Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MALE GENITALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

PSA Decrease During Combined-Modality Radiotherapy Predicts for Treatment Outcome

Purpose: Prostate-specific antigen (PSA) is the well-used marker in the diagnosis, prognosis, and follow-up for prostate cancer patients. Although reports have focused on the importance of pretreatment PSA levels, doubling time, and posttreatment nadirs, there is little information on the value of PSA during the course of radiotherapy. Methods and Materials: Retrospective review of PSA values obtained midway through a course of radiotherapy treatment for prostate cancer. Patients had a PSA (midPSA) measured after a course of external beam radiation (EBRT) before planned transperineal low-dose-rate brachytherapy implant (LDR). Results: A total of 717 patients were analyzed with a median follow-up of 5.8 years, all censored patients had a minimum follow-up of 2 years. A total of 277 patients had low-risk disease, 267 patients had intermediate risk, and 173 patients had high-risk disease. Androgen blockade was used in 512 patients. A total of 653 patients had a midPSA decrease after EBRT, the median decrease was 6.2 ng/mL. Patients who had a midPSA decrease {>=}25% compared with pretreatment PSA had improved overall survival of 10.0 vs. 7.4 years (p < 0.0004) and improved disease-free survival of 9.8 vs. 7.3 years (p < 0.01). When stratified by use of androgen blockade, midPSA remained significant for both androgen and non-androgen patients. Conclusions: PSA response after EBRT before brachytherapy predicts for long-term outcome; this may allow for risk stratification and intervention with higher LDR doses to improve outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Survivin Is a Potential Mediator of Prostate Cancer Metastasis

Purpose: We examined whether Survivin expression is associated with an increased risk of metastasis in prostate cancer. Methods and Materials: A total of 205 patients with T1 (23%) and T2 (77%) prostate cancer were treated with conventional external beam radiation therapy from 1991 to 1993 at the Massachusetts General Hospital. Of the patients, 62 had adequate and suitable-stained tumor material for Survivin analysis. Median follow-up was 102 months (range, 5-127 months). Distant failure was determined on the basis of clinical criteria. In preclinical studies, replication-deficient adenovirus encoding phosphorylation-defective Survivin Thr34{yields}Ala dominant-negative mutant pAd-S(T34A) or short hairpin RNA (shRNA) was used to inhibit Survivin in prostate cancer models, and the cell motility, morphology, and metastasis were investigated. Results: Our correlative data on men with early-stage (T1/T2) prostate cancers treated at Massachusetts General Hospital by definitive radiotherapy indicated that overexpression of Survivin (positive staining in {>=}10% cells) was associated with a significantly increased risk for the subsequent development of distant metastasis (p = 0.016) in the univariate analysis. In the multivariate analysis, overexpression of Survivin remained an independent predictor of distant metastasis (p = 0.008). The inhibition of Survivin dramatically inhibited invasiveness of prostate cancer cells in the in vitro invasion assay and spontaneous metastasis in the Dunning prostate cancer in vivo model. Furthermore, attenuation of Survivin resulted in changes in the microtubule cytoskeleton, loss of cellular polarity, and loss of motility. Conclusions: This study suggests that Survivin may be a potentially important prognostic marker and promising therapeutic target in metastatic prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rectal Dose-Volume Histogram Parameters Are Associated With Long-Term Patient-Reported Gastrointestinal Quality of Life After Conventional and High-Dose Radiation for Prostate Cancer: A Subgroup Analysis of a Randomized Trial

Purpose: We examined whether rectal dose-volume histogram (DVH) parameters were associated with long-term patient-reported gastrointestinal (GI) quality of life (QOL) after conventional (70.2 GyE) or high-dose (79.2 GyE) radiation for prostate cancer. Methods and Materials: Of 64 men with localized prostate cancer alive with a minimum 7-year follow-up after treatment as part of a randomized trial with either 70.2 GyE or 79.2 GyE of external beam radiation at Massachusetts General Hospital, 56 men (88%) returned a QOL questionnaire, and 50 of those men had DVH information. The DVH parameters of the anterior rectal wall were correlated with patient-reported long-term GI QOL using Pearson correlation and t tests. Results: There was a trend toward an association between increased long-term GI dysfunction and higher V60 (p = 0.07), V65 (p = 0.06), V70 (p = 0.09), and V75 (p = 0.09). When dichotomized by their medians, a V60 > 54% (p = 0.04), V70 > 44% (p = 0.06), and V75 > 39% (p = 0.06) were associated with increased long-term GI dysfunction. There was no difference in long-term GI dysfunction between men on the conventional vs. high-dose arms (p = 0.49). Conclusions: Dose-volume histogram parameters of the anterior rectal wall were associated with long-term patient-reported GI QOL after prostate radiation, whereas the dose prescribed to the prostate was not, suggesting that DVH constraints, rather than total prescribed dose, may have the greatest impact on long-term bowel dysfunction, and therefore that continued dose escalation may be feasible if appropriate dose-volume constraints are met.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate Intrafraction Motion Assessed by Simultaneous Kilovoltage Fluoroscopy at Megavoltage Delivery I: Clinical Observations and Pattern Analysis

