Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LABELLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SU-F-J-111: A Novel Distance-Dose Weighting Method for Label Fusion in Multi- Atlas Segmentation for Prostate Radiation Therapy

Purpose: A novel distance-dose weighting method for label fusion was developed to increase segmentation accuracy in dosimetrically important regions for prostate radiation therapy. Methods: Label fusion as implemented in the original SIMPLE (OS) for multi-atlas segmentation relies iteratively on the majority vote to generate an estimated ground truth and DICE similarity measure to screen candidates. The proposed distance-dose weighting puts more values on dosimetrically important regions when calculating similarity measure. Specifically, we introduced distance-to-dose error (DDE), which converts distance to dosimetric importance, in performance evaluation. The DDE calculates an estimated DE error derived from surface distance differences between the candidate and estimated ground truth label by multiplying a regression coefficient. To determine the coefficient at each simulation point on the rectum, we fitted DE error with respect to simulated voxel shift. The DEs were calculated by the multi-OAR geometry-dosimetry training model previously developed in our research group. Results: For both the OS and the distance-dose weighted SIMPLE (WS) results, the evaluation metrics for twenty patients were calculated using the ground truth segmentation. The mean difference of DICE, Hausdorff distance, and mean absolute distance (MAD) between OS and WS have shown 0, 0.10, and 0.11, respectively. In partial MAD of WS which calculates MAD within a certain PTV expansion voxel distance, the lower MADs were observed at the closer distances from 1 to 8 than those of OS. The DE results showed that the segmentation from WS produced more accurate results than OS. The mean DE error of V75, V70, V65, and V60 were decreased by 1.16%, 1.17%, 1.14%, and 1.12%, respectively. Conclusion: We have demonstrated that the method can increase the segmentation accuracy in rectum regions adjacent to PTV. As a result, segmentation using WS have shown improved dosimetric accuracy than OS. The WS will provide dosimetrically important label selection strategy in multi-atlas segmentation. CPRIT grant RP150485.

60 APPLIED LIFE SCIENCES↗

Gold nanocrystal labels provide a sequence–to–3D structure map in SAXS reconstructions

Small-angle x-ray scattering (SAXS) is a powerful technique to probe the structure of biological macromolecules and their complexes under virtually arbitrary solution conditions, without the need for crystallization. While it is possible to reconstruct molecular shapes from SAXS data ab initio, the resulting electron density maps have a resolution of ~1 nm and are often insufficient to reliably assign secondary structure elements or domains. We show that SAXS data of gold-labeled samples significantly enhance the information content of SAXS measurements, allowing the unambiguous assignment of macromolecular sequence motifs to specific locations within a SAXS structure. We first demonstrate our approach for site-specifically internally and end-labeled DNA and an RNA motif. In addition, we present a protocol for highly uniform and site-specific labeling of proteins with small (~1.4 nm diameter) gold particles and apply our method to the signaling protein calmodulin. In all cases, the position of the small gold probes can be reliably identified in low-resolution electron density maps. Enhancing low-resolution measurements by site-selective gold labeling provides an attractive approach to aid modeling of a large range of macromolecular systems.

Science & Technology - Other Topics↗

Identification of site-specific isotopic labels by vibrational spectroscopy in the electron microscope

The identification of isotopic labels by conventional macroscopic techniques lacks spatial resolution and requires relatively large quantities of material for measurements. We recorded the vibrational spectra of an α amino acid, l -alanine, with damage-free “aloof” electron energy-loss spectroscopy in a scanning transmission electron microscope to directly resolve carbon-site–specific isotopic labels in real space with nanoscale spatial resolution. An isotopic red shift of 4.8 ± 0.4 milli–electron volts in C–O asymmetric stretching modes was observed for 13 C-labeled l -alanine at the carboxylate carbon site, which was confirmed by macroscopic infrared spectroscopy and theoretical calculations. The accurate measurement of this shift opens the door to nondestructive, site-specific, spatially resolved identification of isotopically labeled molecules with the electron microscope.

