Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LUTETIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Performance of the Tachyon Time-of-Flight PET Camera

We have constructed and characterized a time-of-flight Positron Emission Tomography (TOF PET) camera called the Tachyon. The Tachyon is a single-ring Lutetium Oxyorthosilicate (LSO) based camera designed to obtain significantly better timing resolution than the ~ 550 ps found in present commercial TOF cameras, in order to quantify the benefit of improved TOF resolution for clinically relevant tasks. The Tachyon's detector module is optimized for timing by coupling the 6.15 ×25 mm 2 side of 6.15 ×6.15 ×25 mm 3 LSO scintillator crystals onto a 1-inch diameter Hamamatsu R-9800 PMT with a super-bialkali photocathode. We characterized the camera according to the NEMA NU 2-2012 standard, measuring the energy resolution, timing resolution, spatial resolution, noise equivalent count rates and sensitivity. The Tachyon achieved a coincidence timing resolution of 314 ps +/- 20 ps FWHM over all crystal-crystal combinations. Experiments were performed with the NEMA body phantom to assess the imaging performance improvement over non-TOF PET. We find that the results show that at a matched contrast, incorporating 314 ps TOF reduces the standard deviation of the contrast by a factor of about 2.3.

47 OTHER INSTRUMENTATION↗

Beam Test Results of the RADiCAL—A Radiation Hard Innovative EM Calorimeter

High-performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include developing scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant neutron and ionizing radiation exposure. The radiation-hard innovative calorimeter (RADiCAL) is an approach that incorporates radiation tolerant materials in a sampling “shashlik”-style calorimeter configuration, using quartz capillaries filled with organic liquid or polymer-based wavelength shifters embedded in layers of tungsten plates and lutetium-yttrium oxyorthosilicate (LYSO) crystals. Here, this novel design intends to address the priority research directions (PRD) for calorimetry listed in the DOE basic research needs (BRN) workshop for high energy physics (HEP) instrumentation. Here we report preliminary results from an experimental run at the Fermilab Test Beam Facility (FTBF) in June 2022. These tests demonstrate that the RADiCAL concept is capable of ¡50 ps timing resolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assembly and testing of a large zoom lens for proton radiography

A zoom lens has been designed for proton radiography applications. Radiographic images are recorded at the end of an accelerator, where protons exit an aluminum vacuum window, producing a shadowgraph image onto an LYSO (lutetium yttrium orthosilicate) scintillator. Emission from this 5-inch-square scintillator reflects off a pellicle and is then collected by a zoom lens located 24 inches away. Proton radiography can make high-speed, multi-frame radiographs or radiographic movies. This zoom lens provides 2X magnification for viewing different object sizes. The zoom lens incorporates eleven lenses, including a moving doublet that changes the magnification. Refocus of the camera is required when zooming. Only one moving doublet lens is required to change magnification. The stop was anchored to the moving doublet, and its diameter is unchanged throughout magnification changes. The entire lens system is housed in a cylindrical tube. This lens will be used with a 10-frame camera with a 44 × 44 mm square image format and 1100 × 1100 pixel resolution. Suppressing stray light is very important in this lens system. Radial compensation is controlled by two locking micrometers on element 9, which relaxes the mechanical tolerancing. A helical cam barrel using a linear rail controls the movement of the doublet. Alignment of the mechanical gears will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout

