Multiscale Effects Masked the Impact of the COVID-19 Pandemic on Electricity Demand in the United States

Shelter-in-place orders and business closures related to COVID-19 changed the hourly profile of electricity demand and created an unprecedented source of uncertainty for the grid. The potential for continued shifts in electricity profiles has implications for electricity sector investment and operating decisions that maintain reserve margins and provide grid reliability. This study reveals that understanding this uncertainty requires an understanding of the underlying drivers at the customer-class scale. This paper utilizes three datasets to compare the impacts of COVID-19 on electricity consumption across a range of spatiotemporal and customer scales. At the utility/customer-class scale, COVID-19-induced shutdowns in the spring of 2020 shifted weekday residential load profiles to resemble weekend profiles from previous years. Total commercial loads declined, but the commercial diurnal load profile was unchanged. With only total loads available at the balancing authority scale, the apparent impact of COVID-19 was smaller during the summer due in part to phased re-opening and spatial variability in re-opening, but there were still clear variations once total loads were broken down zonally. Monthly data at the state scale showed an increase in state-level residential electricity sales, a decrease in commercial sales, and a small net decrease in total sales in most states from April-August 2020. Analyses that focus on total load or a single scale may miss important changes that become apparent when the load is broken down regionally or by customer class.

COVID-19, electricity demand, multiscale, Commonwe↗

A Short-Term and High-Resolution System Load Forecasting Approach Using Support Vector Regression with Hybrid Parameters Optimization

This work proposes an approach for distribution system load forecasting, which aims to provide highly accurate short-term load forecasting with high resolution utilizing a support vector regression (SVR) based forecaster and a two-step hybrid parameters optimization method. Specifically, because the load profiles in distribution systems contain abrupt deviations, a data normalization is designed as the pretreatment for the collected historical load data. Then an SVR model is trained by the load data to forecast the future load. For better performance of SVR, a two-step hybrid optimization algorithm is proposed to determine the best parameters. In the first step of the hybrid optimization algorithm, a designed grid traverse algorithm (GTA) is used to narrow the parameters searching area from a global to local space. In the second step, based on the result of the GTA, particle swarm optimization (PSO) is used to determine the best parameters in the local parameter space. After the best parameters are determined, the SVR model is used to forecast the short-term load deviation in the distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Puerto Rico Demand Response Impact and Forecast Tool (PR-DRIFT) - Beta Version [Slides]

Due to high fossil fuel imports, high electricity rates, an unreliable electricity grid, and 100% renewable electricity goals, demand response can play a crucial role for the Puerto Rico electricity grid. The Puerto Rico Demand Response Impact and Forecast Tool (PR-DRIFT) is a spreadsheet-based tool in which users can estimate the potential impacts of demand response, energy efficiency, and VRE and storage adoption in Puerto Rico from 2021 through 2040. The tool includes projections for solar, wind, and battery adoption based on released RFPs and energy targets (including Act-17 2019) to generate a projected net load profile for each hour through 2040. Based on user inputs and default assumptions, the tool also projects load profile impacts of demand response and energy efficiency, and is specifically focused on highlighting projected demand response technical potential. This demand response technical potential can be used by local utilities, regulators, program administrators, or researchers to help design demand response programs for larger impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intelligent load pattern modeling and denoising using improved variational mode decomposition for various calendar periods

