Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LITHIUM FLUORIDES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Determination of Radiation Energy Response for Thermoluminescent Dosimeter TLD-100: Determination of Organ Dose in Diagnostic Radiology

TLD-100 (thermoluminescent dosimeter) cards (chips) were calibrated using X-rays with energies of 25-250 kV produced by a Cs-137 source. The energy responses of lithium fluoride crystals for different energies of X-rays were studied. QA/QC was then performed in the Albanian Ionizing Radiation Metrology Laboratory. Based on the QA/QC results, the chips were used to study the doses to different organs in diagnostic radiology. Organ dose was evaluated after calculation of e dose in air (Kair), using an ionizing chamber.

61 RADIATION PROTECTION AND DOSIMETRY↗

Glue Film Thickness Measurements by Spectral Reflectance

Spectral reflectance was used to determine the thickness of thin glue layers in a study of the effect of the glue on radiance and reflectance measurements of shocked-tin substrates attached to lithium fluoride windows. Measurements based on profilometry of the components were found to be inaccurate due to flatness variations and deformation of the tin substrate under pressure during the gluing process. The accuracy of the spectral reflectance measurements were estimated to be ±0.5 μm, which was sufficient to demonstrate a convincing correlation between glue thickness and shock-generated light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extracting strength from high pressure ramp-release experiments

Unloading from a plastically deformed state has long been recognized as a sensitive measure of a material's deviatoric response. In the case of a ramp compression and unload, time resolved particle velocity measurements of a sample/window interface may be used to gain insight into the sample material's strength. Unfortunately, measurements of this type are often highly perturbed by wave interactions associated with impedance mismatches. Additionally, wave attenuation, the finite pressure range over which the material elastically unloads, and rate effects further complicate the analysis. Here, we present a methodology that overcomes these shortcomings to accurately calculate a mean shear stress near peak compression for experiments of this type. A new interpretation of the self-consistent strength analysis is presented and then validated through the analysis of synthetic data sets on tantalum to 250 GPa. The synthetic analyses suggest that the calculated shear stresses are within 3% of the simulated values obtained using both rate-dependent and rate-independent constitutive models. Window effects are addressed by a new technique referred to as the transfer function approach, where numerical simulations are used to define a mapping to transform the experimental measurements to in situ velocities. The transfer function represents a robust methodology to account for complex wave interactions and a dramatic improvement over the incremental impedance matching methods traditionally used. The technique is validated using experiments performed on both lithium fluoride and tantalum ramp compressed to peak stresses of 10 and 15 GPa, respectively. In each case, various windows of different shock impedance are used to ensure consistency within the transfer function analysis. The data are found to be independent of the window used and in good agreement with previous results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Spall Strength and Dynamic Yield Stress of Hafnium

The spall strength and dynamic yield stress of polycrystalline hafnium have been measured in a series of plane-wave shock loading experiments using flat sample–transparent window composite targets, with the transparent windows representing polymethyl methacrylate or lithium fluoride plates arranged on the rear side of a hafnium sample. The front side of the target was subjected to shock impact of a copper striker, the rear surface velocity was measured, and the sample was recovered for subsequent metallographic examination. The results were also used for evaluation of the accuracy of spall strength measurements and the analysis of features of high-rate deformation of hafnium.

36 MATERIALS SCIENCE↗

Thermoluminescence dosimetry measurements of brachytherapy sources in liquid water

Radiation therapy dose measurements are customarily performed in liquid water. The characterization of brachytherapy sources is, however, generally based on measurements made with thermoluminescence dosimeters (TLDs), for which contact with water may lead to erroneous readings. Consequently, most dosimetry parameters reported in the literature have been based on measurements in water-equivalent plastics, such as Solid Water. These previous reports employed a correction factor to transfer the dose measurements from a plastic phantom to liquid water. The correction factor most often was based on Monte Carlo calculations. The process of measuring in a water-equivalent plastic phantom whose exact composition may be different from published specifications, then correcting the results to a water medium leads to increased uncertainty in the results. A system has been designed to enable measurements with TLDs in liquid water. This system, which includes jigs to support water-tight capsules of lithium fluoride in configurations suitable for measuring several dosimetric parameters, was used to determine the correction factor from water-equivalent plastic to water. Measurements of several {sup 125}I and {sup 131}Cs prostate brachytherapy sources in liquid water and in a Solid Water phantom demonstrated a correction factor of 1.039{+-}0.005 at 1 cm distance. These measurements are in good agreement with a published value of this correction factor for an {sup 125}I source.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Left-right correlation in coupled F-center defects

