Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC SPECTROMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The ratio R{sub dp} of the quasielastic nd {yields} p(nn) to the elastic np {yields} pn charge-exchange-process yields at the proton emitting angle {theta}{sub p,lab} = 0 deg. over 0.55-2.0 GeV neutron beam energy region. Experimental results

New experimental results on ratio R{sub dp} of the quasielastic charge-exchange yield at the outgoing proton angle {theta}{sub p,lab} = 0 deg. for the nd {yields} p(nn) reaction to the elastic np {yields} pn charge-exchange yield, are presented. The measurements were carried out at the Nuclotron of the Veksler and Baldin Laboratory of High Energies of the JINR (Dubna) at the neutron-beam kinetic energies of 0.55, 0.8, 1.0, 1.2, 1.4, 1.8, and 2.0 GeV. The intense neutron beam with small momentum spread was produced by breakup of deuterons which were accelerated and extracted to the experimental hall. In both reactions mentioned above the outgoing protons with the momenta p{sub p} approximately equal to the neutron-beam momentum p{sub n,beam} were detected in the directions close to the direction of incident neutrons, i.e., in the vicinity of the scattering angle {theta}{sub p,lab} = 0 deg. Measured in the same data-taking runs, the angular distributions of the charge-exchange-reaction products were corrected for the well-known instrumental effects and averaged in the vicinity of the incident-neutron-beam direction. These corrected angular distributions for every of nd {yields} p(nn) and np {yields} pn charge-exchange processes were proportional to the differential cross sections of the corresponding reactions. The data were accumulated by Delta-Sigma setup magnetic spectrometer with two sets of multiwire proportional chambers located upstream and downstream of the momentum analyzing magnet. Inelastic processes were considerably reduced by the additional detectors surrounding the hydrogen and deuterium targets. The time-of-flight system was applied to identify the detected particles. The accumulated data treatment and analysis, as well as possible sources of the systematic errors are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Qweak - A Search For New Physics

Qweak is a currently running experiment at the Thomas Jefferson National Accelerator Lab in Newport News Virginia USA that will use parity-violating elastic electron-proton scattering to measure the weak charge of the proton (Q{sup P}{sub weak}). Longitudinally polarized electrons scatter off a liquid hydrogen target and pass through a toroidal-field magnetic spectrometer. In order to perform a 4% measurement of Q{sup P}{sub weak}, we will need to measure the momentum transfer (Q{sup 2}) to 0.5%. The Q{sup 2} will be measured using a tracking system consisting of two gas electron multipliers (GEM), four horizontal drift chambers (HDC), and four vertical drift chambers (VDC). I will outline the design of the full apparatus and discuss the details of the Q{sup 2} and Q{sup P}{sub weak} measurements that will be complete in 2012 with a brief update on the experiment's progress.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High precision measurement of the proton charge radius: The PRad experiment

The recent high precision measurements of the proton charge radius performed at PSI from muonic hydrogen Lamb shift puzzled the hadronic physics community. A value of 0.8418 ± 0.0007 fm was extracted which is 7σ smaller than the previous determinations obtained from electron-proton scattering experiments and based on precision spectroscopy of electronic hydrogen. An additional extraction of the proton charge radius from electron scattering at Mainz is also in good agreement with these 'electronic' determinations. An independent measurement of the proton charge radius from unpolarized elastic ep scattering using a magnetic spectrometer free method was proposed and fully approved at Jefferson Laboratory in June 2012. This novel technique uses the high precision calorimeter HyCal and a windowless hydrogen gas target which makes possible the extraction of the charge radius at very forward angles and thus very low momentum transfer Q{sup 2} up to 10{sup −4} (GeV/c){sup 2} with an unprecedented sub-percent precision for this type of experiment. In this paper, after a review of the recent progress on the proton charge radius extraction and the new high precision experiment PRad will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear structure analysis using the Orange Spectrometer

Recently, an Orange spectrometer, a focusing iron-free magnetic spectrometer, has been installed at a beam line of the 10 MV Tandem accelerator of the IKP of the University of Cologne. The high efficiency of 15% of 4{pi} for the detection of conversion electrons and the energy resolution of 1% makes the Orange spectrometer a powerful instrument. From the conversion electron spectrum, transition multipolarities can be determined using the so called K to L ratio. In combination with an array of germanium and lanthanum bromide detectors, e{sup -}-{gamma}-coincidences can be performed to investigate the level scheme. Moreover, the very fast lanthanum bromide scintillator with an energy resolution of 3% allows e{sup -}-{gamma} lifetime measurements down to 0.3 ns. A second Orange spectrometer can be added to build the Double Orange Spectrometer for e{sup -}-e{sup -}-coincidences. It is indispensable for lifetime measurements of low intensity or nearby lying transitions as often occur in odd-A and odd-odd nuclei. The capabilities are illustrated with several examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The design and performance of the electromagnetic calorimeters in Hall C at Jefferson Lab

