At least 145 records · Page 8

Modular DC circuit breaker with integrated energy storage for future DC networks

A T-breaker is an all-in-one solution for dc microgrid fault protection, power flow control, and power quality improvement. A T-breaker features a modular multilevel “T” structure with integrated energy storage devices. The two horizontal arms of the T-breaker realize fault current breaking, load voltage compensation, and power flow control; and the vertical arm of the T-breaker realizes shunt compensation. The configuration provides excellent voltage scalability and relaxes the requirements on the switching signal synchronization during fault transients. The local energy storage in sub-modules eases the fault energy dissipation requirement placed on the traditionally-adopted surge arrestors. The modular multilevel structure also offers immense control flexibility for all types of targeted functions of the provided T-breaker.

Wang, Jin↗

Power Flow Models of Grid-Forming Inverters in Unbalanced Distribution Grids

Load unbalance in electric distribution systems is unavoidable. Unbalanced load currents will lead to negative sequence (NS) voltages that may damage electric equipment. Unbalanced power flow analysis is a common tool to detect and mitigate NS voltage issues and requires accurate models of grid components. While traditional source models are available, grid-forming (GFM) inverter models are not well developed. GFM inverters implement various control strategies, which affect their power flow models. Here, in this paper, a novel GFM inverter model considering control effects is proposed. We show that for some control methods, unbalanced system loading will lead to unbalanced terminal voltages of the GFM inverters, which are modeled through an equivalent negative sequence impedance. The proposed models are initially validated using a simple test circuit. Then, they are applied in the power flow analysis on the IEEE 13-bus and 34-bus systems to demonstrate the accuracy improvement over the state-of-the-art. Using time-domain simulations as benchmarks, we show that the proposed models reduce the calculation error of negative sequence voltages by at least 25% in unbalanced distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparison of Load Models for Estimating Electrical Efficiency in DC Microgrids: Preprint

This paper compares several electrical load models for estimating the efficiency of DC vs. AC distribution in microgrids. Candidate models include energy balance, harmonic power flow, and time-domain modeling. Model results are compared with numerical studies and validated with experimental measurements. Based on quantitative and qualitative considerations, the most appropriate load modeling approach for larger-scale DC distribution efficiency studies is proposed.

DC distribution↗

Benchmarking of three DWM-based wake models at below-rated wind speeds

Wind turbine wake models are essential tools for predicting power losses and structural loads in wind farms. Among these, the dynamic wake meandering (DWM) model, included as a recommended approach in the International Electrotechnical Commission design standard, is a widely used engineering-fidelity method that balances accuracy and computational cost. This study compares the performance of three DWM-based wake model implementations (from the Technical University of Denmark, the National Renewable Energy Laboratory, and the Institute for Energy Technology) under below-rated wind speed conditions. Model predictions of wake flow, power output, and structural loads for a four-turbine row are evaluated across different ambient turbulence levels and wind-direction misalignments and compared against high-fidelity large-eddy simulation results. All three models captured the overall wake evolution and mean turbine performance with reasonable accuracy; their predicted time-averaged thrust and power were typically within 5 %–10 % of the large-eddy simulation benchmark. However, notable differences emerged in wake structure and unsteady load predictions, with discrepancies increasing for turbines further downstream. These differences highlight the importance of modelling choices such as wake summation and turbulence treatment, which strongly influence power-deficit and fatigue-load predictions. Comparison with large-eddy simulations reveals each approach's strengths and weaknesses, indicating where improvements are needed. Overall, the findings point to specific refinements for DWM models to improve their fidelity, ultimately enabling more robust wake predictions for wind farm design and operation.

