Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Injection testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

With the increased requirements of real-time grid monitoring, disturbance location, and situation awareness, Phasor Measurement Units (PMUs) have become more critical for the Wide Area Measurement System (WAMS). However, the vulnerability of PMUs has not been well studied, especially under electromagnetic pulse (EMP) scenarios. The stable operation of the power system will be affected directly once EMP damages them. Therefore, studying their immunity to EMP events is urgent and necessary. In this paper, the effective impedance measurement scheme and pulsed current injection (PCI) testing are proposed for the port impedance measurement and immunity levels of PMUs. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then, the circuit of the pulsed current generator is set to generate a damping sinusoid, and the double exponential wave is applied to the port. Finally, using measured impedance as a generator load, the voltage and current responses of different ports are calculated in the PCI testing simulation. In conclusion, results reveal the characteristics of port impedance, waveforms of voltage and current, and distribution of accumulative energy. The relation between port impedance and the waveforms is discussed.

42 ENGINEERING↗

EVSE Characterization: V2G EVSE Comparison

As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.

25 ENERGY STORAGE↗

EGS Collab Experiment 1: Circulation Testing Processed data

This submission includes processed and reduced data for circulation testing that was conducted at the 164' fracture on the 4850 ft level of the Sanford Underground Research Facility. The circulation tests were done to test the flow through the 164' fracture in the EGS Collab Experiment 1 testbed on the 4850 ft level of the Sanford Underground Research Facility in order to validate computer models concerned with flow processes and heat exchange processes in EGS. This data was processed from raw data that is available in the GDR submission linked below: "EGS Collab Circulation Testing Raw Data and Documentation." Python scripts used to process and reduce the data are included. The scripts also serve as "documentation" as well as examples for data processing. More information about the test itself as well as the rationale and process of data processing is available at wiki page linked below.

15 GEOTHERMAL ENERGY↗

Utah FORGE 2-2446: Closing the Loop Between In-Situ Stress Complexity and EGS Fracture Complexity - 2024 Annual Workshop Presentation

This is a presentation on Closing the Loop Between In-Situ Stress Complexity and EGS Fracture Complexity by Lawrence Livermore National Laboratory, presented by Matteo Cusini. The video discusses the combination of high-fidelity simulations and true-triaxial block fracturing tests to explore the intricate relationship between in-situ stress and hydraulic fracture patterns. This presentation was featured in the Utah FORGE R&D Annual Workshop on August 14, 2024.