74 ATOMIC AND MOLECULAR PHYSICS↗

Sandia Image Labeling Tool (SILT)

SAND2025-01840O Sandia Image Labeling Tool (SILT) is a Python tool that labels images for machine learning and other applications. SILT uploads JSON files to create a template for labeling an image. SILT can then upload images, including images that are tens of GB large and dynamically loads them in a manner that a user, with a very modest spec laptop, can handle. It then saves the label as a JSON using the template. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Pitts, Todd↗

A Method to Constrain Genome-Scale Models with 13 C Labeling Data

Current limitations in quantitatively predicting biological behavior hinder our efforts to engineer biological systems to produce biofuels and other desired chemicals. Here, we present a new method for calculating metabolic fluxes, key targets in metabolic engineering, that incorporates data from 13C labeling experiments and genome-scale models. The data from 13 C labeling experiments provide strong flux constraints that eliminate the need to assume an evolutionary optimization principle such as the growth rate optimization assumption used in Flux Balance Analysis (FBA). This effective constraining is achieved by making the simple but biologically relevant assumption that flux flows from core to peripheral metabolism and does not flow back. The new method is significantly more robust than FBA with respect to errors in genome-scale model reconstruction. Furthermore, it can provide a comprehensive picture of metabolite balancing and predictions for unmeasured extracellular fluxes as constrained by 13 C labeling data. A comparison shows that the results of this new method are similar to those found through 13 C Metabolic Flux Analysis ( 13 C MFA) for central carbon metabolism but, additionally, it provides flux estimates for peripheral metabolism. The extra validation gained by matching 48 relative labeling measurements is used to identify where and why several existing COnstraint Based Reconstruction and Analysis (COBRA) flux prediction algorithms fail. We demonstrate how to use this knowledge to refine these methods and improve their predictive capabilities. This method provides a reliable base upon which to improve the design of biological systems.

59 BASIC BIOLOGICAL SCIENCES↗

Microfluidic Radiometal Labeling Systems for Biomolecules

In a typical labeling procedure with radiometals, such as Cu-64 and Ga-68; a very large (~ 100-fold) excess of the non-radioactive reactant (precursor) is used to promote rapid and efficient incorporation of the radioisotope into the PET imaging agent. In order to achieve high specific activities, careful control of reaction conditions and extensive chromatographic purifications are required in order to separate the labeled compounds from the cold precursors. Here we propose a microfluidic approach to overcome these problems, and achieve high specific activities in a more convenient, semi-automated fashion and faster time frame. Microfluidic reactors, consisting of a network of micron-sized channels (typical dimensions in the range 10 - 300¼m), filters, separation columns, electrodes and reaction loops/chambers etched onto a solid substrate, are now emerging as an extremely useful technology for the intensification and miniaturization of chemical processes. The ability to manipulate, process and analyze reagent concentrations and reaction interfaces in both space and time within the channel network of a microreactor provides the fine level of reaction control that is desirable in PET radiochemistry practice. These factors can bring radiometal labeling, specifically the preparation of radio-labeled biomolecules such as antibodies, much closer to their theoretical maximum specific activities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microfluidic technology platforms for synthesizing, labeling and measuring the kinetics of transport and biochemical reactions for developing molecular imaging probes

Radiotracer techniques are used in environmental sciences, geology, biology and medicine. Radiotracers with Positron Emission Tomography (PET) provided biological examinations of ~3 million patients 2008. Despite the success of positron labeled tracers in many sciences, there is limited access in an affordable and convenient manner to develop and use new tracers. Integrated microfluidic chips are a new technology well matched to the concentrations of tracers. Our goal is to develop microfluidic chips and new synthesis approaches to enable wide dissemination of diverse types of tracers at low cost, and to produce new generations of radiochemists for which there are many unfilled jobs. The program objectives are to: 1. Develop an integrated microfluidic platform technology for synthesizing and 18F-labeling diverse arrays of different classes of molecules. 2. Incorporate microfluidic chips into small PC controlled devices (“Synthesizer”) with a platform interfaced to PC for electronic and fluid input/out control. 3. Establish a de-centralized model with Synthesizers for discovering and producing molecular imaging probes, only requiring delivery of inexpensive [18F]fluoride ion from commercial PET radiopharmacies vs the centralized approach of cyclotron facilities synthesizing and shipping a few different types of 18F-probes. 4. Develop a position sensitive avalanche photo diode (PSAPD) camera for beta particles embedded in a microfluidic chip for imaging and measuring transport and biochemical reaction rates to valid new 18F-labeled probes in an array of cell cultures. These objectives are met within a research and educational program integrating radio-chemistry, synthetic chemistry, biochemistry, engineering and biology in the Crump Institute for Molecular Imaging. The Radiochemistry Training Program exposes PhD and post doctoral students to molecular imaging in vitro in cells and microorganisms in microfluidic chips and in vivo with PET, from new technologies for radiochemistry (macro to micro levels), biochemistry and biology to imaging principles, tracer kinetics, pharmacokinetics and biochemical assays. New generations of radiochemists will be immersed in the biochemistry and biology for which their labeled probes are being developed for assays of these processes. In this program engineers and radio-chemists integrate the principles of microfluidics and radiolabeling along with proper system design and chemistry rule sets to yield Synthesizers enabling biological and pharmaceutical scientists to develop diverse arrays of probes to pursue their interests. This progression would allow also radiochemists to focus on the further evolution of rapid, high yield synthetic reactions with new enabling technologies, rather than everyday production of radiotracers that should be done by technologists. The invention of integrated circuits in electronics established a platform technology that allowed an evolution of ideas and applications far beyond what could have been imagined at the beginning. Rather than provide a technology for the solution to a single problem, it is hoped that microfluidic radiochemistry will be an enabling platform technology for others to solve many problems. As part of this objective, another program goal is to commercialize the technologies that come from this work so that they can be provided to others who wish to use it.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