Purpose: To describe prostate intrafraction motion using kilovoltage fluoroscopy at treatment delivery for a hypofractionated radiotherapy protocol. Methods and Materials: Kilovoltage images were acquired during treatment delivery, as well as pre- and posttreatment cone-beam computed tomography (CBCT) for each fraction of 30 patients, totaling 571 fractions for analysis. We calculated population statistics, evaluated correlation between interfraction and intrafraction motion, evaluated effect of treatment duration, classified whether motion resolved by posttreatment CBCT, and compared motion magnitude on a per-patient basis. Results: The elapsed time between pre- and post-CBCTs was (18.6 {+-} 4.5) min. The population mean of motion measured by kilovoltage fluoroscopy was (-0.1, 0.5, -0.6) mm, the systematic was (0.5, 1.3, 1.2) mm, and random was (0.9, 1.9, 2.0) mm in the right-left, anterior-posterior, and superior-inferior axes, respectively. The probability of motion increased with treatment duration, with the mean increasing to (0.0, 1.0, -0.9) mm and the systematic to (0.6, 1.7, 1.5) mm when measured using posttreatment CBCT. For any motion {>=}2mm, approximately 75% did not resolve by posttreatment CBCT. Motion magnitude varied considerably among patients, with the probability of a 5-mm displacement ranging from 0.0% to 58.8%. Conclusions: Time dependency of intrafraction motion should be considered to avoid bias in margin assessment, with posttreatment CBCT slightly exaggerating the true motion. The patient-specific nature of the intrafraction motion suggests that a patient-specific management approach may be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate-Specific Natural Health Products (Dietary Supplements) Radiosensitize Normal Prostate Cells

Purpose: Prostate-specific health products (dietary supplements) are taken by cancer patients to alleviate the symptoms linked with poor prostate health. However, the effect of these agents on evidence-based radiotherapy practice is poorly understood. The present study aimed to determine whether dietary supplements radiosensitized normal prostate or prostate cancer cell lines. Methods and Materials: Three well-known prostate-specific dietary supplements were purchased from commercial sources available to patients (Trinovin, Provelex, and Prostate Rx). The cells used in the study included normal prostate lines (RWPE-1 and PWR-1E), prostate tumor lines (PC3, DU145, and LNCaP), and a normal nonprostate line (HaCaT). Supplement toxicity was assessed using cell proliferation assays [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide] and cellular radiosensitivity using conventional clonogenic assays (0.5-4Gy). Cell cycle kinetics were assessed using the bromodeoxyuridine/propidium iodide pulse-labeling technique, apoptosis by scoring caspase-3 activation, and DNA repair by assessing gammaH2AX. Results: The cell growth and radiosensitivity of the malignant PC3, DU145, and LNcaP cells were not affected by any of the dietary prostate supplements (Provelex [2mug/mL], Trinovin [10mug/mL], and Prostate Rx [50 mug/mL]). However, both Trinovin (10mug/mL) and Prostate Rx (6mug/mL) inhibited the growth rate of the normal prostate cell lines. Prostate Rx increased cellular radiosensitivity of RWPE-1 cells through the inhibition of DNA repair. Conclusion: The use of prostate-specific dietary supplements should be discouraged during radiotherapy owing to the preferential radiosensitization of normal prostate cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of In-Room Computerized Tomography Options for Detection of Fiducial Markers in Prostate Cancer Radiotherapy

