Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “KHZ RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Edge turbulence velocity preceding the L-H transition in NSTX

The low-to-high mode or L-H transition in tokamaks involves a sudden reduction in the edge turbulence level and decrease in the edge plasma transport. The mechanism for the L-H transition is widely believed to be associated changes in the the poloidal velocity of the edge turbulence. Using a gas puff imaging (GPI) diagnostic, the poloidally averaged poloidal turbulence velocity < V pol > pol was measured for a set of 16 shots with L-H transitions in NSTX. These measurements were focused -2 cm inside the separatrix where the relative fluctuation level as seen in GPI decreases significantly and consistently at the transition. Herein, the magnitude of this poloidal velocity preceding the transition varied widely, ranging from |V pol | ~1-4 km/sec during the last 1 msec before the transition, and the magnitude of the radial gradient also had a wide shot-to-shot range of |grad V pol | ~ 0.34 to 1.9 km/sec/cm during this same time. The frequency spectrum of < V pol > pol during the 30 msec before the transition had a near-coherent peak at ~2-5 kHz, but only in about half of these shots. In general, there were no clear and consistent changes in the poloidal velocity of the turbulence preceding the L-H transition in this database.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ tuning of optomechanical crystals with nano-oxidation

Optomechanical crystals are a promising device platform for quantum transduction and sensing. Precise targeting of the optical and acoustic resonance frequencies of these devices is crucial for future advances on these fronts. However, fabrication disorder in these wavelength-scale nanoscale devices typically leads to inhomogeneous resonance frequencies. Here we achieve in situ , selective frequency tuning of optical and acoustic resonances in silicon optomechanical crystals via electric field-induced nano-oxidation using an atomic-force microscope. Our method can achieve a tuning range >2nm (0.13%) for the optical resonance wavelength in the telecom C-band, and >60MHz (1.2%) for the acoustic resonance frequency at 5 GHz. The tuning resolution of 1.1 pm for the optical wavelength and 150 kHz for the acoustic frequency allows us to spectrally align multiple optomechanical crystal resonators using a pattern generation algorithm. Our results establish a method for precise post-fabrication tuning of optomechanical crystals. This technique can enable coupled optomechanical resonator arrays, scalable resonant optomechanical circuits, and frequency matching of microwave-optical quantum transducers.

Hatipoglu, Utku (ORCID:0000000205119196)↗

A micromirror array with annular partitioning for high-speed random-access axial focusing

Dynamic axial focusing functionality has recently experienced widespread incorporation in microscopy, augmented/virtual reality (AR/VR), adaptive optics and material processing. However, the limitations of existing varifocal tools continue to beset the performance capabilities and operating overhead of the optical systems that mobilize such functionality. The varifocal tools that are the least burdensome to operate (e.g. liquid crystal, elastomeric or optofluidic lenses) suffer from low (≈100 Hz) refresh rates. Conversely, the fastest devices sacrifice either critical capabilities such as their dwelling capacity (e.g. acoustic gradient lenses or monolithic micromechanical mirrors) or low operating overhead (e.g. deformable mirrors). Here, we present a general-purpose random-access axial focusing device that bridges these previously conflicting features of high speed, dwelling capacity and lightweight drive by employing low-rigidity micromirrors that exploit the robustness of defocusing phase profiles. Geometrically, the device consists of an 8.2 mm diameter array of piston-motion and 48-μm-pitch micromirror pixels that provide 2π phase shifting for wavelengths shorter than 1100 nm with 10–90% settling in 64.8 μs (i.e., 15.44 kHz refresh rate). The pixels are electrically partitioned into 32 rings for a driving scheme that enables phase-wrapped operation with circular symmetry and requires <30 V per channel. Optical experiments demonstrated the array’s wide focusing range with a measured ability to target 29 distinct resolvable depth planes. Overall, the features of the proposed array offer the potential for compact, straightforward methods of tackling bottlenecked applications, including high-throughput single-cell targeting in neurobiology and the delivery of dense 3D visual information in AR/VR.

