Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Leak Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Artificial Intelligence Thermostat to Detect Faults

Residential air conditioners and heat pumps often experience faults due to inadequate maintenance, which can severely reduce efficiency or even cause system failure. Common issues include dirty or clogged air filters and refrigerant leaks. These problems degrade performance and increase energy use and operating costs. This study presents a smart thermostat with embedded artificial intelligence to detect such faults and alert homeowners when maintenance is needed. The thermostat uses low-cost measurements—including return-air temperature, relative humidity, supply-air temperature, outdoor-air temperature, and condenser subcooling—to identify abnormal operations. Because different faults produce distinct response patterns, tailored algorithms are developed to recognize characteristic fault signatures. The investigation is built on a detailed co-simulation platform that couples EnergyPlus with the DOE/ORNL Heat Pump Design Model (HPDM). EnergyPlus represents the building’s dynamic environment, while HPDM is a high-fidelity, hardware-based model that can simulate fault-free performance as well as a wide range of faults, including gradual degradation such as minor refrigerant leakage. This platform provides a virtual training and testing environment that helps distinguish fault-induced behavior from normal operation and supports development of robust diagnostic algorithms. Using this framework, a Dynamic Bayesian Network was developed to identify two common faults—gradual refrigerant charge loss and indoor airflow blockage—and the AI-embedded thermostat was verified through annual building simulations.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Seismic H2: Version 1.0

Seismic-H2 is an integrated software package for geological hydrogen reservoir simulation, optimization, and leakage monitoring. The package includes multiple components: (1) code used for modeling seismic wave propagation in 3D heterogeneous elastic media based on finite-difference method to support detection of geological hydrogen storage reservoir leakage; (2) 3D reservoir simulations of leaks from an underground reservoir and 3D simulations of saline aquifers and depleted gas reservoirs; (3) seismic monitoring costs of passive and active seismic monitoring required for UHS; (4) rock physics calculations and interpolations for converting the reservoir simulations from part (2) into the elastic media models in part (1); (5) pre-processing seismic data; and lastly (6), a GUI interface that combines these different components.

Creasy, Neala↗

Normal or abnormal? Machine learning for the leakage detection in carbon sequestration projects using pressure field data

The international commitments for atmospheric carbon reduction will require a rapid increase in carbon capture and storage (CCS) projects. The key to any successful CCS project lies in the long term storage and prevention of leakage of stored carbon dioxide (CO 2 ). In addition to being a greenhouse gas, CO 2 leaks reaching the surface can accumulate in low-lying areas resulting in a serious health risk. Among several alternatives, some of the more promising CCS storage formations are depleted oil and gas reservoirs, where the reservoirs had good geological seals prior to hydrocarbon extraction. With more CCS wells coming online, it is imperative to implement permanent, automated monitoring tools. We apply machine learning models to automate the leakage detection process in carbon storage reservoirs using rates of (CO 2 ) injection and pressure data measured by simple harmonic pulse testing (HPT). To validate the feasibility of this machine learning based workflow, we use data from HPT experiments carried out in the Cranfield oil field, Mississippi, USA. The data consist of a series of pulse tests conducted with baseline parameters and with an artificially introduced leak. Here, in this study, we pose the leakage detection task as an anomaly detection problem where deviation from the predicted behavior indicates leaks in the reservoir. Results show that different machine learning architectures such as multi-layer feed forward network, Long Short-Term Memory, and convolutional neural network are able to identify leakages and can provide early warning. These warnings can then be used to take remedial measures.

58 GEOSCIENCES↗

Hydrogen Equipment Enclosure Risk Reduction through Earlier Detection of Component Failures

Hydrogen component reliability and the hazard associated with failure rates is a critical area of research for the successful implementation and growth of hydrogen technology across the globe. The research team has partnered to quantify system risk reduction through earlier detection of hydrogen component failures. A model of hydrogen dispersion in a hydrogen equipment enclosure has been developed utilizing experimentally quantified hydrogen component leak rates as inputs. This model provides insight into the impact of hydrogen safety sensors and ventilation on the flammable mass within a hydrogen equipment enclosure. This model also demonstrates the change in safety sensor response time due to detector placement under various leak scenarios. The team looks to improve overall hydrogen system safety through an improved understanding of hydrogen component reliability and risk mitigation methods. This collaboration fits under the work program of IEA Hydrogen Task 43 Subtask E Hydrogen System Safety.

