TH-A-204-01: Part I - Key Data for Ionizing-Radiation Dosimetry

The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair in dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV x-rays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.

60 APPLIED LIFE SCIENCES↗

TH-A-204-02: Part II - Worldwide Radiation Metrology

The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair in dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV x-rays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.

60 APPLIED LIFE SCIENCES↗

Sci-Thur PM – Brachytherapy 01: Fast brachytherapy dose calculations: Characterization of egs-brachy features to enhance simulation efficiency

Purpose: egs-brachy is a fast, new EGSnrc user-code for brachytherapy applications. This study characterizes egs-brachy features that enhance simulation efficiency. Methods: Calculations are performed to characterize efficiency gains from various features. Simulations include radionuclide and miniature x-ray tube sources in water phantoms and idealized prostate, breast, and eye plaque treatments. Features characterized include voxel indexing of sources to reduce boundary checks during radiation transport, scoring collision kerma via tracklength estimator, recycling photons emitted from sources, and using phase space data to initiate simulations. Bremsstrahlung cross section enhancement (BCSE), uniform bremsstrahlung splitting (UBS), and Russian Roulette (RR) are considered for electronic brachytherapy. Results: Efficiency is enhanced by a factor of up to 300 using tracklength versus interaction scoring of collision kerma and by up to 2.7 and 2.6 using phase space sources and particle recycling respectively compared to simulations in which particles are initiated within sources. On a single 2.5 GHz Intel Xeon E5-2680 processor cor, simulations approximating prostate and breast permanent implant ((2 mm){sup 3} voxels) and eye plaque ((1 mm){sup 3}) treatments take as little as 9 s (prostate, eye) and up to 31 s (breast) to achieve 2% statistical uncertainty on doses within the PTV. For electronic brachytherapy, BCSE, UBS, and RR enhance efficiency by a factor >2000 compared to a factor of >10{sup 4} using a phase space source. Conclusion: egs-brachy features provide substantial efficiency gains, resulting in calculation times sufficiently fast for full Monte Carlo simulations for routine brachytherapy treatment planning.

60 APPLIED LIFE SCIENCES↗

Verification and Validation Tests of the Gamma Library of the ARC Software Package (Rev.1)

As part of the verification and validation (V&V) efforts of the Argonne Reactor Code (ARC) software system to support the Versatile Test Reactor (VTR) project of the U.S. Department of Energy (DOE), work has been performed to verify and validate the gamma (or photon) library of the multigroup cross section generation code MC 2 -3 of the ARC system, which is the essential part of the coupled neutron and gamma heating calculations to determine the heat generation rate or power distribution in the core. This V&V study was carried out in three steps: 1) review of the procedures and utility programs for generating the MC 2 -3 gamma library, 2) verification tests of cross sections and KERMA factors by comparing the total heat generation rate of coupled neutron and gamma calculation with that obtained with reaction Q values under the assumption of local gamma energy deposition and by comparing the prompt heat generation rate with that calculated with the MCNP6.2 code, and 3) validation tests of cross sections and KERMA factors by analyzing the ZPPR-15D gamma dose data measured with thermoluminescent dosimeters (TLD).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improved Gamma Yield and Interaction Cross-Section Libraries of MC2-3

The MC{sup 2}-3 code developed by Argonne National Laboratory (ANL) has been widely used for multigroup cross section generation for fast reactor design and analysis. The neutron cross sections generated with MC{sup 2}-3 have been validated with various fast critical experiments. The gamma production data and interaction cross sections were also verified with the EBR-II benchmark problem. The current gamma calculation process is based on the 21-group gamma libraries generated with the NJOY code, which does not include the delayed gamma production and does not account for the self-shielding effect on the KERMA (Kinetic Energy Released in Material) factor. In order to improve gamma prediction accuracy, the gamma libraries of MC{sup 2}-3 have recently been extended from 21 to 94 groups, including delayed gamma data and kinetic energy release per reaction data. The latter is used to take into account the self-shielding effect on KERMA factors. Gamma transport calculation capabilities have also been added to MC{sup 2}-3. In this paper, we present the updated data and gamma transport capabilities along with the verification tests with ABTR and EBR-II benchmark problems. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Importance of a Patient Dosimetry and Clinical Follow-up Program in the Detection of Radiodermatitis After Long Percutaneous Coronary Interventions

