Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Multi-dimensional incoherent Thomson scattering system in PHAse Space MApping (PHASMA) facility

A multi-dimensional incoherent Thomson scattering diagnostic system capable of measuring electron temperature anisotropies at the level of the electron velocity distribution function (EVDF) is implemented on the PHAse Space MApping facility to investigate electron energization mechanisms during magnetic reconnection. This system incorporates two injection paths (perpendicular and parallel to the axial magnetic field) and two collection paths, providing four independent EVDF measurements along four velocity space directions. For strongly magnetized electrons, a 3D EVDF comprised of two characteristic electron temperatures perpendicular and parallel to the local magnetic field line is reconstructed from the four measured EVDFs. As a result, validation of isotropic electrons in a single magnetic flux rope and a steady-state helicon plasma is presented.

47 OTHER INSTRUMENTATION↗

Overview of Nonintercepting Beam-Size Monitoring with Optical Diffraction Radiation

The initial demonstrations over the last several years of the use of optical diffraction radiation (ODR) as nonintercepting electron-beam-parameter monitors are reviewed. Developments in both far-field imaging and near-field imaging are addressed for ODR generated by a metal plane with a slit aperture, a single metal plane, and two-plane interferences. Polarization effects and sensitivities to beam size, divergence, and position will be discussed as well as a proposed path towards monitoring 10-micron beam sizes at 25 GeV.

43 PARTICLE ACCELERATORS↗

A range-based method to calibrate a magnetic spectrometer measuring the energy spectrum of the backward electron beam of a plasma focus

The electron beam emitted from the back of plasma focus devices is being studied as a radiation source for intraoperative radiation therapy applications. A plasma focus device is being developed for this purpose, and there is a need for characterizing its electron beam, particularly, insofar as the energy spectrum is concerned. The instrument used is a magnetic spectrometer. To calibrate this spectrometer, a procedure relying on the energy-range relation in Mylar has been devised and applied. By measuring the transmission through increasing thicknesses of the material, electron energies could be assessed and compared to the spectrometer readings. Thus, the original calibration of the instrument has been extended to higher energies and also to better accuracy. Methods and results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New micro-beam beamline at SPring-8, targeting at protein micro-crystallography

A new protein micro-crystallography beamline BL32XU at SPring-8 is under construction and scheduled to start operation in 2010. The beamline is designed to provide the stabilized and brilliant micro-beam to collect high-quality data from micro-crystals. The beamline consists of a hybrid in-vacuum undulator, a liquid-nitrogen cooled double crystal monochromator, and K-B focusing mirrors with large magnification factor. Development of data acquisition system and end station consists of high-precision diffractometer, high-efficiency area detector, sample auto-changer etc. are also in progress.

43 PARTICLE ACCELERATORS↗

COMPARISON OF FORCE-FREE CORONAL MAGNETIC FIELD MODELING USING VECTOR FIELDS FROM HINODE AND SOLAR DYNAMICS OBSERVATORY

Photospheric magnetic vector maps from two different instruments are used to model the nonlinear force-free coronal magnetic field above an active region. We use vector maps inferred from polarization measurements of the Solar Dynamics Observatory/Helioseismic and Magnetic Imager (HMI) and the Solar Optical Telescope's Spectropolarimeter (SP) on board Hinode. Besides basing our model calculations on HMI data, we use both SP data of original resolution and scaled down to the resolution of HMI. This allows us to compare the model results based on data from different instruments and to investigate how a binning of high-resolution data affects the model outcome. The resulting three-dimensional magnetic fields are compared in terms of magnetic energy content and magnetic topology. We find stronger magnetic fields in the SP data, translating into a higher total magnetic energy of the SP models. The net Lorentz forces of the HMI and SP lower boundaries verify their force-free compatibility. We find substantial differences in the absolute estimates of the magnetic field energy but similar relative estimates, e.g., the fraction of excess energy and of the flux shared by distinct areas. The location and extension of neighboring connectivity domains differ and the SP model fields tend to be higher and more vertical. Hence, conclusions about the magnetic connectivity based on force-free field models are to be drawn with caution. We find that the deviations of the model solution when based on the lower-resolution SP data are small compared to the differences of the solutions based on data from different instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