This work explores how left-right correlation, a textbook problem in electronic structure theory, manifests in a textbook example of electrons trapped in crystal defects. I show that adjacent F-center defects in lithium fluoride display symptoms of “strong” left-right correlation, symptoms similar to those seen in stretched H{sub 2}. Simulations of UV/visible absorption spectra qualitatively fail to reproduce experiment unless left-right correlation is taken into account. This is of interest to both the electronic structure theory and crystal-defect communities. Theorists have a new well-behaved system to test their methods. Crystal-defect groups are cautioned that the approximations that successfully model single F-centers may fail for adjacent F-centers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sound velocity of tantalum under shock compression in the 18–142 GPa range

Dynamic compression experiments of tantalum (Ta) within a shock pressure range from 18–142 GPa were conducted driven by explosive, a two-stage light gas gun, and a powder gun, respectively. The time-resolved Ta/LiF (lithium fluoride) interface velocity profiles were recorded with a displacement interferometer system for any reflector. Sound velocities of Ta were obtained from the peak state time duration measurements with the step-sample technique and the direct-reverse impact technique. The uncertainty of measured sound velocities were analyzed carefully, which suggests that the symmetrical impact method with step-samples is more accurate for sound velocity measurement, and the most important parameter in this type experiment is the accurate sample/window particle velocity profile, especially the accurate peak state time duration. From these carefully analyzed sound velocity data, no evidence of a phase transition was found up to the shock melting pressure of Ta.

36 MATERIALS SCIENCE↗

Hugoniot Models for Na and LiF from LEOS

In this document, we provide the Hugoniot for sodium from two models: LEOS table L110 and Lynx table 110. We also provide the Hugoniot for lithium fluoride from LEOS (L2240) and Lynx (2240). The Hugoniot pressures are supplied for temperatures between 338.0 and 1.16×10 9 Kelvin and densities between 0.968 and 11.5 g/cc. These LEOS models were developed by the quotidian EOS methodology, which is a widely used and robust method for producing tabular EOS data. Tables list the model data for LEOS 110, Lynx 110, LEOS 2240, and Lynx 2240. The Lynx models follow the same methodology as the LEOS models; however, the Purgatorio average-atom DFT code was used to compute the electron thermal part of the EOS. The models for Lynx are only listed at high compression due to known issues with the Lynx library at lower pressures.

36 MATERIALS SCIENCE↗

Production of excitons in grazing collisions of protons with LiF surfaces: An onion model

In this work we evaluate the production of excitons of a lithium fluoride crystal induced by proton impact in the intermediate and high energy regime (from 100 keV to 1 MeV). A simple model is proposed to account for the influence of the Coulomb grid of the target by dressing crystal ions to transform them in what we call onions. The excited states of these onions can be interpreted as excitons. Within this model, total cross section and stopping power are calculated by using the first Born and the continuum distorted-wave (CDW) eikonal initial-state (EIS) approximations. We found that between 7 and 30 excitons per incident proton are produced in grazing collisions with LiF surfaces, becoming a relevant mechanism of inelastic transitions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Formation of a Thin Luminescent Layer in LiF Crystals under Glow Discharge Radiation

The formation of thin layers of luminescent defects on the faces of planar lithium fluoride crystals located in the positive column and Faraday dark space of a glow gas discharge was studied by time-resolved confocal scanning luminescent microscopy and time-correlated single photon counting. The formation of aggregated color centers in the surface layers of crystals was established using the spectral and kinetic characteristics of luminescence appearing after irradiation. The role of gas discharge electrons, ions, and photons in the defect formation mechanism was considered. The defects were shown to be formed under the influence of vacuum ultraviolet (VUV) photons. The VUV radiation intensity distribution in the discharge gap was measured by the method of thermostimulated luminescence. The main source of this radiation was the anodic and cathodic voltage drop regions in a glow discharge.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pure LiF nanophosphors for high exposures of gamma-rays

Nanocrystalline lithium fluoride (LiF) phosphors have been prepared by the chemical co-precipitation method at different pH values (7.0, 8.0, 9.0 and 10.00). The formation of nanocrystalline structure has been confirmed by X-ray diffraction and transmission electron microscope. Thermoluminescence (TL) properties of LiF phosphors irradiated with gamma rays at different doses of 10 Gy - 70 kGy have been further studied. The analysis of TL glow curve revealed the existence of three well resolved glow peaks, first low temperature peak at around 82 deg. C, second at 125 deg. C and third one at higher temperature around 303 deg. C. The LiF nano-crystallites synthesized at 8.00 pH with maximum TL sensitivity at studied gamma doses ranging from threshold to high exposures are potential candidate for dosimetry applications.

