Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LANDMARK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Autonomous precision landing using terrain-following navigation

Terrain-following navigation studies that have been done over the past two years in the navigation system section at JPL are described. A descent to Mars scenario based on Mars Rover and Sample Return mission profiles is described, and navigation and image processing issues pertaining to descent phases where landmark picture can be obtained are examined. A covariance analysis is performed to verify that landmark measurements from a terrain-following navigation system can satisfy precision landing requirements. Image processing problems involving known landmarks in actual pictures are considered. Mission design alternatives that can alleviate some of these problems are suggested.

Vaughan, R. M.↗

Estimation of the absolute position of mobile systems by an optoelectronic processor

A method that determine the absolute position of a mobile system with a hybrid optoelectronic processor has been developed. Position estimates are based on an analysis of circular landmarks that are detected by a TV camera attached to the mobile system. The difference between the known shape of the landmark and its image provides the information needed to determine the absolute position of the mobile system. For robust operation, the parameters of the landmark image are extracted at high speeds using an optical processor that performs an optical Hough transform. The coordinates of the mobile system are computed from these parameters in a digital co-processor using fast algorithms. Different sources of position estimation errors have also been analyzed, and consequent algorithms to improve the navigation performance of the mobile system have been developed and evaluated by both computer simulation and experiments.

Feng, Liqiang↗

Autonomous planetary landing guidance by optical correlation

We describe our planned use of optical correlation in landmark navigation associated with planetary landing. Standard correlation provides 'pointing-to' information, giving the vector to the landmark from the spacecraft in the spacecraft frame. The synthetic estimation filter (SEF) provides 'pointing-from' information, estimating the vector from the landmark to the spacecraft. Digital and optical SEFs were constructed and compared using a Martian-like 3D modelboard to provide test images. The digital SEF worked reasonably well, but the optical SEF did not perform as expected. The optical SEF was implemented with a liquid crystal television (LCTV) correlator that had been used successfully in previous SEF experiments using a spacecraft model. The results suggest the SLM model for the LCTV needs further refinements. Both the digital and optical filter provided good pointing-to results. We did not plot the correlation surface for the digital SEF response, and though it is less sharp than the POF, it had only a one-pixel variation in the peak location. Surface plots for the conventional optical phase-only filter produced a correlation peak that was sharp enough to be located within two pixels.

Knopp, Jerome↗

Training, transfer, and retention of three-dimensional spatial memory in virtual environments

Human orientation requires one to remember and visualize spatial arrangements of landmarks from different perspectives. Astronauts have reported difficulties remembering relationships between environmental landmarks when imagined in arbitrary 3D orientations. The present study investigated the effects of strategy training on humans' 1) ability to infer their orientation from landmarks presented ahead and below, 2) performance when subsequently learning a different array, and 3) retention of configurational knowledge over time. On the first experiment day, 24 subjects were tested in a virtual cubic chamber in which a picture of an animal was drawn on each wall. Through trial-by-trial exposures, they had to memorize the spatial relationships among the six pictures around them and learn to predict the direction to a specific picture when facing any view direction, and in any roll orientation. Half of the subjects ("strategy group") were taught methods for remembering picture groupings, while the remainder received no such training ("control group"). After learning one picture array, the procedure was repeated in a second. Accuracy (% correct) and response time learning curves were measured. Performance for the second array and configurational memory of both arrays were also retested 1, 7, and 30 days later. Results showed that subjects "learned how to learn" this generic 3D spatial memory task regardless of their relative orientation to the environment, that ability and configurational knowledge was retained for at least a month, that figure rotation ability and field independence correlate with performance, and that teaching subjects specific strategies in advance significantly improves performance. Training astronauts to perform a similar generic 3D spatial memory task, and suggesting strategies in advance, may help them orient in three dimensions.

Non-NASA Center↗

On Target to Mars

This viewgraph presentation reviews the use of Descent Image Motion Estimation System (DIMES) for the descent of a spacecraft onto the surface of Mars. In the past this system was used to assist in the landing of the MER spacecraft. The overall algorithm is reviewed, and views of the hardware, and views from Spirit's descent are shown. On Spirit, had DIMES not been used, the impact velocity would have been at the limit of the airbag capability and Spirit may have bounced into Endurance Crater. By using DIMES, the velocity was reduced to well within the bounds of the airbag performance and Spirit arrived safely at Mars. Views from Oppurtunity's descent are also shown. The system to avoid and detect hazards is reviewed next. Landmark Based Spacecraft Pinpoint Landing is also reviewed. A cartoon version of a pinpoint landing and the various points is shown. Mars s surface has a large amount of craters, which are ideal landmarks . According to literatures on Martian cratering, 60 % of Martian surface is heavily cratered. The ideal (craters) landmarks for pinpoint landing will be between 1000 to 50 meters in diagonal The ideal altitude for position estimation should greater than 2 km above the ground. The algorithms used to detect and match craters are reviewed.