Complex percutaneous interventions often require high radiation doses likely to produce skin radiation injuries. We assessed the methodology used to select patients with potential skin injuries in cardiac procedures and in need of clinical follow-up. We evaluated peak skin dose and clinical follow-up in a case of radiodermatitis produced during a total occlusion recanalization. This prospective study followed CIRSE and ACC/AHA/SCAI recommendations for patient radiation dose management in interventional procedures carried out in a university hospital with a workload of 4200 interventional cardiac procedures per year. Patient dose reports were automatically transferred to a central database. Patients exceeding trigger levels for air kerma area product (500 Gy cm{sup 2}) and cumulative skin dose (5 Gy) were counseled and underwent follow-up for early detection of skin injuries, with dermatologic support. The Ethical Committee and the Quality Assurance and Radiation Safety Committee approved the program. During 2010, a total of 13 patients (3.0/1,000 that year) received dose values exceeding trigger levels in the cardiovascular institute. Only one patient, who had undergone two consecutive procedures resulting in 970 Gy cm{sup 2} and 13.0 Gy as cumulative skin dose, showed signs of serious radiodermatitis that resolved in 3.7 months. The remaining patients did not manifest skin lesions during follow-up, and whenever patient examination was not feasible as part of the follow-up, neither patients nor families reported any skin injuries. Peak skin dose calculation and close clinical follow-up were feasible and appropriate, with a moderate additional workload for the staff and satisfaction for the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Benefit of a New Ophthalmic Radiation Plaque

Purpose: To determine whether the computed dosimetry of a new ophthalmic plaque, EP917, when compared with the standard Collaborative Ocular Melanoma Study (COMS) plaques, could reduce radiation exposure to vision critical structures of the eye. Methods and Materials: One hundred consecutive patients with uveal melanoma treated with COMS radiation plaques between 2007 and 2010 were included in this study. These treatment plans were generated with the use of Bebig Plaque Simulator treatment-planning software, both for COMS plaques and for EP917 plaques using I-125. Dose distributions were calculated for a prescription of 85 Gy to the tumor apex. Doses to the optic disc, opposite retina, lens, and macula were obtained, and differences between the 2 groups were analyzed by standard parametric methods. Results: When compared with the COMS plaques, the EP917 plaques used fewer radiation seeds by an average difference of 1.94 (P<.001; 95% confidence interval [CI], -2.8 to -1.06) and required less total strength of radiation sources by an average of 17.74 U (air kerma units) (P<.001; 95% CI, -20.16 to -15.32). The total radiation doses delivered to the optic disc, opposite retina, and macula were significantly less by 4.57 Gy, 0.50 Gy, and 11.18 Gy, respectively, with the EP917 plaques vs the COMS plaques. Conclusion: EP917 plaques deliver less overall radiation exposure to critical vision structures than COMS treatment plaques while still delivering the same total therapeutic dose to the tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fundamentals of Radiation Dosimetry

The basic concepts of radiation dosimetry are reviewed on basis of ICRU reports and text books. The radiation field is described with, among others, the particle fluence. Cross sections for indirectly ionizing radiation are defined and indicated is how they are related to the mass energy transfer and mass energy absorption coefficients. Definitions of total and restricted mass stopping powers of directly ionizing radiation are given. The dosimetric quantities, kerma, absorbed dose and exposure together with the relations between them are discussed in depth. Finally it is indicated how the absorbed dose can be measured with a calorimeter by measuring the temperature increase and with an ionisation chamber measuring the charge produced by the ionizing radiation and making use of the Bragg-Gray relation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric Characteristics for Brachytherapy Sources