This paper proposes a novel approach to identify the load patterns considering calendar impact and denoising process, which advances the state of art of load identification and load forecasting to a more flexible and adaptive extent by revealing the correlation between load profile and the substantial influence factors. With the rapid development and the promising application of energy intemet and grid modernization, the accurate load modeling and forecasting especially by load pattern modeling (LPM) have become more and more critical to observe and estimate load profile so as to optimize the operation efficiency of the power grid. Traditional methods mostly focus on the static LPM itself which are unable to account the non-linear and highly dynamic load fluctuations in order to balance the demand of the power grid during various calendar period (VCP) scheduling. In this paper, a load pattern modeling method for power grid considering the impact of typical calendar effects is proposed using a combination of improved variational mode decomposition (IVMD) and deep belief network (DBN) algorithm. Firstly, an index of load curve curvature (LCC) is proposed to improve the selection of value K in the conventional VMD algorithm. The value K of the intrinsic modality is determined by adopting LCC to better quantify the average instantaneous frequency of the modal decomposition of the VMD and to reduce the elevated stochasticity of k. Secondly, an optimization formulation is developed based on adaptive segmented loop decomposition of the typical correlation coefficient to suppress the edge effect in VMD decomposition, which would enable the reconstructed curve to incorporate the variabilities from the initial data. Finally, the IVMD and DBN algorithms are jointly implemented to optimize the accuracy of VCP load pattern modeling curve regression. Numerical examples have been performed with the results proving that the proposed method significantly outperforms the state-of-art in reducing the modeling error of VCP load curve, improving the overall forecasting accuracy, and reducing load dispatching cost.

deep belief network↗

Supervisory Control of Loads and Energy Storage in Next-Generation Zero Energy Buildings

A zero energy building (ZEB)—also known as a net zero energy or zero net energy building—is a building that exports as much renewable energy as the total energy it imports from other sources on an annual basis (DOE 2015). Large-scale and commercially viable ZEBs are now in the marketplace, and they are expected to become a larger share of the commercial building footprint as government and private sector policies continue to promote the development of buildings that produce more on-site energy than they use. However, the load profiles of ZEBs are currently perceived by electric utilities to be unfavorable and unpredictable. As shown in Figure ES-1, ZEB load profiles can have abrupt changes in magnitude, at times switching rapidly between exporting and importing electricity. This is a challenge for utilities, which are responsible for constantly balancing electricity supply and demand across the grid. Addressing these concerns will require new strategies and tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid Impacts of Hyperloop Technology in the United States

This report provides an overview of Hyperloop technologies including the current technology developments and a brief discussion on key components of the Hyperloop system that determine the electric power requirements as a function of time. At-scale Hyperloop systems do not exist yet so a model was used to generate a set of load profiles for conceptual systems at four locations in the United States: two in California, one in Colorado, and one in Ohio. In all four cases, the modeled Hyperloop load profiles showed a pulsating characteristic in both active and reactive power. Grid modeling was performed by Pacific Northwest National Laboratory to estimate the grid impacts and to discuss grid integration challenges. This report discusses the outcomes of the grid simulations for four study cases and offers some perspective of how existing large industrial loads with similar load characteristics are treated to accommodate current grid planning guidelines. The report concludes with a discussion on how energy storage system might be used to eliminate the pulsating load characteristics or significantly reduce it.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-scale experimental study of creep-fatigue failure initiation in a 709 Stainless Steel alloy using high resolution digital image correlation. Final report

This report discusses the efforts made towards the multi-scale study of the creep-fatigue response of stainless steel 709. Multiple experimental techniques, including digital image correlation (DIC) and electron backscatter diffraction (EBSD), were used in assessing the evolution of damage accumulation during fatigue, creep-fatigue, and thermomechanical fatigue of alloy 709. The role of microstructural features, hold times, temperature, and loading profiles were quantified and the interchangeability of temperature and time was investigated. Finally, a thermomechanical fatigue model was shown to predict well the failure of samples with varying loading profiles. Results indicate that strain accumulation in 709 steel happens primarily near grain boundaries (GBs) with the strains around GBs being inversely proportional to their measured residual burgers vector. Furthermore, hot-spots for strain accumulation were shown to be the locations of eventual microcrack nucleation. The introduction of hold times to the periodic loading cycle increases the damage accumulation rate and thus shortens the fatigue life of samples–this was true for both room temperature and high temperature. Thermomechanical cycling was shown to have little effect on the end life of samples, with the damage accumulation rate for in-phase and out-of-phase cycling being similar to isothermal fatigue. The interchangeability of time and temperature was shown to be possible within the studied load, time, and temperature ranges, since deformation mechanisms driving strain accumulation did not change with temperature (up to 650°C). The Neu-Sehitoglu thermomechanical fatigue model, with constants obtained from the literature and in part from our experimental results, was applied to predict failure of isothermal creep-fatigue samples. The main objectives of this work were to:(a) Perform high-resolution digital image correlation measurements (HiDIC) for alloy 709; (b) Quantify and assess damage accumulation at the microstructure under fatigue, TMF, and creep-fatigue conditions of 709; (c) Study of the role of hold times, i.e., adding a creep component, to: Room temperature cycling, High temperature cycling, Failure; (d) Study the mechanisms of thermomechanical fatigue in this alloy; (e) Investigate the existence of a time-temperature interchangeability criterion to aid in accelerated creep-fatigue testing; (f) Establish the validity of a combined creep-fatigue model for life prediction for 709. This report is structured with each subsequent section detailing the efforts, results, and conclusions related to each of the objectives described, mostly in chronological order.