CFD↗

Mini-cell: Compact all optical gas monitoring sensor for persistent surveillance of complex system

Persistent surveillance of complex systems by embedded sensing is the new paradigm of aging awareness and monitoring. In any complex system with a long-term lifespan plan, the persistent surveillance of critical parameters warrants the reliability and safety/security of the system by the continuous monitoring of the state of health and aging conditions. Therefore, embedded sensors of physical, chemical, and structural features/traits are critical for uncovering occurrences of undesired/unexpected events. Gas sensing can provide early detection of a broad range of problems such as decomposing components, corrosion, failures, and leaks. For the application of interest, the sensors must be: 1/highly selective and sensitive for a broad range of gas molecules, 2/compact, 3/minimally invasive, 4/rugged for vibration and thermal excursions, and 5/ environmentally inert.

47 OTHER INSTRUMENTATION↗

Lyman continuum leakage from low-mass galaxies with M ⋆ < 108 M⊙

ABSTRACT We present observations with the Cosmic Origins Spectrograph onboard the Hubble Space Telescope of nine low-mass star-forming galaxies at redshifts, z, in the range 0.3179–0.4524, with stellar masses $M_\star \, \lt $ 108 M⊙ and very high specific star-formation rates sSFR ∼150–630 Gyr−1, aiming to study the dependence of leaking Lyman continuum (LyC) emission on stellar mass and some other characteristics of the galaxy. We detect LyC emission in four out of nine galaxies with escape fractions, fesc(LyC), in the range of 11–35 per cent, and establish upper limits for fesc(LyC) in the remaining five galaxies. We observe a narrow Ly α emission line with two peaks in seven galaxies and likely more complex Ly α profiles in the two remaining galaxies. The velocity separation between the peaks Vsep varies in the range from ∼229 to ∼512 km s−1. Our additional data on low-mass galaxies confirm and strengthen the tight anticorrelation between fesc(LyC) and Vsep found for previous low-redshift galaxy samples with higher stellar masses. Vsep remains the best indirect indicator of LyC leakage. It is better than O32 on which fesc(LyC) depends weakly, with a large scatter. Finally, contrary to expectations, we find no increase of fesc(LyC) with decreasing galaxy stellar mass M⋆.

Izotov, Y. I.↗

Assessment of Cold Spraying Mild-Steel Powder onto Mild-Steel Substrate for Development of Waste Tank Repair System - 20515

Infrastructure for nuclear waste storage and processing (e.g., waste tanks, transfer pipelines, evaporators) at the U.S. Department of Energy (DOE) Hanford Site has been in service well beyond its original design life. Past corrosion control methods at Hanford for waste tanks have not been fully successful, as evidenced by leaks forming in tank AY-102, the first double-shell tank (DST) constructed, and significant degradation detected in the primary tanks of AP-102 and AY-101. Failure of infrastructure components can pose a significant risk to the environment, worker safety, and project schedules. Therefore, remotely deployable methods for repairing and extending the service life of the existing tank waste infrastructure are needed. Cold spray has been identified as a potential technique for performing in situ repairs and material buildup for life extension of waste storage and processing infrastructure. Cold-spray repair methods and technology are well-established and are used extensively by industry and the military for making repairs using dissimilar materials. Pacific Northwest National Laboratory is evaluating the process of making repairs using mild-steel powder applied to a mild-steel substrate to minimize the galvanic corrosion potential. This paper presents the initial results for a feasibility ('go/no-go') assessment as to whether low-density deposits with sound metallurgic bonds, to build-back steel plate material, can be achieved using existing commercial cold-spray equipment. An assessment of steel-on-steel deposit is necessary to determine if cold spray is a viable candidate for DST carbon steel plate restoration/repair and thus DST service life extension. Powder properties and preparation requirements have been investigated and operating conditions and parameters for depositing a cold-spray buildup of mild steel on a mild-steel substrate have been determined. Soundness of metallurgic bonding as a function of the operating parameters exercised and results from applying cold spray to lay a deposit over simulated small-diameter flaws in 1/2-inch mild-steel plate are presented. Application of in situ cold-spray repair to the DOE complex has the potential to reduce cost and schedule impacts associated with component failures and the need to procure and construct replacement infrastructure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Methodological Overview of Seismic Analysis for Nuclear Event Detection