Purpose: Depth encoding detectors are required to improve the spatial resolution and spatial resolution uniformity of small animal positron emission tomography (PET) scanners, as well as dedicated breast and brain scanners. Depth of interaction (DOI) can be measured by using dual-ended readout of lutetium oxyorthosilicate (LSO) scintillator arrays with position-sensitive avalanche photodiodes. Inter-crystal reflectors and crystal surface treatments play important roles in determining the performance of dual-ended detectors. In this paper, the authors evaluated five LSO arrays made with three different intercrystal reflectors and with either polished or unpolished crystal surfaces. Methods: The crystal size in all arrays was 1.5 mm, which is typical of the detector size used in small animal and dedicated breast scanners. The LSO arrays were measured with dual-ended readout and were compared in terms of flood histogram, energy resolution, and DOI resolution performance. Results: The four arrays using enhanced specular reflector (ESR) and Toray reflector provided similar quality flood histograms and the array using Crystal Wrap reflector gave the worst flood histogram. The two arrays using ESR reflector provided the best energy resolution and the array using Crystal Wrap reflector yielded the worst energy resolution. All arrays except the polished ESR array provided good DOI resolution ranging from 1.9 mm to 2.9 mm. DOI resolution improved as the gradient in light collection efficiency with depth (GLCED) increased. The geometric mean energies were also calculated for these dual-ended readout detectors as an alternative to the conventional summed total energy. It was shown that the geometric mean energy is advantageous in that it provides more uniform photopeak amplitude at different depths for arrays with high GLCED, and is beneficial in event selection by allowing a fixed energy window independent of depth. A new method of DOI calculation that improved the linearity of DOI ratio vs depth and simplifies the DOI calibration procedure also was developed and tested. Conclusions: The results of these studies provide useful guidance in selecting the proper reflectors and crystal surface treatments when LSO arrays are used for high-resolution PET applications in small animal scanners or dedicated breast and brain scanners.

60 APPLIED LIFE SCIENCES↗

Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ion-beam therapy monitoring

Purpose: External beam radiotherapy with protons and heavier ions enables a tighter conformation of the applied dose to arbitrarily shaped tumor volumes with respect to photons, but is more sensitive to uncertainties in the radiotherapeutic treatment chain. Consequently, an independent verification of the applied treatment is highly desirable. For this purpose, the irradiation-induced β{sup +}-emitter distribution within the patient is detected shortly after irradiation by a commercial full-ring positron emission tomography/x-ray computed tomography (PET/CT) scanner installed next to the treatment rooms at the Heidelberg Ion-Beam Therapy Center (HIT). A major challenge to this approach is posed by the small number of detected coincidences. This contribution aims at characterizing the performance of the used PET/CT device and identifying the best-performing reconstruction algorithm under the particular statistical conditions of PET-based treatment monitoring. Moreover, this study addresses the impact of radiation background from the intrinsically radioactive lutetium-oxyorthosilicate (LSO)-based detectors at low counts. Methods: The authors have acquired 30 subsequent PET scans of a cylindrical phantom emulating a patientlike activity pattern and spanning the entire patient counting regime in terms of true coincidences and random fractions (RFs). Accuracy and precision of activity quantification, image noise, and geometrical fidelity of the scanner have been investigated for various reconstruction algorithms and settings in order to identify a practical, well-suited reconstruction scheme for PET-based treatment verification. Truncated listmode data have been utilized for separating the effects of small true count numbers and high RFs on the reconstructed images. A corresponding simulation study enabled extending the results to an even wider range of counting statistics and to additionally investigate the impact of scatter coincidences. Eventually, the recommended reconstruction scheme has been applied to exemplary postirradiation patient data-sets. Results: Among the investigated reconstruction options, the overall best results in terms of image noise, activity quantification, and accurate geometrical recovery were achieved using the ordered subset expectation maximization reconstruction algorithm with time-of-flight (TOF) and point-spread function (PSF) information. For this algorithm, reasonably accurate (better than 5%) and precise (uncertainty of the mean activity below 10%) imaging can be provided down to 80 000 true coincidences at 96% RF. Image noise and geometrical fidelity are generally improved for fewer iterations. The main limitation for PET-based treatment monitoring has been identified in the small number of true coincidences, rather than the high intrinsic random background. Application of the optimized reconstruction scheme to patient data-sets results in a 25% − 50% reduced image noise at a comparable activity quantification accuracy and an improved geometrical performance with respect to the formerly used reconstruction scheme at HIT, adopted from nuclear medicine applications. Conclusions: Under the poor statistical conditions in PET-based treatment monitoring, improved results can be achieved by considering PSF and TOF information during image reconstruction and by applying less iterations than in conventional nuclear medicine imaging. Geometrical fidelity and image noise are mainly limited by the low number of true coincidences, not the high LSO-related random background. The retrieved results might also impact other emerging PET applications at low counting statistics.

