Grid Impacts of Hyperloop Technology in the United States

This report provides an overview of Hyperloop technologies including the current technology developments and a brief discussion on key components of the Hyperloop system that determine the electric power requirements as a function of time. At-scale Hyperloop systems do not exist yet so a model was used to generate a set of load profiles for conceptual systems at four locations in the United States: two in California, one in Colorado, and one in Ohio. In all four cases, the modeled Hyperloop load profiles showed a pulsating characteristic in both active and reactive power. Grid modeling was performed by Pacific Northwest National Laboratory to estimate the grid impacts and to discuss grid integration challenges. This report discusses the outcomes of the grid simulations for four study cases and offers some perspective of how existing large industrial loads with similar load characteristics are treated to accommodate current grid planning guidelines. The report concludes with a discussion on how energy storage system might be used to eliminate the pulsating load characteristics or significantly reduce it.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-scale experimental study of creep-fatigue failure initiation in a 709 Stainless Steel alloy using high resolution digital image correlation. Final report

This report discusses the efforts made towards the multi-scale study of the creep-fatigue response of stainless steel 709. Multiple experimental techniques, including digital image correlation (DIC) and electron backscatter diffraction (EBSD), were used in assessing the evolution of damage accumulation during fatigue, creep-fatigue, and thermomechanical fatigue of alloy 709. The role of microstructural features, hold times, temperature, and loading profiles were quantified and the interchangeability of temperature and time was investigated. Finally, a thermomechanical fatigue model was shown to predict well the failure of samples with varying loading profiles. Results indicate that strain accumulation in 709 steel happens primarily near grain boundaries (GBs) with the strains around GBs being inversely proportional to their measured residual burgers vector. Furthermore, hot-spots for strain accumulation were shown to be the locations of eventual microcrack nucleation. The introduction of hold times to the periodic loading cycle increases the damage accumulation rate and thus shortens the fatigue life of samples–this was true for both room temperature and high temperature. Thermomechanical cycling was shown to have little effect on the end life of samples, with the damage accumulation rate for in-phase and out-of-phase cycling being similar to isothermal fatigue. The interchangeability of time and temperature was shown to be possible within the studied load, time, and temperature ranges, since deformation mechanisms driving strain accumulation did not change with temperature (up to 650°C). The Neu-Sehitoglu thermomechanical fatigue model, with constants obtained from the literature and in part from our experimental results, was applied to predict failure of isothermal creep-fatigue samples. The main objectives of this work were to:(a) Perform high-resolution digital image correlation measurements (HiDIC) for alloy 709; (b) Quantify and assess damage accumulation at the microstructure under fatigue, TMF, and creep-fatigue conditions of 709; (c) Study of the role of hold times, i.e., adding a creep component, to: Room temperature cycling, High temperature cycling, Failure; (d) Study the mechanisms of thermomechanical fatigue in this alloy; (e) Investigate the existence of a time-temperature interchangeability criterion to aid in accelerated creep-fatigue testing; (f) Establish the validity of a combined creep-fatigue model for life prediction for 709. This report is structured with each subsequent section detailing the efforts, results, and conclusions related to each of the objectives described, mostly in chronological order.

36 MATERIALS SCIENCE↗

Modeling and Impact of Hyperloop Technology on the Electricity Grid

This paper provides an overview of hyperloop technologies, including a brief discussion of key components of a hyperloop system that determine the electric power requirements as a function of time. At-scale hyperloop systems do not yet exist, so a model was used to generate a set of load profiles for conceptual hyperloop realizations at four locations in the United States: two systems in California and one each in Colorado and Ohio. In all four cases, the modeled hyperloop load profiles included pulses in both active and reactive power. Grid modeling was performed to estimate the grid impacts and for dis-cussing grid integration challenges. The paper discusses how energy storage systems might be used to eliminate the pulsating load characteristics or significantly reduce it to accommodate current grid planning guidelines

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM's existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

batteries↗

Peak Power Reduction for HVAC Operations in Multi-unit Commercial Buildings

The load profiles of most commercial consumers are characterized by brief periods of very high power consumption followed by intervals of relatively lower demand. In order to flatten commercial load profiles, several power utilities in addition to billing energy consumption, levy a demand charge (DC) on the monthly peak demand. In this work, we consider the problem of joint optimization of energy costs (EC) and DC incurred by a multi-unit building which follows a demand response (DR) program. Despite the non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using linear programming. We evaluate the performance of the proposed power control scheme for various climate zones in the US. We show that depending on the ambient conditions and the prescribed tariff structure, our strategy can result in savings of up to nearly 19% compared to the baseline.

