Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Type-I superconductor pick-up coil in superconducting quantum interference device-based ultra-low field nuclear magnetic resonance

In ultra-low field nuclear magnetic resonance (ULF-NMR) with strong prepolarization field (B{sub p}), type-II superconducting pick-up coils may be vulnerable to flux pinning from the strong B{sub p}. Pick-up coils made of NbTi, Nb, and Pb were evaluated in terms of acquired NMR signal quality. The type-II pick-up coils showed degraded signals above 61 mT maximum exposure, while the Pb pick-up coil exhibited no such degradation. Furthermore, a negative counter pulse following a strong B{sub p} was shown to follow magnetic hysteresis loop to unpin the trapped flux in the type-II pick-up coil and restore the NMR signal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accelerated nanoscale magnetic resonance imaging through phase multiplexing

We report a method for accelerated nanoscale nuclear magnetic resonance imaging by detecting several signals in parallel. Our technique relies on phase multiplexing, where the signals from different nuclear spin ensembles are encoded in the phase of an ultrasensitive magnetic detector. We demonstrate this technique by simultaneously acquiring statistically polarized spin signals from two different nuclear species ({sup 1}H, {sup 19}F) and from up to six spatial locations in a nanowire test sample using a magnetic resonance force microscope. We obtain one-dimensional imaging resolution better than 5 nm, and subnanometer positional accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of anisotropic thermal transport on the resistive plasma response to resonant magnetic perturbation field

Plasma response to the resonant magnetic perturbation (RMP) field is numerically investigated by an extended toroidal fluid model, which includes anisotropic thermal transport physics parallel and perpendicular to the total magnetic field. The thermal transport is found to be effective in eliminating the toroidal average curvature induced plasma screening (the so called Glasser-Green-Johnson, GGJ screening) at slow toroidal flow regime, whilst having minor effect on modifying the conventional plasma screening regimes at faster flow. Furthermore, this physics effect of interaction between thermal transport and GGJ screening is attributed to the modification of the radial structure of the shielding current, resulted from the plasma response to the applied field. The modification of the plasma response (shielding current, response field, plasma displacement and the perturbed velocity) also has direct consequence on the toroidal torques produced by RMP. These modelling results show that thermal transport reduces the resonant electromagnetic torque as well as the torque associated with the Reynolds stress, but enhances the neoclassical toroidal viscous torque at slow plasma flow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A quantum description of radiation damping and the free induction signal in magnetic resonance

We apply the methods of cavity quantum electrodynamics (CQED), to obtain a microscopic and fully quantum-mechanical picture of radiation damping in magnetic resonance, and the nascent formation of the free induction signal. Numerical solution of the Tavis-Cummings model - i.e., multiple spins 1/2 coupled to a lossless single-mode cavity - shows in fine detail the transfer of Zeeman energy, via spin coherence, to excite the cavity - represented here by a quantized LC resonator. The case of a single spin is also solved analytically. Although the motion of the Bloch vector is non-classical, we nonetheless show that the quantum mechanical Rabi nutation frequency (as enhanced by cavity coupling and stimulated emission) gives realistic estimates of macroscopic signal strength and the radiation damping constant in nuclear magnetic resonance. We also show how to introduce dissipation: cavity losses by means of a master equation, and relaxation by the phenomenological method of Bloch. The failure to obtain the full Bloch equations (unless semi-classical conditions are imposed on the cavity) is discussed in light of similar issues arising in CQED (and in earlier work in magnetic resonance as well), as are certain problems relative to quantization of the electromagnetic near-field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring surface-area-to-volume ratios in soft porous materials using laser-polarized xenon interphase exchange nuclear magnetic resonance

We demonstrate a minimally invasive nuclear magnetic resonance (NMR) technique that enables determination of the surface-area-to-volume ratio (S/V) of soft porous materials from measurements of the diffusive exchange of laser-polarized 129Xe between gas in the pore space and 129Xe dissolved in the solid phase. We apply this NMR technique to porous polymer samples and find approximate agreement with destructive stereological measurements of S/V obtained with optical confocal microscopy. Potential applications of laser-polarized xenon interphase exchange NMR include measurements of in vivo lung function in humans and characterization of gas chromatography columns.