60 APPLIED LIFE SCIENCES↗

Yb:Lu 2 O 3 single-crystal fiber: spectroscopy, amplification, and lasing

For the first time, to our knowledge, a lutetium oxide (Lu 2 O 3 ) single-crystal fiber (SCF) laser is demonstrated. The laser heated pedestal growth (LHPG) technique was used to pull Yb-doped Lu 2 O 3 SCFs between 10 and 50 mm long and with diameters between 150 and 225 μm. Spectroscopic properties are first reported in detail, as the two-site nature of the host demands careful attention. Short 10 mm long, unclad fibers were used as amplifier media in a single pass copropagating configuration. Then, a 50 mm long 0.1%Yb:Lu 2 O 3 SCF with a 180 μm diameter was configured to lase by butt-coupling mirrors on the ends and pumping at 976 nm. Lasing occurred at the 1033 nm peak of Yb, and a maximum output of around 300 mW is reported. Finally, the results indicate there is no, at least obvious, fundamental reason that should deter future interest in Lu 2 O 3 as a SCF platform, which has been considered to have high potential for power scaling based on its beneficial intrinsic properties.

47 OTHER INSTRUMENTATION↗

Rare Earth Element Concentrations in Geothermal Wells at the Puna Geothermal Field, Hawaii

Rare earth element concentrations in the geothermal wells at the Puna geothermal field, Hawaii. Samples taken from geothermal wells KS-5, KS-6W, KS-9W, KS-14E, and KS-16N. Includes pH and concentrations for Cerium, Dysprosium, Erbium, Europium, Gadolinium, Holmium, Lanthanum, Lutetium, Neodymium, Praseodymium, Samarium, Terbium, Thulium, Yttrium, and Ytterbium. Samples collected on November 11-17, 2016.

15 GEOTHERMAL ENERGY↗

Rare Earth Element Concentrations from Wells at the Don A. Campbell Geothermal Plant, Nevada

* Requires permission of originators for use. Rare earth element concentrations in thermal springs from the wells at the Don A. Campbell geothermal plant, Nevada. Samples taken from geothermal wells 85-11, 65-11, 54-11, and 64-11. Includes pH and concentrations for Cerium, Dysprosium, Erbium, Europium, Gadolinium, Holmium, Lanthanum, Lutetium, Neodymium, Praseodymium, Samarium, Terbium, Thulium, Yttrium, and Ytterbium. Samples from Don A. Campbell, Nevada collected on October 14, 2016.

15 GEOTHERMAL ENERGY↗

Production and purification of research scale 161 Tb using cation-exchange semi-preparative HPLC for radiopharmaceutical applications

Terbium-161 ( 161 Tb) is emerging as a promising radionuclide for cancer therapy due to its favorable nuclear properties that are similar to clinically established lutetium-177 ( 177 Lu) along with its therapeutic edge arising from the higher number of Auger and conversion electrons per decay. These low energy electrons result in higher cytotoxicity within a short range of the decaying nuclei to enhance therapeutic efficacy. Despite these promising characteristics, a significant challenge remains in the lack of a domestic 161 Tb supply in the United States, which poses an obstacle to the advancement of 161 Tb-based radiopharmaceutical research and development. Here, this study developed a reliable cation-exchange high-performance liquid chromatography-based method for purification of reactor-produced 161 Tb at quantities suitable to support research and preclinical studies. The purified 161 Tb product showed high radionuclidic purity with excellent radiochemical purity, and the successful labeling studies with the DOTA chelator and DOTA-TATE peptide demonstrated the effective incorporation of the purified 161 Tb into radiopharmaceuticals designed for targeted cancer therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Materials Data on Ba2LuSbO6 by Materials Project

