscillators are currently not available for use on OVLBI satellites. Thus, the necessary long-term stability needed by the orbiting radio telescope may only be obtained by microwave uplinking a ground-based hydrogen maser derived frequency to the satellite. Although the idea of uplinking the frequency standard intrinsically seems simple, there are many 'contaminations' which degrade both the long and short term stability of the transmitted reference. Factors which corrupt frequency and timing accuracy include additive radio and electronic circuit thermal noise, slow or systematic phase migration due to changes of electronic circuit temporal operating conditions (especially temperature), ionosphere and troposphere induced scintillations, residual Doppler-incited components, and microwave signal multipath propagation. What is important, though, is to realize that ultimate stability does not have to be achieved in real-time. Instead, information needed to produce a high degree of coherence in the subsequent cross-correlation operation may be derived from a two-way coherent radio link, recorded and later introduced as compensations adjunct to the VLBI correlation process. Accordingly, this paper examines the technique for stable frequency/time transfer within the OVLBI system, together with a critique of the types of link degradation components which must be compensated, and the figures of merit known as coherence factors.

Springett, James C.↗

High Precision Time Transfer in Space with a Hydrogen Maser on MIR

An atomic hydrogen maser clock system designed for long term operation in space will be installed on the Russian space station Mir, in late 1997. The H-maser's frequency stability will be measured using pulsed laser time transfer techniques. Daily time comparisons made with a precision of better than 100 picoseconds will allow an assessment of the long term stability of the space maser at a level on the order of 1 part in 10(sup 15) or better. Laser pulse arrival times at the spacecraft will be recorded with a resolution of 10 picoseconds relative to the space clock's time scale. Cube corner reflectors will reflect the pulses back to the Earth laser station to determine the propagation delay and enable comparison with the Earth-based time scale. Data for relativistic and gravitational frequency corrections will be obtained from a Global Positioning System (GPS) receiver.

Mattison, Edward M.↗

Dust Grains and the Luminosity of Circumnuclear Water Masers in Active Galaxies

In previous calculations for the luminosities of 22 GHz water masers, the pumping is reduced and ultimately quenched with increasing depth into the gas because of trapping of the infrared (approximately equals 30-150 micrometers), spectral line radiation of the water molecule. When the absorption (and reemission) of infrared radiation by dust grains is included, we demonstrate that the pumping is no longer quenched but remains constant with increasing optical depth. A temperature difference between the grains and the gas is required. Such conditions are expected to occur, for example, in the circumnuclear masing environments created by X-rays in active galaxies. Here, the calculated 22 GHz maser luminosities are increased by more than an order of magnitude. Application to the well-studied, circumnuclear masing disk in the galaxy NGC 4258 yields a maser luminosity near that inferred from observations if the observed X-ray flux is assumed to be incident onto only the inner surface of the disk.

Collison, Alan J.↗

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The room temperature hydrogen maser is an active atomic oscillator used as a high-frequency-stability local oscillator for radio astronomy, metrology, and spacecraft navigation, and in tests of fundamental physics. The cryogenic hydrogen maser (CHM) operates at 0.5 K, employing superfluid helium-coated walls to store the masing hydrogen atoms. We are investigating whether the CHM may provide better frequency stability than the room temperature hydrogen maser: one to three orders of magnitude improvement may be possible because of greatly reduced thermal noise and larger signal power. Exceptional frequency stability will be required for spacecraft tracking in future deep-space missions, for space-based tests of relativity and gravitation, and for local (i.e., flywheel) oscillators used with absolute frequency standards such as laser-cooled atomic fountains and linear ion traps. These new devices are passive high-resolution frequency discriminators. Alone, they cannot function as superior atomic clocks; their effective operation depends on being integrated with an active local oscillator with excellent short term stability - such as that possible with the CHM.

Walsworth, Ronald L.↗

X-Band Ultra-Low Noise Maser Amplifier Performance

Noise temperature measurements of an 8440 MHz ultra-low noise maser amplifier (ULNA) have been performed at sub-atmospheric, liquid helium temperatures. The traveling wave maser operated while immersed in a liquid helium bath. The lowest input noise temperature measured was 1.23 plus or minus 0.16 K at a physical temperature of 1.60 kelvin. At this physical temperature the observed gain per unit length of ruby was 4.6 dB/cm, and the amplifier had a 3 dB-bandwidth of 76 MHz.

ultra-low noise maser amplifier X-band maser syste↗

Parametric up-converter increases flexibility of maser

Parametric up-converter translates a broad band of signals to the fixed tuned input frequency of a maser. This modified maser can operate in the 1700-2300 Mc range, eliminating the need to duplicate equipment. It may be applied in communications and radio astronomy.

Summy, R. H.↗