Purpose: To compare volumetric in-room computed tomography (CT) and kilovoltage (kV) cone-beam CT (CBCT) to planar imaging with respect to their ability to localize fiducial markers (FMs) for radiotherapy of prostate cancer. Methods and Materials: Image guidance options from two linear accelerators were compared in terms of identifying the center of gravity (COG) of FMs from the isocenter: a Siemens Primatom, where the couch is rotated 180 degrees from the treatment isocenter to the in-room CT vs. electronic portal imaging (EPI); and a Varian OBI system, where kV CBCT, EPI, and planar kV radiographs were compared. In all, 387 image pairs (CBCT = 133; CT = 254) from 18 patients were analyzed. A clinical tolerance of 3 mm was predefined as the acceptable threshold for agreement. Results: COG location on in-room CT and EPI was in agreement 96.9%, 85.8%, and 89.0% of the time in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions, respectively, vs. 99.2%, 91.7%, and 93.2% for the CBCT and EPI analysis. The CBCT vs. kV radiographs were in agreement 100% (LR), 85.4% (SI), and 88.5% (AP), and EPI vs. kV radiographs were in agreement 100% (LR), 94.6% (SI), and 91.5% (AP) of the time. Conclusion: Identification of FMs on volumetric or planar images was found to be not equivalent ({+-}3 mm) using either linear accelerator. Intrafraction prostate motion, interpretation of FM location, and spatial properties of images are contributing factors. Although in-room CT has superior image quality, the process of realigning the treatment couch to acquire a CT introduces an error, highlighting the benefits of a single isocentric system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Increasing Age and Treatment Modality Are Predictors for Subsequent Diagnosis of Bladder Cancer Following Prostate Cancer Diagnosis

Purpose: To determine the effect of prostate cancer therapy (surgery or external beam irradiation, or both or none) on the actuarial incidence of subsequent bladder cancer. Methods and Materials: The Surveillance, Epidemiology, and End Results registry from 1973 to 2005 was analyzed. Treatment was stratified as radiotherapy, surgery, both surgery and adjuvant radiation, and neither modality. Brachytherapy was excluded. Results: In all, 555,337 prostate carcinoma patients were identified; 124,141 patients were irradiated; 235,341 patients were treated surgically; 32,744 patients had both surgery and radiation; and 163,111 patients received neither modality. Bladder cancers were diagnosed in: 1,836 (1.48%) men who were irradiated (mean age, 69.4 years), 2,753 (1.09%) men who were treated surgically (mean age, 66.9 years); 683 (2.09%) men who received both modalities (mean age, 67.4 years), and 1,603 (0.98%) men who were treated with neither modality (mean age, 71.8 years). In each treatment cohort, Kaplan-Meier analyses showed that increasing age (by decade) was a significant predictor of developing bladder cancer (p < 0.0001). Incidence of bladder cancer was significantly different for either radiation or surgery alone versus no treatment, radiation versus surgery alone, and both surgery and radiation versus either modality alone (p < 0.0001). On multivariate analysis, age and irradiation were highly significant predictors of being diagnosed with bladder cancer. Conclusions: Following prostate cancer, increasing age and irradiation were highly significant predictors of being diagnosed with bladder cancer. While use of radiation increased the risk of bladder cancer compared to surgery alone or no treatment, the overall incidence of subsequent bladder cancer remained low. Routine bladder cancer surveillance is not warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stability, Visibility, and Histologic Analysis of a New Implanted Fiducial for Use as a Kilovoltage Radiographic or Radioactive Marker for Patient Positioning and Monitoring in Radiotherapy

Purpose: To analyze the stability, visibility, and histology of a novel implantable soft-tissue marker (nonradioactive and radioactive) implanted in dog prostate and rabbit liver. Methods and Materials: A total of 34 nonradioactive and 35 radioactive markers were implanted in 1 dog and 16 rabbits. Stability was assessed by measuring intermarker distance (IMD) variation relative to IMDs at implantation. The IMDs were measured weekly for 4 months in the dog and biweekly for 2-4 weeks in the rabbits. Ultrasound and X-ray imaging were performed on all subjects. Computed tomography and MRI were performed on the dog. Histologic analysis was performed on the rabbits after 2 or 4 months. Results: A total of 139 measurements had a mean ({+-} SD) absolute IMD variation of 1.1 {+-} 1.1 mm. These IMD variations are consistent with those reported in the literature as due to random organ deformation. The markers were visible, identifiable, and induced minimal or no image artifacts in all tested imaging modalities. Histologic analysis revealed that all pathologic changes were highly localized and not expected to be clinically significant. Conclusions: The markers were stable from the time of implantation. The markers were found to be compatible with all common medical imaging modalities. The markers caused no significant histologic effects. With respect to marker stability, visibility, and histologic analysis these implanted fiducials are appropriate for soft-tissue target positioning in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Study of Inguinal Hernia Repair Rates After Radical Prostatectomy or External Beam Radiotherapy