15 GEOTHERMAL ENERGY↗

Williston Basin Resource Study for Commercial-Scale Subsurface Hydrogen Storage

The Energy & Environmental Research Center (EERC), in partnership with the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL), the EERC’s State Energy Research Center (SERC), MPLX Operations LLC, and TC Energy Development Holdings Inc. (a subsidiary of TC Energy Corporation), studied the potential for subsurface hydrogen storage and recovery in the Williston Basin of western North Dakota. The project’s goal was to evaluate the feasibility of large-scale, secure geologic H 2 storage to support future hydrogen generation, storage, and use. This work included laboratory testing, H 2 –rock–fluid exposure experiments, literature reviews on H 2 embrittlement, and reservoir modeling and simulations. The study included an assessment of storage potential across three types of storage reservoirs using both reservoir simulation and DOE’s web-based tool SHASTA-HELP (Subsurface Hydrogen Assessment, Storage, and Technology Acceleration – Hydrogen Estimator for Logistical Planning), as well as investigation of potential H 2 production and markets for commercial-scale deployment. Building on prior EERC gas storage research, three storage options were selected for detailed evaluation: the Broom Creek Formation (a clastic saline reservoir), the Dickinson Lodgepole Mounds (DLM) complex (carbonate mud mound structures) of the Lodgepole Formation (an active oil and gas producing reservoir), and the Dunham Salt Interval of the Piper Formation (to be used for engineered salt cavern development). These targets were prioritized based on prior EERC research using datasets related to seal capacity, reservoir quality, mechanical integrity, and injectivity. Exposure tests on Broom Creek and DLM samples showed mineral dissolution and precipitation that increased brine salinity and altered reservoir rock surfaces. Although these results provide useful insight, they are limited by small sample sizes and short-term (30-day) exposure, requiring further study to assess long-term storage integrity. Salt formations were not tested because of their known nonreactivity and established mechanical stability. Results of reservoir simulations performed for a single site demonstrated that the Broom Creek Formation may be capable of receiving up to 42,000 tonnes of injected H 2 over 7 months via one well. H 2 recovery took place over 5 months, resulting in approximately 26,000 tonnes (~62% without cushion gas [CG]). This work suggests water production may be important and subsequent cycles of injection and production may perform more efficiently; however, significant site-specific work in the future is needed to assess actual reservoir performance of injection and withdrawal of H 2 storage. For oil reservoir potential, a multiple-well model was used to simulate injection of approximately 32,000 tonnes of H 2 into a single wellbore while simultaneously producing in place reservoir fluids from four offset wells to maintain reservoir pressure. The simulation results suggested a high recovery (~98%); in addition, cost advantages through existing infrastructure could be realized. Challenges in this reservoir include vi managing gas purity and leakage risks. In both scenarios, production of H 2 takes place in a single-well scenario with 10 cycles (7 months of injection and 5 months of production) over 10 years. Finally, the use of engineered caverns in the Dunhan Salt was evaluated, and the results suggest that while they have a smaller capacity (<1000 tonnes per cavern), they exhibit nearly complete gas recovery (>99%), fast response times, and low purity risk. While caverns in North Dakota may be smaller in capacity, fields can be developed in galleries to accommodate the volumetric needs and rapid turnaround times necessary to meet market demands. Geographic limitations and thin salt intervals in North Dakota may represent less total storage potential than salt domes elsewhere, but significant opportunities exist to expand this market for gas storage in North Dakota. A basinwide assessment was performed to estimate a first-of-its-kind value for H 2 storage on a large scale. DOE’s SHASTA-HELP, combined with EERC simulation work, was used to perform the assessment. Estimated H 2 storage potential varied widely for each formation type. The Broom Creek saline formation was estimated to have a storage potential of approximately 1.7–90.5 million tonnes (MMt). The DLM oil reservoirs were estimated to have 0.07–0.19 MMt of capacity. Notably, each of these estimates relies on significant assumptions regarding reservoir thickness, porosity, permeability, and CG needed for operation. Much research is needed to understand the true site-specific storage resource potential of each formation. Using the Dunham Salt Interval for cavern development may result in as much as 4.79 MMt (up to 2.87 MMt working gas) of H 2 storage potential. An important note for consideration is that the values presented here need significantly more geological characterization and engineering assessments prior to gaining confidence in performance. This will be a focal point for future research and development needs. The basinwide evaluation also indicated that North Dakota has significant H 2 generation potential, with estimates up to a possible 13 MMt annually, suggesting a substantial opportunity for H 2 market development and thus the need for commercial-scale H 2 storage to facilitate growth and resilience. Key Recommendations 1. Conduct detailed site characterization (3D seismic, well logs, core sampling) to reduce geologic uncertainty. 2. Perform techno-economic analyses incorporating market, regulatory, and incentive frameworks. 3. Investigate long-term interactions among H 2 , CGs, well materials, and formations to assess risks. 4. Develop pilot- and field-scale demonstrations to validate models and establish best practices.

03 NATURAL GAS↗

Evaluation of Clamshell Current Coupler for Online Frequency Domain and Spread Spectrum Time Domain Reflectometry to Detect Anomalies in Energized Cables

This document describes adaptation and evaluation of a clamshell inductive current coupler for online reflectometry testing (both frequency domain reflectometry and spread spectrum time domain reflectometry) to evaluate cable insulation degradation and anomalies. Safety-critical nuclear power plant cables were initially qualified for 40 years. However, as plants extend their operating licenses to 60 and 80 years, justification for continued safe operation includes test and monitoring programs. These will become more important as the industry moves to condition based qualification programs. Cable test programs traditionally involve manual interventions to disconnect cables, perform one or several tests, then reconnect the systems, usually during refueling outages occurring only every 18 to 24 months. This poses an operational burden that can be minimized by online testing or periodic connection to a coupler that may remain on the cable of interest or be clamped onto the cable without de-termination. This work investigates the adaptation of a clamshell inductive current coupler for either frequency domain reflectometry or spread-spectrum time domain reflectometry. The reflectometry test instrument injects a broad-band chirp or pseudo-noise signal onto a cable conductor and monitors for a reflected signal indicative of an impedance change caused by a damage condition. The instrument maximum input signal levels are typically 10 to 30 volts or less and the instruments will be damaged if subjected to 60 Hz power line voltages of 110, 220, or 480 VAC. One commercial spread-spectrum time domain reflectometry system has circuitry suitable for voltages up to 1 kV, but typical reflectometry tests are performed on de-energized cables. The clamshell inductive coupler provides >60 dB of 60 Hz attenuation with less than 10 dB loss in the 1-500 MHz test bandwidth of interest. An energized cable was successfully tested up to 6.7 kVp-p and frequency response plots imply that the tests could be extended to 10 kV or higher energized levels.

