Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Labeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Efficient Synthesis and HPLC-Based Characterization for Developing Vanadium-48-Labeled Vanadyl Acetylacetonate as a Novel Cancer Radiotracer for PET Imaging

Bis(acetylacetonato)oxidovanadium(IV) [(VO(acac) 2 ], generally known as vanadyl acetylacetonate, has been shown to be preferentially sequestered in malignant tissue. Vanadium-48 ( 48 V) generated with a compact medical cyclotron has been used to label VO(acac) 2 as a potential radiotracer in positron emission tomography (PET) imaging for the detection of cancer, but requires lengthy synthesis. Current literature protocols for the characterization of VO(acac) 2 require macroscale quantities of reactants and solvents to identify products by color and to enable crystallization that are not readily adaptable to the needs of radiotracer synthesis. We present an improved method to produce vanadium-48-labeled VO(acac) 2 , [ 48 V]VO(acac) 2 , and characterize it using high-performance liquid chromatography (HPLC) with radiation detection in combination with UV detection. The approach is suitable for radiotracer-level quantities of material. These methods are readily applicable for production of [ 48 V]VO(acac) 2 . Preliminary results of preclinical, small-animal PET studies are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Labeled Release - An experiment in radiorespirometry

The Labeled Release extraterrestrial life detection experiment onboard the Viking spacecraft is described as it will be implemented on the surface of Mars in 1976. This experiment is designed to detect heterotrophic life by supplying a dilute solution of radioactive organic substrates to a sample of Martian soil and monitoring for evolution of radioactive gas. A significantly attenuated response by a heat-sterilized control sample of the same soil would confirm a positive metabolic response. Experimental assumptions as well as criteria for the selection of organic substrates are presented. The Labeled Release nutrient has been widely tested, is versatile in eliciting terrestrial metabolic responses, and is stable to heat sterilization and to the long-term storage required before its use on Mars. A testing program has been conducted with flight-like instruments to acquire science data relevant to the interpretation of the Mars experiment. Factors involved in the delineation of a positive result are presented and the significance of the possible results discussed.

Levin, G. V.↗

Comparison of numeric keyboard and CRT line-labeled buttons for information access

Test were conducted to determine whether differences in speed and accuracy are experienced when using either line-labeled index buttons or a numeric keyboard for page selection in airborne CRT-display area navigation systems. The experiment was conducted with six airline pilots, each flying the same two simulated RNAV routes. Three pilot subjects used line-labeled buttons adjacent to the CRT screen, while three used a numeric keyboard for page access. The hypothesis of no differences in response times between the two modes of access could not be rejected.

Williams, D.↗

Recent results from the Viking Labeled Release experiment on Mars

The Labeled Release (LR) life detection experiment seeks detection of heterotrophic metabolism by monitoring radio-active gas evolution following the addition of a radioactive nutrient containing seven C-14 labeled organic substrates to surface material. LR results obtained on Mars prior to conjunction showed rapid evolution of radioactive counts upon addition of the nutrient to a fresh surface sample. The responses at both landing sites were quite similar. The additional results summarized in the present paper provide further information on the gas kinetics following a second injection of nutrient and on the effect of 'cold sterilization' of the Martian surface material. Specifically, it is shown that the production of gas from the LR nutrient is remarkably uniform; after reaction approaches completion, addition of more nutrient results in a net loss of the radioactive gas; the reactant in the Mars soil is completely inhibited by heating the soil to 160 C, and is largely inhibited by heating to 46 C. In contrast, exposure to 18 C for 2 sol (1 sol = 24.6 hr) does not appear to inhibit the reaction.