Purpose: We tested the hypothesis that patients treated for localized prostate cancer with radical prostatectomy (RP) have a higher risk of requiring an inguinal hernia (IH) repair than their counterparts treated with external beam radiotherapy (EBRT). Methods and Materials: Within the Quebec Health Plan database, we identified 6,422 men treated with RP and 4,685 men treated with EBRT for localized prostate cancer between 1990 and 2000, in addition to 6,933 control patients who underwent a prostate biopsy. From among that population, we identified patients who underwent a unilateral or bilateral hernia repair after either RP or EBRT. Kaplan-Meier plots showed IH repair-free survival rates. Univariable and multivariable Cox regression models tested the predictors of IH repair after RP or EBRT. Covariates consisted of age, year of surgery, and Charlson Comorbidity Index. Results: IH repair-free survival rates at 1, 2, 5, and 10 years were 96.8, 94.3, 90.5, and 86.2% vs. 98.9, 98.0, 95.4, and 92.2%, respectively, in RP vs. EBRT patients (log-rank test, p < 0.001). IH repair-free survival rates in the biopsy population were 98.3, 97.1, 94.9, and 90.2% at the same four time points. In multivariable Cox regression models, RP predisposed to a 2.3-fold higher risk of IH repair than EBRT (p < 0.001). Besides therapy type, patient age (p < 0.001) represented the only other independent predictor of IH repair. Conclusions: RP predisposes to a higher rate of IH repair relative to EBRT. This observation should be considered at informed consent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate Localization on Daily Cone-Beam Computed Tomography Images: Accuracy Assessment of Similarity Metrics

Purpose: To evaluate different similarity metrics (SM) using natural calcifications and observation-based measures to determine the most accurate prostate and seminal vesicle localization on daily cone-beam CT (CBCT) images. Methods and Materials: CBCT images of 29 patients were retrospectively analyzed; 14 patients with prostate calcifications (calcification data set) and 15 patients without calcifications (no-calcification data set). Three groups of test registrations were performed. Test 1: 70 CT/CBCT pairs from calcification dataset were registered using 17 SMs (6,580 registrations) and compared using the calcification mismatch error as an endpoint. Test 2: Using the four best SMs from Test 1, 75 CT/CBCT pairs in the no-calcification data set were registered (300 registrations). Accuracy of contour overlays was ranked visually. Test 3: For the best SM from Tests 1 and 2, accuracy was estimated using 356 CT/CBCT registrations. Additionally, target expansion margins were investigated for generating registration regions of interest. Results: Test 1-Incremental sign correlation (ISC), gradient correlation (GC), gradient difference (GD), and normalized cross correlation (NCC) showed the smallest errors ({mu} {+-} {sigma}: 1.6 {+-} 0.9 {approx} 2.9 {+-} 2.1 mm). Test 2-Two of the three reviewers ranked GC higher. Test 3-Using GC, 96% of registrations showed <3-mm error when calcifications were filtered. Errors were left/right: 0.1 {+-} 0.5mm, anterior/posterior: 0.8 {+-} 1.0mm, and superior/inferior: 0.5 {+-} 1.1 mm. The existence of calcifications increased the success rate to 97%. Expansion margins of 4-10 mm were equally successful. Conclusion: Gradient-based SMs were most accurate. Estimated error was found to be <3 mm (1.1 mm SD) in 96% of the registrations. Results suggest that the contour expansion margin should be no less than 4 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Baseline Serum Testosterone in Men Treated With Androgen Deprivation Therapy and Radiotherapy for Localized Prostate Cancer