Generalized theory of double-resonance optical pumping of {sup 4}He

We present extensions to the theory of double-resonance laser pumping of {sup 4}He in the context of magnetometer instrumentation. This extended theory allows for arbitrary optical polarization, magnetic resonance (H{sub 1}) coil orientation, and overall instrument orientation relative to the ambient magnetic field. Steady-state solutions are presented for portions of the extended parameter space. These calculations are used to analyze the shot-noise-limited sensitivities for helium magnetometers for selected parameter values, and we find that linearly polarized light can have a relatively simple orientational dependence for a particular choice of angle between the H{sub 1} coils and the light polarization vector. Calculations are also compared to experimentally measured magnetic resonance curves, and a shot-noise limit on sensitivity of 6 fT/{radical}(Hz) is determined for a particular magnetometer apparatus using a cell 2.4 cm in diameter and 7.5 cm in length. This extended theory can be utilized to select optimal operational parameter values and obtain ideal sensitivities for helium magnetometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetism reflectometer study shows LiF layers improve efficiency in spin valve devices

New, more efficient materials for spin valves - a device used in magnetic sensors, random access memories, and hard disk drives - may be on the way based on research using the magnetism reflectometer at Oak Ridge National Laboratory (ORNL). Spin valve devices work by means of two or more conducting magnetic material layers that alternate their electrical resistance depending on the layers alignment. Giant magnetoresistance is a quantum mechanical effect first observed in thin film structures about 20 years ago. The effect is observed as a significant change in electrical resistance, depending on whether the magnetization of adjacent ferromagnetic layers is in a parallel or an antiparallel magnetic alignment. 'What we are doing here is developing new materials. The search for new materials suitable for injecting and transferring carriers with a preferential spin orientation is most important for the development of spintronics,' said Valeria Lauter, lead instrument scientist on the magnetism reflectometer at the Spallation Neutron Source (SNS), who collaborated on the experiment. The researchers discovered that the conductivity of such materials is improved when an organic polymer semiconductor layer is placed between the magnetic materials. Organic semiconductors are now the material of choice for future spin valve devices because they preserve spin coherence over longer times and distances than conventional semiconductors. While research into spin valves has been ongoing, research into organic semiconductors is recent. Previous research has shown that a 'conductivity mismatch' exists in spin valve systems in which ferromagnetic metal electrodes interface with such organic semiconductors as Alq3 ({pi}-conjugated molecule tris(8-hydroxy-quinoline) aluminium). This mismatch limits the efficient injection of the electrons from the electrodes at the interface with the semiconductor material. However, lithium fluoride (LiF), commonly used in light-emitting diodes, has been found to enhance the injection of electrons through the semiconductor. Researchers from the University of Alabama and ORNL used polarized neutrons at the magnetism reflectometer at SNS to investigate the electronic, magnetic, and structural properties of the electrodes in a novel system. In this system, the magnetic layers cobalt and Ni{sub 80}Fe{sub 20} are interfaced with spacer layers composed of the organic semiconductor Alq3. A coupling layer of LiF is inserted to separate the magnetized layers from the semiconductor. 'ALQ3 is an organic semiconductor material,' said Lauter. 'Normally in these systems a first magnetic layer is grown on a hard substrate so that one can get the controlled magnetic parameters. Then you grow the organic semiconductor layer, followed by another magnetic material layer, such as cobalt.' In addition to determining the effect of the LiF layers on the efficiency of the electron injection, the researchers wanted to determine the magnetic properties of the cobalt and Ni{sub 80}Fe{sub 20} as well as the interfacial properties: whether there is interdiffusion of cobalt through the LiF layer to the semiconductor, for example. The researchers used polarized neutrons at beam line 4A to probe the entire, layer-by-layer assembly of the system. 'Reflectometry with polarized neutrons is a perfect method to study thin magnetic films,' Lauter said. 'These thin films - if you put one on a substrate, you see it just like a mirror. However, this mirror has a very complicated internal multilayer structure. The neutrons look inside this complicated structure and characterize each and every interface. Due to the depth sensitivity of the method, we measure the structural and magnetic properties of each layer with the resolution of 0.5 nm. The neutron scattering results found that inserting LiF as a barrier significantly improves the quality of the interface, increasing the injection of electrons from the magnetic layer through the organic semiconductor in the spin valve and enhancing the overall properties of the system. In related work the magnetic properties of the cobalt film and the permalloy Ni{sub 80}Fe{sub 20} were characterized. Cobalt in particular needed attention, as it cannot be grown epitaxially (i.e., deposited) on an organic semiconductor film. Cobalt becomes polycrystalline or amorphous, and this affects its magnetic properties. The data from the first experiment showed that the cobalt layer in the system 'did not have typical magnetic properties,' Lauter said. 'The results showed that the cobalt had low magnetization. To improve the efficiency, the cobalt magnetization should be much higher. So this experiment helped us to improve the growth conditions and to get a cobalt layer with better magnetic properties.' In a subsequent experiment the researchers increased the magnetization of the cobalt, and a follow-up paper is in progress.

