Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Label noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Chemical kinetic studies of atmospheric reactions using tunable diode laser spectroscopy

IR absorption using tunable diode laser spectroscopy provides a sensitive and quantitative detection method for laboratory kinetic studies of atmospheric trace gases. Improvements in multipass cell design, real time signal processing, and computer controlled data acquisition and analysis have extended the applicability of the technique. We have developed several optical systems using off-axis resonator mirror designs which maximize path length while minimizing both the sample volume and the interference fringes inherent in conventional 'White' cells. Computerized signal processing using rapid scan (300 kHz), sweep integration with 100 percent duty cycle allows substantial noise reduction while retaining the advantages of using direct absorption for absolute absorbance measurements and simultaneous detection of multiple species. Peak heights and areas are determined by curve fitting using nonlinear least square methods. We have applied these techniques to measurements of: (1) heterogeneous uptake chemistry of atmospheric trace gases (HCl, H2O2, and N2O5) on aqueous and sulfuric acid droplets; (2) vapor pressure measurements of nitric acid and water over prototypical stratospheric aerosol (nitric acid trihydrate) surfaces; and (3) discharge flow tube kinetic studies of the HO2 radical using isotopic labeling for product channel and mechanistic analysis. Results from each of these areas demonstrate the versatility of TDL absorption spectroscopy for atmospheric chemistry applications.

Worsnop, Douglas R.↗

Double echo symmetry-based REDOR and RESPDOR pulse sequences for proton detected measurements of heteronuclear dipolar coupling constants

1 H{X} symmetry-based rotational echo double resonance pulse sequences (S-REDOR) and symmetry-based rotational echo saturation pulse double resonance (S-RESPDOR) solid-state NMR experiments have found widespread application for 1 H detected measurements of difference NMR spectra, dipolar coupling constants, and internuclear distances under conditions of fast magic angle spinning (MAS). In these experiments the supercycled $\text{R4}^2_1 (\text{SR4}^2_1)$ symmetry-based recoupling pulse sequence is typically applied to the 1 H spins to reintroduce heteronuclear dipolar couplings. However, the timing of $\text{SR4}^2_1$ and other symmetry-based pulse sequences must be precisely synchronized with the rotation of the sample, otherwise, the evolution of 1 H CSA and other interactions will not be properly refocused. For this reason, significant distortions are often observed in experimental dipolar dephasing difference curves obtained with S-REDOR or S-RESPDOR pulse sequences. Here we introduce a family of double echo (DE) S-REDOR/S-RESPDOR pulse sequences that function in an analogous manner to the recently introduced $t_1$-noise eliminated (TONE) family of dipolar heteronuclear multiple quantum coherence (D-HMQC) pulse sequences. Through numerical simulations and experiments the DE S-REDOR/S-RESPDOR sequences are shown to provide dephasing difference curves similar to those obtained with S-REDOR/S-RESPDOR. However, the DE sequences are more robust to the deviations of the MAS frequency from the ideal value that occurs during typical solid-state NMR experiments. In this work, the DE sequences are shown to provide more reliable 1 H detected dipolar dephasing difference curves for nuclei such as 15 N (with isotopic labelling), 183 W and 35 Cl. The double echo sequences are therefore recommended to be used in place of conventional S-REDOR/S-RESPDOR sequences for measurement of weak dipolar coupling constants and long-range distances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual-Color Optical Recording of Bioelectric Potentials by Polymer Electrochromism

Optical recording based on voltage-sensitive fluorescent reporters allows for spatial flexibility of measuring from desired cells, but photobleaching and phototoxicity of the fluorescent labels often limit their sensitivity and recording duration. Voltage-dependent optical absorption, rather than fluorescence, of electrochromic materials, would overcome these limitations to achieve long-term optical recording of bioelectrical signals. Electrochromic materials such as PEDOT:PSS possess the property that an applied voltage can either increase or decrease the light absorption depending on the wavelength. In this work, we harness this anticorrelated light absorption at two different wavelengths to significantly improve the signal detection. With dual-color detection, electrical activity from cells produces signals of opposite polarity, while artifacts, mechanical motions, and technical noises are uncorrelated or positively correlated. Using this technique, we are able to optically record cardiac action potentials with a high signal-to-noise ratio, 10 kHz sampling rate, >15 min recording duration, and no time-dependent degradation of the signal. Furthermore, we can reliably perform multiple recording sessions from the same culture for over 25 days.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flexible Learning-Free Segmentation and Reconstruction of Neural Volumes

