Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIFE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Status of the GERDA Phase II upgrade

The GERDA experiment is designed to search for neutrinoless double beta (0νββ) decay of {sup 76}Ge. In Phase I of the experiment a background index of 10{sup −2} cts/(keV·kg·yr) was reached. A lower limit on the half-life of the 0νββ decay of {sup 76}Ge was set to 2.1·10{sup 25} yr (at 90% C.L.). The aim of Phase II is to reach a sensitivity of the half-life of about 10{sup 26} yr. To increase the exposure thirty new Broad Energy Germanium (BEGe) detectors have been produced. These detectors are distinct for their improved energy resolution and enhanced pulse shape discrimination of signal from background events. Further background reduction will be reached by a light instrumentation to read out argon scintillation light. In April 2015 the light instrumentation together with eight BEGe detectors has been successfully deployed in the GERDA cryostat. In a commissioning run it was shown that two of the major background components, external γ-rays from {sup 214}Bi and {sup 208}Tl decays, were suppressed up to two orders of magnitude. We are confident to reach a background index of 10{sup −3} cts/(keV·kg·yr) which is the design goal for GERDA Phase II.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Muon tagging with flash ADC waveform baselines

Here, this manuscript describes an innovative method to tag muons using the baseline information of the Flash ADC (FADC) waveform of PMTs in the JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment. The experiment is designed to search for evidence of sterile neutrinos, and a reliable method for muon tagging is an essential component for background rejection because the detector is located above ground, on the 3rd floor of the J-PARC Material and Life Science Experimental Facility (MLF). Cosmogenic muons that stop within the detector volume and produce a Michel electron are a particularly important background that must be rejected for our sterile neutrino search. Utilizing this innovative method, more than 99.8 % of Michel electrons can be rejected even without using information from the detector’s veto region PMTs. This technique can be employed by any experiments which uses a similar detector configuration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Half-life of Si-32 from tandem-accelerator mass spectrometry

A newly developed mass-spectrometry technique employing a tandem Van de Graaff accelerator together with a special beam-transport system and heavy-ion detector has been used to determine the half-life of Si-32. The result obtained, 108 plus or minus 18 yr, disagrees with the accepted value of 330 plus or minus 40 yr. The implications of the new half-life of Si-32, which is used for dating studies, are discussed.

Elmore, D.↗

Investigation of {beta}{beta} decay in {sup 150}Nd and {sup 148}Nd to the excited states of daughter nuclei

Double beta decay of {sup 150}Nd and {sup 148}Nd to the excited states of daughter nuclei have been studied using a 400 cm{sup 3} low-background HPGe detector and an external source consisting of 3046 g of natural Nd{sub 2}O{sub 3} powder. The half-life for the two-neutrino double beta decay of {sup 150}Nd to the excited 0{sub 1}{sup +} state in {sup 150}Sm is measured to be T{sub 1/2}=[1.33{sub -0.23}{sup +0.36}(stat){sub -0.13}{sup +0.27}(syst)]x10{sup 20} yr. For other (0{nu}+2{nu}) transitions to the 2{sub 1}{sup +}, 2{sub 2}{sup +}, 2{sub 3}{sup +}, and 0{sub 2}{sup +} levels in {sup 150}Sm, limits are obtained at the level of {approx}(2-8)x10{sup 20} yr. In the case of {sup 148}Nd only limits for the (0{nu}+2{nu}) transitions to the 2{sub 1}{sup +}, 0{sub 1}{sup +}, and 2{sub 2}{sup +} excited states in {sup 148}Sm were obtained and are at the level of {approx}(4-8)x10{sup 20} yr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-G-204-03: Photon-Counting Hexagonal Pixel Array CdTe Detector: Optimal Resampling to Square Pixels