17 WIND ENERGY↗

Newton-Raphson AC Power Flow Convergence Based on Deep Learning Initialization and Homotopy Continuation

Power flow forms the basis of many power system studies. With the increased penetration of renewable energy, grid planners tend to perform multiple power flow simulations under various operating conditions and not just selected snapshots at peak or light load conditions. Getting a converged AC power flow (ACPF) case remains a significant challenge for grid planners especially in large power grid networks. This paper proposes a two-stage approach to improve Newton-Raphson ACPF convergence and was applied to a 6102 bus Electric Reliability Council of Texas (ERCOT) system. The first stage utilizes a deep learning-based initializer with data re-training. Here a deep neural network (DNN) initializer is developed to provide better initial voltage magnitude and angle guesses to aid in power flow convergence. This is because Newton-Raphson ACPF is quite sensitive to the initial conditions and bad initialization could lead to divergence. The DNN initializer includes a data re-training framework that improves the initializer's performance when faced with limited training data. The DNN initializer successfully solved 3,285 cases out of 3,899 non-converging dispatch and performed better than random forest and DC power flow initialization methods. ACPF cases not solved in this first stage are then passed through a hot-starting algorithm based on homotopy continuation with switched shunt control. The hot-starting algorithm successfully converged 416 cases out of the remaining 614 non-converging ACPF dispatch. In conclusion, the combined two-stage approach achieved a 94.9% success rate, by converging a total of 3,701 cases out of the initial 3,899 unsolved cases.

Deep learning↗

Countercurrent flow characteristics of next generation solvent in novel 3D printed columns for carbon capture

Solvent based absorption for carbon dioxide capture in a packed column is being considered as an efficient technology for the decarbonization process of point source. Significant efforts are underway to improve the design of packings with the cutting edge 3D printing technology for efficient carbon capture. Accordingly, multiphase flow studies were conducted to assess the performance of novel 3D printed columns with various triply periodic minimal surface (TPMS) designs. The effects of solvent properties, liquid and gas loads on the performance of TPMS columns are extensively explored. Hydrodynamics of the potential water-lean solvents (EEMPA) as well as aqueous monoethanolamine (MEA) solvent for carbon capture are evaluated and compared. The interfacial area and liquid holdup increase with increasing liquid loads (q L ) for TPMS columns. Schwarz column consistently shows the highest liquid holdup value. The EEMPA exhibits higher values for the interfacial area (10–15 %) and liquid holdup (~4 %) in comparison to the MEA. TPMS columns exhibit the intermediate value of dry pressure drop between the random and the structure packed columns. Among selected TPMS columns, the gyroid packing shows the lowest pressure drop. The gas load has marginal impact on the interfacial area at lower value while a higher gas load leads to column’s flooding. Prior to the flooding, the interfacial area in TMPS packings rises with increased gas load at a fixed liquid load except Schwarz packing where interfacial area is incentive to the gas load. Additionally, the liquid holdup and wet pressure drop rise as gas load increases in TPMS columns. Overall, Fisher Koch packing is more susceptible to flood as compared to other TPMS packings. Flow regimes: loading and flooding are also delineated in the TPMS packings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration: Preprint

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance Evaluation and Optimal Design Analysis of Continuous-Operation Solar-Driven Cooling Absorption Systems With Thermal Energy Storage

A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.

cooling load↗

Control methods for mitigating flow oscillations in a supercritical CO 2 recompression closed Brayton cycle

A dynamic model of a 10 MWe supercritical CO 2 (sCO 2 ) recompression closed Brayton power generation cycle is used to investigate control methods for mitigating oscillations in flow conditions and power demand load, especially as the load ramp rate is increased and the load setpoint is more closely tracked. The focus is on control of the main compressor inlet temperature (MCIT) since oscillations are prompted by the strong nonlinearities in sCO 2 fluid properties near the critical point and by changes in system inventory for efficient load management. In this study, the oscillatory behavior during load ramping is first shown and then two potential control solutions for substantially reducing oscillations are given: 1) the use of the main compressor inlet guide vanes (IGV) and 2) bypassing a portion of the sCO 2 around the cooler to maintain the MCIT. These control methods reduce the effect of cycle feedback from interactions between the MCIT and load. When implementing either control method, a load setpoint ramp of 7.5%/min was maintainable while achieving closer load setpoint tracking with limited oscillations. Finally, the impact of sensor noise on the control was examined since derivative action was used in the IGV and cooler sCO 2 bypass control. Finally, while some effect was evident, signal noise was not problematic to the control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of end-of-shift respirable crystalline silica monitoring to construction