Imaging is a dominant strategy for data collection in neuroscience, yielding stacks of images that often scale to gigabytes of data for a single experiment. Machine learning algorithms from computer vision can serve as a pair of virtual eyes that tirelessly processes these images, automatically detecting and identifying microstructures. Unlike learning methods, our Flexible Learning-free Reconstruction of Imaged Neural volumes (FLoRIN) pipeline exploits structure-specifc contextual clues and requires no training. This approach generalizes across diferent modalities, including serially-sectioned scanning electron microscopy (sSEM) of genetically labeled and contrast enhanced processes, spectral confocal refectance (SCoRe) microscopy, and high-energy synchrotron X-ray microtomography (μCT) of large tissue volumes. We deploy the FLoRIN pipeline on newly published and novel mouse datasets, demonstrating the high biological fdelity of the pipeline’s reconstructions. FLoRIN reconstructions are of sufcient quality for preliminary biological study, for example examining the distribution and morphology of cells or extracting single axons from functional data. Compared to existing supervised learning methods, FLoRIN is one to two orders of magnitude faster and produces high-quality reconstructions that are tolerant to noise and artifacts, as is shown qualitatively and quantitatively.

47 OTHER INSTRUMENTATION↗

Publisher Correction: Flexible Learning-Free Segmentation and Reconstruction of Neural Volumes

Imaging is a dominant strategy for data collection in neuroscience, yielding stacks of images that often scale to gigabytes of data for a single experiment. Machine learning algorithms from computer vision can serve as a pair of virtual eyes that tirelessly processes these images, automatically detecting and identifying microstructures. Unlike learning methods, our Flexible Learning-free Reconstruction of Imaged Neural volumes (FLoRIN) pipeline exploits structure-specific contextual clues and requires no training. This approach generalizes across different modalities, including serially-sectioned scanning electron microscopy (sSEM) of genetically labeled and contrast enhanced processes, spectral confocal reflectance (SCoRe) microscopy, and high-energy synchrotron X-ray microtomography (μCT) of large tissue volumes. We deploy the FLoRIN pipeline on newly published and novel mouse datasets, demonstrating the high biological fidelity of the pipeline’s reconstructions. FLoRIN reconstructions are of sufficient quality for preliminary biological study, for example examining the distribution and morphology of cells or extracting single axons from functional data. Compared to existing supervised learning methods, FLoRIN is one to two orders of magnitude faster and produces high-quality reconstructions that are tolerant to noise and artifacts, as is shown qualitatively and quantitatively.

Shahbazi, Ali↗

Proton-detected 15 N- 1 H dipolar coupling/ 1 H chemical shift correlation experiment for the measurement of NH distances in biological solids under fast MAS solid-state NMR

Measurement of distances from dipolar couplings is essential for structural characterization, refinement and validation using the solid-state nuclear magnetic resonance (ssNMR) spectroscopy. Particularly, knowledge about NH dipolar interactions in biological solids is important for understanding the hydrogen (H)-bonding interactions, molecular geometry and spin dynamics. In this regard, we have proposed a proton-detected two-dimensional (2D) 15 N- 1 H dipolar coupling/ 1 H chemical shift correlation experiment using the C-symmetry based windowless recoupling of chemical shift anisotropy (ROCSA) in combination with the DIPSHIFT pulse-based method for the measurement of short NH distances in the isotopically labeled and naturally abundant biological solids at fast magic angle spinning (MAS) rates (40–70 kHz). Our proposed method results in undistorted recoupled 15 N- 1 H dipolar coupling powder lineshapes that are free from the recoupled 1 H CSA contributions under the 15 N evolution, a feature that is essential for the measurement of NH distances with improved accuracy (± 500 Hz in terms of the NH dipolar couplings). The pulse sequence developed in the present study is also insensitive to the 1H–1H homonuclear dipolar interactions, relaxation effects owing to its constant-time implementation, and t1-noise from the fluctuations in the MAS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bayesian Redshift Classification of Emission-line Galaxies with Photometric Equivalent Widths