36 MATERIALS SCIENCE↗

Transport and Non-Invasive Position Detection of Electron Beams from Laser-Plasma Accelerators

The controlled imaging and transport of ultra-relativistic electrons from laser-plasma accelerators is of crucial importance to further use of these beams, e.g. in high peak-brightness light sources. We present our plans to realize beam transport with miniature permanent quadrupole magnets from the electron source through our THUNDER undulator. Simulation results demonstrate the importance of beam imaging by investigating the generated XUV-photon flux. In addition, first experimental findings of utilizing cavity-based monitors for non-invasive beam-position measurements in a noisy electromagnetic laser-plasma environment are discussed.

43 PARTICLE ACCELERATORS↗

Response induction coil magnetometers to perturbations in orientation

© 1996-2018 Society of Exploration Geophysicists. All rights reserved. We explore the data collected by a 3-component induction coil magnetometer system with respect to motion of the instruments in earths static magnetic field. The sensitivtiy of the inductiuon coil magnetometer leads to unprecediented accuracy on tilt measurements. We model the signals observed during seismic events as being perturbations in coil orientation. In theory, these perturbations can include ground roll, ocean motion, nearby cultural seismicity, or any other field with a tilting effect. Using data from a magnetic observatory near Parkfield CA we invert several time series of coil data during different levels of seismic activity in an attempt to determine the magnitudes of rotation at which our model accurately describes the coil data. Finally, we explore the transfer function between the coils and nearby seismic instruments (accelerometers, tiltmeters, and velocity seismometers).

Kappler, K↗

First flight performance of the Micro-X microcalorimeter X-ray sounding rocket

The flight of the Micro-X sounding rocket on July 22, 2018, marked the first operation of transition-edge sensors and their superconducting quantum interference device readouts in space. Here, the instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia A supernova remnant. Although a rocket pointing malfunction led to no time on-target, data from the flight were used to evaluate the performance of the instrument and demonstrate the flight viability of the payload. The instrument successfully achieved a stable cryogenic environment, executed all flight operations, and observed X-rays from the on-board calibration source. The flight environment did not significantly affect the performance of the detectors compared with ground operation. The flight provided an invaluable test of the impact of external magnetic fields and the instrument configuration on detector performance. This flight provides a milestone in the flight readiness of these detector and readout technologies, both of which have been selected for future X-ray observatories.

79 ASTRONOMY AND ASTROPHYSICS↗

The ratio R{sub dp} of the quasielastic nd {yields} p(nn) to the elastic np {yields} pn charge-exchange-process yields at the proton emitting angle {theta}{sub p,lab} = 0 deg. over 0.55-2.0 GeV neutron beam energy region. Experimental results

New experimental results on ratio R{sub dp} of the quasielastic charge-exchange yield at the outgoing proton angle {theta}{sub p,lab} = 0 deg. for the nd {yields} p(nn) reaction to the elastic np {yields} pn charge-exchange yield, are presented. The measurements were carried out at the Nuclotron of the Veksler and Baldin Laboratory of High Energies of the JINR (Dubna) at the neutron-beam kinetic energies of 0.55, 0.8, 1.0, 1.2, 1.4, 1.8, and 2.0 GeV. The intense neutron beam with small momentum spread was produced by breakup of deuterons which were accelerated and extracted to the experimental hall. In both reactions mentioned above the outgoing protons with the momenta p{sub p} approximately equal to the neutron-beam momentum p{sub n,beam} were detected in the directions close to the direction of incident neutrons, i.e., in the vicinity of the scattering angle {theta}{sub p,lab} = 0 deg. Measured in the same data-taking runs, the angular distributions of the charge-exchange-reaction products were corrected for the well-known instrumental effects and averaged in the vicinity of the incident-neutron-beam direction. These corrected angular distributions for every of nd {yields} p(nn) and np {yields} pn charge-exchange processes were proportional to the differential cross sections of the corresponding reactions. The data were accumulated by Delta-Sigma setup magnetic spectrometer with two sets of multiwire proportional chambers located upstream and downstream of the momentum analyzing magnet. Inelastic processes were considerably reduced by the additional detectors surrounding the hydrogen and deuterium targets. The time-of-flight system was applied to identify the detected particles. The accumulated data treatment and analysis, as well as possible sources of the systematic errors are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of HTS Wires at High Magnetic Fields