The design and performance of the electromagnetic calorimeters in the magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers, construction information and comparisons of simulated and experimental results are presented. The design and simulated performance for a new calorimeter to be used in the new SHMS spectrometer is also presented. We have developed and constructed electromagnetic calorimeters from TF-1 type lead-glass blocks for the HMS and SOS magnetic spectrometers at JLab Hall C. The HMS/SOS calorimeters are of identical design and construction except for their total size. Blocks of dimension 10 cm × 10 cm × 70 cm are arranged in four planes and stacked 13 and 11 blocks high in the HMS and SOS respectively. The energy resolution of these calorimeters is better than 6%/√E, and pion/electron (π/e) separation of about 100:1 has been achieved in energy range 1–5 GeV. Good agreement has been observed between the experimental and GEANT4 simulated energy resolutions. The HMS/SOS calorimeters have been used nearly in all Hall C experiments, providing good energy resolution and a high pion suppression factor. No significant deterioration in their performance has been observed in the course of use since 1994. For the SHMS spectrometer, presently under construction, details on the calorimeter design and accompanying GEANT4 simulation efforts are given. A Preshower+Shower design was selected as the most cost-effective among several design choices. The preshower will consist of a layer of 28 modules with TF-1 type lead glass radiators, stacked in two columns. The shower part will consist of 224 modules with F-101 type lead glass radiators, stacked in a “fly's eye” configuration of 14 columns and 16 rows. The active area of 120 × 130 cm(2) will encompass the beam envelope at the calorimeter. The anticipated performance of the new calorimeter is simulated over the full momentum range of the SHMS, predicting resolution and yields similar to the HMS calorimeter. Good electron/hadron separation can be achieved by using energy deposition in the Preshower along with total energy deposition in the calorimeter. In this case the PID capability is similar to or better than that attainable with HMS calorimeter, with a pion suppression factor of a few hundreds predicted for 99% electron detection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Cosmic Ray Composition Experiment for Space Station (ACCESS)

In 1994 the first high-energy particle physics experiment for the Space Station, the Alpha Magnetic Spectrometer (AMS), was selected by NASA's Administrator as a joint collaboration with the U.S. Department of Energy (DOE). The AMS program was chartered to place a magnetic spectrometer in Earth orbit and search for cosmic antimatter. A natural consequence of this decision was that NASA would begin to explore cost-effective ways through which the design and implementation of AMS might benefit other promising payload experiments which were evolving from the Office of Space Science. The first such experiment to come forward was ACCESS in 1996. It was proposed as a new mission concept in space physics to place a cosmic-ray experiment of weight, volume, and geometry similar to the AMS on the ISS, and replace the latter as its successor when the AMS is returned to Earth. This was to be an extension of NASA's sub-orbital balloon program, with balloon payloads serving as the precursor flights and heritage for ACCESS. The balloon programs have always been a cost-effective NASA resource since the particle physics instrumentation for balloon and space applications are directly related. The next step was to expand the process, pooling together expertise from various NASA centers and universities while opening up definition of the ACCESS science goals to the international community through the standard practice of peer-review. This process is still on-going and the Accommodation Study presented here will discuss the baseline definition of ACCESS as we understand it today. Further detail on the history, scope, and background of the study is provided in Appendix A.

Wilson, Thomas L.↗

The MAGNEX large acceptance spectrometer

The main features of the MAGNEX large acceptance magnetic spectrometer are described. It has a quadrupole + dipole layout and a hybrid detector located at the focal plane. The aberrations due to the large angular (50 msr) and momentum (+- 13%) acceptance are reduced by an accurate hardware design and then compensated by an innovative software ray-reconstruction technique. The obtained resolution in energy, angle and mass are presented in the paper. MAGNEX has been used up to now for different experiments in nuclear physics and astrophysics confirming to be a multipurpose device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of the galactic cosmic ray and geomagnetic transmission models

A very high-momentum resolution particle spectrometer called the Alpha Magnetic Spectrometer (AMS) was flown in the payload bay of the Space Shuttle in a 51.65 degrees x 380-km orbit during the last solar minimum. This spectrometer has provided the first high statistics data set for galactic cosmic radiation protons, and helium, as well as limited spectral data on carbon and oxygen nuclei in the International Space Station orbit. First measurements of the albedo protons at this inclination were also made. Because of the high-momentum resolution and high statistics, the data can be separated as a function of magnetic latitude. A related investigation, the balloon borne experiment with a superconducting solenoid spectrometer (BESS), has been flown from Lynn Lake, Canada and has also provided excellent high-resolution data on protons and helium. These two data sets have been used here to study the validity of two galactic cosmic ray models and the geomagnetic transmission function developed from the 1990 geomagnetic reference field model. The predictions of both the CREME96 and NASA/JSC models are in good agreement with the AMS data. The shape of the AMS measured albedo proton spectrum, up to 2 GeV, is in excellent agreement with the previous balloon and satellite observations. A new LIS spectrum was developed that is consistent with both previous and new BESS 3He observations. Because the astronaut radiation exposures onboard ISS will be highest around the time of the solar minimum, these AMS measurements and these models provide important benchmarks for future radiation studies. AMS-02 slated for launch in September 2003, will provide even better momentum resolution and higher statistics data. Published by Elsevier Science Ltd.