Lu(BaO3)2Sb is alpha Rhenium trioxide-derived structured and crystallizes in the tetragonal I4/mmm space group. The structure is three-dimensional and consists of two antimony molecules, two lutetium molecules, and one BaO3 framework. In the BaO3 framework, Ba2+ is bonded to six O2- atoms to form corner-sharing BaO6 octahedra. The corner-sharing octahedral tilt angles are 0°. There are four shorter (2.35 Å) and two longer (2.36 Å) Ba–O bond lengths. There are four inequivalent O2- sites. In the first O2- site, O2- is bonded in a linear geometry to two equivalent Ba2+ atoms. In the second O2- site, O2- is bonded in a linear geometry to two equivalent Ba2+ atoms. In the third O2- site, O2- is bonded in a linear geometry to two equivalent Ba2+ atoms. In the fourth O2- site, O2- is bonded in a linear geometry to two equivalent Ba2+ atoms. Both O–Ba bond lengths are 2.35 Å.

36 MATERIALS SCIENCE↗

Materials Data on Lu2(Ni5B3)3 by Materials Project

LuLu(Ni5B3)3 crystallizes in the orthorhombic Cmce space group. The structure is three-dimensional and consists of eight lutetium molecules and one Lu(Ni5B3)3 framework. In the Lu(Ni5B3)3 framework, Lu3+ is bonded in a 2-coordinate geometry to six B3- atoms. There are a spread of Lu–B bond distances ranging from 2.74–2.90 Å. There are ten inequivalent Ni+1.40+ sites. In the first Ni+1.40+ site, Ni+1.40+ is bonded in a distorted rectangular see-saw-like geometry to four B3- atoms. There are a spread of Ni–B bond distances ranging from 1.96–2.14 Å. In the second Ni+1.40+ site, Ni+1.40+ is bonded in a 4-coordinate geometry to five B3- atoms. There are a spread of Ni–B bond distances ranging from 2.01–2.54 Å. In the third Ni+1.40+ site, Ni+1.40+ is bonded in a 5-coordinate geometry to five B3- atoms. There are a spread of Ni–B bond distances ranging from 2.07–2.14 Å. In the fourth Ni+1.40+ site, Ni+1.40+ is bonded in a 4-coordinate geometry to four B3- atoms. There are a spread of Ni–B bond distances ranging from 1.97–2.12 Å. In the fifth Ni+1.40+ site, Ni+1.40+ is bonded in an octahedral geometry to six B3- atoms. There are two shorter (2.32 Å) and four longer (2.49 Å) Ni–B bond lengths. In the sixth Ni+1.40+ site, Ni+1.40+ is bonded in a square co-planar geometry to four B3- atoms. There are two shorter (2.00 Å) and two longer (2.14 Å) Ni–B bond lengths. In the seventh Ni+1.40+ site, Ni+1.40+ is bonded in a distorted T-shaped geometry to four B3- atoms. There are a spread of Ni–B bond distances ranging from 2.04–2.54 Å. In the eighth Ni+1.40+ site, Ni+1.40+ is bonded in a see-saw-like geometry to four B3- atoms. There are a spread of Ni–B bond distances ranging from 2.01–2.14 Å. In the ninth Ni+1.40+ site, Ni+1.40+ is bonded in a 4-coordinate geometry to four B3- atoms. There are two shorter (2.01 Å) and two longer (2.07 Å) Ni–B bond lengths. In the tenth Ni+1.40+ site, Ni+1.40+ is bonded in a distorted rectangular see-saw-like geometry to four B3- atoms. There are a spread of Ni–B bond distances ranging from 2.13–2.22 Å. There are six inequivalent B3- sites. In the first B3- site, B3- is bonded in a 9-coordinate geometry to one Lu3+, seven Ni+1.40+, and one B3- atom. The B–B bond length is 1.97 Å. In the second B3- site, B3- is bonded to seven Ni+1.40+ atoms to form distorted corner-sharing BNi7 pentagonal bipyramids. In the third B3- site, B3- is bonded in a 9-coordinate geometry to eight Ni+1.40+ and one B3- atom. The B–B bond length is 1.88 Å. In the fourth B3- site, B3- is bonded in a 9-coordinate geometry to eight Ni+1.40+ and one B3- atom. In the fifth B3- site, B3- is bonded in a 9-coordinate geometry to one Lu3+, seven Ni+1.40+, and one B3- atom. The B–B bond length is 1.69 Å. In the sixth B3- site, B3- is bonded in a 9-coordinate geometry to one Lu3+, seven Ni+1.40+, and one B3- atom.