ClimateNet: an expert-labeled open dataset and deep learning architecture for enabling high-precision analyses of extreme weather

Abstract. Identifying, detecting, and localizing extreme weather events is a crucial first step in understanding how they may vary under different climate change scenarios. Pattern recognition tasks such as classification, object detection, and segmentation (i.e., pixel-level classification) have remained challenging problems in the weather and climate sciences. While there exist many empirical heuristics for detecting extreme events, the disparities between the output of these different methods even for a single event are large and often difficult to reconcile. Given the success of deep learning (DL) in tackling similar problems in computer vision, we advocate a DL-based approach. DL, however, works best in the context of supervised learning – when labeled datasets are readily available. Reliable labeled training data for extreme weather and climate events is scarce. We create “ClimateNet” – an open, community-sourced human-expert-labeled curated dataset that captures tropical cyclones (TCs) and atmospheric rivers (ARs) in high-resolution climate model output from a simulation of a recent historical period. We use the curated ClimateNet dataset to train a state-of-the-art DL model for pixel-level identification – i.e., segmentation – of TCs and ARs. We then apply the trained DL model to historical and climate change scenarios simulated by the Community Atmospheric Model (CAM5.1) and show that the DL model accurately segments the data into TCs, ARs, or “the background” at a pixel level. Further, we show how the segmentation results can be used to conduct spatially and temporally precise analytics by quantifying distributions of extreme precipitation conditioned on event types (TC or AR) at regional scales. The key contribution of this work is that it paves the way for DL-based automated, high-fidelity, and highly precise analytics of climate data using a curated expert-labeled dataset – ClimateNet. ClimateNet and the DL-based segmentation method provide several unique capabilities: (i) they can be used to calculate a variety of TC and AR statistics at a fine-grained level; (ii) they can be applied to different climate scenarios and different datasets without tuning as they do not rely on threshold conditions; and (iii) the proposed DL method is suitable for rapidly analyzing large amounts of climate model output. While our study has been conducted for two important extreme weather patterns (TCs and ARs) in simulation datasets, we believe that this methodology can be applied to a much broader class of patterns and applied to observational and reanalysis data products via transfer learning.

54 ENVIRONMENTAL SCIENCES↗

Document clustering methods, document cluster label disambiguation methods, document clustering apparatuses, and articles of manufacture

Document clustering methods, document cluster label disambiguation methods, document clustering apparatuses, and articles of manufacture are described. In one aspect, a document clustering method includes providing a document set comprising a plurality of documents, providing a cluster comprising a subset of the documents of the document set, using a plurality of terms of the documents, providing a cluster label indicative of subject matter content of the documents of the cluster, wherein the cluster label comprises a plurality of word senses, and selecting one of the word senses of the cluster label.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

A Comparative Analysis of Computational Approaches to Relative Protein Quantification Using Peptide Peak Intensities in Label-free LC-MS Proteomics Experiments