Raza Naqvi, Syed A.↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

The Building ENergy Demand (BEND) Model: A Comprehensive Composite Building Energy Modeling Framework

The Building ENergy Demand (BEND) model was developed at Pacific Northwest National Laboratory (PNNL) to simulate climate-dependent hourly building energy demand with the ability to disaggregate down to or aggregate up to any geographic area of interest, including counties, states, electric utility service territories, and census regions. The BEND modeling framework is designed to study the effects of climate change, economics, technology advancement, and various mitigation policies on aggregate building energy demand. To make the process computationally feasible, BEND reduces granularity in building characteristics and weather forcing while maintaining enough detail to minimize systematic differences (biases) between BEND results and data from the Energy Information Administration (EIA). Based on the Commercial Building Energy Consumption Survey (CBECS) and Residential Energy Consumption Survey (RECS) databases, BEND establishes a set of representative buildings with predefined sets of building types, sizes, and vintages. These representative buildings are defined for each of the four U.S. census regions and the five climate zones used by the EIA for building surveys (hereafter “EIA climate zones”). BEND’s representative buildings are based on a statistical analysis of the CBECS and RECS databases that infers detailed parameters such as construction type, thermal properties, internal loads, equipment and mechanical systems, and operation schedules from the high-level descriptors in those databases (building type, vintage, size, and location). The representative buildings are simplified and consolidated into a set of prototype buildings for the purpose of simulating building energy demand. Combining the prototype buildings with weather files from selected locations and years, BEND creates a set of simulation-ready building models to be run using the EnergyPlus simulation engine (EnergyPlus). The base spatial unit of each BEND simulation is a subregion that is the intersection of an International Energy Conservation Code climate zone, a census region, and an EIA climate zone; analysis for each spatial unit is influenced by the weather file BEND selects to represent the climate-similar area. The major simulation outputs of interest to BEND are hourly energy consumption values for each simulated year, possibly for multiple fuel types. Based on building-stock weights derived from the CBECS/RECS data, the hourly output streams are aggregated to a single, 8760-hour load profile for each of the major building categories—residential and commercial—with the possibility of segregating by fuel types. To correct for biases inherent in the use of a limited suite of representative buildings, BEND is calibrated against observational targets of total annual building energy consumption and hourly load profiles (including peak demand) obtained for the decision-relevant geographic scales of interest (e.g., total electric load data for individual balancing authorities available from EIA). Based on available data such as population distribution, BEND is able to aggregate both up and down scales, allowing the study of building energy demand over a range of spatial scales (e.g., states or counties within the Western Electricity Coordinating Council, Eastern Interconnection, or the entire U.S.) and/or subsets of building types (e.g., office buildings with particular size ranges).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bilevel Nodal Behind-the-meter Solar Disaggregation Under Unexpected Extreme Weather Conditions

As the power grid undergoes significant paradigm shift due to the increasing penetration of renewable generation, the ever-growing installation of behind-the-meter (BTM) solar generation in the power grid also has a significant impact on nodal loads, posing challenges on transmission operators. Furthermore, increasing frequent and severe extreme weather events intertwine with ubiquitous BTM solar generations and have amplified the challenges of accurately model nodal load profiles, especially under the lack of ground-truth information for verification. To tackle these challenges, this paper introduces a bilevel model that utilizes year-long data (e.g., proxy solar, zonal load, and individual node load profiles) to disaggregate metered profiles into actual demand and BTM solar generation at each transmission node. The proxy solar not only scales the BTM solar generation of individual nodes but also create a compensation term for enhancing performance on days with unexpected extreme weather events. The proposed algorithm is validated with real-world PJM Interconnection data during unexpected events like the recent Winter Storm Elliott. For quantitative evaluations, a novel Score error is introduced, which is based on mean percentages and load scales and offers a universal assessment method suitable for all nodes and different data formats (e.g., normalized or raw values).