36 MATERIALS SCIENCE↗

Plasma-accelerated flyer-plates for equation of state studies

We report on a new technique to accelerate flyer-plates to high velocities ({approx}5 km/s). In this work, a strong shock is created through direct laser ablation of a thin polyimide foil. Subsequent shock breakout of that foil results in the generation of a plasma characterized by a smoothly increasing density gradient and a strong forward momentum. Stagnation of this plasma onto an aluminum foil and the resultant momentum transfer accelerates a thin aluminum flyer-plate. The aluminum flyer-plate is then accelerated to a peak velocity of {approx}5 km/s before impact with a transparent lithium fluoride (LiF) window. Simulations of the stagnating plasma ramp compression and wave reverberations within the flyer-plate suggest that the temperature at the flyer-plate impact surface is elevated by less than 50 Degree-Sign C. Optical velocimetry is used to measure the flyer-plate velocity and impact conditions enabling the shocked refractive index of LiF to be determined. The results presented here are in agreement with conventional flyer-plate measurements validating the use of plasma-accelerated flyer-plates for equation of state and impact studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High temperature thermographic measurements of laser heated silica

In situ spatial and temporal surface temperature profiles of CO{sub 2} laser-heated silica were obtained using a long wave infrared (LWIR) HgCdTe camera. Solutions to the linear diffusion equation with volumetric and surface heating are shown to describe the temperature evolution for a range of beam powers, over which the peak surface temperature scales linearly with power. These solutions were used with on-axis steady state and transient experimental temperatures to extract thermal diffusivity and conductivity for a variety of materials, including silica, spinel, sapphire, and lithium fluoride. Experimentally-derived thermal properties agreed well with reported values and, for silica, thermal conductivity and diffusivity are shown to be approximately independent of temperature between 300 and 2800K. While for silica our analysis based on a temperature independent thermal conductivity is shown to be accurate, for other materials studied this treatment yields effective thermal properties that represent reasonable approximations for laser heating. Implementation of a single-wavelength radiation measurement in the semi-transparent regime is generally discussed, and estimates of the apparent temperature deviation from the actual outer surface temperature are also presented. The experimental approach and the simple analysis presented yield surface temperature measurements that can be used to validate more complex physical models, help discriminate dominant heat transport mechanisms, and to predict temperature distribution and evolution during laser-based material processing.

42 ENGINEERING↗

Thermoluminescence of Eu activated LiF nanophosphors

Nanocrystalline lithium fluoride (LiF) phosphors prepared by the chemical co-precipitation method at 8.00 pH value have been activated with Eu (0.01, 0.03, 0.07 and 0.1%nt;) as single dopants. The formation of nanocrystalline structure has been confirmed by X-ray diffraction. Thermolumniscence (TL) properties of LiF: Eu nano-phosphors irradiated with gamma rays at different doses of 100 Gy - 10 kGy have been further studied. There is only one main glow peak at around 122 deg. C; which shifts to higher temperature with an increase in doping concentration at all studied irradiation doses. However, the glow peak shifts to lower temperature with an increase in irradiation dose from 100 Gy to 10 kGy. The LiF nano-crystallites synthesized at 8.00 pH and activated with 0.03%nt; Eu are found to have maximum TL sensitivity at studied gamma doses.

36 MATERIALS SCIENCE↗

The role of a LiF layer on the performance of poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate)/Si organic-inorganic hybrid solar cells

We report an ultra-thin layer of lithium fluoride (LiF) between silicon (Si) and aluminum (Al) in a Si/poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) hybrid solar cell which resulted in a power conversion efficiency (PCE) of 11.09%. The insertion of a thin layer of LiF improved the contact between Si and Al, which decreased the contact resistance from 5.4 × 10{sup −1} Ω cm{sup 2} to 2.6 × 10{sup −2} Ω cm{sup 2}. Also, the electron transport from Si to Al was improved and charge carrier recombination was suppressed. As a result, the short circuit current density, the open circuit voltage, and the fill factor were all improved with the presence of the LiF layer. The solar cell with the LiF/Al bilayer as a cathode displayed a 14.45% enhancement on PCE when compared with the device using pristine Al as a cathode.