Purpose: Detectors with hexagonal pixels require resampling to square pixels for distortion-free display of acquired images. In this work, the presampling modulation transfer function (MTF) of a hexagonal pixel array photon-counting CdTe detector for region-of-interest fluoroscopy was measured and the optimal square pixel size for resampling was determined. Methods: A 0.65mm thick CdTe Schottky sensor capable of concurrently acquiring up to 3 energy-windowed images was operated in a single energy-window mode to include ≥10 KeV photons. The detector had hexagonal pixels with apothem of 30 microns resulting in pixel spacing of 60 and 51.96 microns along the two orthogonal directions. Images of a tungsten edge test device acquired under IEC RQA5 conditions were double Hough transformed to identify the edge and numerically differentiated. The presampling MTF was determined from the finely sampled line spread function that accounted for the hexagonal sampling. The optimal square pixel size was determined in two ways; the square pixel size for which the aperture function evaluated at the Nyquist frequencies along the two orthogonal directions matched that from the hexagonal pixel aperture functions, and the square pixel size for which the mean absolute difference between the square and hexagonal aperture functions was minimized over all frequencies up to the Nyquist limit. Results: Evaluation of the aperture functions over the entire frequency range resulted in square pixel size of 53 microns with less than 2% difference from the hexagonal pixel. Evaluation of the aperture functions at Nyquist frequencies alone resulted in 54 microns square pixels. For the photon-counting CdTe detector and after resampling to 53 microns square pixels using quadratic interpolation, the presampling MTF at Nyquist frequency of 9.434 cycles/mm along the two directions were 0.501 and 0.507. Conclusion: Hexagonal pixel array photon-counting CdTe detector after resampling to square pixels provides high-resolution imaging suitable for fluoroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a CdTe semiconductor based compact gamma camera for sentinel lymph node imaging

Purpose: The authors assembled a prototype compact gamma-ray imaging probe (MediPROBE) for sentinel lymph node (SLN) localization. This probe is based on a semiconductor pixel detector. Its basic performance was assessed in the laboratory and clinically in comparison with a conventional gamma camera. Methods: The room-temperature CdTe pixel detector (1 mm thick) has 256x256 square pixels arranged with a 55 {mu}m pitch (sensitive area 14.08x14.08 mm{sup 2}), coupled pixel-by-pixel via bump-bonding to the Medipix2 photon-counting readout CMOS integrated circuit. The imaging probe is equipped with a set of three interchangeable knife-edge pinhole collimators (0.94, 1.2, or 2.1 mm effective diameter at 140 keV) and its focal distance can be regulated in order to set a given field of view (FOV). A typical FOV of 70 mm at 50 mm skin-to-collimator distance corresponds to a minification factor 1:5. The detector is operated at a single low-energy threshold of about 20 keV. Results: For {sup 99m}Tc, at 50 mm distance, a background-subtracted sensitivity of 6.5x10{sup -3} cps/kBq and a system spatial resolution of 5.5 mm FWHM were obtained for the 0.94 mm pinhole; corresponding values for the 2.1 mm pinhole were 3.3x10{sup -2} cps/kBq and 12.6 mm. The dark count rate was 0.71 cps. Clinical images in three patients with melanoma indicate detection of the SLNs with acquisition times between 60 and 410 s with an injected activity of 26 MBq {sup 99m}Tc and prior localization with standard gamma camera lymphoscintigraphy. Conclusions: The laboratory performance of this imaging probe is limited by the pinhole collimator performance and the necessity of working in minification due to the limited detector size. However, in clinical operative conditions, the CdTe imaging probe was effective in detecting SLNs with adequate resolution and an acceptable sensitivity. Sensitivity is expected to improve with the future availability of a larger CdTe detector permitting operation at shorter distances from the patient skin.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Assessment of Sunlight Impinging on OSIRIS-REx OCAMS PolyCam, OTES, and IMU-Sunshade MLI Blankets in Flight

The NASA Origins, Spectral Interpretation, Resource Identification, Security, Regolith Explorer (OSIRIS-REx) spacecraft was successfully launched into orbit on September 8, 2016. It is traveling to a near-Earth asteroid (101955) Bennu, study it in detail, and bring back a pristine sample to Earth for scientific analyses. At the Outbound Cruise nominal spacecraft attitude, with Sun on +X, sunlight impinges on the OSIRIS-REx camera suite (OCAMS) PolyCam sunshade multilayer insulation (MLI) with microporous black polytetrafluoroethylene (PTFE), a portion of the PolyCam optics support tube (MLI with germanium black Kapton (GBK)), a portion of the OSIRIS-REx Thermal Emission Spectrometer (OTES) sunshade (MLI with GBK), the Inertia Measurement Unit (IMU) sunshade (MLI with GBK), and the OSIRIS-REx Laser Altimeter (OLA) sunshade (MLI with GBK). Sunlight is reflected or scattered by the above MLIs to the other components on the forward (+Z) deck. It illuminates the forward deck. A detailed thermal assessment on the solar impingement has been performed for the Proximity Ops at the asteroid, Touch-and-Go (TAG) sample acquisition, and Return Cruise mission phases.The OSIRIS-REx Outbound Cruise flight temperature telemetry and USM_3_DPC_0_CURRENT flight currenttelemetry data have been analyzed. It is evident that at the nominal Outbound Cruise spacecraft Sun-pointing attitude(i.e., Sun on +X), sunlight impinging on the PolyCam, OTES, IMU-sunshade and OLA-sunshade MLIs is reflected orscattered to the forward deck and components on the forward deck. It illuminates the forward deck. The StowCam imageof Day 265 2016 also provided an evidence. The reflected or scattered sunlight cause warming to the forward deck andcomponents on its +Z side. It may also contribute to degradation of thermal coatings over the mission life. It is a factorthat the OVIRS detector operating temperature exceeds the 105K maximum AFT limit. The OVIRS PrincipalInvestigator indicated that it is not optimum but acceptable for science. With exception of the OVIRS detector, thecorrelated flight system thermal model predictions for the components on the forward deck have adequate margins in theProximity Ops, TAG and Return Cruise phases. The margins are expected to cover the warming caused by the solarimpingement and the contribution to degradation of thermal coatings. The solar impingement is not expected to be athermal risk to the OSIRIS-REx mission. The second SRC Optical Properties characterization will be repeated in theReturn Cruise to provide a good characterization of any changes in optical properties that might have occurred duringthe TAG, or during several years in space. If the SRC battery runs much warmer than that of the first characterization inthe Outbound Cruise, it will be necessary to make some changes to the SRC Release timeline to assure the SRC batterytemperature are within limits. If GBK, instead of microporous black PTFE, were used on the PolyCam sunshade MLI,much more sunlight would have been reflected or scattered to the forward deck and components on its +Z side.Microporous black PTFE should be considered to mitigate the optical and thermal issues of sunlight reflected/scatteredby MLI blankets in future missions.