42 ENGINEERING↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

VeryFastCCD: a high frame rate soft X-ray detector

Direct X-ray detection in silicon has been transformative for scattering experiments in biology and materials science. While bump-bonded hybrid pixels have been attractive for hard X-ray detection, the challenge for single photon soft X-ray detection is sufficiently low noise. CCD structures on thick, high-resistivity silicon have been successfully used as sensors over the range of soft to hard X-rays at storage rings and FELs. The VeryFastCCD is a high frame rate, column-parallel CCD sensor with 48 μm pixels. Combined with 256-channel custom readout ASICs, frame rates of 5–10 kHz have been achieved with readout noise as low as 20 e and full-well capacity >4 × 10 5 e/pixel. Thin (10 nm and 100 nm) entrance window contact processes have also been developed which provide >85% quantum efficiency for 285 eV X-rays. Systems are currently being developed for several beamlines at the upgraded Advanced Light Source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Cancellation of Servo-Induced Noise on Stabilized Lasers via Feedforward

Many precision laser applications require active frequency stabilization. However, such stabilization loops operate by pushing noise to frequencies outside their bandwidth, leading to large “servo bumps” that can have deleterious effects for certain applications. The prevailing approach to filtering this noise is to pass the laser through a high-finesse optical cavity, which places constraints on the system design. Here, we propose and demonstrate a different approach where a frequency error signal is derived from a beat note between the laser and the light that passes through the reference cavity. The phase noise derived from this beat note is fed forward to an electro-optic modulator after the laser, carefully accounting for relative delay, for real-time frequency correction. With a hertz-line-width laser, we show ≳20 dB noise suppression at the peak of the servo bump (approximately 250 kHz) and a noise-suppression bandwidth of approximately 5 MHz—well beyond the servo bump. By simulating the Rabi dynamics of a two-level atom with our measured data, we demonstrate substantial improvements to the pulse fidelity over a wide range of Rabi frequencies. Here, our approach offers a simple and versatile method for obtaining a clean spectrum of a narrow-line-width laser, as required in many emerging applications of cold atoms, and is readily compatible with commercial systems that may even include wavelength conversion.

47 OTHER INSTRUMENTATION↗

Compact single-shot soft X-ray photon spectrometer for free-electron laser diagnostics

The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce:YAG scintillator, and a microscope objective to image the scintillation target onto a two-dimensional imaging detector. This spectrometer operates in segmented energy ranges which covers tens of electronvolts for each absorption edge associated with several atomic constituents: carbon, nitrogen, oxygen, and neon. The spectrometer’s performance is demonstrated at a repetition rate of 120 Hz, but our detection scheme can be easily extended to 200 kHz spectral collection by employing a fast complementary metal oxide semiconductor (CMOS) line-scan camera to detect the light from the scintillator. This compact photon spectrometer provides an opportunity for monitoring the spectrum downstream of an endstation in a limited space environment with sub-electronvolt energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of time and spatial domains on monolayer 2D material interface thermal conductance measurement using ns ET-Raman

Raman-based approaches to characterizing thermal properties of nanoscale and microscale materials have proven to be powerful experimental methods. Here, this work explores the potential of energy-transport state-resolved Raman (ET-Raman) for the precise determination of interfacial thermal conductance (G) between monolayer 2D materials and their substrates. ET-Raman employs a continuous wave laser and nanosecond (ns) pulsed laser to induce both steady state and transient heating while simultaneously collecting 2D material temperature information from the Raman signal. A 3D numerical model built using the finite volume method simulates the two differentiated thermal transport processes. The simulated temperature rises are compared with experimental Raman temperature information to extract G. In this study, we investigate the temporal effects of the pulse frequency and pulse width of the ns laser on precise characterization of G. By running multiple simulations for a range of pulsed laser frequencies and pulse widths, we determine that ET-Raman is most sensitive to precise interfacial thermal conductance measurements with short pulse widths (~below 20 ns) and with pulsing frequencies that ensure sufficient cooling time between consecutive pulses (~below 500 kHz). We also conclude that substrate thickness and laser spot size play critical roles in heat distribution and subsequent sensitivity to meaningful G measurements. As both laser spot size and SiO 2 substrate thickness decrease, detection of interfacial thermal transport becomes more difficult. These results offer essential guidance in the design of future Raman-based approaches to thermal measurements using pulsed lasers.