36 MATERIALS SCIENCE↗

Utah FORGE: Well 16A(78)-32 and 16B(78)-32 Stimulation Production Logging Tests

These are production logging tests (PLT) results from Halliburton collected during the nine hour circulation test performed at Utah FORGE on April 27th, 2024. The circulation test involved injecting into well 16A(78)-32 and producing out of well 16B(78)-32) and was carried out after the fracturing of both of those wells. Data attached here includes raw and processed PLT logs from both wells, as well as technical reports summarizing the data collection and results.

15 GEOTHERMAL ENERGY↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of the power system will be affected directly and greatly. Therefore, it is urgent and necessary to study their immunity to electromagnetic pulse (EMP) events. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then circuit of pulsed current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as a load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) testing simulation. Results show that common-mode impedance is large and differential mode impedance is small. The critical condition will appear in the common mode for voltage and differential mode for current.

Zhang, Liang↗

Comparative Performance of Engines Using a Carburetor, Manifold Injection, and Cylinder Injection

The comparative performance was determined of engines using three methods of mixing the fuel and the air: the use of a carburetor, manifold injection, and cylinder injection. The tests were made of a single-cylinder engine with a Wright 1820-G air-cooled cylinder. Each method of mixing the fuel and the air was investigated over a range of fuel-air ratios from 0.10 to the limit of stable operation and at engine speeds of 1,500 and 1,900 r.p.m. The comparative performance with a fuel-air ratio of 0.08 was investigated for speeds from 1,300 to 1,900 r.p.m. The results show that the power obtained with each method closely followed the volumetric efficiency; the power was therefore the highest with cylinder injection because this method had less manifold restriction. The values of minimum specific fuel consumption obtained with each method of mixing of fuel and air were the same. For the same engine and cooling conditions, the cylinder temperatures are the same regardless of the method used for mixing the fuel and the air.

Schey, Oscar W↗

Interpreting strain tensor data to characterize and monitor reservoirs for CO2 storage and other applications

Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and this has opened the door to new opportunities for characterization and monitoring. We have deployed strainmeters and then conducted injection well tests in an underlying reservoir at 530m depth. The resulting data indicated that the horizontal strain at shallow strainmeters (30 to 40m depth) was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 n/d over a few days. The signal at two strainmeters at shallow depth were consistent, although the magnitude of the horizontal strains were different reflecting the different radial directions from the well. The signal at a deep strainmeter deployed at reservoir depth was much different, with tensile vertical strains and compressive horizontal strains. These data can be interpreted by inverting poroelastic forward models developed using numerical and analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. This model is fast and can be inverted to estimate reservoir stiffness and geometry. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. The proxy model is periodically updated and refined using the finite element model to ensure accuracy. This approach significantly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. We have shown that the strain tensor in the caprock is sensitive to pressure in the reservoir, boundaries in the reservoir, and pressure in the caprock caused by leaks. These results indicate that coupling strain tensor data with inversion has the potential to help evaluate reservoirs during initial characterization, and to monitor them during the CO2 injection and storage process.

Murdoch, Larry↗

Design, Analysis, and Experimental Testing of Hydrogen Lean Direct Injection Nozzles at Elevated Pressure

Abstract There are many challenges of commissioning a hydrogen combustor into future gas turbine engines; especially regarding achieving emissions goals. Previously, Escudero et al. and Tran et al. conducted a study to adapt the liquid fuel Lean Direct Injection (LDI) concept from Jet-A to gaseous natural gas-hydrogen blends and pure hydrogen [1], [2]. Experimental data was collected at atmospheric conditions using a Box Behnken design of experiments. The design of experiments suggested that biasing the air split in favor of the inner air circuit and increasing the swirl strength of this inner air passage resulted in improved NOx emissions, while the inverse was true for stability, which was quantified by studying the lean blowoff point (LBO) [1], [2]. The trends revealed by the original experiment [1], [2] provided a design direction for further iterations of the experimental hardware. The study presented herein describes the further investigation of such LDI injectors through experimental methods and computational fluid dynamic (CFD) simulations at atmospheric conditions, which were used to identify potential flow behaviors driving enhanced emissions performance. Further evaluation of select injectors from both studies was then conducted at elevated pressures up to 6 atmospheres. The results from both experiments are presented in this study, which include flame observations, emissions measurements, and operational challenges. NOx emissions results are reported on a volume basis in ppmvd corrected to 15% O2 and corrected for fuel. A predictive model for relating NOx emissions to test conditions at atmospheric conditions show high significance to adiabatic flame temperature while little to no significance to fuel composition for the best performing configurations. The results illustrate the connection between atmospheric testing and testing elevated pressures. The design direction indicated by the initial tests and CFD results in promising configurations for implementation into a Multi-point LDI array.