Brachytherapy sources are characterized by the dosimetric parameters in a protocol such as the American Association of Physicists in Medicine Task Group 43. The air-kerma strength is measured and traceable to a primary standard. Then the parameters such as dose-rate constant, radial dose function, and anisotropy function are measured and related back to the primary standard. This is normally accomplished with thermoluminescent dosimeters (TLDs). Since radial dose function and anisotropy function are relative parameters, some of the dosimetric corrections are negligible. For the dose-rate constant, parameters such as the energy dependence compared with a calibration beam such as {sup 60}Co need to be accounted for. A description of the primary standard measurements and TLD measurements will be discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutron Exposure Accelerator System For Biological Effect Experiments (NASBEE)

The neutron exposure accelerator system for biological effect experiments (NASBEE) was developed to study biological effects of fast neutrons. We have characterized the NASBEE neutron beams with neutron energy spectrum, absorbed dose energy distributions, and space distributions. The neutron energy spectrum shows 2.3 MeV as mean energy and 3.0 MeV as kerma of tissue-equivalent-plastic (A150) weighted mean energy, and the maximum neutron energy was determined to be 9 MeV. Neutron absorbed doses occupy 82% of the NASBEE neutron beam. NASBEE has been used to learn some of the outcomes of the biological effects of fast neutrons.

43 PARTICLE ACCELERATORS↗

Neutron dosimetry in solid water phantom

The neutron spectra, the Kerma and the absorbed dose due to neutrons were estimated along the incoming beam in a solid water phantom. Calculations were carried out with the MCNP5 code, where the bunker, the phantom and the model of the15 MV LINAC head were modeled. As the incoming beam goes into the phantom the neutron spectrum is modified and the dosimetric values are reduced.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo simulation of an x-ray luminescence optical tomography scanner prototype

In this work we report the calculation of the deposited energy distribution produced by an x-ray luminescence optical tomography (XLOT) system in a phantom containing different concentrations of Gd{sub 2}O{sub 2}S:Eu nanoparticles. The calculations were performed via Monte Carlo simulation considering spectra from a W target x-ray tube operating between 30 and 90 kVp, with 1.0 mm Al added filtration. CT and XLOT tomographic images were reconstructed from the same data. The results show that XLOT has better detectability than CT alone, that the dose scales linearly with kVp for a fixed concentration of Gd{sub 2}O{sub 2}S:Eu and air-kerma rate, the scattered radiation contribution to the total dose and signal is about 20% and that the dose ratio for a 3 mm diameter insert containing 10 mg/ml Gd{sub 2}O{sub 2}S embedded in a 30 mm diameter water phantom is 6:1. This ratio drops to less than 2:1 for a 1 mg/ml concentration. Finally we show that the method of conjugate images can be used to correct for artifacts due to attenuation effects in XLOT images.

60 APPLIED LIFE SCIENCES↗

Uncertainty Characterization of Silicon Damage Metrics

Here, a general formulation of silicon damage metrics and associated energy-dependent response functions relevant to the radiation effects community is provided. Using this formulation, a rigorous quantitative treatment of the energy-dependent uncertainty contributors is performed. This resulted in the generation of a covariance matrix for the displacement kerma, the NRT-based damage energy, and the 1-MeV(Si) equivalent damage function. Lastly, when a careful methodology is used to apply a reference 1-MeV damage value, the systematic uncertainty in the fast fission region is seen to be removed and the uncertainty for integral metrics in broad-based fission-based neutron fields is demonstrated to be significantly reduced.