Introduction: It is believed that men diagnosed with prostate cancer and a low baseline serum testosterone (BST) may have more aggressive disease, and it is frequently recommended they forgo testosterone replacement therapy. We used two large Phase III trials involving androgen deprivation therapy and external beam radiation therapy to assess the significance of a BST. Methods and Materials: All patients with a BST and complete data (n = 2,478) were included in this analysis and divided into four categories: 'Very Low BST' (VLBST) {<=}16.5th percentile of BST ({<=}248 ng/dL; n = 408); 'Low BST' (LBST) >16.5th percentile and {<=}33rd percentile (>248 ng/dL but {<=}314 ng/dL; n = 415); 'Average BST' (ABST) >33rd percentile and {<=}67th percentile (314-437 ng/dL; n = 845); and 'High BST' (HBST) >67th percentile (>437 ng/dL; n = 810). Outcomes included overall survival, distant metastasis, biochemical failure, and cause-specific survival. All outcomes were adjusted for the following covariates: treatment arm, BST, age (<70 vs. {>=}70), prostate-specific antigen (PSA; <10 vs. 10 {<=} PSA <20 vs. 20 {<=}), Gleason score (2-6 vs. 7 vs. 8-10); T stage (T1-T2 vs. T3-T4), and Karnofsky Performance Status (60-90 vs. 100). Results: On multivariable analysis age, Gleason score, and PSA were independently associated with an increased risk of biochemical failure, distant metastasis and a reduced cause-specific and overall survival (p < 0.05), but BST was not. Conclusions: BST does not affect outcomes in men treated with external beam radiation therapy and androgen deprivation therapy for prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate Intrafraction Motion Assessed by Simultaneous kV Fluoroscopy at MV Delivery II: Adaptive Strategies

Purpose: To investigate potential benefits of adaptive strategies for managing prostate intrafractional uncertainties when interfraction motion is corrected online. Methods and Materials: Prostate intrafraction motion was measured using kV fluoroscopy during MV delivery for 571 fractions from 30 hypofractionated radiotherapy patients. We evaluated trending over treatment course using analysis of variance statistics, and we evaluated the ability to correct patient-specific systematic error and apply patient-specific statistical margins after 2 to 15 fractions to compensate 90% of motion. We also evaluated the ability to classify patients into small- and large-motion subgroups based on the first 2 to 20 fractions using discriminant analysis. Results: No time trend was observed over treatment course, and intrafraction motion was patient specific (p < 0.0001). Systematic error in the first week correlated well with that in subsequent weeks, with correlation coefficients of 0.53, 0.50, and 0.41 in right-left (RL), anterior-posterior (AP), and superior-inferior (SI), respectively. After 5 fractions, the adaptive strategy resulted in average margin reductions of 0.3, 0.7, and 0.7 mm in RL, AP, and SI, respectively, with margins ranging from 1 to 3.2 mm in RL, 2 to 7.0 mm in AP, and 2 to 6.6 mm in SI. By contrast, population margins to include the same percentage of motion were 1.7, 4.0, and 4.1 mm. After 2 and 5 fractions, patients were classified into small- and large-motion groups with {approx}77% and {approx}83% accuracy. Conclusions: Adaptive strategies are feasible and beneficial for intrafraction motion management in prostate cancer online image guidance. Patients may be classified into large- and small-motion groups in early fractions using discriminant analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Timing of Salvage Hormonal Therapy in Prostate Cancer Patients With Unfavorable Prognosis Treated With Radiotherapy: A Secondary Analysis of Radiation Therapy Oncology Group 85-31

Purpose: Radiation Therapy Oncology Group 85-31 was a randomized trial comparing radiotherapy (RT) alone vs. RT plus adjuvant androgen suppression for life in unfavorable-prognosis carcinoma of the prostate. We examined the impact of early initiation of salvage hormonal therapy (HT) in relapsing patients randomized to RT alone arm. Methods and Materials: Patients were divided into two groups: early salvage HT and late salvage HT. The early salvage group was defined as receiving HT with a prostate-specific antigen (PSA) level of less than 10 ng/mL, and the late salvage HT group had a PSA level of 10 ng/mL or greater. The outcomes were overall survival (OS), cause-specific mortality (CSM), and local failure (LF). The Kaplan-Meier estimation and log-rank test were used for OS, and the cumulative incidence estimation and Gray's test were used for CSM and LF. Proportional hazards regression models were used to compare the outcomes adjusted for other covariates. Results: The median follow-up times of surviving patients in the early and late salvage HT groups were about 11 and 13 years, respectively. The late salvage HT group had significantly more post-prostatectomy patients and patients with high Gleason scores. After adjustment for all covariates, OS was significantly longer in the early salvage HT group (hazard ratio, 1.5; p = 0.01). However, there were no statistically significant differences in LF or CSM between the groups. Conclusions: The early introduction of salvage HT resulted in improved OS but not improved CSM and LF. A randomized trial to define the optimal salvage hormonal timing is warranted in this group of patients with PSA recurrence after RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Confirmation of a Low {alpha}/{beta} Ratio for Prostate Cancer Treated by External Beam Radiation Therapy Alone Using a Post-Treatment Repeated-Measures Model for PSA Dynamics