Fermilab is working on the development of high field magnet systems for ionization cooling of muon beams. The use of high temperature superconducting (HTS) materials is being considered for these magnets using Helium refrigeration. Critical current (I{sub c}) measurements of HTS conductors were performed at FNAL and at NIMS up to 28 T under magnetic fields at zero to 90 degree with respect to the sample face. A description of the test setups and results on a BSCCO-2223 tape and second generation (2G) coated conductors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Bypass Fluid Flow in an Active Magnetic Regenerative Liqueer

Active magnetic regenerators (AMR) with second order magnetocaloric materials operating below the Curie temperature have a unique property where the magnetized specific heat is lower than the demagnetized specific heat. The associated thermal mass unbalance allows a fraction of heat transfer fluid in the cold heat exchanger to bypass the magnetized regenerator. This cold bypassed fluid can precool a process stream as it returns to the hot side, thereby increasing the efficiency of liquefaction and reducing the cost of liquid cryogens. While researchers have been aware of this phenomenon for decades, experimental performance improvements from bypass fluid flow have yet to be reported in open literature. In the present work, the net cooling power of an active magnetic regenerative liquefier is investigated as a function of the bypass ow fraction. Experiments are performed at a fixed temperature span that yield a 25% improvement in net cooling power, affirming the potential of bypass cooling power.

active magnetic regenerator, hydrogen, liquefacati↗

Status of RHIC head-on beam-beam compensation project

Two electron lenses are under construction for RHIC to partially compensate the head-on beam-beam effect in order to increase both the peak and average luminosities. The final design of the overall system is reported as well as the status of the component design, acquisition, and manufacturing. An overview of the RHIC head-on beam-beam compensation project is given in [1], and more details in [2]. With 2 head-on beam-beam interactions in IP6 and IP8, a third interaction with a low-energy electron beam is added near IP10 to partially compensate the the head-on beam-beam effect. Two electron lenses are under construction, one for each ring. Both will be located in a region common to both beams, but each lens will act only on one beam. With head-on beam-beam compensation up to a factor of two improvement in luminosity is expected together with a polarized source upgrade. The current RHIC polarized proton performance is documented in Ref. [4]. An electron lens (Fig. 1) consists of an DC electron gun, warm solenoids to focus the electron beam during transport, a superconducting main solenoid in which the interaction with the proton beam occurs, steering magnets, a collector, and instrumentation. The main developments in the last year are given below. The experimental program for polarized program at 100 GeV was expected to be finished by the time the electron lenses are commissioned. However, decadal plans by the RHIC experiments STAR and PHENIX show a continuing interest at both 100 GeV and 250 GeV, and a larger proton beam size has been accommodated in the design (Tab. 1). Over the last year beam and lattice parameters were optimized, and RHIC proton lattices are under development for optimized electron lens performance. The effect of the electron lens magnetic structure on the proton beam was evaluated, and found to be correctable. Experiments were done in RHIC and the Tevatron.

43 PARTICLE ACCELERATORS↗

Qualification of the US made conductors for ITER TF magnet system

The US Domestic Agency (USDA) is one of the six suppliers of the TF conductor for ITER. In order to qualify conductors according to ITER requirements we prepared several lengths of the CICC and short samples for testing in the SULTAN facility in CRPP, Switzerland. We also fully characterized the strands that were used in these SULTAN samples. Fabrication experience and test results are presented and discussed.

42 ENGINEERING↗

AC electrical transport detection of magnetic properties of small, granular, and heterogeneous samples

Experimental constraints and sample limitations can preclude ideal measurements of electrical transport properties of materials. In such situations, AC electrical transport methods are often employed due to a significant increase in signal-to-noise ratio they can provide. However, dynamic effects that are not often accounted for may be present that may modify the signals in these measurements. In particular, dynamic filtering effects are prominent in small, granular, and heterogeneous materials. We demonstrate that a lock-in amplifier based circuit can distinguish between these DC transport and AC filtering effects. Here, we further demonstrate that this filtering can reveal distinct signatures of magnetic transitions while providing a measure of sample quality.

47 OTHER INSTRUMENTATION↗