1-MeV(Si)↗

The replacement correction factor for the BIPM flat cavity ion chamber and the value of W/e

A graphite flat cavity ionization chamber is used at the BIPM in France to determine the absorbed dose to graphite in a {sup 60}Co photon beam and thereby used to determine the product of the value of W/e, the average energy required to produce an ion pair in dry air, and the value of (L{sub {Delta}}/{rho}){sub a}{sup C}, the mean restricted mass collision stopping-power ratio for graphite to air in a {sup 60}Co beam. The accuracy of the (W/e) (L{sub {Delta}}/{rho}){sub a}{sup C} value thus determined depends upon the accuracy of the perturbation correction factors adopted for this chamber. The perturbation effect of this chamber was accounted for by the replacement correction factor whose value was calculated by an analytical method and confirmed by an EGS4 Monte Carlo calculation. The purpose of this study is to investigate the validity of the analytical and the EGS4 calculations by using recently established methods and the EGSnrc Monte Carlo code, a much improved version of EGS4, to calculate the replacement correction factors for the graphite chamber. It is found that the replacement correction factors used for the BIPM chamber are not correct: the values used are smaller than they should be by about 1%. This leads to a 1% overestimation of the (W/e) (L{sub {Delta}}/{rho}){sub a}{sup C} value determined by using this chamber. This implies that {sup 60}Co air kerma standards that are directly proportional to this product need to be reduced by 1%. Based on the values of the replacement correction factors calculated in this study, and on the value of (L{sub {Delta}}/{rho}){sub a}{sup C} evaluated from ICRU Report No. 37 stopping power for graphite, the value of W/e determined by using the BIPM chamber should be 33.61{+-}0.08 J/C. If a more recent value of mean excitation energy for graphite (86.8 eV) and grain density are used to evaluate the graphite stopping power, then the value obtained for W/e is 34.15{+-}0.08 J/C.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetry characterization of a multibeam radiotherapy treatment for age-related macular degeneration

Age-related macular degeneration (ARMD) is a major health problem worldwide. Advanced ARMD, which ultimately leads to profound vision loss, has dry and wet forms, which account for 20% and 80% of cases involving severe vision loss, respectively. A new device and approach for radiation treatment of ARMD has been recently developed by Oraya Therapeutics, Inc. (Newark, CA). The goal of the present study is to provide a initial dosimetry characterization of the proposed radiotherapy treatment via Monte Carlo radiation transport simulation. A 3D eye model including cornea, anterior chamber, lens, orbit, fat, sclera, choroid, retina, vitreous, macula, and optic nerve was carefully designed. The eye model was imported into the MCNPX2.5 Monte Carlo code and radiation transport simulations were undertaken to obtain absorbed doses and dose volume histograms (DVH) to targeted and nontargeted structures within the eye. Three different studies were undertaken to investigate (1) available beam angles that maximized the dose to the macula target tissue, simultaneously minimizing dose to normal tissues, (2) the energy dependency of the DVH for different x-ray energies (80, 100, and 120 kVp), and (3) the optimal focal spot size among options of 0.0, 0.4, 1.0, and 5.5 mm. All results were scaled to give 8 Gy to the macula volume, which is the current treatment requirement. Eight beam treatment angles are currently under investigation. In all eight beam angles, the source-to-target distance is 13 cm, and the polar angle of entry is 30 degree sign from the geometric axis of the eye. The azimuthal angle changes in eight increments of 45 degree sign in a clockwise fashion, such that an azimuthal angle of 0 degree sign corresponds to the 12 o'clock position when viewing the treated eye. Based on considerations of nontarget tissue avoidance, as well as facial-anatomical restrictions on beam delivery, treatment azimuthal angles between 135 degree sign and 225 degree sign would be available for this treatment system (i.e., directly upward and entering the eye from below). At beam directions approaching 225 degree sign and higher, some dose contribution to the optic nerve would result under the assumption that the optic nerve is tilted cranially above the geometric axis in a given patient, a feature not typically seen in past studies. A total treatment dose of 24 Gy would be delivered in three 8 Gy treatments at these selected azimuthal angles. Dose coefficients, defined as the macula radiation absorbed dose per unit air kerma in units of Gy/Gy, were 16% higher for 120 kVp x-ray beams in comparison to those at 80 kVp, thus requiring only 86% of the integrated tube current (mAs) for equivalent dose delivery. When 0.0, 0.4, and 1.0 mm focal spot sizes were used, the dose profiles in the macula are very similar and relatively uniform, whereas a 5.5 mm focal spot size produced a more nonuniform dose profile. The results of this study demonstrate the therapeutic promise of this device and provide important information for further design and clinical implementation for radiotherapy treatments for ARMD.

