At least 145 records · Page 8

Heating of coronal loops by phase-mixid shear Alfven waves

The dissipation of shear Alfven waves in a coronal loop driven externally by an incident wave in the subcoronal region is investigated. The phase mixing of these incident shear Alfven waves serves as the dissipation mechanism in the corona. The wave solution found by Heyvaerts and Priest (1983) for coronal holes is used to compute the total energy deposited in a loop. The energy deposited is shown to depend upon the magnetic diffusivity nu(m) and viscosity nu(v), contrary to the conclusion of authors who assumed that coronal loops are perfect resonators. The energy deposited in a three-layer model is computed for incident waves with periods of five minutes or five seconds. For a five-minute period, almost no energy is deposited, especially for small loops. For a five-second period, a substantial amount of energy is deposited in the loop, but not enough to account for the heating of small loops.

Abdelatif, Toufik E.

The formation flare loops by magnetic reconnection and chromospheric ablation

Noncoplanar compressible reconnection theory is combined here with simple scaling arguments for ablation and radiative cooling to predict average properties of hot and cool flare loops as a function of the coronal vector magnetic field. For a coronal field strength of 100 G, the temperature of the hot flare loops decreases from 1.2 x 10 to the 7th K to 4.0 x 10 to the 6th K as the component of the coronal magnetic field perpendicular to the plane of the loops increases from 0 percent to 86 percent of the total field. When the perpendicular component exceeds 86 percent of the total field or when the altitude of the reconnection site exceeds 10 to the 6th km, flare loops no longer occur. Shock-enhanced radiative cooling triggers the formation of cool H-alpha flare loops with predicted densities of roughly 10 to the 13th/cu cm, and a small gap of roughly 1000 km is predicted to exist between the footpoints of the cool flare loops and the inner edges of the flare ribbons.

Forbes, T. G.

A comparison of Manchester symbol tracking loops for block 5 applications

The linearized tracking errors of three Manchester (biphase coded) symbol tracking loops are compared to determine which is appropriate for Block 5 receiver applications. The first is a nonreturn to zero (NRZ) symbol synchronizer loop operating at twice the symbol rate (NRZ x 2) so that it operates on half symbols. The second near optimally processes the mid-symbol transitions and ignores the between symbol transitions. In the third configuration, the first two approaches are combined as a hybrid to produce the best performance. Although this hybrid loop is the best at low symbol signal to noise ratios (SNRs), it has about the same performance as the NRZ x 2 loop at higher SNRs (greater than 0-dB E sub s/N sub 0). Based on this analysis, it is tentatively recommended that the hybrid loop be implemented for Manchester data in the Block 5 receiver. However, the high data rate case and the hardware implications of each implementation must be understood and analyzed before the hybrid loop is recommended unconditionally.

Holmes, J. K.

The thermal stability of coronal loops - Numerical simulations

The radiative stability of thermally isolated coronal loops with free-flow boundary conditions by nonlinear numerical simulation are studied. A chromosphere-to-corona loop equilibrium (including the option of a deep chromosphere) is first established by following the nonlinear evolution from an initial isothermal state with rigid boundaries. The end conditions are then changed, to allow free flow and to fix the temperature, and investigate the response to nonisobaric perturbations. Within a family of loops of the same pressure, long hot loops to be stable and short cool loops to be unstable to the thermal chromospheric-expansion mode are found. The stable cases remain so, even when long chromospheric ends and/or gravity are added. In those cases which are unstable, the subsequent nonlinear evolution which exhibits swelling of the chromosphere until the entire loop becomes cool and dense are followed.

Mok, Y.

Open-Loop Acquisition Of Frequency In BPSK

Proposed open-loop analog/digital signal-processing system would be Costas-loop error detector functioning in closed-loop manner overall. Detector estimates difference between frequency of input signal and internal reference oscillator. Estimate used to close frequency-control loop. Precise symbol timing not necessary. Performance better than systems that effect open-loop acquisition using integrators instead of low-pass filters in arms of Costas loops and in which performance varies with symbol timing.

Shah, Biren N.

Identification of system, observer, and controller from closed-loop experimental data

This paper considers the identification problem of a system operating in closed-loop with an existing feedback controller. The closed-loop system is excited by a known excitation signal, and the resulting time histories of the closed-loop system response and the feedback signal are measured. From the time history data, the algorithm computes the Markov parameters of a closed-loop observer, from which the Markov parameters of the individual open-loop plant, observer, and controller are recovered. A state space model of the open-loop plant and the gain matrices for the controller and the observer are then realized. The results of the paper are demonstrated by an example using actual aircraft flutter test data.