Underground explosions generate potentially detectable signatures, including energy waves that travel through the Earth’s subsurface (i.e., seismic waves), low-frequency sound waves (i.e., infrasound and hydroacoustic waves), and radioactive gases and/or particles that might leak from the test cavity (if the event was nuclear). There can also be intelligence indicators of a test, such as observations of modified patterns of life and activity at a suspected test site. If all of these detectable signatures and intelligence indicators are present and self-consistent, then analysts have high confidence in classifying a signature generating event as an explosion. However, because only partial information about an event is likely to be available, determining whether an event was natural (e.g., an earthquake or landslide) or manmade (e.g., a chemical or nuclear explosion) is much more challenging. This primer describes how one category of event signatures—seismic signatures—can augment event analyses. While universities and government organizations have generated detailed technical descriptions of seismic analytic techniques, we seek to translate seismic event analysis for a broad, non-technical audience. When the geologic conditions near an event are well-characterized, seismic data can be used to calculate critical information, such as event location and depth, with relatively high accuracy. Moreover, specific features within seismic datasets can help determine whether an event was an explosion. However, a key challenge in seismic analysis is that geologic site conditions are often poorly characterized, complicating the ability to discern the true nature of the event. To overcome this challenge, geologists answer a series of questions (discussed in section 1) to guide seismic event analysis and determine the most probable nature of an event. As more information is gathered during each analytic step, confidence grows regarding the nature of the event. Section 2 addresses uncertainties in seismic analysis and the vital nature of high-fidelity geologic data for accurate seismic event analysis.

58 GEOSCIENCES↗

CsPbBr3 perovskite detectors with 1.4% energy resolution for high-energy γ-rays

Halide perovskite semiconductors are poised to revitalize the field of ionizing radiation detection as they have done to solar photovoltaics. We show that all-inorganic perovskite CsPbBr 3 devices resolve 137 Cs 662-keV γ-rays with 1.4% energy resolution, as well as other X- and γ-rays with energies ranging from tens of keV to over 1 MeV in ambipolar sensing and unipolar hole-only sensing modes with crystal volumes of 6.65 mm 3 and 297 mm 3 , respectively. Furthermore, we report the scale-up of CsPbBr 3 ingots to up to 1.5 inches in diameter with an excellent hole mobility–lifetime product of 8 × 10 -3 cm 2 V -1 and a long hole lifetime of up to 296 μs. CsPbBr 3 detectors demonstrate a wide temperature region from ~2 °C to ~70 °C for stable operation. Detectors protected with suitable encapsulants show a uniform response for over 18 months. Consequently, we identify perovskite CsPbBr 3 semiconductor as an exceptional candidate for new-generation high-energy γ-ray detection.

47 OTHER INSTRUMENTATION↗

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Control And Optimization Modular Modeling Application For Nuclear Deployment

The purpose of the COMMAND code is to provide a flexible, scalable tool for use in developing, integrating, and testing the technologies necessary for achieving autonomous operations of advanced nuclear reactors. The code enables users to efficiently implement custom simulations and experiments by combining key methods from different software modules. These modules are focused on: modeling and simulation tools, such as nuclear simulation tools used for high-fidelity modeling (e.g., Reactor Excursion and Leak Analysis Program [RELAP5-3D] and Monte Carlo N-Particle [MCNP]); machine learning and optimization tools (e.g., anomaly detection and data-driven modeling techniques); advanced control in its digital, high-performance, and supervisory control forms (e.g., proportional integral derivative (PID) control and model predictive control (MPC); and integration with hardware through industrial communication protocols. To ensure flexibility and scalability, COMMAND was designed to be both modular—the software “pieces” all inherit from generic building blocks and can be combined and connected to create complicated simulations—and high performing—designed for parallel processing, enabling simulations and experiments to take advantage of multi-core computers, servers, and nodes. The code is written in the Python programming language due to the language's popularity, active community, and open-source and cross-platform nature. Maintaining consistency with other simulation tools used within the nuclear energy community, users implement simulations and experiments through text input files, which define components, parameters, connections, etc., through lines of text. Given that COMMAND is written in Python, these input files are native Python scripts, and so use the standard Python structure and formatting. This also enables users to take advantage of Python's extensive package library to develop custom capabilities for their specific use cases.