2D materials↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗

Self-Cooling Multiferroic Magnetic Devices

Increasing switching frequency reduces magnetic volume, but conventional ferrites, used from tens to hundreds of kilohertz, cannot sustain the temperature and frequency ranges demanded by current and emerging wide bandgap and ultrawide bandgap devices. Here, this work presents a novel magnetic material architecture combining nanocrystalline magnetic material and multiferroic layers for megahertz power conversion. The high saturation flux density of nanocrystalline alloys supports miniaturization but is traditionally constrained by excessive losses above 10 kHz. A revolutionary multiferroic material with solid-state cooling via caloric materials is defined that will enable the next generation of magnetic devices for wide-bandgap-integrated designs. This letter highlights the fundamental physics behind this capability alongside early development of a finite element analysis for the multiferroic-based magnetic device using ANSYS, showing that the core achieves more uniform thermal distribution and reduces peak temperature by 9 ° C compared to conventional ferrites.

Soft magnetic materials↗

Results from Extended Range SRF Cavity Tuner Tests for LCLS-II HE

The LCLS-II HE superconducting linac can produce multi-energy beams by supporting multiple undulator lines simultaneously. This could be achieved by using the cavity SRF tuner in the off-frequency detune mode. This off-frequency operation method was tested in 8 cryomodules at Fermilab at 2 K. In all tests, the tuners achieved a frequency shift of -565±80 kHz. This study will discuss cavity frequency during each step as it is being assembled in the cryomodule string and finally when it is being tested at 2 K. Tracking the cavity frequency helped enable the tuners to reach this large frequency shift. The specific procedures of tuner setting during assembly will be presented

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results from extended range SRF cavity tuner tests for LCLS-II-HE

The LCLS-II HE superconducting linac can produce multi-energy beams by supporting multiple undulator lines simultaneously. This could be achieved by using the cavity SRF tuner in the off-frequency detune mode. This off-frequency operation method was tested in 8 cryomodules at Fermilab at 2 K. In all the tests the tuners successfully achieved a frequency shift of -565±80 kHz from the 1.3 GHz value. This study discusses the cavity frequency during each stage of assembly from the cryomodule string to when they are finally tested at 2 K. Monitoring the cavity frequency from this initial stage contributed in reaching this large frequency shift. The specific procedures of tuner setting during assembly will be presented.

43 PARTICLE ACCELERATORS↗

Widely tunable, heterogeneously integrated quantum-dot O-band lasers on silicon

Heterogeneously integrated lasers in the O-band are a key component in realizing low-power optical interconnects for data centers and high-performance computing. Quantum-dot-based materials have been particularly appealing for light generation due to their ultralow lasing thresholds, small linewidth enhancement factor, and low sensitivity to reflections. Here, we present widely tunable quantum-dot lasers heterogeneously integrated on silicon-on-insulator substrate. The tuning mechanism is based on Vernier dual-ring geometry, and a 47 nm tuning range with 52 dB side-mode suppression ratio is observed. These parameters show an increase to 52 nm and 58 dB, respectively, when an additional wavelength filter in the form of a Mach–Zehnder interferometer is added to the cavity. The Lorentzian linewidth of the lasers is measured as low as 5.3 kHz.

Malik, Aditya (ORCID:0000000334487577)↗

Observation of Long-Range Wakefield Effects Generated in an Off-Resonance Tesla-Type Cavity

The interest in controlling emittance dilution effects due to off-axis beam transport in accelerator cavities and the resulting dipolar modes is especially important for the facilities with lower emittance beams. The Fermilab Accelerator Science and Technology (FAST) facility has a unique configuration of two single cavities after the photocathode rf gun followed by a cryomodule. The second capture cavity (CC2) was run 15 kHz off resonance and without rf power while a 25-MeV beam was injected into it. The beam centroid effects were tracked by 10 rf button BPMs with bunch-by-bunch position readout capability downstream in a 12-m drift. Possible LRW effects seemed to dominate our previously observed near-resonant HOM effects at mode 14 in this cavity. This mode also shifted in frequency compared to that of the tuned case based on direct measurements. Submacropulse vertical position slewing of 1400 microns at 11 m downstream was observed with a 125 pC/bunch, 50 bunches per macropulse, and 25-MeV beam. The y-position slew amplitudes as a function of z were also measured. Horizontal positions also showed a slew effect. Both are emittance-dilution effects which one wants to mitigate.