36 MATERIALS SCIENCE↗

Materials Data on Lu2CuAs3 by Materials Project

(LuAs)2CuAs crystallizes in the tetragonal P4/mmm space group. The structure is zero-dimensional and consists of one arsenic molecule, one copper molecule, and two lutetium arsenide molecules.

36 MATERIALS SCIENCE↗

First observation of the production of three massive vector bosons and search for long-lived particles using delayed photons in pp collisions at $\sqrt{s}=13\text{ TeV}$

This thesis presents the first observation of the production of three massive vector bosons (VVV with V = W, Z) in proton-proton collisions at the LHC at $\sqrt{s}=13\text{ TeV}$. The search was performed in final states with two same-sign charged leptons (electrons or muons) plus one or two jets, and three, four, five, or six leptons from WWW, WWZ, WZZ and ZZZ decays, with a data sample corresponding to an integrated luminosity of 137 fb -1 collected by the CMS experiment during 2016-2018. The observed (expected) significance of the combined VVV production is 5.7 (5.9) standard deviations, and the production cross section is measured to be 1010$^{+210}_{-200}$(stat) $^{+150}_{-120}$(syst) fb, corresponding to a signal strength of 1.02$^{+0.26}_{-0.23}$. We also found evidence for WWW and for WWZ production, with observed significances of 3.3 and 3.4 standard deviations, respectively. The measured production cross sections for individual VVV processes are also reported. The establishment of VVV production opens a new program of many standard model studies (such as gauge-gauge and Higgs-gauge couplings), and provides a new tool for many new physics searches (such as anomalous gauge coupling searches, new resonance searches). This thesis also reports a search for long-lived supersymmetry particles decaying to photons in proton-proton collisions at the LHC at $\sqrt{s} = 13 TeV$, with a data sample corresponding to an integrated luminosity of 77.4 fb -1 collected by CMS during 2016-2017. Results are interpreted with a gauge-mediated supersymmetry breaking model, where the long-lived particle is a neutralino and the lightest supersymmetry particle is a gravitino. For neutralino proper decay lengths of 0.1, 1, 10, and 100 m, masses up to 320, 525, 360, and 215 GeV are excluded at 95% confidence level, respectively. This result extends the limits from previous searches by one order of magnitude for the neutralino proper decay length and up to 100 GeV more for the neutralino mass. Motivated by the need for precision timing measurements for long-lived particle searches, as well as for improvements in general object reconstruction performance, the timing performance of two types of sensors are studied in this thesis: one with a Cerium doped Lutetium Yttrium Orthosilicate (LYSO:Ce) crystal as the scintillator and a silicon photomultiplier (SiPM) as the photodetector, another with a Cadmium-Telluride sensor as the active material for a sampling calorimeter. Both setups have been demonstrated with test beams to be able to provide timing measurements of particles with a resolution below 30 ps.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microtron Data Log

The Microtron at Los Alamos National Laboratory (LANL) is a versatile electron accelerator originally designed for medical therapy. Since 2001, it has been used for non-destructive radiographic imaging and research and development applications. Operating at four different energy levels—6, 10, 15, and 20 MeV—the Microtron produces dose rates of approximately 780, 1800, 2700, and 2800 R/min at a distance of one meter from the source, respectively. This high-energy X-ray source enables detailed internal examination of dense and thick objects without causing damage, making it invaluable for various scientific and industrial applications. For instance, LANL’s Microtron has been utilized to study the performance of large-panel cerium-doped lutetium yttrium silicon oxide (LYSO) scintillators, which are essential components in advanced imaging systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biokinetic data and models for occupational intake of lanthanoids