Choi, Michael K.↗

Design of the cryogenic system for the SAFIRE instrument

One of the primary goals of the NASA Mission to Planet Earth is to improve understanding of the ozone chemistry of the atmosphere over an extended period of time. The Spectroscopy of the Atmosphere using Far Infrared Emission (SAFIRE) instrument is being developed to conduct, for the first time, global measurements of the key ozone chemistry constituents in both the mid- and far-infrared spectral regions. Such remote, long-term observations are made possible by the recent development of compact long-life hybrid cryogenic dewars which are necessary to cool the sensitive detectors to the 3-4 K range. The success of this hybrid concept is based on the use of long-life Stirling cycle cryocoolers to intercept parasitic heat from the internal radiation shields of the superfluid helium dewar. Extensive system trade studies are required to optimize the mass, power, and lifetime of these space-borne cryogenic systems. The SAFIRE Cryogenic Subsystem is described, including the thermal performance trades leading to the chosen system configuration and the important dewar/cryocooler interface issues.

Lee, J. H.↗

Search for {beta}{sup +}EC and ECEC processes in {sup 112}Sn

Limits on {beta}{sup +}EC (here EC denotes electron capture) and ECEC processes in {sup 112}Sn have been obtained using a 380 cm{sup 3} HPGe detector and an external source consisting of 53.355 g enriched tin (94.32% of {sup 112}Sn). A limit with 90% C.L. on the {sup 112}Sn half-life of 4.7x10{sup 20} y for the ECEC(0{nu}) transition to the 0{sub 3}{sup +} excited state in {sup 112}Cd (1871.0 keV) has been established. This transition is discussed in the context of a possible enhancement of the decay rate by several orders of magnitude given that the ECEC(0{nu}) process is nearly degenerate with an excited state in the daughter nuclide. Prospects for investigating such a process in future experiments are discussed. The limits on other {beta}{sup +}EC and ECEC processes in {sup 112}Sn were obtained on the level of (0.6-8.7)x10{sup 20} y at the 90% C.L.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Metrological Determination of Natural Radioactive Isotopes {sup 226}Ra, {sup 228}Ra and {sup 210}Pb by Means of Ge Detector

A metrological method to determine the activity per mass unity (activity concentration) of {sup 226}Ra and {sup 210}Pb ({sup 238}U decay series) and {sup 228}Ra ({sup 232}Th series) by gamma-ray spectrometers based on hyper-pure coaxial germanium detector was developed. In the soil the {sup 22}Ra (half-life = 1600 years) exhibits the same level of radioactivity as {sup 238}U (half-life 4.5x10{sup 9} years) because of a natural phenomenon called secular equilibrium. {sup 226}Ra decays into {sup 222}Rn (half-life = 3.8 days), a radioactive inert gas. After several days, the {sup 222}Rn naturally decays to {sup 218}Po (half-life = 3 minutes), where finally {sup 210}Pb (half-life = 22 years) is produced. The metrological capability of high-resolution gamma-ray spectrometry for naturally occurring radionuclides at environmental levels is showed, with emphasis on the use of 2 mL standard sources volume in a glass ampoule. Source preparation and calibration procedures are described. Radionuclide standards in an activity range of 10 to 250 Bq/g were produced which can be applied in a variety of environmental sample analysis (water, plant material, sediment, etc.). Uncertainties for {sup 226}Ra and {sup 210}Pb around 3% (k = 1) were obtained.