08 HYDROGEN↗

Pixel response characterization of the ARCADIA fully depleted MAPS

Monolithic Active Pixel Sensors (MAPS) achieved widespread use in several scientific applications, thanks to their properties, such as low material budget and high granularity. The ARCADIA INFN project developed a Fully-Depleted MAPS (FD-MAPS), using a modified LFoundry 110 nm CIS process. This work presents the first laboratory characterization of the ARCADIA MD3 prototype. Measurements include threshold uniformity studies using both test-pulse injection and a 55 Fe source, as well as threshold and noise calibration achieved thanks to monochromatic X-ray sources. Ultimately, charge-collection efficiency is evaluated using an infrared laser setup.

Particle tracking detectors↗

Sub-m s−1 upper limits from a deep HARPS-N radial-velocity search for planets orbiting HD 166620 and HD 144579

ABSTRACT Minimizing the impact of stellar variability in radial velocity (RV) measurements is a critical challenge in achieving the 10 cm s−1 precision needed to hunt for Earth twins. Since 2012, a dedicated programme has been underway with HARPS-N, to conduct a blind RV rocky planets search (RPS) around bright stars in the Northern hemisphere. Here we describe the results of a comprehensive search for planetary systems in two RPS targets, HD 166620 and HD 144579. Using wavelength-domain line-profile decorrelation vectors to mitigate the stellar activity and performing a deep search for planetary reflex motions using a trans-dimensional nested sampler, we found no significant planetary signals in the data sets of either of the stars. We validated the results via data-splitting and injection recovery tests. Additionally, we obtained the 95th percentile detection limits on the HARPS-N RVs. We found that the likelihood of finding a low-mass planet increases noticeably across a wide period range when the inherent stellar variability is corrected for using scalpelsU-vectors. We are able to detect planet signals with Msin i ≤ 1 M⊕ for orbital periods shorter than 10 d. We demonstrate that with our decorrelation technique, we are able to detect signals as low as 54 cm s−1, which brings us closer to the calibration limit of 50 cm s−1 demonstrated by HARPS-N. Therefore, we show that we can push down towards the RV precision required to find Earth analogues using high-precision radial velocity data with novel data-analysis techniques.

Anna John, A. (ORCID:0000000217156939)↗

Optimal Power Hardware-in-the-Loop Interfacing: Applying Modern Control For Design and Verification of High-Accuracy Interfaces

Here, we develop a novel approach to designing power hardware-in-the-loop (PHIL) simulation interfaces that maximizes simulation bandwidth and accuracy by leveraging a modern control framework that explicitly considers objectives on accuracy and can automatically synthesize an optimal controller that meets these objectives while stabilizing the closed-loop system. The method developed improves upon common approaches to PHIL interface design that typically involve multiple design steps for manual compensation and stabilization design that can result in interfaces that are stable but have suboptimal bandwidth and accuracy. The approach developed is general and can be applied to most PHIL system configurations. The modeling framework allows for the inclusion of scaling factors and hardware-under-test current injection models that are common to practical PHIL simulations and have significant impacts on stability. We also present practical methods and metrics for verifying the absolute accuracy of PHIL simulation results without relying on relative comparisons to potentially inaccurate models or previous simulation results. We demonstrate the accuracy evaluation method and show the improved performance achievable when using the optimal PHIL interface design approach in an experimental case study involving a 100-kVA battery inverter.

42 ENGINEERING↗

Utah FORGE: Well 16A(78)-32 Planned Trajectory

This submission includes an Excel spreadsheet containing the Utah FORGE deep well 16A(78)-32 planned trajectory including UTM coordinates, elevations, and depths from the well head to the toe. This proposed new injection well is expected to descend vertically to a depth of approximately 1810 m and then extend laterally at an angle to a MD of approximately 3290 m and a maximum vertical depth of approximately 2584 m. There is approximately 1500 m of basin fill at the well head, and less than that above the simulation region with the targeted reservoir region fully enclosed in granitoid basement. The last 60 m of the well will be open hole. Drilling is planned for October 2020. Please direct questions to the Utah FORGE team: utahforge@utah.edu and check the Utah FORGE website: https://utahforge.com after October for more information.

15 GEOTHERMAL ENERGY↗

Environmental Impact Calculations for Geothermal DDU system on WVU Campus

This dataset contains all the inputs used and output produced from Matlab for the environmental analysis of an improved hybrid geothermal district heating and cooling (GDHC) system with a heat pump, without a heat pump, and for a hot water GDHC. Detailed descriptions of the contents of this repository are provided below.

15 GEOTHERMAL ENERGY↗

EGS Collab Modeling and Simulation Working Group Teleconference Series (1-98)

This submission contains the presentation slides and recordings from the first 98 EGS Collab Modeling and Simulation Working Group teleconferences. These teleconferences served three objectives for the project: 1) share simulation results, 2) communicate field activities and results to the simulation teams, and 3) hold open scientific discussions on EGS topics.

15 GEOTHERMAL ENERGY↗