Purpose: To estimate the {alpha}/{beta} ratio of prostate cancer treated with external beam radiation only by use of a model of long-term prostate-specific antigen (PSA) dynamics. Methods and Materials: Repeated measures of PSA from 5,093 patients from 6 institutions treated for localized prostate cancer by external beam radiation therapy (EBRT) without planned androgen deprivation were analyzed. A biphasic linear mixed model described the post-treatment evolution of PSA, rather than a conventional model of time to biochemical recurrence. The model was adjusted for standard prognostic factors (T stage, initial PSA level, and Gleason score) and cohort-specific effects. The radiation dose fractionation effect was estimated from the long-term rate of rise of PSA level. Results: Adjusted for other factors, total dose of EBRT and sum of squared doses per fraction were associated with long-term rate of change of PSA level (p = 0.0017 and p = 0.0003, respectively), an increase of each being associated with a lower rate of rise. The {alpha}/{beta} ratio was estimated at 1.55 Gy (95% confidence band, 0.46-4.52 Gy). This estimate was robust to adjustment of the linear mixed model. Conclusions: By analysis of a large EBRT-only cohort along with a method that uses all the repeated measures of PSA after the end of treatment, a low and precise {alpha}/{beta} was estimated. These data support the use of hypofractionation at fractional doses up to 2.8 Gy but cannot presently be assumed to accurately represent higher doses per fraction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Online Adaptive Replanning Method for Prostate Radiotherapy

Purpose: To report the application of an adaptive replanning technique for prostate cancer radiotherapy (RT), consisting of two steps: (1) segment aperture morphing (SAM), and (2) segment weight optimization (SWO), to account for interfraction variations. Methods and Materials: The new 'SAM+SWO' scheme was retroactively applied to the daily CT images acquired for 10 prostate cancer patients on a linear accelerator and CT-on-Rails combination during the course of RT. Doses generated by the SAM+SWO scheme based on the daily CT images were compared with doses generated after patient repositioning using the current planning target volume (PTV) margin (5 mm, 3 mm toward rectum) and a reduced margin (2 mm), along with full reoptimization scans based on the daily CT images to evaluate dosimetry benefits. Results: For all cases studied, the online replanning method provided significantly better target coverage when compared with repositioning with reduced PTV (13% increase in minimum prostate dose) and improved organ sparing when compared with repositioning with regular PTV (13% decrease in the generalized equivalent uniform dose of rectum). The time required to complete the online replanning process was 6 {+-} 2 minutes. Conclusion: The proposed online replanning method can be used to account for interfraction variations for prostate RT with a practically acceptable time frame (5-10 min) and with significant dosimetric benefits. On the basis of this study, the developed online replanning scheme is being implemented in the clinic for prostate RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate-Specific Antigen Bounce After Permanent Iodine-125 Prostate Brachytherapy-An Australian Analysis

Purpose: To report on prostate-specific antigen (PSA) 'bounces' after {sup 125}I prostate brachytherapy to review the relationship to biochemical control and correlate both clinical and dosimetric variables. Methods and Materials: We analyzed 194 hormone-naive patients with a follow-up of {>=}3 years. Four bounce definitions were applied: an increase of {>=}0.2 ng/mL (definition I), {>=}0.4 ng/mL (definition II), {>=}15% (definition III), and {>=}35% (definition IV) of a previous value with spontaneous return to the prebounce level or lower. Results: Using definition I, II, III, and IV, a bounce was detected in 50%, 34%, 11%, and 9% of patients, respectively. The median time to onset was 14-16 months, the duration was 12-21.5 months, and the magnitude of the increase was 0.5-2 ng/mL. A magnitude of >2 ng/mL, fulfilling the criteria for biochemical failure (BF) according to the American Society for Therapeutic Radiology and Oncology Phoenix definition, was detected in 11.3%, 16.9%, 47.6%, and 50% using definitions I, II, III, and IV, respectively; 11 patients (5.7%) had true BF. The PSA bounces occurred earlier than BF (p < 0.001). The prediction of BF remains controversial and is probably unrelated to biochemical control. The only statistically significant factor predictive of a PSA bounce was younger age (definitions I and II). Conclusion: PSA bounces are common after brachytherapy. All definitions resulted in a high number of false-positive calls for BF during the first 2 years. The definition of an increase of {>=}0.2 ng/mL should be preferred because of the lowest number of false-positive results for BF. Patients experiencing a PSA bounce during the first 2 years after brachytherapy should undergo surveillance every 3-6 months. Additional investigations are recommended for elevated postimplant PSA levels that have not corrected by 3 years of follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Prostate Bed Motion Using Daily Cone-Beam Computed Tomography During Postprostatectomy Radiotherapy