54 ENVIRONMENTAL SCIENCES↗

Infrared focal plane performance in the South Atlantic anomaly

Proton-induced pulse height distributions (PHD's) in Si:XX detectors were studied analytically and experimentally. In addition, a preliminary design for a flight experiment to characterize the response of Si:XX detectors to the trapped proton environment and verify PHD models was developed. PHD's were computed for two orbit altitudes for a variety of shielding configurations. Most of the proton-induced pulses have amplitudes less that about 3.5 x 10(exp 5) e-h pairs. Shielding has a small effect on the shape of the PHD's. The primary effect of shielding is to reduce the total number of pulses produced. Proton-induced PHD's in a Si:Sb focal plane array bombarded by a unidirectional 67-MeV beam were measured. The maximum pulse height recorded was 6 x 10(exp 5) pairs. The distribution had two peaks: the larger peak corresponded to 3.8 x 10(exp 5) pairs and the smaller peak to 1.2 x 10(exp 5) pairs. The maximum pulse height and the larger peak are within a factor of two of predicted values. The low-energy peak was not expected, but is believed to be an artifact of inefficient charge collection in the detector. The planned flight experiment will be conducted on a Space Shuttle flight. Lockheed's helium extended life dewar (HELD) will be used to provide the required cryogenic environment for the detector. Two bulk Si:Sb arrays and two Si:As impurity band conduction arrays will be tested. The tests will be conducted while the Space Shuttle passes through the South Atlantic Anomaly. PHD's will be recorded and responsivity changes tracked. This experiment will provide a new database on proton-induced PHD's, compare two infrared detector technologies in a space environment, and provide the data necessary to validate PHD modeling.

Junga, Frank A.↗

NIAC Phase-2 Final Report for Astrophysics and Technical Lab Studies of a Solar Neutrino Spacecraft Detector

The Sun provides all the energy that our planet needs for life and has been doing so for five billion years. Understanding our Sun and its interior is one of the major goals of the NASA Science program. Still this is a very difficult task because very little makes it directly out of the Sun’s interior. The energy we see today, that warms the Earth, was made 50,000 to 80,000 years ago and is only now coming to the surface to make light. However, neutrinos penetrate matter almost without interaction and make it to Earth in only eight minutes from creation. Since neutrinos interact only weakly they are hard to detect; never-the-less within the last ten years neutrino detectors on Earth have started to reliably detect neutrinos from the fusion reactions in the interior of the Sun and scientists have started to use this information to investigate the Sun’s nuclear furnace. Changes in solar neutrino flux make it advantageous to take a neutrino detector into space since the solar neutrino intensity changes dramatically as the inverse square of the distance from the Sun, by five orders of magnitude when going from the Earth to the Sun. Launch of a neutrino detector into space toward the Sun will: a) aim to significantly increase the neutrino flux 10,000x allowing for a smaller detector which improves detector energy resolution and performance, b) attempt to completely eliminate background terrestrial neutrino sources for improved measurement accuracy, and c) conduct unique science experiments near the Sun not achievable with much larger detectors on the Earth. NASA's interest in deep space exploration has been a key factor in its unmanned spacecraft development and launch of exploration science satellites and spacecraft. NASA has done exceptional experiments in space where science benefits from the unique platform of spacecraft that provides unprecedented views. For example, the Hubble Space Telescope is really a small and very common instrument, but when it is put into an orbit high above the Earth, it becomes one of the most powerful optical observatories man has ever made. Moving neutrino observations to space is the next obvious step. The concept of putting a neutrino detector in close orbit of the sun is completely unexplored and innovative. Its scientific return is to vastly enhance the understanding of the solar interior which is a NASA major goal as stated in the decadal survey. Preliminary calculations show that such a spacecraft if properly shielded, can operate in this environment both taking data of neutrino interactions which can be distinguished from random background rates of solar Electromagnetic emissions, Galactic charged cosmic-ray, and gamma-rays by using a double pulsed signature. The NIAC Phase-1 simulations have shown this idea to be very successful in eliminating background and identifying the neutrino interaction signal, hence this spacecraft detector concept once demonstrated to be Technical Readiness Level 7 and flight mission-ready would enable a whole new type of mission to explore and study our Sun, in details that could neither be done with the largest neutrino detectors on Earth nor other types of space-craft measurements that are not using neutrino detection. Our goal in this NIAC Phase-2 was to take the detector simulation ideas and construct a prototype for testing in the lab with tagged sources to evaluate and demonstrate that the performance in the simulations are borne out by a prototype.