Non-NASA Center↗

Opportunities and Limitations of Nuclear Magnetic Resonance Spectroscopy in Astrobiology

For decades, Nuclear Magnetic Resonance (NMR) spectroscopy has been utilized as a powerful tool in various scientific disciplines, most prominently in chemistry, to determine molecular structures or monitor reactions. While well established in various fields, NMR applications in astrobiology are still unclear. This work aims to explore the potential of NMR in astrobiology, highlighting strengths but also weaknesses. We illustrate capabilities of NMR with two applications: (1) recently developed methods for position-specific carbon isotope analysis of complex organics; and (2) well-established tools for performing quantitative compositional analysis of complex organic mixtures. By utilizing samples relevant to astrobiology, specifically the amino acid valine and analogue mixtures of organics, we showcase that molecules retain a source dependent and distinct intramolecular carbon isotope fingerprint. We demonstrate that compositional sample analysis provides an independent and complementary line of evidence pointing towards the origin of a molecule or mixture. Together, these NMR tools have the potential to support life detection efforts, and aid in distinguishing between biotic and abiotic samples. Finally, we discuss sensitivity, detection limits, the portability of NMR, and propose how integration with mass-spectrometry techniques will be imperative to enable more targeted and comprehensive analyses relevant to astrobiology, including in-situ analysis but also sample return missions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lumbar spine disc height and curvature responses to an axial load generated by a compression device compatible with magnetic resonance imaging

STUDY DESIGN: Axial load-dependent changes in the lumbar spine of supine healthy volunteers were examined using a compression device compatible with magnetic resonance imaging. OBJECTIVE: To test two hypotheses: Axial loading of 50% body weight from shoulder to feet in supine posture 1) simulates the upright lumbar spine alignment and 2) decreases disc height significantly. SUMMARY OF BACKGROUND DATA: Axial compression on the lumbar spine has significantly narrowed the lumbar dural sac in patients with sciatica, neurogenic claudication or both. METHODS: Using a device compatible with magnetic resonance imaging, the lumbar spine of eight young volunteers, ages 22 to 36 years, was axially compressed with a force equivalent to 50% of body weight, approximating the normal load on the lumbar spine in upright posture. Sagittal lumbar magnetic resonance imaging was performed to measure intervertebral angle and disc height before and during compression. RESULTS: Each intervertebral angle before and during compression was as follows: T12-L1 (-0.8 degrees +/- 2.5 degrees and -1.5 degrees +/- 2.6 degrees ), L1-L2 (0.7 degrees +/- 1.4 degrees and 3.3 degrees +/- 2.9 degrees ), L2-L3 (4.7 degrees +/- 3.5 degrees and 7.3 degrees +/- 6 degrees ), L3-L4 (7.9 degrees +/- 2.4 degrees and 11.1 degrees +/- 4.6 degrees ), L4-L5 (14.3 degrees +/- 3.3 degrees and 14.9 degrees +/- 1.7 degrees ), L5-S1 (25.8 degrees +/- 5.2 degrees and 20.8 degrees +/- 6 degrees ), and L1-S1 (53.4 degrees +/- 11.9 degrees and 57.3 degrees +/- 16.7 degrees ). Negative values reflect kyphosis, and positive values reflect lordosis. A significant difference between values before and during compression was obtained at L3-L4 and L5-S1. There was a significant decrease in disc height only at L4-L5 during compression. CONCLUSIONS: The axial force of 50% body weight in supine posture simulates the upright lumbar spine morphologically. No change in intervertebral angle occurred at L4-L5. However, disc height at L4-L5 decreased significantly during compression.