We present a Bayesian approach to the redshift classification of emission-line galaxies when only a single emission line is detected spectroscopically. We consider the case of surveys for high-redshift Lyα-emitting galaxies (LAEs), which have traditionally been classified via an inferred rest-frame equivalent width (EW; W{sub Lyα}) greater than 20 Å. Our Bayesian method relies on known prior probabilities in measured emission-line luminosity functions and EW distributions for the galaxy populations, and returns the probability that an object in question is an LAE given the characteristics observed. This approach will be directly relevant for the Hobby–Eberly Telescope Dark Energy Experiment (HETDEX), which seeks to classify ∼10{sup 6} emission-line galaxies into LAEs and low-redshift [O II] emitters. For a simulated HETDEX catalog with realistic measurement noise, our Bayesian method recovers 86% of LAEs missed by the traditional W{sub Lyα} > 20 Å cutoff over 2 < z < 3, outperforming the EW cut in both contamination and incompleteness. This is due to the method’s ability to trade off between the two types of binary classification error by adjusting the stringency of the probability requirement for classifying an observed object as an LAE. In our simulations of HETDEX, this method reduces the uncertainty in cosmological distance measurements by 14% with respect to the EW cut, equivalent to recovering 29% more cosmological information. Rather than using binary object labels, this method enables the use of classification probabilities in large-scale structure analyses. It can be applied to narrowband emission-line surveys as well as upcoming large spectroscopic surveys including Euclid and WFIRST.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploring Sentinel-1 and Sentinel-2 diversity for Flood inundation mapping using deep learning

Identification of flood water extent from satellite images has historically relied on either synthetic aperture radar (SAR) or multi-spectral (MS) imagery. MS sensors are limited to cloud free conditions, whereas SAR imagery is plagued by noise-like speckle. Prior studies that use combinations of MS and SAR data to overcome individual limitations of these sensors have not fully examined sensitivity of flood mapping performance to different combinations of SAR and MS derived spectral indices or band transformations in color space. This study explores the use of diverse bands of Sentinel 2 (S2) through well-established water indices and Sentinel 1 (S1) derived SAR imagery along with their combinations to assess their capability for generating accurate flood inundation maps. The robustness in performance of S-1 and S-2 band combinations was evaluated using 446 hand labeled flood inundation images spanning across 11 flood events from Sen1Floods11 dataset which are highly diverse in terms of land cover as well as location. A modified K-fold cross validation approach is used to evaluate the performance of 32 combinations of S1 and S2 bands using a fully connected deep convolutional neural network known as U-Net. Our results indicated that usage of elevation information has improved the capability of S1 imagery to produce more accurate flood inundation maps. Compared to a median F1 score of 0.62 when using only S1 bands, the combined use of S1 and elevation information led to an improved median F1 score of 0.73. Water extraction indices based on S2 bands have a statistically significant superior performance in comparison to S1. Among all the band combinations, HSV (Hue, Saturation, Value) transformation of S2 bands provides a median F1 score of 0.9, outperforming the commonly used water spectral indices owing to HSV’s transformation’s superior contrast distinguishing abilities. Additionally, U-Net algorithm was able to learn the relationship between raw S2 based water extraction indices and their corresponding raw S2 bands, but not of HSV owing to relatively complex computation involved in the latter. Results of the paper establishes important benchmarks for the extension of S1 and S2 data-based flood inundation mapping efforts over large spatial extents.

Goutam Konapala↗

Editorial overview: Unlocking the secrets of nongenetic plasticity, one cell at a time

Cellular noise, the non-genetic variability observed among isogenic cells, arises from factors such as growth conditions, aging, and stochastic gene expression, influencing cell stress-response, metabolism, morphology, and size. Here, such plasticity, while critical for adaptation, often goes unnoticed with traditional population-averaging biotechnologies that inevitably mask cell-specific variations and prompting the question, "What else might we be missing". However, recent breakthroughs in optical imaging, microfluidics, and omics, are beginning to uncover the complexity of cellular plasticity. This special is-sue highlights some of these breakthroughs, with key contributions including innovations in multimodal chemical imaging, label-free microscopy, spatial and temporal omics, and droplet-based microfluidics. Collectively, these cutting-edge tools provide unprecedent-ed insights into non-genetic cell-to-cell variability, enhancing our understanding of cellu-lar plasticity and its implications for health, energy, and ecology.