Liquid chromatography coupled with mass spectrometry (LC-MS) is widely used to identify and quantify peptides in complex biological samples. In particular, label-free shotgun proteomics is highly effective for the identification of peptides and subsequently obtaining a global protein profile of a sample. As a result, this approach is widely used for discovery studies. Typically, the objective of these discovery studies is to identify proteins that are affected by some condition of interest (e.g. disease, exposure). However, for complex biological samples, label-free LC-MS proteomics experiments measure peptides and do not directly yield protein quantities. Thus, protein quantification must be inferred from one or more measured peptides. In recent years, many computational approaches to relative protein quantification of label-free LC-MS data have been published. In this review, we examine the most commonly employed quantification approaches to relative protein abundance from peak intensity values, evaluate their individual merits, and discuss challenges in the use of the various computational approaches.

Environmental Molecular Sciences Laboratory↗

Conformational detection of prion protein with biarsenical labeling and FlAsH fluorescence

Prion diseases are associated with the misfolding of the host-encoded cellular prion protein (PrP{sup C}) into a disease associated form (PrP{sup Sc}). Recombinant PrP can be refolded into either an {alpha}-helical rich conformation ({alpha}-PrP) resembling PrP{sup C} or a {beta}-sheet rich, protease resistant form similar to PrP{sup Sc}. Here, we generated tetracysteine tagged recombinant PrP, folded this into {alpha}- or {beta}-PrP and determined the levels of FlAsH fluorescence. Insertion of the tetracysteine tag at three different sites within the 91-111 epitope readily distinguished {beta}-PrP from {alpha}-PrP upon FlAsH labeling. Labelling of tetracysteine tagged PrP in the {alpha}-helical form showed minimal fluorescence, whereas labeling of tagged PrP in the {beta}-sheet form showed high fluorescence indicating that this region is exposed upon conversion. This highlights a region of PrP that can be implicated in the development of diagnostics and is a novel, protease free mechanism for distinguishing PrP{sup Sc} from PrP{sup C}. This technique may also be applied to any protein that undergoes conformational change and/or misfolding such as those involved in other neurodegenerative disorders including Alzheimer's, Huntington's and Parkinson's diseases.

60 APPLIED LIFE SCIENCES↗

Single molecule tracking of quantum dot-labeled mRNAs in a cell nucleus

Single particle tracking (SPT) is a powerful technique for studying mRNA dynamics in cells. Although SPT of mRNA has been performed by labeling mRNA with fluorescent dyes or proteins, observation of mRNA for long durations with high temporal resolution has been difficult due to weak fluorescence and rapid photobleaching. Using quantum dots (QDs), we succeeded in observing the movement of individual mRNAs for more than 60 s, with a temporal resolution of 30 ms. Intronless and truncated ftz mRNA, synthesized in vitro and labeled with QDs, was microinjected into the nuclei of Cos7 cells. Almost all mRNAs were in motion, and statistical analyses revealed anomalous diffusion between barriers, with a microscopic diffusion coefficient of 0.12 {mu}m{sup 2}/s and a macroscopic diffusion coefficient of 0.025 {mu}m{sup 2}/s. Diffusion of mRNA was observed in interchromatin regions but not in histone2B-GFP-labeled chromatin regions. These results provide direct evidence of channeled mRNA diffusion in interchromatin regions.

60 APPLIED LIFE SCIENCES↗

Acetylation and glycation of fibrinogen in vitro occur at specific lysine residues in a concentration dependent manner: A mass spectrometric and isotope labeling study