Mars↗

Spacecraft camera image registration

A system for achieving spacecraft camera (1, 2) image registration comprises a portion external to the spacecraft and an image motion compensation system (IMCS) portion onboard the spacecraft. Within the IMCS, a computer (38) calculates an image registration compensation signal (60) which is sent to the scan control loops (84, 88, 94, 98) of the onboard cameras (1, 2). At the location external to the spacecraft, the long-term orbital and attitude perturbations on the spacecraft are modeled. Coefficients (K, A) from this model are periodically sent to the onboard computer (38) by means of a command unit (39). The coefficients (K, A) take into account observations of stars and landmarks made by the spacecraft cameras (1, 2) themselves. The computer (38) takes as inputs the updated coefficients (K, A) plus synchronization information indicating the mirror position (AZ, EL) of each of the spacecraft cameras (1, 2), operating mode, and starting and stopping status of the scan lines generated by these cameras (1, 2), and generates in response thereto the image registration compensation signal (60). The sources of periodic thermal errors on the spacecraft are discussed. The system is checked by calculating measurement residuals, the difference between the landmark and star locations predicted at the external location and the landmark and star locations as measured by the spacecraft cameras (1, 2).

Kamel, Ahmed A.↗

VSLAM and Vision-based Approach and Landing for Advanced Air Mobility

Advanced Air Mobility (AAM) aircraft have many challenges in landing accurately and safely in urban, suburban, and rural environments. Localization in large and open rural environments could utilize GPS, but AAM aircraft in urban environments will encounter GPS degradation. Another challenge involves flight operation time, i.e., flying during the day or at night. There are different guidelines, landmarks, and landing light configurations at runways, heliports, and vertiports for daytime and nighttime applications. Tailoring feature detection methods for AAM approach and landing during the day and night pose different issues and challenges. It is easier to detect edges, lines, and other runway markers during the day than at night. Conversely, it is easier to see landing light configurations and patterns at nighttime than daytime. Consequently, utilizing the same feature detector for daytime and nighttime operations may not be feasible. This paper focuses on a vision-based precision approach and landing (PAL) by comparing ORB SLAM 2, a Vision Simultaneous Localization and Mapping (VSLAM) algorithm, and a novel EKF that combines onboard IMU measurements with coplanar pose from orthography and scaling with iterations (COPOSIT). Conducting unmanned aerial system (UAS) flight tests at NASA Armstrong Flight Research Center (AFRC) with landmarks and fiducials distributed around the landing zone provides a simulated AAM approach and landing data to test vision-based PAL methods to provide Alternative Position, Navigation, and Timing (APNT) solutions for AAM PAL applications. The novel vision-based PAL EKF with IMU and COPOSIT provides accurate state estimation when distributed landmarks and fiducials are in the field of view.

distributed sensing↗

A New Strategy to Land Precisely on the Northern Plains of Mars

During the Phoenix mission landing site selection process, the Mars Reconnaissance Orbiter (MRO) High Resolution Imaging Science Experiment (HiRISE) images revealed widely spread and dense rock fields in the northern plains. Automatic rock mapping and subsequent statistical analyses showed 30-90% CFA (cumulative fractional area) covered by rocks larger than 1 meter in dense rock fields around craters. Less dense rock fields had 5-30% rock coverage in terrain away from craters. Detectable meter-scale boulders were found nearly everywhere. These rocks present a risk to spacecraft safety during landing. However, they are the most salient topographic features in this region, and can be good landmarks for spacecraft localization during landing. In this paper we present a novel strategy that uses abundance of rocks in northern plains for spacecraft localization. The paper discusses this approach in three sections: a rock-based landmark terrain relative navigation (TRN) algorithm; the TRN algorithm feasibility; and conclusions.

pin point landing↗

Management of Operations under Visual Flight Rules in UTM for Disaster Response Missions