59 BASIC BIOLOGICAL SCIENCES↗

SU-G-206-08: How Should Focal Spot Be Chosen for Optimized CT Imaging with Dose Modulation?

Purpose: To choose the preferred focal spot for achieving optimized CT image quality with balanced tube heating considerations. Methods: An anthropomorphic pelvic phantom was scanned using a GE Discovery CT750 HD at 120 and 140kVp, 0.8s rotation time, and pitch of 0.984. “Smart mA” was enabled to simulate a routine abdomen–pelvis CT scan. Permissible mA values at 120 and 140 kVp were obtained from the Serial Load Rating table (for mimicking a busy CT clinical operation) in the scanner Technical Reference Manual. At each kVp station and two Noise Index levels, the mA Upper Limit was set above/below the permissible mA values. Scanned mA values and focal spot (FS) used were obtained from the DICOM header of each image, and the FS-mA relationship was analyzed. For visual confirmation beyond recorded FS information, a CatPhan with a fat-ring attached for mimicking patient size/shape was scanned at 120kVp. A group of radiologists/physicists compared a pair of CatPhan images qualitatively. Lastly, a number of patient cases were evaluated to confirm the FS-mA relationship. Results: When preset Upper Limit values were above the permissible mA values, the Large FS (labeled 1.2) was used in scans, even if the maximum scanned mA values were much lower than the permissible values at both 120 and 140 kVp. Otherwise the Small FS (labeled 0.7) was used. Visual evaluation of the high contrast module of CatPhan and additional analysis of patient cases further confirmed that the preset Upper Limit determines which focal spot is to be used, not the actual maximum mA value to be scanned. Conclusion: Specific FS can be selected by setting up appropriate mA Upper Limit in a protocol. CT protocols could be optimized by selecting appropriate FS for improving patient image quality, especially benefiting the small size and pediatric patients.

60 APPLIED LIFE SCIENCES↗

Transport of intensity equation: a tutorial

When it comes to “phase measurement” or “quantitative phase imaging”, many people will automatically connect them with “laser” and “interferometry”. Indeed, conventional quantitative phase imaging and phase measurement techniques generally rely on the superposition of two beams with a high degree of coherence: complex interferometric configurations, stringent requirements on the environmental stabilities, and associated laser speckle noise severely limit their applications in optical imaging and microscopy. On a different note, as one of the most well-known phase retrieval approaches, the transport of intensity equation (TIE) provides a new non-interferometric way to access quantitative phase information through intensity only measurement. Despite the insufficiency for interferometry, TIE is applicable under partially coherent illuminations (like the Köhler’s illumination in a conventional microscope), permitting optimum spatial resolution, higher signal-to-noise ratio, and better image quality. In this tutorial, we give an overview of the basic principle, research fields, and representative applications of TIE, focus particularly on optical imaging, metrology, and microscopy. The purpose of this tutorial is twofold. It should serve as a self-contained introduction to TIE for readers with little or no knowledge of TIE. On the other hand, it attempts to give an overview of recent developments in this field. These results highlight a new era in which strict coherence and interferometry are no longer prerequisites for quantitative phase imaging and diffraction tomography, paving the way toward new generation label-free three-dimensional microscopy, with applications in all branches of biomedicine.

42 ENGINEERING↗

Clear-sky detection for PV degradation analysis using multiple regression

A method is presented to detect clear-sky periods for plane-of-array irradiance time-averaged data that is based on the algorithm originally described by Reno and Hansen. Here we show this new method improves the state-of-the-art by providing accurate detection at longer data averaging intervals. Moreover, our new method detects clear periods in plane-of-array data, which is novel. The new method is developed by applying a Design of Experiment approach to optimize the parameters used in the Reno method, and Monte Carlo simulations are used to understand the robustness of the found parameters. Clear-sky detection accuracy is compared among four methods: the Reno method, the default clear-sky filter in RdTools, the Ellis method, and the method outlined in this work, using a hand-labeled two-year data set of 1-min plane-of-array irradiance for a fixed tilt system. The RdTools clear-sky filter is marred by excessive false positives. The other methods all perform well at 1-min data intervals; the method developed here provides more accurate detection at longer data averaging intervals. We show that the parameters are directly linked to the data frequency in the hope that these input variables may not have to be optimized for every data frequency and location. However, only a single fixed system in one location was carefully examined. Finally, we illustrate how accurate determination of clear-sky conditions helps to eliminate data noise and bias in the assessment of long-term performance of PV plants.