36 MATERIALS SCIENCE↗

Modeling and Impact of Hyperloop Technology on the Electricity Grid

This paper provides an overview of hyperloop technologies, including a brief discussion of key components of a hyperloop system that determine the electric power requirements as a function of time. At-scale hyperloop systems do not yet exist, so a model was used to generate a set of load profiles for conceptual hyperloop realizations at four locations in the United States: two systems in California and one each in Colorado and Ohio. In all four cases, the modeled hyperloop load profiles included pulses in both active and reactive power. Grid modeling was performed to estimate the grid impacts and for dis-cussing grid integration challenges. The paper discusses how energy storage systems might be used to eliminate the pulsating load characteristics or significantly reduce it to accommodate current grid planning guidelines

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM's existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

batteries↗

Peak Power Reduction for HVAC Operations in Multi-unit Commercial Buildings

The load profiles of most commercial consumers are characterized by brief periods of very high power consumption followed by intervals of relatively lower demand. In order to flatten commercial load profiles, several power utilities in addition to billing energy consumption, levy a demand charge (DC) on the monthly peak demand. In this work, we consider the problem of joint optimization of energy costs (EC) and DC incurred by a multi-unit building which follows a demand response (DR) program. Despite the non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using linear programming. We evaluate the performance of the proposed power control scheme for various climate zones in the US. We show that depending on the ambient conditions and the prescribed tariff structure, our strategy can result in savings of up to nearly 19% compared to the baseline.

Raza Naqvi, Syed A.↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

The Building ENergy Demand (BEND) Model: A Comprehensive Composite Building Energy Modeling Framework