A pilot project was conducted to determine the effect of common construction dusts as interferences in a new portable end-of-shift (EoS), direct-on-filter (DoF) sampling and analysis method for respirable crystalline silica (RCS), in this case, quartz. Construction dusts were prepared from plaster, drywall, cement and brick by grinding, aerosolizing, and collecting respirable dust with high flow rate cyclones. Filters were loaded with different levels of commercial α-quartz powder Min-u-Sil 5, and different levels of interfering dusts, singly and in combination. Samples were analyzed by Fourier Transform Infrared Spectroscopy (FTIR). Good correlations were found between nominal quartz loading (0 µg, 25 µg, 50 µg, and 100 µg) adjusted for quartz in the interfering dust and FTIR absorbance alone and in the presence of all interfering dusts. The slopes of the correlations were similar whether the loading was quartz without interference, or with plaster, drywall, and cement dusts, regardless of quantity. The results show that (a) plaster and drywall dusts do not interfere substantially; (b) cement does not interfere, but a change in the intercept suggests an effect on the background absorbance of the filter; and (c) in addition to having a substantial quartz content, brick dust contains an additional material, probably a silicate mineral, which interferes with the quartz peak. Thus, the presence of cement leads to lower quartz values and brick leads to higher values, but overall, 83% of the quartz contents predicted from the calibration data agreed within 50% of the adjusted nominal loadings within the range 20–110 µg. This result is encouraging given the high levels of interfering dusts. Nine samples loaded with smaller amounts of all four dusts together gave results within 25% of the adjusted nominal loadings. A single mixture addition of the dusts to the filter gave tighter variance in results than sequential additions. Unexpectedly, the two Certified Reference Materials (CRMs) 1878a and 1878b, gave different results when used to calibrate XRD analysis of Min-u-Sil 5.

42 ENGINEERING↗

Analysis and Control of a Three-Port Converter with High-Frequency AC Link for Hybrid Unmanned/Autonomous Aerial Vehicles

In this study, a three-port resonant converter with a high-frequency isolation link for hybrid unmanned/autonomous aerial vehicle (UAV/AAV) applications is analyzed. The rectified engine-generator set output supplies the first input ports while the other is connected to a battery energy storage system. Input ports consist of half-bridge high-frequency inverters, whereas output port utilizes a semi-bridgeless active rectifier. This rectifier is formed by replacing rectifier low-side diodes with active switching devices. A phase-shift duty-cycle control is implemented for switching signals to regulate the power share and flow between ports. The proposed control system implemented achieves zero voltage switching (ZVS), reduces switching losses, and minimum current flow optimization ensures regulation in a wide range of output power. Compared to the existing bidirectional pulse width modulation (PWM) converters, the proposed system decreases the number of power conversion stages and provides centralized control without needing communications between the ports. The proposed control technique operating in closed-loop control achieves the power flow between ports under various load conditions. Finally, theoretical analysis demonstrates the proposed converter’s viability and laboratory experimental validations at 500 W full power.

33 ADVANCED PROPULSION SYSTEMS↗

Using Machine Learning Tools to Predict Compressor Stall

Clean energy has become an increasingly important consideration in today’s power systems. As the push for clean energy continues, many coal-fired power plants are being decommissioned in favor of renewable power sources such as wind and solar. However, the intermittent nature of renewables means that dynamic load following traditional power systems is crucial to grid stability. With high flexibility and fast response at a wide range of operating conditions, gas turbine systems are poised to become the main load following component in the power grid. Yet, rapid changes in load can lead to fluid flow instabilities in gas turbine power systems. These instabilities often lead to compressor surge and stall, which are some of the most critical problems facing the safe and efficient operation of compressors in turbomachinery today. Although the topic of compressor surge and stall has been extensively researched, no methods for early prediction have been proven effective. This study explores the utilization of machine learning tools to predict compressor stall. The long short-term memory (LSTM) model, a form of recurrent neural network (RNN), was trained using real compressor stall datasets from a 100 kW recuperated gas turbine power system designed for hybrid configuration. Two variations of the LSTM model, classification and regression, were tested to determine optimal performance. The regression scheme was determined to be the most accurate approach, and a tool for predicting compressor stall was developed using this configuration. Overall, results show that the tool is capable of predicting stalls 5–20 ms before they occur. With a high-speed controller capable of 5 ms time-steps, mitigating action could be taken to prevent compressor stall before it occurs.