Juang, Jer-Nan

Digital tracking loops for a programmable digital modem

In this paper, an analysis and hardware emulation of the tracking loops for a very flexible programmable digital modem (PDM) will be presented. The modem is capable of being programmed for 2, 4, 8, 16-PSK, 16-QAM, MSK, and Offset-QPSK modulation schemes over a range of data rates from 2.34 to 300 Mbps with programmable spectral occupancy from 1.2 to 1.8 times the symbol rate; these operational parameters are executable in burst or continuous mode. All of the critical processing in both the modulator and demodulator is done at baseband with very high-speed digital hardware and memory. Quadrature analog front-ends are used for translation between baseband and the IF center frequency. The modulator is based on a table lookup approach, where precomputed samples are stored in memory and clocked out according to the incoming data pattern. The sample values are predistorted to counteract the effects of the other filtering functions in the link as well as any transmission impairments. The demodulator architecture was adapted from a joint estimator-detector (JED) mathematical analysis. Its structure is applicable to most signalling formats that can be represented in a two-dimensional space. The JED realization uses interdependent, mutually aiding tracking loops with post-detection data feedback. To expedite and provide for more reliable synchronization, initial estimates for these loops are computed in a parallel acquisition processor. The cornerstone of the demodulator realization is the pre-averager received data filter which allows operation over a broad range of data rates without any hardware changes and greatly simplifies the implementation complexity. The emulation results confirmed tracking loop operation over the entire range of operational parameters listed above, as well as the capability of achieving and maintaining synchronization at BER's in excess of 10(exp -1). The emulation results also showed very close agreement with the tracking loop analysis, and validated the resolution apportionment of the various hardware elements in the tracking loops.

Poklemba, John J.

Thickness variations along coronal loops observed by the Soft X-ray Telescope on Yohkoh

The paper presents preliminary results of an investigation of thickness variations along coronal loops observed with the Yohkoh Soft X-ray Telescope (SXT), using observations from ten loops selected from the SXT data. The quantitative results indicate that coronal X-ray loops do not expand. This contradicts the expectation that, if plasma loops coincide with magnetic loops, many loops must be significantly broader at their tops than at their foot points. Possible interpretations of the obtained results are proposed.

Klimchuk, James A.

Isolated and coupled superquadric loop antennas for mobile communications applications

This work provides an investigation of the performance of loop antennas for use in mobile communications applications. The analysis tools developed allow for high flexibility by representing the loop antenna as a superquadric curve, which includes the case of circular, elliptical, and rectangular loops. The antenna may be in an isolated environment, located above an infinite ground plane, or placed near a finite conducting plate or box. In cases where coupled loops are used, the two loops may have arbitrary relative positions and orientations. Several design examples are included to illustrate the versatility of the analysis capabilities. The performance of coupled loops arranged in a diversity scheme is also evaluated, and it is found that high diversity gain can be achieved even when the antennas are closely spaced.

Jensen, Michael A.

Material Data Representation of Hysteresis Loops for Hastelloy X Using Artificial Neural Networks

The artificial neural network (ANN) model proposed by Rumelhart, Hinton, and Williams is applied to develop a functional approximation of material data in the form of hysteresis loops from a nickel-base superalloy, Hastelloy X. Several different ANN configurations are used to model hysteresis loops at different cycles for this alloy. The ANN models were successful in reproducing the hysteresis loops used for its training. However, because of sharp bends at the two ends of hysteresis loops, a drift occurs at the corners of the loops where loading changes to unloading and vice versa (the sharp bends occurred when the stress-strain curves were reproduced by adding stress increments to the preceding values of the stresses). Therefore, it is possible only to reproduce half of the loading path. The generalization capability of the network was tested by using additional data for two other hysteresis loops at different cycles. The results were in good agreement. Also, the use of ANN led to a data compression ratio of approximately 22:1.