14 SOLAR ENERGY↗

Reaching the quantum limit of sensitivity in electron spin resonance

The detection and characterization of paramagnetic species by electron spin resonance (ESR) spectroscopy is widely used throughout chemistry, biology and materials science, from in vivo imaging to distance measurements in spin-labelled proteins. ESR relies on the inductive detection of microwave signals emitted by the spins into a coupled microwave resonator during their Larmor precession. However, such signals can be very small, prohibiting the application of ESR at the nanoscale (for example, at the single-cell level or on individual nanoparticles). Here in this work, using a Josephson parametric microwave amplifier combined with high-quality-factor superconducting microresonators cooled at millikelvin temperatures, we improve the state-of-the-art sensitivity of inductive ESR detection by nearly four orders of magnitude. We demonstrate the detection of 1,700 bismuth donor spins in silicon within a single Hahn echo with unit signal-to-noise ratio, reduced to 150 spins by averaging a single Carr-Purcell-Meiboom-Gill sequence. This unprecedented sensitivity reaches the limit set by quantum fluctuations of the electromagnetic field instead of thermal or technical noise, which constitutes a novel regime for magnetic resonance. In conclusion, the detection volume of our resonator is ~0.02nl, and our approach can be readily scaled down further to improve sensitivity, providing a new versatile toolbox for ESR at the nanoscale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatio-Temporal Deep Graph Network for Event Detection, Localization, and Classification in Cyber-Physical Electric Distribution System

This work proposes a deep graph learning framework to identify, locate, and classify power, cyber, and cyber power events at the distribution system level. The proposed algorithm jointly exploits spatial, temporal, and node-level cyber and physical data features. The developed graph neural network, together with a deep autoencoder, utilizes physical measurements from distribution level phasor measurement units and cyber data from communication network logs. The spatial structure of the synchrophasor measurements and network is incorporated through a weighted adjacency matrix. The temporal structure is incorporated by defining a spatial operation in the gated recurrent unit. This spatio-temporal learning element resides inside a power event detection, localization, and classification module that provides the degree of confidence for an event label. To accurately pinpoint the location of an event to the nearest bus equipped with a measurement unit, a combination of squared error and proximity score is utilized. Also included is a cyber event detection module that employs heteroskedasticity to analyze the significance of various cyber features during different types of attacks. Finally, a dual-bit cyber-power decision table determines the nature of the event. The proposed method is validated on two distribution systems modeled in OPAL-RT/Hypersim with limited phasor measurement units for different possible physical and cyber events. Further analyses include comparison with other state-of-the-art methods and validation in the presence of measurement noise. As a result, our method outperforms existing approaches and achieves an average detection accuracy of 97.97%, F1-score of 96.88%, precision of 96.53%, and recall of 98.57%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microsecond fingerprint stimulated Raman spectroscopic imaging by ultrafast tuning and spatial-spectral learning

Label-free vibrational imaging by stimulated Raman scattering (SRS) provides unprecedented insight into real-time chemical distributions. Specifically, SRS in the fingerprint region (400–1800 cm -1 ) can resolve multiple chemicals in a complex bio-environment. However, due to the intrinsic weak Raman cross-sections and the lack of ultrafast spectral acquisition schemes with high spectral fidelity, SRS in the fingerprint region is not viable for studying living cells or large-scale tissue samples. Here, we report a fingerprint spectroscopic SRS platform that acquires a distortion-free SRS spectrum at 10 cm -1 spectral resolution within 20 µs using a polygon scanner. Meanwhile, we significantly improve the signal-to-noise ratio by employing a spatial-spectral residual learning network, reaching a level comparable to that with 100 times integration. Collectively, our system enables high-speed vibrational spectroscopic imaging of multiple biomolecules in samples ranging from a single live microbe to a tissue slice.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of the Accuracy of Actuation Electronics in the Laser Interferometer Space Antenna Pathfinder

The Laser Interferometer Space Antenna Pathfinder (LPF) main observable, labelled∆g, is the differential force per unit mass acting on the two test masses in free fall condition, after the contribution of all non-gravitational forces have been compensated. At low frequencies the differential force is compensated by an applied electrostatic actuation force,which then must be subtracted from the measured acceleration to obtain∆g. Any inaccuracy in the actuation force contaminates the residual acceleration. This study investigates the accuracy of the electrostatic actuation system and its impact on the LPF main observable. It is shown that the inaccuracy is mainly caused by the rounding errors in the waveform processing and also by the random error caused by the analog to digital converter (ADC) random noise in the control loop. Both errors are one order of magnitude smaller than the resolution of the commanded voltages. We developed a simulator based on the LPF design to compute the close-to-reality actuation voltages and consequently, the resulting actuation forces. The simulator is applied in post-processing the LPF data.