behind-the-meter solar, load disaggregations, load↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

Modeling occupancy-driven building loads for large and diversified building stocks through the use of parametric schedules

Building energy modeling provides a fundamental tool to assess the potential for energy efficiency to contribute to reducing world energy consumption and global emissions. Occupancy-related operations are a key source of uncertainty for building energy analysis, particularly for aggregated building stocks. At a district or city level, it is critical to estimate aggregated power load profiles for sizing power grid infrastructure, power plant capacity allocation, and energy efficiency measures. The stochastic nature of behavior-related operations complicates the creation of models that accurately capture building load profiles for entire building stocks. This research introduces a new methodology called parametric schedules to model occupancy-driven schedules for large and diverse building stocks. In contrast to computationally expensive methodologies proposed in the literature, our work does not use a recursive time-consuming step. Occupancy is estimated by the extrapolation of operation times directly from metered electric consumption data; occupancy-related schedules are stochastically assigned to each building model, guaranteeing diversity of operation times in the stock. Our procedure has been tested on a large, diversified data-set of 25,000 commercial buildings in Los Angeles, California. It proved to be able to adequately represent the stochastic schedules diversity of the stock and to refine the stock calibration process by 1%. This innovative approach represents a useful asset for utility companies, grid operators, urban planners, and balancing authorities, seeking to improve building stock modeling and better estimate the impact of energy conservation measures. – This work is part of a larger stock modeling tool called ComStock, which is under development by NREL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar-plus-storage economics: What works where, and why?

This paper explores the economics of solar-plus-storage projects for commercial-scale, behind-the-meter applications. It provides insight into the near-term and future solar-plus-storage market opportunities across the U.S. We explore the impacts of location, building load profile, technology cost, utility rate structure, and policies on solar-plus-storage economic viability, and identify which factors are most significant to project economics. While savings from storage-only projects are largely derived from demand charge reductions, solar combined with storage also provides significant energy charge savings. A common assumption is that load profiles with peaks are likely candidates for savings from storage, due to the opportunity for demand charge reduction. Our results indicate that potential for savings from combining solar with storage is independent of building load variability, likely due to the energy cost reductions from the solar. Systems are more often economical under time of use and demand charge rates, particularly when demand charges are >$10 per kilowatt. Where systems were found to be economical, expected lifetime savings averaged between 7%-10%, with savings of 30% in numerous cases. Near term markets exist for solar-plus-storage in locations such as California and New York. As technology prices drop, the number of building types that can benefit increase, and additional markets appear in Colorado, New Mexico, and Alaska. All data from the study and interactive modeling results are available at: https://openei.org/wiki/Solar+Storage.

25 ENERGY STORAGE↗

Development of near-optimal advanced control sequences for chiller plants with water-side economizers in U.S. Climates (ASHRAE RP-1661)

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the evaluation and optimization of those controls is limited. It is possible to maximize energy savings by selecting different sequences and related parameters based on the plant configuration, load, and climate. This paper addresses this gap by developing near-optimal advanced control sequences for chiller plants with WSEs. First, advanced control sequences for chiller plants with WSEs are categorized into condenser water, chilled water, and hybrid controls and representative sequences from each category are identified. Next, 504 different scenarios are optimized. These scenarios represent all possible combinations of two plant configurations, a constant or variable load profile, three advanced control sequences, and seven optimization parameter combinations in six climate zones. The results show the recommended near-optimal sequences can reduce energy consumption by up to 15% relative to the baseline depending on the configuration, load profile, and climate. Specifically, the CW-CHW sequence is recommended for the majority of systems because it is often the most energy efficient and/or reduces the runtime of chillers. The methodology in this paper provides practical guidance for achieving energy savings through near-optimal control of chiller plants with WSEs.