Highlights: Black-Right-Pointing-Pointer Fibrinogen was incubated in vitro with glucose or aspirin. Black-Right-Pointing-Pointer Acetylations and glycations were found at twelve lysine sites by mass spectrometry. Black-Right-Pointing-Pointer The labeling by aspirin and glucose occurred dose-dependently. Black-Right-Pointing-Pointer No competition between glucose and aspirin for binding to fibrinogen was found. -- Abstract: Aspirin may exert part of its antithrombotic effects through platelet-independent mechanisms. Diabetes is a condition in which the beneficial effects of aspirin are less prominent or absent - a phenomenon called 'aspirin resistance'. We investigated whether acetylation and glycation occur at specific sites in fibrinogen and if competition between glucose and aspirin in binding to fibrinogen occurs. Our hypothesis was that such competition might be one explanation to 'aspirin resistance' in diabetes. After incubation of fibrinogen in vitro with aspirin (0.8 mM, 24 h) or glucose (100 mM, 5-10 days), we found 12 modified sites with mass spectrometric techniques. Acetylations in the {alpha}-chain: {alpha}K191, {alpha}K208, {alpha}K224, {alpha}K429, {alpha}K457, {alpha}K539, {alpha}K562, in the {beta}-chain: {beta}K233, and in the {gamma}-chain: {gamma}K170 and {gamma}K273. Glycations were found at {beta}K133 and {gamma}K75, alternatively {gamma}K85. Notably, the lysine 539 is a site involved in FXIII-mediated cross-linking of fibrin. With isotope labeling in vitro, using [{sup 14}C-acetyl]salicylic acid and [{sup 14}C]glucose, a labeling of 0.013-0.084 and 0.12-0.5 mol of acetylated and glycated adduct/mol fibrinogen, respectively, was found for clinically (12.9-100 {mu}M aspirin) and physiologically (2-8 mM glucose) relevant plasma concentrations. No competition between acetylation and glycation could be demonstrated. Thus, fibrinogen is acetylated at several lysine residues, some of which are involved in the cross-linking of fibrinogen. This may mechanistically explain why aspirin facilitates fibrin degradation. We find no support for the idea that glycation of fibrin(ogen) interferes with acetylation of fibrinogen.

60 APPLIED LIFE SCIENCES↗

Spatial arrangement of rhodopsin in retinal rod outer segment membranes studied by spin-labeling and pulsed electron double resonance

Highlights: Black-Right-Pointing-Pointer Use of spin labeling and PELDOR to measure inter-rhodopsin distance in ROS. Black-Right-Pointing-Pointer Strong decay of PELDOR signal indicated a high density (mM range) of rhodopsin. Black-Right-Pointing-Pointer The decay was modeled by rhodopsin monomers dispersed in a planar membrane. -- Abstract: We have determined the spatial arrangement of rhodopsin in the retinal rod outer segment (ROS) membrane by measuring the distances between rhodopsin molecules in which native cysteines were spin-labeled at {approx}1.0 mol/mol rhodopsin. The echo modulation decay of pulsed electron double resonance (PELDOR) from spin-labeled ROS curved slightly with strong background decay. This indicated that the rhodopsin was densely packed in the retina and that the rhodopsin molecules were not aligned well. The curve was simulated by a model in which rhodopsin is distributed randomly as monomers in a planar membrane.

60 APPLIED LIFE SCIENCES↗

Nucleotide-dependent displacement and dynamics of the α-1 helix in kinesin revealed by site-directed spin labeling EPR

Highlights: •Dipolar EPR detects the distance between the spin-labeled kinesin α-1 and α-2 helices. •The distance has at least two populations: 1.5 nm (in crystal form: 20%) and >2.5 nm. •The short distance conformer was populated 40% in the apo state with microtubules. •ATP analog or ADP binding caused the 1.5 nm distance to be less populated (∼20%). •The α-1 helix moves closer to the neck-linker (away from α-2) to facilitate docking. -- Abstract: In kinesin X-ray crystal structures, the N-terminal region of the α-1 helix is adjacent to the adenine ring of the bound nucleotide, while the C-terminal region of the helix is near the neck-linker (NL). Here, we monitor the displacement of the α-1 helix within a kinesin monomer bound to microtubules (MTs) in the presence or absence of nucleotides using site-directed spin labeling EPR. Kinesin was doubly spin-labeled at the α-1 and α-2 helices, and the resulting EPR spectrum showed dipolar broadening. The inter-helix distance distribution showed that 20% of the spins have a peak characteristic of 1.4–1.7 nm separation, which is similar to what is predicted from the X-ray crystal structure, albeit 80% were beyond the sensitivity limit (>2.5 nm) of the method. Upon MT binding, the fraction of kinesin exhibiting an inter-helix distance of 1.4–1.7 nm in the presence of AMPPNP (a non-hydrolysable ATP analog) and ADP was 20% and 25%, respectively. In the absence of nucleotide, this fraction increased to 40–50%. These nucleotide-induced changes in the fraction of kinesin undergoing displacement of the α-1 helix were found to be related to the fraction in which the NL undocked from the motor core. It is therefore suggested that a shift in the α-1 helix conformational equilibrium occurs upon nucleotide binding and release, and this shift controls NL docking onto the motor core.