Non-NASA Center↗

Exploring the Limits of Overhauser Dynamic Nuclear Polarization (O-DNP) for Portable Magnetic Resonance Detection of Low γ Nuclei

Nuclear magnetic resonance (NMR) spectroscopy in portable, permanent magnet-based spectrometers is primarily limited to nuclei with higher gyromagnetic ratio, γ, such as 1 H, 19 F, and 31 P due to the limited field strength achievable in these systems. Overhauser effect dynamic nuclear polarization (O-DNP), which transfers polarization from an unpaired electron to a nucleus by saturating an electron paramagnetic resonance transition with an oscillating radio frequency magnetic field, B 1e , can increase the polarization of low γ nuclei by hundreds or even thousands, enabling detection in a portable system. We have investigated the potential for O-DNP to enhance signals using (4-amino-2,2,6,6-tetramethylpiperidin-1-yl)oxyl (TEMPO hereafter) as a source of unpaired electrons in a homebuilt ultra-low field (ULF) O-DNP-NMR spectrometer. We have found, in general, that larger concentrations of TEMPO are required for effective O-DNP with low γ nuclei, which has a number of important effects. Spin exchange effects cause the EPR lines to overlap and ultimately merge at high concentrations of TEMPO, fundamentally increasing the maximum possible enhancement, while the electron–electron dipolar interaction reduces both longitudinal and transverse relaxation times for the electrons, dramatically increasing the required B 1e strength. The relationship between TEMPO concentration, B 1e magnitude and O-DNP enhancement is quantified, and strategies for achieving these fields are discussed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy

Purpose: In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. Methods: The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter’s trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter’s imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. Results: The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet’s orientation deviated from the main magnetic field direction. Fifteen catheters’ trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. Conclusions: The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.

60 APPLIED LIFE SCIENCES↗

Magnetic properties of the itinerant A- type antiferromagnet CaCo 2 P 2 studied by Co 59 and P 31 nuclear magnetic resonance

59 Co and 31 P nuclear magnetic resonance (NMR) measurements in external magnetic and zero magnetic fields have been performed to investigate the magnetic properties of the A-type antiferromagnetic (AFM) CaCo 2 P 2 . NMR data, especially the nuclear spin lattice relaxation rates 1/T 1 exhibiting a clear peak, provide clear evidence for the AFM transition at a Néel temperature of T N ~ 110 K. The magnetic fluctuations in the paramagnetic state were found to be three-dimensional ferromagnetic, suggesting ferromagnetic interaction between Co spins in the ab plane characterizes the spin correlations in the paramagnetic state. In the AFM state below TN, we have observed 59 Co and 31 P NMR signals under zero magnetic field. From 59 Co NMR data, the ordered magnetic moments of Co are found to be in ab plane and are estimated to be 0.35 μ B at 4.2 K. Furthermore, the external field dependence of 59 Co NMR spectrum in the AFM state suggests a very weak magnetic anisotropy of the Co ions and also provides microscopic evidence of canting the Co-ordered moments along the external magnetic field directions. The magnetic state of the Co ions in CaCo 2 P 2 is well explained by the local-moment picture in the AFM state, although the system is metallic, as seen by 1/T 1 T = constant behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pressure-driven amplification and penetration of resonant magnetic perturbations

We show that a resonant magnetic perturbation applied to the boundary of an ideal plasma screw-pinch equilibrium with nested surfaces can penetrate inside the resonant surface and into the core. The response is significantly amplified with increasing plasma pressure. We present a rigorous verification of nonlinear equilibrium codes against linear theory, showing excellent agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic resonance studies of three-layer FeNi/Bi/FeNi films

The interlayer coupling in three-layer FeNi/Bi/FeNi films is studied by electron magnetic resonance. The magnetic anisotropy at the permalloy–bismuth interface is shown to play a significant role in the formation of the magnetic state of the film structure. The interlayer coupling oscillation period is found to be about 8 nm. The interlayer coupling and the interface anisotropy and their temperature dependences are determined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A complete software application for automatic registration of x-ray mammography and magnetic resonance images