Levin, G. V.↗

A search for a nonbiological explanation of the Viking Labeled Release life detection experiment

The possibility of nonbiological reactions involving hydrogen peroxide being the source of the positive response detected by the Viking Labeled Release (LR) life detection experiment on the surface of Mars is assessed. Labeled release experiments were conducted in the LR Test Standards Module which replicates the Viking flight instrument configuration on analog Martian soils prepared to match the Viking inorganic analysis of Mars surface material to which an aqueous solution of hydrogen peroxide had been added. Getter experiments were also conducted to compare several reactions simultaneously in the presence and absence of UV radiation prior to the addition of nutrient. Hydrogen peroxide on certain analog soils is found to be capable of reproducing the kinetics and thermal information contained in the Mars data. The peroxide concentration necessary for this response, however, is shown to require a chemical stability or production rate much greater than seems likely in the Mars environment. As previous experiments have shown hydrogen peroxide to be the most likely nonbiological source of the positive LR response, it is concluded that the presence of a biological agent on Mars must not yet be ruled out.

Levin, G. V.↗

Labeling research in support of through-the-season area estimation

The development of LANDSAT-based through-the-season labeling procedures for corn and soybeans is discussed. A model for predicting labeling accuracy within key time periods throughout the growing season is outlined. Two methods for establishing the starting point of one key time period, viz., early season, are described. In addition, spectral-temporal characteristics for separating crops in the early season time period are discussed.

Colwell, R. N.↗

A labeling procedure for linear finite-state codes

A method to define the labels of the state diagram of a linear finite-state code is presented and investigated. This method is particularly suitable for simple hardware implementation since it simplifies the encoder structure. The method can also be applied to the labeling of a state diagram that is not completely connected to obtain a linear finite state code with larger free distance.

Cheung, K.-M.↗

Procedure For Labeling Linear Finite-State Codes

Method for labeling state diagrams of linear finite-state codes developed. Simplifies implementation of encoder hardware. Used to label state diagram not completely connected to obtain linear finite-state code that has larger free distance.

Cheung, Kar-Ming↗

Labeled trees and the efficient computation of derivations

The effective parallel symbolic computation of operators under composition is discussed. Examples include differential operators under composition and vector fields under the Lie bracket. Data structures consisting of formal linear combinations of rooted labeled trees are discussed. A multiplication on rooted labeled trees is defined, thereby making the set of these data structures into an associative algebra. An algebra homomorphism is defined from the original algebra of operators into this algebra of trees. An algebra homomorphism from the algebra of trees into the algebra of differential operators is then described. The cancellation which occurs when noncommuting operators are expressed in terms of commuting ones occurs naturally when the operators are represented using this data structure. This leads to an algorithm which, for operators which are derivations, speeds up the computation exponentially in the degree of the operator. It is shown that the algebra of trees leads naturally to a parallel version of the algorithm.

Grossman, Robert↗

Energy expenditure in space flight (doubly labelled water method) (8-IML-1)

The objective of the Energy Expenditure in Space Flight (ESS) experiment is to demonstrate and evaluate the doubly labeled water method of measuring the energy expended by crew members during approximately 7 days in microgravity. The doubly labeled water technique determines carbon dioxide production which is then used to calculate energy expenditure. The method relies on the equilibrium between oxygen in respiratory carbon dioxide and oxygen in body water. Because of this equilibrium, the kinetic of water turnover and respiration are interdependent. Under normal conditions, man contains small but significant amounts of deuterium and oxygen 18. Deuterium is eliminated from the body as water while oxygen 18 is eliminated as water and carbon dioxide. The difference in the turnover rates in the two isotopes is proportional to the carbon dioxide production. Deliberately enriching the total body water with both of these isotopes allows the isotope turnovers to be accurately measured in urine, plasma, or saliva samples. The samples are taken to the laboratory for analysis using an ion-ratio spectrometer.

Parsons, Howard G.↗

Photoaffinity labeling of regulatory subunits of protein kinase A in cardiac cell fractions of rats

Photoaffinity labeling in heart tissue of rats flown on Cosmos 2044 was used to measure the regulatory (R) subunits of adenosine monophosphate-dependent protein kinase. A significant decrease of RII subunits in the particulate cell fraction extract (S2; P less than 0.05 in all cases) was observed when extracts of tissue samples from vivarium controls were compared with those from flight animals. Photoaffinity labeling of the soluble fraction (S1) was observed to be unaffected by spaceflight or any of the simulation conditions. Proteins of the S2 fraction constitute a minor (less than 10 percent) component of the total, whereas the S1 fraction contained most of the cell proteins. Changes in a relatively minor aspect of adenosine monophosphate-mediated reactions are considered to be representative of a metabolic effect.