unmanned↗

Measurements of fuel and ablator ρR in Symmetry-Capsule implosions with the Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility

The Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility (NIF) measures the neutron spectrum in the energy range of 4–20 MeV. This paper describes MRS measurements of DT-fuel and CH-ablator ρR in DT gas-filled symmetry-capsule implosions at the NIF. DT-fuel ρR's of 80–140 mg/cm{sup 2} and CH-ablator ρR's of 400–680 mg/cm{sup 2} are inferred from MRS data. The measurements were facilitated by an improved correction of neutron-induced background in the low-energy part of the MRS spectrum. This work demonstrates the accurate utilization of the complete MRS-measured neutron spectrum for diagnosing NIF DT implosions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pion electroproduction measurements in the nucleon resonance region

Here, we report new pion electroproduction measurements in the $\Delta (1232)$ resonance, utilizing the SHMS - HMS magnetic spectrometers of Hall C at Jefferson Lab. The data focus on a region that exhibits a strong and rapidly changing interplay of the mesonic cloud and quark-gluon dynamics in the nucleon. The results are in reasonable agreement with models that employ pion cloud effects and chiral effective field theory calculations, but at the same time they suggest that an improvement is required to the theoretical calculations and provide valuable input that will allow their refinements. The data illustrate the potential of the magnetic spectrometers setup in Hall C towards the study the $\Delta (1232)$ resonance. These first reported results will be followed by a series of measurements in Hall C, that will expand the studies of the $\Delta (1232)$ resonance offering a high precision insight within a wide kinematic range from low to high momentum transfers.

13.60.Fz Transition Form Factors↗

Composition measurements of the topside ionosphere using a magnetic mass spectrometer, ion mass spectrometer on ISIS-2 spacecraft

The ion mass spectrometer (IMS) on the ISIS-II satellite is described; it measures the composition and distribution of positive ions in the earth's ionosphere in the mass range of 1 to 64 atomic mass units. Significant data were received which show a wide variation in ion composition at night near the equator and in the daytime poleward of the plasmapause. It was found that these data enable further study of the polar wind and that the experiment produced timely data during the August, 1972 magnetic storm to show the development of a unique ionosphere above the plasmapause during the period of the storm. The scientific objectives and results of the experiment, the technical description of the instrument, a bibliography with sample papers attached, and a summary of recommendations for further study are presented.

Hoffman, J. H.↗

High-resolution measurements of the DT neutron spectrum using new CD foils in the Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility

The Magnetic Recoil neutron Spectrometer (MRS) on the National Ignition Facility measures the DT neutron spectrum from cryogenically layered inertial confinement fusion implosions. Yield, areal density, apparent ion temperature, and directional fluid flow are inferred from the MRS data. This paper describes recent advances in MRS measurements of the primary peak using new, thinner, reduced-area deuterated plastic (CD) conversion foils. The new foils allow operation of MRS at yields 2 orders of magnitude higher than previously possible, at a resolution down to ∼200 keV FWHM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Experiments with the Polarized Internal Gas Target (PIT) at ANKE/COSY

For future few-nucleon interaction studies with polarized beams and targets at COSY-Juelich, a polarized internal storage-cell gas target was implemented at the magnet spectrometer ANKE in summer 2005. First commissioning of the polarized Atomic Beam Source (ABS) at ANKE was carried out and some improvements of the system have been done. Storage-cell tests to determine the COSY beam dimensions have been performed. Electron cooling combined with stacking and stochastic cooling have been studied. Experiments with N{sub 2} gas in the storage cell to simulate the background produced by beam interaction with the aluminum cell walls were performed to investigate the beam heating by the target gas. The analysis of the d-vector p-vector {yields}dp and d-vector p-vector{yields}(dp{sub sp}){pi}{sup 0} reactions showed that events from the extended target can be clearly identified in the ANKE detector system.The polarization of the atomic beam of the ABS, positioned close to the strong dipole magnet D2 of ANKE, was tuned with a Lamb-shift polarimeter (LSP) beneath the target chamber. With use of the known analyzing powers of the quasi-free np{yields}d{pi}{sup 0} reaction, the polarization in the storage cell was measured to be Q{sub y} = 0.79{+-}0.07 in the vertical stray field of the D2 magnet acting as a holding field. The achieved target thickness was 2x10{sup 13} atoms/cm{sup 2} for one hyperfine state populated in the ABS beam only. With a COSY beam intensity of 6x10{sup 9} stored polarized deuterons in the ring, the luminosity for double polarized experiments was 1x10{sup 29} cm{sup -2} s{sup -1}.