Purpose: This work presents a complete and automatic software application to aid radiologists in breast cancer diagnosis. The application is a fully automated method that performs a complete registration of magnetic resonance (MR) images and x-ray (XR) images in both directions (from MR to XR and from XR to MR) and for both x-ray mammograms, craniocaudal (CC), and mediolateral oblique (MLO). This new approximation allows radiologists to mark points in the MR images and, without any manual intervention, it provides their corresponding points in both types of XR mammograms and vice versa. Methods: The application automatically segments magnetic resonance images and x-ray images using the C-Means method and the Otsu method, respectively. It compresses the magnetic resonance images in both directions, CC and MLO, using a biomechanical model of the breast that distinguishes the specific biomechanical behavior of each one of its three tissues (skin, fat, and glandular tissue) separately. It makes a projection of both compressions and registers them with the original XR images using affine transformations and nonrigid registration methods. Results: The application has been validated by two expert radiologists. This was carried out through a quantitative validation on 14 data sets in which the Euclidean distance between points marked by the radiologists and the corresponding points obtained by the application were measured. The results showed a mean error of 4.2 ± 1.9 mm for the MRI to CC registration, 4.8 ± 1.3 mm for the MRI to MLO registration, and 4.1 ± 1.3 mm for the CC and MLO to MRI registration. Conclusions: A complete software application that automatically registers XR and MR images of the breast has been implemented. The application permits radiologists to estimate the position of a lesion that is suspected of being a tumor in an imaging modality based on its position in another different modality with a clinically acceptable error. The results show that the application can accelerate the mammographic screening process for high risk populations or for dense breasts.

60 APPLIED LIFE SCIENCES↗

Optically detected magnetic resonance of nitrogen vacancies in a diamond anvil cell using designer diamond anvils

Optically detected magnetic resonance of nitrogen vacancy centers in diamond offers a route to both DC and AC magnetometry in diamond anvil cells under high pressures (>3 GPa). However, a serious challenge to realizing experiments has been the insertion of microwave radiation into the sample space without screening by the gasket material. We utilize designer anvils with lithographically deposited metallic microchannels on the diamond culet as a microwave antenna. We detected the spin resonance of an ensemble of microdiamonds under pressure and measured the pressure dependence of the zero field splitting parameters. Furthermore, these experiments enable the possibility for all-optical magnetic resonance experiments on nanoliter sample volumes at high pressures.

36 MATERIALS SCIENCE↗

Correction of Q Factor Effects for Simultaneous Collection of Elemental Analysis and Relaxation Times by Nuclear Magnetic Resonance

A new method for measurement of elemental analysis by nuclear magnetic resonance (NMR) of unknown samples is discussed in this report as a quick and robust means to measure elemental ratios without the use of internal or external calibration standards. The determination of elemental ratios was done by normalizing the signal intensities by the frequency dependent quality factor (Q) and the gyromagnetic ratios (γ) for each measured nucleus. The correction for the frequency dependence was found by characterizing the output signal of the probe as a function of the quality factor (Q) and the frequency, and the correction for γ was discussed in a previous study. A Carr–Purcell–Meiboom–Gill (CPMG) pulse sequence was used for evaluation of the relative signal intensities, which allows for derivation of elemental ratios, and was correspondingly used to simultaneously measure the T 2 * of samples for an added parameter for more accurate identification of unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tumor Metabolism and Perfusion in Head and Neck Squamous Cell Carcinoma: Pretreatment Multimodality Imaging With {sup 1}H Magnetic Resonance Spectroscopy, Dynamic Contrast-Enhanced MRI, and [{sup 18}F]FDG-PET