Lumpkin, Alex H.↗

Precision spectroscopy of fast, hot, exotic isotopes using machine-learning-assisted event-by-event Doppler correction

We propose an experimental scheme for performing sensitive, high-precision laser spectroscopy studies on fast exotic isotopes. By inducing a stepwise resonant ionization of the atoms traveling inside an electric field and subsequently detecting the ion and the corresponding electron, time-, and position-sensitive measurements of the resulting particles can be performed. Using a mixture density network, we can leverage this information to predict the initial energy of individual atoms and thus apply a Doppler correction of the observed transition frequencies on an event-by-event basis. We conduct numerical simulations of the proposed experimental scheme and show that kHz-level uncertainties can be achieved for ion beams produced at extreme temperatures ( > 10 8 K), with energy spreads as large as 10 keV and nonuniform velocity distributions. The ability to perform in-flight spectroscopy, directly on highly energetic beams, offers unique opportunities to study short-lived isotopes with lifetimes in the millisecond range and below, produced in low quantities, in hot and highly contaminated environments, without the need for cooling techniques. Such species are of marked interest for nuclear structure, astrophysics, and new physics searches. Published by the American Physical Society 2024

Udrescu, S. M. (ORCID:000000021989576X)↗

Tests Of The Extended Range SRF Cavity Tuners For The LCLS-II-HE Project*

The LCLS-II HE superconducting linac can produce multi-energy beams by supporting multiple undulator lines simultaneously. This could be achieved by using the cavity SRF tuner in the off-frequency detune mode. This off-frequency operation method was tested in the verification cryomodule (vCM) and CM 1 at Fermilab at 2 K. In both cases, the tuners achieved a frequency shift of -565$\pm$80 kHz. This study will discuss cavity frequency during each step as it is being assembled in the cryomodule string and finally when it is being tested at 2 K. Tracking the cavity frequency helped enable the tuners to reach this large frequency shift. The specific procedures of tuner setting during assembly will be presented.

43 PARTICLE ACCELERATORS↗

Design of an 8-channel 40 GS/s 20 mW/Ch waveform sampling ASIC in 65 nm CMOS

One picosecond timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in TSMC 65 nm process targetting one picosecond resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing for picosecond time resolution combined with a long effective buffer. Each fast SCA is 1.6 ns long and has a nominal sampling rate of 40 GS/s. The slow SCA is 204.8 ns long and samples at 5 GS/s. Recording of the analog data for each channel is triggered by a fast discriminator capable of multiple triggering during the window of the slow SCA. To achieve a large dynamic range, low leakage, and high bandwidth, the SCA sampling switches are implemented as 2.5 V nMOSFETs controlled by 1.2 V shift registers. Stored analog data are digitized by an external ADC at 10 bits or better. Specifications on operational parameters include a 4 GHz analog bandwidth and a dead time of 20 microseconds, corresponding to a 50 kHz readout rate, determined by the choice of the external ADC. PSEC5 has been submitted for fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas–Liquid Chemical Reactions with Nanosecond Pulses: Role of Frequency and Pulse Delivery Modes

The effects of changes in the mode of delivery of nanosecond pulses in a gas-liquid plasma reactor on the formation of hydrogen peroxide, H 2 O 2 , and, as an indicator for ·OH radicals, the decoloration of methylene blue, MB, were determined for pulse delivery by a) increasing frequency with uniform pulses (5-50 kHz), b) variation of the time between bursts of pulses (burst period), c) changing the inner burst frequency (1 over the time between the pulses in the burst), and d) variation of number of pulses in a burst (N-cycles). H 2 O 2 peroxide formation was not affected by the method of pulse delivery in the range of parameters studied here and all data followed an approximately linear increase in H 2 O 2 production rate with discharge power. In contrast, the MB decoloration rate was affected by the burst modes. In terms of discharge power, the MB decoloration rate was highest for the uniform pulse mode; however, the linear trend in increase of MB decoloration with power when the burst period was varied, suggest that at higher power the burst mode may be more effective than the uniform pulsing. Consideration of the per pulse decoloration with energy per pulse and with number of pulses suggest that the burst mode can affect reactions differently from applying a uniform pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