Neutrino↗

Search for two-neutrino double-beta decay of 136 Xe to the $0$$^{+}_{1}$ excited state of 136 Ba with the complete EXO-200 dataset*

A new search for two-neutrino double-beta (2νββ) decay of 136 Xe to the $0$$^{+}_{1}$ excited state of 136 Ba is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the addition of the Phase II dataset taken with an upgraded detector, the median 90% confidence level half-life sensitivity of 2νββ decay to the $0$$^{+}_{1}$ state of 136 Ba is 2.9 x 10 24 yr using a total 136 Xe exposure of 234.1 kg yr. Furthermore, no statistically significant evidence for 2νββ decay to the $0$$^{+}_{1}$ state is observed, leading to a lower limit of $T$$^{2v}_{1/2}$(0 + → $0$$^{+}_{1}$) > 1.4 x 10 24 yr at 90% confidence level, improved by 70% relative to the current world's best constraint.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Localization of fluorescent targets in deep tissue with expanded beam illumination for studies of cancer and the brain

Imaging fluorescence through millimeters or centimeters of tissue has important in vivo applications, such as guiding surgery and studying the brain. Often, the important information is the location of one of more optical reporters, rather than the specifics of the local geometry, motivating the need for a localization method that provides this information. We present an optimization approach based on a diffusion model for the fast localization of fluorescent inhomogeneities in deep tissue with expanded beam illumination that simplifies the experiment and the reconstruction. We show that the position of a fluorescent inhomogeneity can be estimated while assuming homogeneous tissue parameters and without having to model the excitation profile, reducing the computational burden and improving the utility of the method. We perform two experiments as a demonstration. First, a tumor in a mouse is localized using a near infrared folate-targeted fluorescent agent (OTL38). This result shows that localization can quickly provide tumor depth information, which could reduce damage to healthy tissue during fluorescence-guided surgery. Second, another near infrared fluorescent agent (ATTO647N) is injected into the brain of a rat, and localized through the intact skull and surface tissue. This result will enable studies of protein aggregation and neuron signaling.

60 APPLIED LIFE SCIENCES↗

Measuring the β-decay Properties of Neutron-rich Exotic Pm, Sm, Eu, and Gd Isotopes to Constrain the Nucleosynthesis Yields in the Rare-earth Region

Abstract The β -delayed neutron-emission probabilities of 28 exotic neutron-rich isotopes of Pm, Sm, Eu, and Gd were measured for the first time at RIKEN Nishina Center using the Advanced Implantation Detector Array (AIDA) and the BRIKEN neutron detector array. The existing β -decay half-life ( T 1/2 ) database was significantly increased toward more neutron-rich isotopes, and uncertainties for previously measured values were decreased. The new data not only constrain the theoretical predictions of half-lives and β -delayed neutron-emission probabilities, but also allow for probing the mechanisms of formation of the high-mass wing of the rare-earth peak located at A ≈ 160 in the r -process abundance distribution through astrophysical reaction network calculations. An uncertainty quantification of the calculated abundance patterns with the new data shows a reduction of the uncertainty in the rare-earth peak region. The newly introduced variance-based sensitivity analysis method offers valuable insight into the influence of important nuclear physics inputs on the calculated abundance patterns. The analysis has identified the half-lives of 168 Sm and of several gadolinium isotopes as some of the key variables among the current experimental data to understand the remaining abundance uncertainty at A = 167–172.

79 ASTRONOMY AND ASTROPHYSICS↗

A Radon Progeny Deposition Model

The next generation low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly {sup 222}Rn) and its subsequent progeny present in an experiment are potential backgrounds, also problematic is the deposition of radon progeny on detector materials. Exposure to radon at any stage of assembly of an experiment can result in surface contamination by progeny supported by the long half life (22 y) of {sup 210}Pb on sensitive locations of a detector. An understanding of the potential surface contamination from deposition will enable requirements of radon-reduced air and clean room environments for the assembly of low background experiments. It is known that there are a number of environmental factors that govern the deposition of progeny onto surfaces. However, existing models have not explored the impact of some environmental factors important for low background experiments. A test stand has been constructed to deposit radon progeny on various surfaces under a controlled environment in order to develop a deposition model. Results from this test stand and the resulting deposition model are presented.

54 ENVIRONMENTAL SCIENCES↗