The disaster response domain has experienced an increased focus in recent years due to the rise in number and scale of events, lessons learned from past experience, and emerging technologies that make possible a more coordinated and effective response. As part of this focus, JAXA and NASA have been collaborating on the integration of manned and unmanned aircraft in support of disaster response operations through integrated testing of their respective mission planning and optimization system (Disaster Relief Aircraft Information Sharing Network, or D-NET) and an automated UAS traffic management system (e.g., UTM). In 2018, JAXA and NASA jointly participated in a large-scale disaster drill in Japan where the integration of systems was successfully demonstrated through real-time data exchanges, visualization, and decision making as part of the coordinated airspace management of a manned helicopter in VFR conditions and unmanned small UAS operating in common areas. This work details a flight test consisting of two flights that were conducted December 2019 near the Chofu Aerodrome in Tokyo, which focused on the evaluation of pilots operating under Visual Flight Rules (VFR) communicating through D-NET and sharing intent and position information within UTM. This work contributes to defining the necessary requirements for digital coordination between manned and unmanned operations. UTM requires the use of operation volumes, which are spatial and temporal volumes that encompass UAS flight trajectories and account for technical performance errors and deviations due to disturbances (e.g., wind). A series of flights, representing different missions, used landmark-based operation volumes and conformance of the aircraft to those operation volumes were tracked within UTM. Experienced disaster response helicopter pilots provided insight on the development of the operation plans and their usability during disaster response operations. Results from the flight test supported the suggested benefits of using landmarks for planning and positional awareness and highlighted the need for future research in advanced visualization capabilities to support operations that consider both system constraints and flight deck/airspace management interaction.

disaster response↗

Unenhanced Cone Beam Computed Tomography and Fusion Imaging in Direct Percutaneous Sac Injection for Treatment of Type II Endoleak: Technical Note

AimTo evaluate safety, feasibility, technical success, and clinical success of direct percutaneous sac injection (DPSI) for the treatment of type II endoleaks (T2EL) using anatomical landmarks on cone beam computed tomography (CBCT) and fusion imaging (FI).Materials and MethodsEight patients with T2EL were treated with DPSI using CBCT as imaging guidance. Anatomical landmarks on unenhanced CBCT were used for referencing T2EL location in the first five patients, while FI between unenhanced CBCT and pre-procedural computed tomography angiography (CTA) was used in the remaining three patients. Embolization was performed with thrombin, glue, and ethylene–vinyl alcohol copolymer. Technical and clinical success, iodinated contrast utilization, procedural time, fluoroscopy time, and mean radiation dose were registered.ResultsDPSI was technically successful in all patients: the needle was correctly positioned at the first attempt in six patients, while in two of the first five patients the needle was repositioned once. Neither minor nor major complications were registered. Average procedural time was 45 min and the average administered iodinated contrast was 13 ml. Mean radiation dose of the procedure was 60.43 Gy cm{sup 2} and mean fluoroscopy time was 18 min. Clinical success was achieved in all patients (mean follow-up of 36 months): no sign of T2EL was reported in seven patients until last CT follow-up, while it persisted in one patient with stability of sac diameter.ConclusionsDPSI using unenhanced CBCT and FI is feasible and provides the interventional radiologist with an accurate and safe alternative to endovascular treatment with limited iodinated contrast utilization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Four-Dimensional CT-Based Evaluation of Techniques for Gastric Irradiation

Purpose: To evaluate three-dimensional conformal (3D-CRT), intensity-modulated (IMRT) and respiration-gated radiotherapy (RGRT) techniques for gastric irradiation for target coverage and minimization of renal doses. All techniques were four-dimensional (4D)-CT based, incorporating the intrafractional mobility of the target volume and organs at risk (OAR). Methods and Materials: The stomach, duodenal C-loop, and OAR (kidneys, liver, and heart) were contoured in all 10 phases of planning 4D-CT scans for five patients who underwent abdominal radiotherapy. Planning target volumes (PTVs) encompassing all positions of the stomach (PTV{sub allphases}) were generated. Three respiratory phases for RGRT in inspiration and expiration were identified, and corresponding PTV{sub inspiration} and PTV{sub expiration} and OAR volumes were created. Landmark-based fields recommended for the Radiation Therapy Oncology Group (RTOG) 99-04 study protocol were simulated to assess PTV coverage. IMRT and 3D-CRT planning with and without additional RGRT planning were performed for all PTVs, and corresponding dose volume histograms were analyzed. Results: Use of landmark-based fields did not result in full geometric coverage of the PTV{sub allphases} in any patient. IMRT significantly reduced mean renal doses compared with 3D-CRT (15.0 Gy {+-} 0.9 Gy vs. 20.1 Gy {+-} 9.3 Gy and 16.6 Gy {+-} 1.5 Gy vs. 32.6 Gy {+-} 7.1 Gy for the left and right kidneys, respectively; p = 0.04). No significant increase in renal sparing was seen when adding RGRT to either 3D-CRT or IMRT. Tolerance doses to the other OAR were not exceeded. Conclusions: Individualized field margins are essential for gastric irradiation. IMRT plans significantly reduce renal doses, but the benefits of RGRT in gastric irradiation appear to be limited.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Intrafractional Movement and Internal Motion in Radiotherapy of Rectal Cancer Using Megavoltage Computed Tomography