The lanthanoid (or lanthanide) chemical elements comprise fifteen elements with atomic numbers 57 (lanthanum) through 71 (lutetium). This paper reviews data related to the biological behavior of these elements in the human body and proposes biokinetic models for application to occupational intake of radio-lanthanoids. Generic (element-independent) absorption rates from the respiratory and alimentary tracts to blood are proposed. The proposed systemic models are largely generic but include some element-specific parameter values to reflect regular changes with ionic radius in certain aspects of the behavior of the lanthanoids. This work was performed within the internal dosimetry task group (INDOS) of Committee 2 of the International Commission on Radiological Protection (ICRP).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production, Purification, and Applications of a Potential Theranostic Pair: Cobalt-55 and Cobalt-58m

The emerging success of [68Ga/177Lu]Ga/Lu-DOTATATE as a theranostic pair has spurred interest in other isotopes as potential theranostic combinations. Here, we review cobalt-55 and cobalt-58m as a potential theranostic pair. Radionuclidically pure cobalt-55 and cobalt-58m have been produced on small cyclotrons with high molar activity. In vitro, DOTATOC labeled with cobalt has shown greater affinity for SSTR2 than DOTATOC labeled with gallium and yttrium. Similarly, [58mCo]Co-DOTATATE has shown improved cell-killing capabilities as compared to DOTATATE labeled with either indium-111 or lutetium-177. Finally, PET imaging with an isotope such as cobalt-55 allows for image acquisition at much later timepoints than gallium, allowing for an increased degree of biological clearance of non-bound radiotracer. We discuss the accelerator targetry and radiochemistry used to produce cobalt-55,58m, emphasizing the implications of these techniques to downstream radiotracers being developed for imaging and therapy.

60 APPLIED LIFE SCIENCES↗

Design of Monolithic Bi-Layer High-Z PAL-Si Hard X-ray CMOS Image Sensors for Quantum Efficiency Enhancement

This article experimentally investigates the inception of an innovative hard X-ray photon energy attenuation layer (PAL) to advance high-energy X-ray detection (20–50 keV). A bi-layer design with a thin film high-Z PAL on the top and Si image sensor on the bottom has previously demon-strated quantum yield enhancement via computational methods by the principle of photon energy down conversion (PEDC), where high-energy X-ray photon energies are attenuated via inelastic scattering down to ≤10 keV, which is suitable for efficient photoelectric absorption by Si. Quantum yield enhancement has been experimentally confirmed via a preliminary demonstration using PAL-integrated Si-based CMOS image sensors (Si CIS). Furthermore, substituting the high-Z PAL with a lower-Z material—Sn—and alternatively coupling it with a conventional scintillator ma-terial—Lutetium-yttrium oxyorthosilicate (LYSO)—have been compared to demonstrate the most prominent efficacy of monolithic integration of high-Z PAL on Si CIS to detect hard X-rays, paving the way for next-generation high-energy X-ray detection methods.

47 OTHER INSTRUMENTATION↗

The Synthesis and Structure of a Scandium Nitrate Hydroxy-Bridged Dimeric Complex Supported by Bipyridyl Ligands

The current discussion on whether scandium, yttrium and lanthanum should represent Group 3 in the Periodic Table or whether lutetium should replace lanthanum in the group has prompted us to further explore the structural chemistry of the Group 3 elements and compare the coordination numbers and coordination geometries adopted. The steric and electronic properties of the coordinated ligands have a major influence on the structures adopted. We report the synthesis and crystal structure determination of an unusual dinuclear scandium complex [(bipy)(NO 3 ) 2 Sc(µ-OH) 2 Sc(NO 3 ) 2 (bipy)] obtained by the reaction of hydrated scandium nitrate with 2,2'-bipyridyl (bipy) in either ethanol or nitromethane. The crystal structure of the complex shows that the scandium centers are eight coordinate, and the structure obtained contrasts with related complexes found in the lanthanide series [Ln(bipy) 2 (NO 3 ) 3 ] and [Ln(phen) 2 (NO 3 ) 3 ] (phen = phenanthroline) and in [M(terpy)(NO 3 ) 3 ] (M = Sc, Er–Lu), where these complexes are all mononuclear.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