Faber, Jacob [Idaho National Laboratory (INL), Ida↗

Fiber optic system for direct detection of CO 2 leakage in carbon storage wells (Abbreviated Final Report)

The feasibility study focused on the development of new fiber for distributed chemical sensing that will allow direct detection of CO2 leakages in the environment. This is particularly important for monitoring well integrity for carbon capture and storage (CSS), which can provide early warning for an incoming well failure and potential CO2 leaking through it. We proposed Raman or IR interrogation within gas-filled Holey Fibers (HoFs) interleaved with Fiber Bragg Grating (FBG) sections, so that the location and concentration of the gases would be provided simultaneously. The methodology would overcome current roadblocks to using fiber optics for CO2 (and other gases) detection in wells with direct in-situ measurements of concentration along with other important parameters such as temperature and pressure. We were able to assess commercially available IR/Raman hollow core fiber and demonstrated detection of CO2 through them in our controlled environment setups at various pressure conditions. We have also established the ability of drilling precisely with fs-lases side holes to enable penetration of CO2 into the hollow core fiber and reduce diffusion rates. Open joint collars were also explored with double functionality: to obtain splice to solid core fiber critical for field deployment and create gas ingress locations. Both diffusion-only and pressurized fiber system have been constructed following COMSOL based semi-hybrid optical /fluidodynamics models. FBGs have been identified and procured and characterized. Along the work we leveraged internal modeling/design, photonics/laser characterization, optical fiber fabrication, and AM lab capabilities to design, develop and test in-house components or assemblies. Our results indicate the potential of HoF for CO2 downhole direct detection.

25 ENERGY STORAGE↗

Ultrafast Early Warning of Heart Attacks through Plasmon‐Enhanced Raman Spectroscopy using Collapsible Nanofingers and Machine Learning

Abstract As the leading cause of death, heart attacks result in millions of deaths annually, with no end in sight. Early intervention is the only strategy for rescuing lives threatened by heart disease. However, the detection time of the fastest heart‐attack detection system is >15 min, which is too long considering the rapid passage of life. In this study, a machine learning (ML)‐driven system with a simple process, low‐cost, short detection time (only 10 s), and high precision is developed. By utilizing a functionalized nanofinger structure, even a trace amount of biomarker leaked before a heart attack can be captured. Additionally, enhanced Raman profiles are constructed for predictive analytics. Five ML models are developed to harness the useful characteristics of each Raman spectrum and provide early warnings of heart attacks with >98% accuracy. Through the strategic combination of nanofingers and ML algorithms, the proposed warning system accurately provides alerts on silent heart‐attack attempts seconds ahead of actual attacks.

60 APPLIED LIFE SCIENCES↗

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN↗

Fiber optic system for direct detection of CO2 leakage in carbon storage wells

The feasibility study focused on the development of new fiber for distributed chemical sensing (DCS) that will allow direct detection of CO 2 leakages in the environment. This is particularly important for monitoring well integrity for carbon capture and storage (CSS), to provide early warning for an incoming well failure and potential CO 2 leaking through it. We proposed Raman or IR interrogation within gas-filled Holey Fibers (HoFs) interleaved with standard solid core fibers and Fiber Bragg Grating (FBG) sections, so that the location and concentration of the gases would be provided simultaneously by means of reflectometry. The methodology would overcome current roadblocks to using fiber optics for CO 2 (and other gases) detection in wells with direct in-situ measurements of concentration along with other important parameters such as temperature and pressure as the baseline of environment background.

25 ENERGY STORAGE↗