Purpose: The aim of this study was to provide estimates of setup and internal margins of patients treated for rectal carcinoma using helical tomotherapy and to assess possible margin adaptations. Using helical tomotherapy, highly conformal dose distributions can be created, and the integrated megavoltage computed tomography (MVCT) modality allows very precise daily patient positioning. In clinical protocols, however, margins originating from traditional setup procedures are still being applied. This work investigates whether this modality can aid in redefining treatment margins. Methods and Materials: Ten patients who were treated with tomotherapy underwent MVCT scanning before and after 10 treatments. Using automatic registration the necessary setup margin was investigated by means of bony landmarks. Internal margins were assessed by delineating and describing the mesorectal movement. Results: Based on bony landmarks, movement of patients during treatments was limited to 2.45 mm, 1.99 mm, and 1.09 mm in the lateral, longitudinal, and vertical direction, respectively. Systematic errors were limited to <1 mm. Measured movement of the mesorectal space was -1.6 mm ({+-} 4.2 mm) and 0.1 mm ({+-} 4.0 mm) for left and right lateral direction. In the antero-posterior direction, mean shifts were -2 mm ({+-} 6.8 mm) and -0.4 mm ({+-} 3.8 mm). Mean shifts in the cranio-caudal direction were respectively -3.2 mm ({+-} 5.6 mm) and -3.2 mm ({+-} 6.8 mm). Conclusions: The use of the integrated MVCT on the tomotherapy system can minimize the setup margin for rectal cancer, and can also be used to adequately describe the internal margin allowing for direct treatment margin adaptation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FDG-PET-Based Radiotherapy Planning in Lung Cancer: Optimum Breathing Protocol and Patient Positioning-An Intraindividual Comparison

Purpose: Fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography (PET) and PET/computed tomography (CT) are increasingly used for radiotherapy (RT) planning in patients with non-small-cell lung carcinoma. The planning process often is based on separately acquired FDG-PET/CT and planning CT scans. We compared intraindividual differences between PET acquired in diagnostic (D-PET) and RT treatment position (RT-PET) coregistered with planning CTs acquired using different breathing protocols. Methods and Materials: Sixteen patients with non-small-cell lung carcinoma underwent two PET acquisitions (D-PET and RT-PET) and three planning CT acquisitions (expiration [EXP], inspiration [INS], and mid-breath hold [MID]) on the same day. All scans were rigidly coregistered, resulting in six fused data sets: D-INS, D-EXP, D-MID, RT-INS, RT-EXP, and RT-MID. Fusion accuracy was assessed by three readers at eight anatomic landmarks, lung apices, aortic arch, heart, spine, sternum, carina, diaphragm, and tumor, by using an alignment score ranging from 1 (no alignment) to 5 (exact alignment). Results: The RT-PET showed better alignment with any CT than D-PET (p < 0.001). With regard to breathing, RT-MID showed the best mean alignment score (3.7 {+-} 1.0), followed by RT-EXP (3.5 {+-} 0.9) and RT-INS (3.0 {+-} 0.8), with all differences significant (p < 0.001). Comparing alignment scores with regard to anatomic landmarks, the largest deviations were found at the diaphragm, heart, and apices. Overall, there was fair agreement ({kappa} = 0.48; p < 0.001) among the three readers. Conclusions: Significantly better fusion of PET and planning CT can be reached with PET acquired in the RT position. The best intraindividual fusion results are obtained with the planning CT performed during mid-breath hold. Our data justify the acquisition of a separate planning PET in RT treatment position if only a diagnostic PET scan is available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atlas-Based Semiautomatic Target Volume Definition (CTV) for Head-and-Neck Tumors