60 APPLIED LIFE SCIENCES↗

RFP tags for labeling secretory pathway proteins

Highlights: • Membrane protein Orai1 can be used to report the fusion properties of RFPs. • Artificial puncta are affected by dissociation constant as well as pKa of RFPs. • Among tested RFPs mOrange2 is the best choice for secretory protein labeling. - Abstract: Red fluorescent proteins (RFPs) are useful tools for live cell and multi-color imaging in biological studies. However, when labeling proteins in secretory pathway, many RFPs are prone to form artificial puncta, which may severely impede their further uses. Here we report a fast and easy method to evaluate RFPs fusion properties by attaching RFPs to an environment sensitive membrane protein Orai1. In addition, we revealed that intracellular artificial puncta are actually colocalized with lysosome, thus besides monomeric properties, pKa value of RFPs is also a key factor for forming intracellular artificial puncta. In summary, our current study provides a useful guide for choosing appropriate RFP for labeling secretory membrane proteins. Among RFPs tested, mOrange2 is highly recommended based on excellent monomeric property, appropriate pKa and high brightness.

60 APPLIED LIFE SCIENCES↗

NMR conformational properties of an Anthrax Lethal Factor domain studied by multiple amino acid-selective labeling

Highlights: • A polypeptide, N-ALF{sub 233}, was overexpressed in E. coli and successfully isolated. • We produced {sup 2}H/{sup 15}N/{sup 13}C labeled protein samples. • Amino acid selective approaches were applied. • We acquired several heteronuclear NMR spectra, to complete the backbone assignment. • Prediction of the secondary structure was performed. - Abstract: NMR-based structural biology urgently needs cost- and time-effective methods to assist both in the process of acquiring high-resolution NMR spectra and their subsequent analysis. Especially for bigger proteins (>20 kDa) selective labeling is a frequently used means of sequence-specific assignment. In this work we present the successful overexpression of a polypeptide of 233 residues, corresponding to the structured part of the N-terminal domain of Anthrax Lethal Factor, using Escherichia coli expression system. The polypeptide was subsequently isolated in pure, soluble form and analyzed structurally by solution NMR spectroscopy. Due to the non-satisfying quality and resolution of the spectra of this 27 kDa protein, an almost complete backbone assignment became feasible only by the combination of uniform and novel amino acid-selective labeling schemes. Moreover, amino acid-type selective triple-resonance NMR experiments proved to be very helpful.

60 APPLIED LIFE SCIENCES↗

An isotopic labeling investigation into the influence of the nitro group on LLM-105 thermal decomposition

Here, this work presents the first application of isotopically labeled LLM-105 (2,6-diamino-3,5-dinitropyrazine-1-oxide) to investigate thermal decomposition pathways. Specially synthesized LLM-105 isotopologues were utilized to isolate the influence of labeled 15 NO 2 nitro groups on the formation of lightgas products. Simultaneous differential scanning calorimetry, thermo-gravimetric, and mass spectrometry measurements were employed to track the evolution of product gases, enabling the direct comparison of isotopically shifted species with unlabeled LLM-105. Key findings show that C 2 N 2 production is mainly dependent on nitrogen sources from either the amine groups or the pyrazine ring (i.e., not the nitro groups). The formation of NO, N 2 , and N 2 O all involves the nitro groups to some extent. NO (nitric oxide) was found to be the predominant gas species directly formed from the nitro group of LLM-105. In contrast, mixed nitrogen isotopologues of N 2 and N 2 O (i.e., 14 N 15 N and 15 NNO) formed more readily in comparison to their pure counterparts (i.e., 15 N 2 and 15 N 2 O). This indicates the amine and/or pyrazine groups of LLM-105, in addition to the nitro group, are involved in the decomposition pathways forming N 2 and N 2 O. In addition, our investigation led to the discovery of two previously unreported decomposition products (CHO and HNCO), which were confirmed through hydrogen labelling utilizing deuterium isotopes. These results provide detailed speciation trends of gaseous products during LLM-105 decomposition, offering new insights into reaction pathways. Experimental data reported here will support the development of a detailed chemical kinetics model for LLM-105, essential for the safe handling of high explosives.

Chemistry - Chemical explosives↗