Purpose: To correlate proton magnetic resonance spectroscopy ({sup 1}H-MRS), dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), and {sup 18}F-labeled fluorodeoxyglucose positron emission tomography ([{sup 18}F]FDG PET) of nodal metastases in patients with head and neck squamous cell carcinoma (HNSCC) for assessment of tumor biology. Additionally, pretreatment multimodality imaging was evaluated for its efficacy in predicting short-term response to treatment. Methods and Materials: Metastatic neck nodes were imaged with {sup 1}H-MRS, DCE-MRI, and [{sup 18}F]FDG PET in 16 patients with newly diagnosed HNSCC, before treatment. Short-term patient radiological response was evaluated at 3 to 4 months. Correlations among {sup 1}H-MRS (choline concentration relative to water [Cho/W]), DCE-MRI (volume transfer constant [K{sup trans}]; volume fraction of the extravascular extracellular space [v{sub e}]; and redistribution rate constant [k{sub ep}]), and [{sup 18}F]FDG PET (standard uptake value [SUV] and total lesion glycolysis [TLG]) were calculated using nonparametric Spearman rank correlation. To predict short-term responses, logistic regression analysis was performed. Results: A significant positive correlation was found between Cho/W and TLG ({rho} = 0.599; p = 0.031). Cho/W correlated negatively with heterogeneity measures of standard deviation std(v{sub e}) ({rho} = -0.691; p = 0.004) and std(k{sub ep}) ({rho} = -0.704; p = 0.003). Maximum SUV (SUVmax) values correlated strongly with MRI tumor volume ({rho} = 0.643; p = 0.007). Logistic regression indicated that std(K{sup trans}) and SUVmean were significant predictors of short-term response (p < 0.07). Conclusion: Pretreatment multimodality imaging using {sup 1}H-MRS, DCE-MRI, and [{sup 18}F]FDG PET is feasible in HNSCC patients with nodal metastases. Additionally, combined DCE-MRI and [{sup 18}F]FDG PET parameters were predictive of short-term response to treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase II Trial of Radiosurgery to Magnetic Resonance Spectroscopy-Defined High-Risk Tumor Volumes in Patients With Glioblastoma Multiforme

Purpose: To determine the efficacy of a Gamma Knife stereotactic radiosurgery (SRS) boost to areas of high risk determined by magnetic resonance spectroscopy (MRS) functional imaging in addition to standard radiotherapy for patients with glioblastoma (GBM). Methods and Materials: Thirty-five patients in this prospective Phase II trial underwent surgical resection or biopsy for a GBM followed by SRS directed toward areas of MRS-determined high biological activity within 2 cm of the postoperative enhancing surgical bed. The MRS regions were determined by identifying those voxels within the postoperative T2 magnetic resonance imaging volume that contained an elevated choline/N-acetylaspartate ratio in excess of 2:1. These voxels were marked, digitally fused with the SRS planning magnetic resonance image, targeted with an 8-mm isocenter per voxel, and treated using Radiation Therapy Oncology Group SRS dose guidelines. All patients then received conformal radiotherapy to a total dose of 60 Gy in 2-Gy daily fractions. The primary endpoint was overall survival. Results: The median survival for the entire cohort was 15.8 months. With 75% of recursive partitioning analysis (RPA) Class 3 patients still alive 18 months after treatment, the median survival for RPA Class 3 has not yet been reached. The median survivals for RPA Class 4, 5, and 6 patients were 18.7, 12.5, and 3.9 months, respectively, compared with Radiation Therapy Oncology Group radiotherapy-alone historical control survivals of 11.1, 8.9, and 4.6 months. For the 16 of 35 patients who received concurrent temozolomide in addition to protocol radiotherapeutic treatment, the median survival was 20.8 months, compared with European Organization for Research and Treatment of Cancer historical controls of 14.6 months using radiotherapy and temozolomide. Grade 3/4 toxicities possibly attributable to treatment were 11%. Conclusions: This represents the first prospective trial using selective MRS-targeted functional SRS combined with radiotherapy for patients with GBM. This treatment is feasible, with acceptable toxicity and patient survivals higher than in historical controls. This study can form the basis for a multicenter, randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High temperature spin dynamics in linear magnetic chains, molecular rings, and segments by nuclear magnetic resonance

We present the room temperature proton nuclear magnetic resonance (NMR) nuclear spin-lattice relaxation rate (NSLR) results in two 1D spin chains: the Heisenberg antiferromagnetic (AFM) Eu(hfac){sub 3}NITEt and the magnetically frustrated Gd(hfac){sub 3}NITEt. The NSLR as a function of external magnetic field can be interpreted very well in terms of high temperature spin dynamics dominated by a long time persistence of the decay of the two-spin correlation function due to the conservation of the total spin value for isotropic Heisenberg chains. The high temperature spin dynamics are also investigated in Heisenberg AFM molecular rings. In both Cr{sub 8} closed ring and in Cr{sub 7}Cd and Cr{sub 8}Zn open rings, i.e., model systems for a finite spin segment, an enhancement of the low frequency spectral density is found consistent with spin diffusion but the high cut-off frequency due to intermolecular anisotropic interactions prevents a detailed analysis of the spin diffusion regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