Alam, Javed

Measuring electrically charged particle fluxes in space using a fiber optic loop sensor

The purpose of this program was to demonstrate the potential of a fiber optic loop sensor for the measurement of electrically charged particle fluxes in space. The key elements of the sensor are a multiple turn loop of low birefringence, single mode fiber, with a laser diode light source, and a low noise optical receiver. The optical receiver is designed to be shot noise limited, with this being the limiting sensitivity factor for the sensor. The sensing element is the fiber optic loop. Under a magnetic field from an electric current flowing along the axis of the loop, there is a non-vanishing line integral along the fiber optic loop. This causes a net birefringence producing two states of polarization whose phase difference is correlated to magnetic field strength and thus, current in the optical receiver electronic processing. The objectives in this program were to develop a prototype laser diode powered fiber optic sensor. The performance specification of a minimum detectable current density of 1 (mu)amp/sq m-(radical)Hz, should be at the shot noise limit of the detection electronics. OPTRA has successfully built and tested a 3.2 m diameter loop with 137 turns of low birefringence optical fiber and achieved a minimum detectable current density of 5.4 x 10(exp-5) amps/(radical)Hz. If laboratory space considerations were not an issue, with the length of optical fiber available to us, we would have achieved a minimum detectable current density of 4 x 10(exp -7) amps/(radical)Hz.

Source record

Space Station evolution study oxygen loop closure

In the current Space Station Freedom (SSF) Permanently Manned Configuration (PMC), physical scars for closing the oxygen loop by the addition of oxygen generation and carbon dioxide reduction hardware are not included. During station restructuring, the capability for oxygen loop closure was deferred to the B-modules. As such, the ability to close the oxygen loop in the U.S. Laboratory module (LAB A) and the Habitation A module (HAB A) is contingent on the presence of the B modules. To base oxygen loop closure of SSF on the funding of the B-modules may not be desirable. Therefore, this study was requested to evaluate the necessary hooks and scars in the A-modules to facilitate closure of the oxygen loop at or subsequent to PMC. The study defines the scars for oxygen loop closure with impacts to cost, weight and volume and assesses the effects of byproduct venting. In addition, the recommended scenarios for closure with regard to topology and packaging are presented.

Wood, M. G.

Performance evaluation of digital phase-locked loops for advanced deep space transponders

The performances of the digital phase-locked loops (DPLL's) for the advanced deep-space transponders (ADT's) are investigated. DPLL's considered in this article are derived from the analog phase-locked loop, which is currently employed by the NASA standard deep space transponder, using S-domain to Z-domain mapping techniques. Three mappings are used to develop digital approximations of the standard deep space analog phase-locked loop, namely the bilinear transformation (BT), impulse invariant transformation (IIT), and step invariant transformation (SIT) techniques. The performance in terms of the closed loop phase and magnitude responses, carrier tracking jitter, and response of the loop to the phase offset (the difference between in incoming phase and reference phase) is evaluated for each digital approximation. Theoretical results of the carrier tracking jitter for command-on and command-off cases are then validated by computer simulation. Both theoretical and computer simulation results show that at high sampling frequency, the DPLL's approximated by all three transformations have the same tracking jitter. However, at low sampling frequency, the digital approximation using BT outperforms the others. The minimum sampling frequency for adequate tracking performance is determined for each digital approximation of the analog loop. In addition, computer simulation shows that the DPLL developed by BT provides faster response to the phase offset than IIT and SIT.

Nguyen, T. M.

The bright knots at the tops of soft X-ray flare loops: Quantitative results from Yohkoh

Soft X-ray Telescope (SXT) observations from the Japanese Yohkoh spacecraft have shown that confined bright regions are common features at the tops of flare loops throughout most of the duration of the flares. In this paper we present quantitative results for these flare knots, in relation to other flare regions, for four relatively 'simple' flares. Emission measure distributions, electron temperatures, and electron densities are derived from SXT and Yohkoh Bragg Crystal Spectrometer (BCS) observations. The four flares selected are dominated by what appear to be single-loop structures, with bright knots at the loop tops. The flares are neither long-duration nor impulsive events. The spatial distributions of brightness and emission measure in the flares are found to be quite similar for all four events, even though there are significant differences in dynamical behavior between at least two of the events. Temperatures and densities calculated for these flares are consistent with previous results from many solar experiments. An investigation of intensity correlations between adjacent pixels at the tops of the loops suggests the existence of local disturbances in the magnetic loops that occur on spatial scales less than the radii of the loops.

Doschek, G. A.