14 SOLAR ENERGY↗

SU-F-P-47: Estimation of Skin Dose by Performing the Measurements On Cylindrical Phantom

Purpose: To evaluate the skin dose by performing the measurements on cylindrical phantom with 6X beam. Methods: A cylindrical phantom was used to best model a patient surface. The source to surface distance (SSD) was 100 cm at phantom surface along central axis (CAX). The EBT2 films were cut into 2×2 cm2 pieces. Each piece of film was placed at CAX on phantom surface for each measurement at 0°, 15°, 30°, 45°, 60°, 75°, and 90° gantry angles for field sizes of 5×5, 10×10, 15×15, and 20×20 cm{sup 2} respectively. One hundred monitor units (MU) with 6X beam were delivered for each set up. Similarly, the measurements were repeated using lithium fluoride (LiF) thermoluminescent dosimeter (TLD) chips (1X1X1 mm{sup 3}). Two TLD chips were placed for each gantry angle and field size. The calibration curves were produced for both film and TLD. The computed tomography (CT) was also performed on the same cylindrical phantom and dose was evaluated at the phantom surface using Eclipse treatment planning system ( AAA algorithm) for skin dose comparison. Results: Data showed small differences at smaller angles among EBT2, TLD and Eclipse treatment planning system. But Eclipse treatment planning system under estimated the skin dose between 20% and 50% at larger gantry angles (between 40° and 80°) at all field sizes before dose differences began to converge. Conclusion: Given this data, we can conclude that Eclipse treatment planning system under estimated the dose especially between 40 and 80 degrees of obliquity compared to the measurements results. Ideally, this study can be applied largely to head and neck patients where contours differ drastically and where skin dose is paramount.

60 APPLIED LIFE SCIENCES↗

Dramatic enhancement of fullerene anion formation in polymer solar cells by thermal annealing: Direct observation by electron spin resonance

Using electron spin resonance (ESR), we clarified the origin of the efficiency degradation of polymer solar cells containing a lithium-fluoride (LiF) buffer layer created by a thermal annealing process after the deposition of an Al electrode (post-annealing). The device structure was indium-tin-oxide/ poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate)/poly (3-hexylthiophene):phenyl-C{sub 61}-butyric acid methyl ester (P3HT:PCBM)/LiF/Al. Three samples consisting of quartz/P3HT:PCBM/LiF/Al, quartz/P3HT:PCBM/Al, and quartz/PCBM/LiF/Al were investigated and compared. A clear ESR signal from radical anions on the PCBM was observed after LiF/Al was deposited onto a P3HT:PCBM layer because of charge transfer at the interface between the PCBM and the LiF/Al, which indicated the formation of PCBM{sup −}Li{sup +} complexes. The number of radical anions on the PCBM was enhanced remarkably by the post-annealing process; this enhancement was caused by the surface segregation of PCBM and by the dissociation of LiF at the Al interface by the post-annealing process. The formation of a greater number of anions enhanced the electron scattering, decreased the electron-transport properties of the PCBM molecules, and caused an energy-level shift at the interface. These effects led to degradation in the device performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-308: Systematic Characterization of the Energy Response of Different LiF TLD Crystals for Dosimetry Applications

Purpose: The thermoluminiscense dosimeters (TLDs) are widely used in personal and clinical dosimetry due to its small size, good sensitivity and tissue equivalence, among other advantages. This study presents the characterization of Lithium Fluoride based TLDs, in terms of their absorbed dose response to successive irradiation cycles in a broad range of beam energies, measured under reference conditions. Methods: Four types of Harshaw TLD chips were used: TLD-100, TLD-600 TLD-700 and 100-H. They were irradiated with 10 photon beams of different energy spectrums, from 28 kVp to 18MV (in 30 consecutive cycles for 6 and 18 MV). Results: It was found that the response of the dosimetric system was stabilized (less than ±3%) after 10 cycles for TLD-600 and TLD-700. In the case of TLD-100 and TLD-100H this dependence was not observed. A decreased response to increasing beam energy in terms of absorbed dose to water was observed, as expected, except for TLD-100H which showed the opposite behavior. The less energy dependent detector was the TLD-100H exhibiting a maximum deviation of 12%. The highest variation observed was 33% for TLD-100. The study allowed the determination of calibration factors in absorbed dose for a wide range of energies and materials for different dosimetric applications, such as in-vivo dosimetry during imaging and radiotherapy. Conclusion: The study allowed the determination of calibration factors in absorbed dose for a wide range of energies and materials for different dosimetric applications, such as in-vivo dosimetry during imaging and radiotherapy.

60 APPLIED LIFE SCIENCES↗