Purpose: To develop a new semiautomatic method to improve target delineation in head-and-neck cancer. Methods and Materials: We implemented an atlas-based software program using fourteen anatomic landmarks as well as the most superior and inferior computerd tomography slices for automatic target delineation, using an advanced laryngeal carcinoma as an example. Registration was made by an affine transformation. Evaluation was performed with manually drawn contours for comparison. Three physicians sampled and further applied a target volume atlas to ten other computer tomography data sets. In addition, a rapid three-dimensional (3D) correction program was developed. Results: The mean time to the first semiautomatic target delineation proposal was 2.7 minutes. Manual contouring required 20.2 minutes per target, whereas semiautomatic target volume definition with the rapid 3D correction was completed in only 9.7 minutes. The net calculation time for image registration of the target volume atlas was negligible (approximately 0.6 seconds). Our method depicted a sufficient adaptation of the target volume atlas on the new data sets, with a mean similarity index of 77.2%. The similarity index increased up to 85% after 3D correction performed by the physicians. Conclusions: We have developed a new, feasible method for semiautomatic contouring that saves a significant amount (51.8%) of target delineation time for head-and-neck cancer patients. This approach uses a target volume atlas and a landmark model. The software was evaluated by means of laryngeal cancer but has important implications for various tumor types whereby target volumes remain constant in form and do not move with respiration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adoption of Preoperative Radiation Therapy for Rectal Cancer From 2000 to 2006: A Surveillance, Epidemiology, and End Results Patterns-of-Care Study

Purpose: The German rectal study determined that preoperative radiation therapy (RT) as a component of combined-modality therapy decreased local tumor recurrence, increased sphincter preservation, and decreased treatment toxicity compared with postoperative RT for rectal cancer. We evaluated the use of preoperative RT after the presentation of the landmark German rectal study results and examined the impact of tumor and sociodemographic factors on receiving preoperative RT. Methods and Materials: In total, 20,982 patients who underwent surgical resection for T3-T4 and/or node-positive rectal adenocarcinoma diagnosed from 2000 through 2006 were identified from the Surveillance, Epidemiology, and End Results tumor registries. We analyzed trends in preoperative RT use before and after publication of the findings from the German rectal study. We also performed multivariate logistic regression to identify factors associated with receiving preoperative RT. Results: Among those treated with RT, the proportion of patients treated with preoperative RT increased from 33.3% in 2000 to 63.8% in 2006. After adjustment for age; gender; race/ethnicity; marital status; Surveillance, Epidemiology, and End Results registry; county-level education; T stage; N stage; tumor size; and tumor grade, there was a significant association between later year of diagnosis and an increase in preoperative RT use (adjusted odds ratio, 1.26/y increase; 95% confidence interval, 1.23-1.29). When we compared the years before and after publication of the German rectal study (2000-2003 vs. 2004-2006), patients were more likely to receive preoperative RT than postoperative RT in 2004-2006 (adjusted odds ratio, 2.35; 95% confidence interval, 2.13-2.59). On multivariate analysis, patients who were older, who were female, and who resided in counties with lower educational levels had significantly decreased odds of receiving preoperative RT. Conclusions: After the publication of the landmark German rectal study, there was widespread, rapid adoption of preoperative RT for locally advanced rectal cancer. However, preoperative RT may be underused in certain sociodemographic groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validating Fiducial Markers for Image-Guided Radiation Therapy for Accelerated Partial Breast Irradiation in Early-Stage Breast Cancer