Iterative LQG Controller Design Through Closed-Loop Identification

This paper presents an iterative Linear Quadratic Gaussian (LQG) controller design approach for a linear stochastic system with an uncertain open-loop model and unknown noise statistics. This approach consists of closed-loop identification and controller redesign cycles. In each cycle, the closed-loop identification method is used to identify an open-loop model and a steady-state Kalman filter gain from closed-loop input/output test data obtained by using a feedback LQG controller designed from the previous cycle. Then the identified open-loop model is used to redesign the state feedback. The state feedback and the identified Kalman filter gain are used to form an updated LQC controller for the next cycle. This iterative process continues until the updated controller converges. The proposed controller design is demonstrated by numerical simulations and experiments on a highly unstable large-gap magnetic suspension system.

Hsiao, Min-Hung

On Heating Large Bright Coronal Loops by Magnetic Microexplosions at their Feet

In previous work, by registering Yohkoh SXT coronal X-ray images with MSFC vector magnetograms, we found that: (1) many of the larger bright coronal loops rooted at one or both ends in an active region are rooted around magnetic islands of included polarity, (2) the core field encasing the neutral line encircling the island is strongly sheared, and (3) this sheared core field is the seat of frequent microflares. This suggests that the coronal heating in these extended bright loops is driven by many small explosive releases of stored magnetic energy from the sheared core field at their feet, some of which magnetic microexplosions also produce the microflare heating in the core fields. In this paper, we show that this scenario is feasible in terms of the energy Abstract: required for the observed coronal heating and the magnetic energy available in the observed sheared core fields. In a representative active region, from the X-ray and vector field data, we estimate the coronal heating consumption by a selected typical large bright loop, the coronal heating consumption by a typical microflare at the foot of this loop, the frequency of microflares at the foot, and the available magnetic energy in the microflaring core field. We find that: (1) the rate of magnetic energy release to power the microflares at the foot (approx. 6 x 10(ext 25)erg/s) is enough to also power the coronal heating in the body of the extended loop (approx. 2 x l0(exp 25 erg/s), and (2) there is enough stored magnetic energy in the sheared core field to sustain the microflaring and extended loop heating for about a day, which is a typical time for buildup of neutral-line magnetic shear in an active region. This work was funded by the Solar Physics Branch of NASA's Office of Space Science through the SR&T Program and the SEC Guest Investigator Program.

Moore, Ronald L

Investigation of Inner Loop Flight Control Strategies for High-Speed Research

This report describes the activities and findings conducted under contract NAS1-19858 with NASA Langley Research Center. Subject matter is the investigation of suitable flight control design methodologies and solutions for large, flexible high-speed vehicles. Specifically, methodologies are to address the inner control loops used for stabilization and augmentation of a highly coupled airframe system possibly involving rigid-body motion, structural vibrations, unsteady aerodynamics, and actuator dynamics. Techniques considered in this body of work are primarily conventional-based, and the vehicle of interest is the High-Speed Civil Transport (HSCT). Major findings include 1) current aeroelastic vehicle modeling procedures require further emphasis and refinement, 2) traditional and nontraditional inner loop flight control strategies employing a single feedback loop do not appear sufficient for highly flexible HSCT class vehicles, 3) inner loop flight control systems will, in all likelihood, require multiple interacting feedback loops, and 4) Ref. H HSCT configuration presents major challenges to designing acceptable closed-loop flight dynamics.

Newman, Brett

Capillary Limit in a Loop Heat Pipe with Dual Evaporators

This paper describes a study on the capillary limit of a loop heat pipe (LHP) with two evaporators and two condensers. Both theoretical analysis and experimental investigation are conducted. Tests include heat load to one evaporator only, even heat loads to both evaporators and uneven heat load to both evaporators. Results show that after the capillary limit is exceeded, vapor will penetrate through the wick of the weaker evaporator and the compensation chamber (CC) of that evaporator will control the loop operating temperature regardless of which CC has been in control prior to the event Because the evaporator can tolerate vapor bubbles, the loop may continue to work and reach a new steady state at a higher operating temperature. The loop may even function with a modest increase in the heat load past the capillary limit With a heat load to only one evaporator, the capillary limit can be identified by rapid increases in the operating temperature and in the temperature difference between the evaporator and the CC. However, it is more difficult to tell when the capillary limit is exceeded if heat loads are applied to both evaporators. In all cases, the loop can recover by reducing the heat load to the loop.

Ku, Jentung