Purpose: To report on the interfraction total positioning error of the postoperative prostate bed and to quantify its components (bony misalignment [BM]and prostate bed motion [PBM]) using daily kilovoltage cone-beam computed tomography (CBCT). The role of an adaptive radiotherapy schedule (ART) was investigated. Methods and Materials: A total of 547 daily CBCT images from 15 consecutive patients who had been treated with prostate bed radiotherapy were retrospectively analyzed. The positioning error was measured by rigid co-registration of the daily CBCT with pretreatment CT planning scan. The total positioning error was quantified by co-registration of the CBCT with the CT planning scan to match the anterior rectal wall. Automatic bony pelvis co-registration was performed to separate BM and PBM. The ART was determined by the average total positioning error from the first 5 CBCT images. Results: The systematic error for the total positioning error in the left-right, superoinferior, and anteroposterior direction was 2.69, 2.00, and 2.65 mm with a random error of 1.99, 1.49, and 2.25 mm, resulting in a planning target volume margin of 8, 6, and 8 mm, respectively. ART reduced the margin by 54%, 44%, and 40%, respectively. Systematic errors in the left-right, superoinferior, and anteroposterior direction for BM was 2.66, 1.83, and 2.60 mm and for PBM was 0.44, 0.92, and 2.50 mm with a random error of 1.88, 1.24, and 1.77 mm for BM and 0.99, 1.38, and 2.32 mm for PBM, respectively. Conclusion: Without treatment verifications, 6-8-mm planning target volume margins are required because of PBM and BM. The anteroposterior PBM was significant. An ART protocol can reduce these planning target volume margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Escalation Improves Cancer-Related Events at 10 Years for Intermediate- and High-Risk Prostate Cancer Patients Treated With Hypofractionated High-Dose-Rate Boost and External Beam Radiotherapy

Purpose: To evaluate the 10-year outcomes of intermediate- and high-risk prostate cancer patients treated with a prospective dose escalation hypofractionated trial of pelvic external beam radiation therapy (P-EBRT) with a high-dose-rate (HDR) brachytherapy boost. Methods and Materials: From 1992 to 2007, 472 patients were treated with a HDR boost at William Beaumont Hospital. They had at least one of the following: a prostate-specific antigen (PSA) level of >10 ng/ml, a Gleason score of {>=}7, or clinical stage {>=}T2b. Patients received 46-Gy P-EBRT and an HDR boost. The HDR dose fractionation was divided into two dose levels. The prostate biologically equivalent dose (BED) low-dose-level group received <268 Gy, and the high-dose group received >268 Gy . Phoenix biochemical failure (BF) definition was used. Results: Median follow-up was 8.2 years (range, 0.4-17 years). The 10-year biochemical failure rate of 43.1% vs. 18.9%, (p < 0.001), the clinical failure rate of 23.4% vs. 7.7%, (p < 0.001), and the distant metastasis of 12.4% vs. 5.7%, (p = 0.028) were all significantly better for the high-dose level group. On Cox multivariate analysis, higher BED levels (p = 0.017; hazard ratio [HR]= 0.586), pretreatment PSA assays (p < 0.001, HR = 1.022), and Gleason scores (p = 0.004) were significant variables for reduced biochemical failure. Higher dose levels (p, 0.002; HR, 0.397) and Gleason scores (p < 0.001) were significant for clinical failure. Grade 3 genitourinary complications were 2% and 3%, respectively, and grade 3 gastrointestinal complication was <0.5%. Conclusions: This prospective trial using P-EBRT with HDR boost and hypofractionated dose escalation demonstrates a strong dose-response relationship for intermediate- and high-risk prostate cancer patients. The improvement at 10 years for locoregional control with higher radiation doses (BED, > 268Gy) has significantly decreased biochemical and clinical failures as well as distant metastasis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