61 RADIATION PROTECTION AND DOSIMETRY↗

Determination of absorbed dose in water at the reference point D(r{sub 0},{theta}{sub 0}) for an {sup 192}Ir HDR brachytherapy source using a Fricke system

A ring-shaped Fricke device was developed to measure the absolute dose on the transverse bisector of a {sup 192}Ir high dose rate (HDR) source at 1 cm from its center in water, D(r{sub 0},{theta}{sub 0}). It consists of a polymethylmethacrylate (PMMA) rod (axial axis) with a cylindrical cavity at its center to insert the {sup 192}Ir radioactive source. A ring cavity around the source with 1.5 mm thickness and 5 mm height is centered at 1 cm from the central axis of the source. This ring cavity is etched in a disk shaped base with 2.65 cm diameter and 0.90 cm thickness. The cavity has a wall around it 0.25 cm thick. This ring is filled with Fricke solution, sealed, and the whole assembly is immersed in water during irradiations. The device takes advantage of the cylindrical geometry to measure D(r{sub 0},{theta}{sub 0}). Irradiations were performed with a Nucletron microselectron HDR unit loaded with an {sup 192}Ir Alpha Omega radioactive source. A Spectronic 1001 spectrophotometer was used to measure the optical absorbance using a 1 mL quartz cuvette with 1.00 cm light pathlength. The PENELOPE Monte Carlo code (MC) was utilized to simulate the Fricke device and the {sup 192}Ir Alpha Omega source in detail to calculate the perturbation introduced by the PMMA material. A NIST traceable calibrated well type ionization chamber was used to determine the air-kerma strength, and a published dose-rate constant was used to determine the dose rate at the reference point. The time to deliver 30.00 Gy to the reference point was calculated. This absorbed dose was then compared to the absorbed dose measured by the Fricke solution. Based on MC simulation, the PMMA of the Fricke device increases the D(r{sub 0},{theta}{sub 0}) by 2.0%. Applying the corresponding correction factor, the D(r{sub 0},{theta}{sub 0}) value assessed with the Fricke device agrees within 2.0% with the expected value with a total combined uncertainty of 3.43%(k=1). The Fricke device provides a promising method towards calibration of brachytherapy radiation sources in terms of D(r{sub 0},{theta}{sub 0}) and audit HDR source calibrations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric characterization of a {sup 131}Cs brachytherapy source by thermoluminescence dosimetry in liquid water

Dosimetry measurements of a {sup 131}Cs brachytherapy source have been performed in liquid water employing thermoluminescence dosimeters. A search of the literature reveals that this is the first time a complete set of dosimetric parameters for a brachytherapy ''seed'' source has been measured in liquid water. This method avoids the medium correction uncertainties introduced by the use of water-equivalent plastic phantoms. To assure confidence in the results, four different sources were employed for each parameter measured, and measurements were performed multiple times. The measured dosimetric parameters presented here are based on the AAPM Task Group 43 formalism. The dose-rate constant measured in liquid water was (1.063{+-}0.023) cGy h{sup -1} U{sup -1} and was based on the air-kerma strength standard for this source established by the National Institute of Standards and Technology. Measured values for the 2D anisotropy function and the radial dose function are presented.

61 RADIATION PROTECTION AND DOSIMETRY↗