43 PARTICLE ACCELERATORS↗

APES: Acute Precipitating Electron Spectrometer - A High Time Resolution Monodirectional Magnetic Deflection Electron Spectrometer

We present a description of the Acute Precipitating Electron Spectrometer (APES) that was designed and built for the Ground-to-Rocket Electron Electrodynamics Correlative Experiment (GREECE) auroral sounding rocket mission. The purpose was to measure the precipitating electron spectrum with high time resolution, on the order of milliseconds. The trade-off made in order to achieve high time resolution was to limit the aperture to only one look direction. The energy selection was done by using a permanent magnet to separate the incoming electrons, such that the different energies would fall onto different regions of the microchannel plate and therefore be detected by different anodes. A rectangular microchannel plate (MCP) was used (15 mm x 100 mm), and there was a total of 50 discrete anodes under the MCP, each one 15 mm x 1.5 mm, with a 0.5 mm spacing between anodes. The target energy range of APES was 200 eV to 30 keV.

Michell, R. G.↗

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters↗

Direct Reactions and Spectroscopy with Hydrogen Targets at the RIBF

The implementation of MINOS, a liquid-hydrogen target and vertex-tracking system, at the Radioactive Isotope Beam Factory (RIBF) of the RIKEN Nishina Center has led to numerous nuclear physics discoveries. In experiments involving rare-isotope beams at intermediate energies, MINOS was integrated with the DALI2 + γ-ray spectrometer and other auxiliary devices. These were positioned in front of both the ZeroDegree Spectrometer and the SAMURAI magnetic spectrometers for the identification of ejectiles following quasi-free scattering direct reactions. Notable outcomes include the first spectroscopy of unstable doubly magic nucleus, investigations into multi-neutron decays, and the study of shell evolution along isotopic chains. These studies have significantly advanced our understanding of nuclear structure, as well as the mechanism of direct reactions with fast beams. Simultaneously, these direct reactions enabled raising new physics questions and paved the way for next-generation experimental setups to address them. Through the combination of particle- and γ-spectroscopy with a broad range of nuclear reactions, new frontiers will be established in our understanding of nuclear structure and reaction mechanisms. Here, we review the past ten years of studies on direct reactions and spectroscopy of exotic nuclei with liquid-hydrogen targets at the RIBF and define a vision for the future.

Bertulani, Carlos A [East Texas A & M Univ., Comme↗

Reexamination of isoscalar giant resonances in 12 C and 93 Nb through 6 Li scattering

Inelastic Li 6 scattering at 100 MeV/u on C 12 and Nb 93 has been measured with the high-resolution magnetic spectrometer Grand Raiden. The magnetic-rigidity settings of the spectrometer covered excitation energies from 10 to 40 MeV and scattering angles in the range 0 ° < θ lab. < 2 ° . The isoscalar giant monopole resonance was selectively excited in the present data. Measurements free of instrumental background and the very favorable resonance-to-continuum ratio of Li 6 scattering allowed for precise determination of the E 0 strengths in C 12 and Nb 93 . Additionally, it was found that the monopole strength in C 12 exhausts 52 ± 3 (stat.) ± 8 (sys.) % of the energy-weighted sum rule (EWSR), which is considerably higher than results from previous α -scattering experiments. The monopole strength in Nb 93 exhausts 92 ± 4 (stat.) ± 10 (sys.) % of the EWSR, and it is consistent with measurements of nuclei with mass number of A ≈ 90 . Such comparison indicates that the isoscalar giant monopole resonance distributions in these nuclei are very similar, and no influence due to nuclear structure was observed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Astrogam - A magnetic rigidity spectrometer for gamma-ray astronomy

A novel concept is presented for a high-energy gamma-ray telescope with an extended energy range and excellent energy and angular resolution. The characteristics of Astrogam, a wide-field camera which makes an all-sky survey, are enumerated. Consideration is given to the instrument's unique features: wide energy range (four orders of magnitude and energy, which will bridge the gap between satellite and ground-based observations); excellent source location precision (multiple scattering error dominating nuclear recoil and measurement error below 20 GeV); and excellent energy resolution (1-percent energy resolution). Astrogam will make observations in the GTE energy range possible and could resolve complex source regions like the Crab pulsar/Nebular system, the Galactic center, and the Geminga region as well as discover the true nature of the sources.

Adams, James H., Jr.↗