42 ENGINEERING↗

U.S. Geothermal District Heating Systems and Funding Data

This dataset contains detailed information on geothermal district heating (GDH) systems across the United States, including technical specifications, costs, energy usage, and funding sources. Data includes system details such as state, site, location, operational years, temperature, flow rate, capacity, energy use, load factor, costs (original, updated, and operational), funding sources, employment impact, and project status. Additionally included are contributions to GDH systems, including federal, state, and local grants, as well as loans from agencies such as USDA and USDOE. This dataset serves as a resource for analyzing the economic and technical landscape of geothermal district heating in the United States.

15 GEOTHERMAL ENERGY↗

Final Report on Predictive Analyses of PRD as Function of Anomalies

This report summarizes the work completed in FY-2024 to analyze the power reactivity decrement (PRD) concepts of the ARC-100 core. The PRD has been traditionally defined by the reactivity change from a hot zero power (HZP) to a particular power. Consequently, the PRD accounts for the core reactivity changes due to increase coolant temperature gradient axially and radially across the core, and increased fuel temperature. The coolant temperature gradient leads to sodium and structure density changes, to radial core expansion from assembly flowering and bowing (due to axial and radial temperature gradients within the assemblies), and to control rod driveline thermal expansion. The fuel temperature increase associated with coolant temperature and power increases leads to Doppler effect and axial thermal expansion. In this work, the normal operating Hot Full Power (HFP) state is the only power level of interest, so analyses focus on the PRD calculated from HZP to HFP. The PRD has been used to assess the reactor safety features asymptotically in unprotected accident scenarios, including the loss of heat sink (LOHS), loss of flow (LOF), and transient overpower (TOP) without scram. The PRD concept relies on the “global” reactivity coefficients A, B, and C that are estimated based on “individual” reactivity effects (Doppler, sodium density, etc.). The objectives of this work are: 1) to improve and verify the methodology used to calculate the ABC coefficients used in the PRD, 2) to assess if the PRD can be used to reliably identify abnormal events. This report fulfills the FY-2024 scope of WBS#1.15.8.3 activity, “ANL0120 – Predictive Analyses of PRD as function of deformation”. The PRD concept is described in Sections 2. Additional effort in refining the methodology for core bowing modeling is performed in Sections 3. Then, two verification exercises are proposed in Section 4 to benchmark these coefficients based on direct neutronic-only calculations and on dynamic core transient simulations. Finally, the PRD approach is assessed for the detection of several unexpected events, such as primary flow perturbation or improper fuel loading, in Section 5.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhancement of Distribution System State Estimation Using Pruned Physics-Aware Neural Networks: Preprint

Realizing complete observability in the three-phase distribution system remains a challenge that hinders the implementation of classical state estimation algorithms. In this paper, a new method so-called pruned physics-aware neural network (P2N2) is developed to improve the voltage estimation accuracy in the distribution system. The method relies on the physical grid topology, which is used to design the connections between different hidden layers of a neural network model. To verify the proposed method, a numerical simulation based on one-year smart meter data of load consumptions for threephase power flow is developed to generate the measurement and voltage state data. The IEEE 123 node system is selected as the test network to benchmark the proposed algorithm against the classical weighted least squares (WLS). Numerical results show that P2N2 outperforms WLS, in terms of data redundancy and estimation accuracy.

distribution systems state estimation↗

Experimental characterization of extreme temperature granular flows for solar thermal energy transport and storage

High-temperature, dense granular flows along an inclined plane were considered for solar thermal energy transport and storage with sintered bauxite particles. A series of experiments was performed for particle inlet temperatures of ~ 200, 400, 600, and 800 °C to understand the mechanisms of granular flows at extreme temperatures. Mass flow rates were measured using a load cell and free-surface velocities were measured and computed using particle image velocimetry. Surface temperatures were measured using infrared cameras. A significant decrease in steady-state particle mass flow rate was observed with increasing temperature due to changing flow properties. A decrease in bulk particle free-surface velocities was observed at higher temperatures. Free-surface velocity measurement error between experiments were within 20% of the average. The particle surface temperatures decreased from inlet to outlet with larger gradients at higher temperatures observed due to increasing convection and radiative heat losses. Here, a decrease in temperature was observed along the side walls due to a decrease in particle velocities.

14 SOLAR ENERGY↗