Purpose: Image-guided radiation therapy (IGRT) may be beneficial for accelerated partial breast irradiation (APBI). The goal was to validate the use of intraparenchymal textured gold fiducials in patients receiving APBI. Methods and Materials: Twenty-six patients were enrolled on this prospective study that had three or four textured gold intraparenchymal fiducials placed at the periphery of the lumpectomy cavity and were treated with three-dimensional (3D) conformal APBI. Free-breathing four-dimensional computed tomography image sets were obtained pre- and posttreatment, as were daily online megavoltage (MV) orthogonal images. Intrafraction motion, variations in respiratory motion, and fiducial marker migration were calculated using the 3D coordinates of individual fiducials and a calculated center of mass (COM) of the fiducials. We also compared the relative position of the fiducial COM with the geometric center of the seroma. Results: There was less than 1 mm of intrafraction respiratory motion, variation in respiratory motion, or fiducial marker migration. The change in seroma position relative to the fiducial COM was 1 mm {+-} 1 mm. The average position of the geometric seroma relative to the fiducial COM pretreatment compared with posttreatment was 1 mm {+-} 1 mm. The largest daily variation in displacement when using bony landmark was in the anteroposterior direction and two standard deviations (SD) of this variation was 10 mm. The average variation in daily separation between the fiducial pairs from daily MV images was 3 mm {+-} 3 mm therefore 2 SD is 6 mm. Conclusion: Fiducial markers are stable throughout the course of APBI. Planning target volume margins when using bony landmarks should be 10 mm and can be reduced to 6 mm if using fiducials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Residual Setup Errors of Different IGRT Alignment Procedures for Head and Neck IMRT and the Resulting Dosimetric Impact

Purpose: To assess residual setup errors during head and neck radiation therapy and the resulting consequences for the delivered dose for various patient alignment procedures. Methods and Materials: Megavoltage cone beam computed tomography (MVCBCT) scans from 11 head and neck patients who underwent intensity modulated radiation therapy were used to assess setup errors. Each MVCBCT scan was registered to its reference planning kVCT, with seven different alignment procedures: automatic alignment and manual registration to 6 separate bony landmarks (sphenoid, left/right maxillary sinuses, mandible, cervical 1 [C1]-C2, and C7-thoracic 1 [T1] vertebrae). Shifts in the different alignments were compared with each other to determine whether there were any statistically significant differences. Then, the dose distribution was recalculated on 3 MVCBCT images per patient for every alignment procedure. The resulting dose-volume histograms for targets and organs at risk (OARs) were compared to those from the planning kVCTs. Results: The registration procedures produced statistically significant global differences in patient alignment and actual dose distribution, calling for a need for standardization of patient positioning. Vertically, the automatic, sphenoid, and maxillary sinuses alignments mainly generated posterior shifts and resulted in mean increases in maximal dose to OARs of >3% of the planned dose. The suggested choice of C1-C2 as a reference landmark appears valid, combining both OAR sparing and target coverage. Assuming this choice, relevant margins to apply around volumes of interest at the time of planning to take into account for the relative mobility of other regions are discussed. Conclusions: Use of different alignment procedures for treating head and neck patients produced variations in patient setup and dose distribution. With concern for standardizing practice, C1-C2 reference alignment with relevant margins around planning volumes seems to be a valid option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Are Radiation Therapy Oncology Group Para-aortic Contouring Guidelines for Pancreatic Neoplasm Applicable to Other Malignancies—Assessment of Nodal Distribution in Gynecological Malignancies

Purpose: Intensity modulated radiation therapy is used to reduce dose to adjacent critical structures while maintaining adequate target coverage, but it requires precise target localization. We report the 3-dimensional distribution of para-aortic (PA) lymph nodes (LN) in pelvic malignancies. We propose a guideline to accurately define the PA LN by anatomic landmarks and compare our data with published guidelines for pancreatic cancer. Methods and Materials: A retrospective analysis was performed on 46 patients with pelvic malignancies and positive PA LNs. Positive LNs were defined based on size and morphology or fluorodeoxyglucose avidity. All PA LNs were characterized into 3 groups based on location: left PA (between aorta and left psoas muscle), aortocaval (between aorta and inferior vena cava), and right paracaval (between inferior vena cava and right psoas muscle). Patients with retrocrural LNs were also analyzed. Results: One hundred thirty-three positive PA LNs were evaluated. The majority of the PA LNs were in the left PA (59%) and aortocaval (35) regions, and only 8% were in the right paracaval region. All patients with positive right paracaval LNs also had involved left PA LNs, with only 1 exception. The highest PA LN involvement was at the level of the renal vessels and was seen in 28% of patients. Of these patients with disease extending to renal vessels, 38% had retrocrural LN involvement. Conclusions: The nodal contouring for the PA region should not be defined by a fixed circumferential margin around the vessels. The left PA and aortocaval spaces should be covered adequately because these are common locations of PA LNs. For microscopic disease superiorly, contouring should extend up to renal vessels rather than a fixed bony landmark. For patients who have nodal involvement at renal vessels, one can consider including retrocrural LNs. Radiation Therapy Oncology Group Para-aortic Contouring Guidelines for Pancreatic Neoplasm are not applicable to gynecological malignancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