The Building ENergy Demand (BEND) model was developed at Pacific Northwest National Laboratory (PNNL) to simulate climate-dependent hourly building energy demand with the ability to disaggregate down to or aggregate up to any geographic area of interest, including counties, states, electric utility service territories, and census regions. The BEND modeling framework is designed to study the effects of climate change, economics, technology advancement, and various mitigation policies on aggregate building energy demand. To make the process computationally feasible, BEND reduces granularity in building characteristics and weather forcing while maintaining enough detail to minimize systematic differences (biases) between BEND results and data from the Energy Information Administration (EIA). Based on the Commercial Building Energy Consumption Survey (CBECS) and Residential Energy Consumption Survey (RECS) databases, BEND establishes a set of representative buildings with predefined sets of building types, sizes, and vintages. These representative buildings are defined for each of the four U.S. census regions and the five climate zones used by the EIA for building surveys (hereafter “EIA climate zones”). BEND’s representative buildings are based on a statistical analysis of the CBECS and RECS databases that infers detailed parameters such as construction type, thermal properties, internal loads, equipment and mechanical systems, and operation schedules from the high-level descriptors in those databases (building type, vintage, size, and location). The representative buildings are simplified and consolidated into a set of prototype buildings for the purpose of simulating building energy demand. Combining the prototype buildings with weather files from selected locations and years, BEND creates a set of simulation-ready building models to be run using the EnergyPlus simulation engine (EnergyPlus). The base spatial unit of each BEND simulation is a subregion that is the intersection of an International Energy Conservation Code climate zone, a census region, and an EIA climate zone; analysis for each spatial unit is influenced by the weather file BEND selects to represent the climate-similar area. The major simulation outputs of interest to BEND are hourly energy consumption values for each simulated year, possibly for multiple fuel types. Based on building-stock weights derived from the CBECS/RECS data, the hourly output streams are aggregated to a single, 8760-hour load profile for each of the major building categories—residential and commercial—with the possibility of segregating by fuel types. To correct for biases inherent in the use of a limited suite of representative buildings, BEND is calibrated against observational targets of total annual building energy consumption and hourly load profiles (including peak demand) obtained for the decision-relevant geographic scales of interest (e.g., total electric load data for individual balancing authorities available from EIA). Based on available data such as population distribution, BEND is able to aggregate both up and down scales, allowing the study of building energy demand over a range of spatial scales (e.g., states or counties within the Western Electricity Coordinating Council, Eastern Interconnection, or the entire U.S.) and/or subsets of building types (e.g., office buildings with particular size ranges).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bilevel Nodal Behind-the-meter Solar Disaggregation Under Unexpected Extreme Weather Conditions

As the power grid undergoes significant paradigm shift due to the increasing penetration of renewable generation, the ever-growing installation of behind-the-meter (BTM) solar generation in the power grid also has a significant impact on nodal loads, posing challenges on transmission operators. Furthermore, increasing frequent and severe extreme weather events intertwine with ubiquitous BTM solar generations and have amplified the challenges of accurately model nodal load profiles, especially under the lack of ground-truth information for verification. To tackle these challenges, this paper introduces a bilevel model that utilizes year-long data (e.g., proxy solar, zonal load, and individual node load profiles) to disaggregate metered profiles into actual demand and BTM solar generation at each transmission node. The proxy solar not only scales the BTM solar generation of individual nodes but also create a compensation term for enhancing performance on days with unexpected extreme weather events. The proposed algorithm is validated with real-world PJM Interconnection data during unexpected events like the recent Winter Storm Elliott. For quantitative evaluations, a novel Score error is introduced, which is based on mean percentages and load scales and offers a universal assessment method suitable for all nodes and different data formats (e.g., normalized or raw values).

behind-the-meter solar, load disaggregations, load↗

The value of integrating a geothermal district heating system into a microgrid

As electrical grids increasingly rely on variable renewable energy, maintaining reliability and cost efficiency becomes more complex. To address these challenges, this study analyzed the integration of geothermal district heating as a grid-responsive thermal resource within a microgrid in Tuttle, Oklahoma. Building energy modeling using EnergyPlus estimated annual district heating demand at 2.9 GWh, with a peak load of 2.8 MW th . Techno-economic analyses were conducted to meet the heating demand under three geothermal scenarios, varying by production depth, flow rate, and thermal output, each supplemented by natural gas peaking boilers. In parallel, equivalent electrical load profiles were developed using typical coefficients of performance (COPs) for air-source heat pumps and electric boilers to establish an electrified baseline scenario. A complete end-use electrical load profile was also developed for the microgrid using Cambium dataset. The modeling results demonstrated reliable and economic operation of the geothermal systems over 30 years, with COPs ranging from 2.6 to 8.9 and the lowest levelized heating cost at $\$$54.6/MWh. Geothermal integration reduced electricity consumption by up to 94.7 % compared to the non-geothermal base case, yielding annual energy savings of up to $\$$803 k. Avoided grid costs ranged from $\$$65 k–$\$$147 k per year, with individual events avoiding up to $\$$4,863 per hour. Grid-responsive operation further reduced wholesale energy costs by 53–56 %. These findings demonstrate geothermal heating, traditionally treated as a non-grid-responsive thermal resource, can be reconfigured to support dynamic grid services, offering a scalable pathway to enhance reliability and reduce costs in renewable-rich microgrids and district heating networks.