42 ENGINEERING↗

Optimal Decentralized Protocol for Electric Vehicle Charging

We propose a decentralized algorithm to optimally schedule electric vehicle (EV) charging. The algorithm exploits the elasticity of electric vehicle loads to fill the valleys in electric load profiles. We first formulate the EV charging scheduling problem as an optimal control problem, whose objective is to impose a generalized notion of valley-filling, and study properties of optimal charging profiles. We then give a decentralized algorithm to iteratively solve the optimal control problem. In each iteration, EVs update their charging profiles according to the control signal broadcast by the utility company, and the utility company alters the control signal to guide their updates. The algorithm converges to optimal charging profiles (that are as "flat" as they can possibly be) irrespective of the specifications (e.g., maximum charging rate and deadline) of EVs, even if EVs do not necessarily update their charging profiles in every iteration, and use potentially outdated control signal when they update. Moreover, the algorithm only requires each EV solving its local problem, hence its implementation requires low computation capability. We also extend the algorithm to track a given load profile and to real-time implementation.

Gan, LW↗

GridPIQ Reference Data

GridPIQ uses dozens of publicly available datasets to provide context for a user's grid project, as well as defaults for users to choose from. Users can choose to import their own data to better customize their analysis or use GridPIQ-supplied defaults. This allows users to get up and running with an analysis very quickly without having to spend significant time pulling together input data. To run an electric vehicle (EV) smart charging project, a user will need to provide or select from prepopulated values for the regional load profile shape and peak load, region of interest and closest weather station, EV charging profile, number of EVs to add for the analysis, maximum EV charging power, location of chargers relative to grid infrastructure, and allowable charging times (for coordinated charging mode). The outputs of the analysis are changes in air quality, EV energy consumption, EV peak demand, and EV hourly consumption profile—before and after project implementation." For a detailed description of the tool methodology, including all the publicly available datasets used by the tool, see the [GridPIQ documentation](https://gridpiq.pnnl.gov/v2-beta/doc/).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W↗

Charge Management for an Inductively Charged On-Demand Battery-Electric Shuttle Service with High Penetration of Renewable Energy

This paper presents a charge management control strategy for an on-demand battery-electric shuttle van operating at the National Renewable Energy Laboratory (NREL) campus and supported by day-time inductive charging at the vehicle's waiting spot. A new control algorithm has been proposed for reducing the demand charge costs incurred from wireless charging of the on-demand shuttle. A custom controller has been developed to monitor the shuttle, wireless charger, renewable energy generation, and various loads at NREL's campus, and regulate charging behavior for demand response. The intermittent renewable generation and sporadic operation of the on-demand shuttle service contribute to a high level of uncertainty in expected campus load profile, which must be carefully managed. The control algorithm predicts energy profile to estimate the mobility needs of the vehicle and maintain uninterrupted service during operation while still minimizing peak demand. The proposed controller has been designed and optimized using a Simulink model for the entire system. Next, it has been implemented and tested in real-time on the NREL campus. Two primary vehicle-use cases, charge sustaining and charge depletion operation, are tested under different load profiles and drive cycles to assess the controller's effectiveness at reducing peak demand and therefore demand charges. The proposed controller showed robust performance under different driving scenarios with high correlation between simulated and experimental data. The results showed that proper demand response can be achieved with an average of 94% reduction of charging loads during peak demand events.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Improving the economics of battery storage for industrial customers: Are incentives enough to increase adoption?

As adoption of behind-the-meter battery energy storage increases across the United States, implementation continues to lag in the industrial sector. This analysis considers two manufacturing facilities with potential for load shifting to reduce peak demand. Although both facilities have load profiles that demonstrate great potential for regular and programmed demand reduction during peak hours, battery energy storage was deemed prohibitively expensive. A review of several existing utility and state-level policies and incentives determined that few may be rightsized for the industrial customer class. Furthermore, this analysis further considers multiple incentive structures and finds that although incentives increase viability of energy storage, developers must also consider optimization, unique load profiles, and use case to effectively increase adoption of battery energy storage by industrial customers.

25 ENERGY STORAGE↗

Grid Integration of Aggregated Demand Response, Part 1: Load Availability Profiles and Constraints for the Western Interconnection

Demand response (DR) has the potential to improve electric grid reliability and reduce system operation costs. However, including DR in grid modeling can be difficult due to its variable and non-traditional response characteristics, compared to traditional generation. Therefore, efforts to value the participation of DR in procurement of grid services have been limited. In this report, we present methods and tools for predicting demand response availability profiles, representing their capability to participate in capacity, energy, and ancillary services. With the addition of response characteristics mimicking those of generation, the resulting profiles will help in the valuation of the participation of demand response through production cost modeling, which informs infrastructure and investment planning.