Mednieks, M. I.↗

Nucleotide-protectable labeling of sulfhydryl groups in subunit I of the ATPase from Halobacterium saccharovorum

The membrane ATPase from Halobacterium saccharovorum was purified as described by Hochstein et al. (1987) and was incubated with C-14 labeled N-ethylmaleimide (NEM), with and without adenine nucleotides, to determine the effect of nucleotides on the enzyme labeling. It was found that NEM incorporates into the 87,000-Da subunit (subunit I) of the enzyme and that the conditions for enzyme modification are similar to those which result in the inhibition of the enzyme activity. The presence of ATP, ADP, and AMP was found to reduce both the inhibitor incorporation and enzyme inhibition. It was shown that the reaction involves a modification of thiol groups.

Sulzner, Michael↗

Elucidation of the Cross-Link Structure of Nadic-End-Capped Polyimides Using NMR of C-13-Labeled Polymers

Solid NMR of C-13 isotope-labeled samples of PMR-15 was used to follow the cross-linking reaction of the nadic end cap. Some samples were labeled on one of the carbon atoms of the nadic end cap, and others on the methylene carbon atom of the methylenedianiline portion of the polymer. NMR spectra were run on these samples both before and after cross-linking. In this way, direct evidence of the major products of cross-linking under normal cure conditions is provided. The majority (approximately 85%) of the cross-linking derives from olefin polymerization through the double bond of the end cap. Approximately 15% of the products could come from a pathway involving a retro-Diels-Alder reaction. However, all of the products could be explained by a biradical intermediate without a retro-Diels-Alder reaction. Evidence is also presented that the methylene moiety in the methylenedianiline part of the polymer chain also participates in the cross-linking, albeit to a small extent, by a radical transfer reaction. Different cure conditions (higher temperatures, longer times) could change the relative distribution of the products.

Meador, Mary Ann B.↗

Ultrasensitive Label-free Electronic Chip for DNA Analysis Using Carbon Nanotube Nanoelectrode Arrays

There is a strong need for faster, cheaper, and simpler methods for nucleic acid analysis in today s clinical tests. Nanotechnologies can potentially provide solutions to these requirements by integrating nanomaterials with biofunctionalities. Dramatic improvement in the sensitivity and multiplexing can be achieved through the high-degree miniaturization. Here, we present our study in the development of an ultrasensitive label-free electronic chip for DNA/RNA analysis based on carbon nanotube nanoelectrode arrays. A reliable nanoelectrode array based on vertically aligned multi-walled carbon nanotubes (MWNTs) embedded in a SiO2 matrix is fabricated using a bottom-up approach. Characteristic nanoelectrode behavior is observed with a low-density MWNT nanoelectrode array in measuring both the bulk and surface immobilized redox species. The open-end of MWNTs are found to present similar properties as graphite edge-plane electrodes, with a wide potential window, flexible chemical functionalities, and good biocompatibility. A BRCA1 related oligonucleotide probe with 18 bases is covalently functionalized at the open ends of the MWNTs and specifically hybridized with an oligonucleotide target as well as a PCR amplicon. The guanine bases in the target molecules are employed as the signal moieties for the electrochemical measurements. Ru(bpy)3(2+) mediator is used to further amplify the guanine oxidation signal. This technique has been employed for direct electrochemical detection of label-free PCR amplicon through specific hybridization with the BRCAl probe. The detection limit is estimated to be less than approximately 1000 DNA molecules, approaching the limit of the sensitivity by laser-based fluorescence techniques in DNA microarray. This system provides a general electronic platform for rapid molecular diagnostics in applications requiring ultrahigh sensitivity, high-degree of miniaturization, simple sample preparation, and low- cost operation.

Li, Jun↗