15 GEOTHERMAL ENERGY↗

Modeling occupancy-driven building loads for large and diversified building stocks through the use of parametric schedules

Building energy modeling provides a fundamental tool to assess the potential for energy efficiency to contribute to reducing world energy consumption and global emissions. Occupancy-related operations are a key source of uncertainty for building energy analysis, particularly for aggregated building stocks. At a district or city level, it is critical to estimate aggregated power load profiles for sizing power grid infrastructure, power plant capacity allocation, and energy efficiency measures. The stochastic nature of behavior-related operations complicates the creation of models that accurately capture building load profiles for entire building stocks. This research introduces a new methodology called parametric schedules to model occupancy-driven schedules for large and diverse building stocks. In contrast to computationally expensive methodologies proposed in the literature, our work does not use a recursive time-consuming step. Occupancy is estimated by the extrapolation of operation times directly from metered electric consumption data; occupancy-related schedules are stochastically assigned to each building model, guaranteeing diversity of operation times in the stock. Our procedure has been tested on a large, diversified data-set of 25,000 commercial buildings in Los Angeles, California. It proved to be able to adequately represent the stochastic schedules diversity of the stock and to refine the stock calibration process by 1%. This innovative approach represents a useful asset for utility companies, grid operators, urban planners, and balancing authorities, seeking to improve building stock modeling and better estimate the impact of energy conservation measures. – This work is part of a larger stock modeling tool called ComStock, which is under development by NREL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar-plus-storage economics: What works where, and why?

This paper explores the economics of solar-plus-storage projects for commercial-scale, behind-the-meter applications. It provides insight into the near-term and future solar-plus-storage market opportunities across the U.S. We explore the impacts of location, building load profile, technology cost, utility rate structure, and policies on solar-plus-storage economic viability, and identify which factors are most significant to project economics. While savings from storage-only projects are largely derived from demand charge reductions, solar combined with storage also provides significant energy charge savings. A common assumption is that load profiles with peaks are likely candidates for savings from storage, due to the opportunity for demand charge reduction. Our results indicate that potential for savings from combining solar with storage is independent of building load variability, likely due to the energy cost reductions from the solar. Systems are more often economical under time of use and demand charge rates, particularly when demand charges are >$10 per kilowatt. Where systems were found to be economical, expected lifetime savings averaged between 7%-10%, with savings of 30% in numerous cases. Near term markets exist for solar-plus-storage in locations such as California and New York. As technology prices drop, the number of building types that can benefit increase, and additional markets appear in Colorado, New Mexico, and Alaska. All data from the study and interactive modeling results are available at: https://openei.org/wiki/Solar+Storage.

25 ENERGY STORAGE↗

Development of near-optimal advanced control sequences for chiller plants with water-side economizers in U.S. Climates (ASHRAE RP-1661)

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the evaluation and optimization of those controls is limited. It is possible to maximize energy savings by selecting different sequences and related parameters based on the plant configuration, load, and climate. This paper addresses this gap by developing near-optimal advanced control sequences for chiller plants with WSEs. First, advanced control sequences for chiller plants with WSEs are categorized into condenser water, chilled water, and hybrid controls and representative sequences from each category are identified. Next, 504 different scenarios are optimized. These scenarios represent all possible combinations of two plant configurations, a constant or variable load profile, three advanced control sequences, and seven optimization parameter combinations in six climate zones. The results show the recommended near-optimal sequences can reduce energy consumption by up to 15% relative to the baseline depending on the configuration, load profile, and climate. Specifically, the CW-CHW sequence is recommended for the majority of systems because it is often the most energy efficient and/or reduces the runtime of chillers. The methodology in this paper provides practical guidance for achieving energy savings through near-optimal control of chiller plants with WSEs.