M. Armano↗

PRECISE INFRARED RADIAL VELOCITIES FROM KECK/NIRSPEC AND THE SEARCH FOR YOUNG PLANETS

We present a high-precision infrared radial velocity (RV) study of late-type stars using spectra obtained with NIRSPEC at the W. M. Keck Observatory. RV precisions of 50 m s{sup -1} are achieved for old field mid-M dwarfs using telluric features for wavelength calibration. Using this technique, 20 young stars in the {beta} Pic (age {approx} 12 Myr) and TW Hya (age {approx} 8 Myr) Associations were monitored over several years to search for low-mass companions; we also included the chromospherically active field star GJ 873 (EV Lac) in this survey. Based on comparisons with previous optical observations of these young active stars, RV measurements at infrared wavelengths mitigate the RV noise caused by star spots by a factor of {approx}3. Nevertheless, star spot noise is still the dominant source of measurement error for young stars at 2.3 {mu}m, and limits the precision to {approx}77 m s{sup -1} for the slowest rotating stars (v sin i < 6 km s{sup -1}), increasing to {approx}168 m s{sup -1} for rapidly rotating stars (v sin i > 12 km s{sup -1}). The observations reveal both GJ 3305 and TWA 23 to be single-lined spectroscopic binaries; in the case of GJ 3305, the motion is likely caused by its 0.''09 companion, identified after this survey began. The large amplitude, short-timescale variations of TWA 13A are indicative of a hot Jupiter-like companion, but the available data are insufficient to confirm this. We label it as a candidate RV variable. For the remainder of the sample, these observations exclude the presence of any 'hot' (P < 3 days) companions more massive than 8 M{sub Jup} and any 'warm' (P < 30 days) companions more massive than 17 M{sub Jup}, on average. Assuming an edge-on orbit for the edge-on disk system AU Mic, these observations exclude the presence of any hot Jupiters more massive than 1.8 M{sub Jup} or warm Jupiters more massive than 3.9 M{sub Jup}.

79 ASTRONOMY AND ASTROPHYSICS↗

Neural network-based classification and regression of magnetohydrodynamic modes in tokamaks

We present a machine learning-based magnetohydrodynamic (MHD) classifier and regressor that utilizes real or complex-valued 3D magnetic sensor array data to determine neoclassical tearing mode (NTM) onset times in tokamaks with millisecond accuracy. The input dataset consists of poloidal profiles of complex Fourier amplitudes with an n = 1 toroidal mode number from 144 human-labeled ITER Baseline Scenario discharges in the DIII-D tokamak, spanning both tearing-dominated and sawtooth-dominated regimes. Since m, n = 2,1 NTMs frequently emerge alongside sawteeth at the same frequency in this scenario, the focus is on isolating the m = 1 and m = 2 components of the n = 1 MHD mode near the tearing onset. To improve model regularization and prediction stability, singular value decomposition was applied to balance the sawtooth and tearing datasets. The enriched datasets facilitated training neural networks that learn the key distinguishing features of sawtooth and tearing modes in the poloidal profiles of their magnetic amplitude and phase. When the modes occur independently, the networks achieve perfect classification due to the modes’ distinct characteristics and low measurement noise. In the more experimentally relevant case where both modes coexist, the networks maintain exceptional performance across key metrics. Tests on synthetic data with known ground truth demonstrate the superior accuracy of the neural network trained on complex-valued input compared to models using real amplitude, phase, or pseudo-complex data, achieving both a mean time delay and standard deviation below 1 ms. Notably, standard linear regression methods fitting the dominant singular modes to the data closely match the neural network’s performance. Applying these methods across a broad range of H-mode scenarios will enable future studies to systematically identify dominant NTM triggers as scenario-specific variables, paving the way for more effective tearing mode avoidance strategies in future fusion reactor designs.

machine learning↗