Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Infrared techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Investigation of PTFE transfer films by infrared emission spectroscopy and phase-locked ellipsometry

When a PTFE sheet was rubbed unidirectionally over a smooth surface of stainless steel an essentially monomolecular transfer film was formed. by ellipsometric and emission infrared spectroscopic techniques it was shown that the film was 10 to 15 A thick and birefringent. From the intensity differences of infrared bands obtained with a polarizer passing radiation polarized in mutually perpendicular planes, it was possible to deduce transfer film orientation with the direction of rubbing. After standing in air for several weeks the transfer films apparently increased in thickness by as much as threefold. At the same time both the index of refraction and the absorption index decreased. Examination of the surfaces by optical and electron microscopies showed that the films had become porous and flaky. These observations were consistent with previous tribological measurements. The coefficients of friction decreased with the formation of the transfer film but increased again as the film developed breaks. The applicability of the ellipsometric and polarized infrared emission techniques to the identification of monomolecular tribological transfer films of polymers such as PTFE has been demonstrated.

Lauer, James L.↗

Analysis techniques for two-dimensional infrared data

In order to evaluate infrared detection and remote sensing systems, it is necessary to know the characteristics of the observational environment. For both scanning and staring sensors, the spatial characteristics of the background may be more of a limitation to the performance of a remote sensor than system noise. This limitation is the so-called spatial clutter limit and may be important for systems design of many earth application and surveillance sensors. The data used in this study is two dimensional radiometric data obtained as part of the continuing NASA remote sensing programs. Typical data sources are the Landsat multi-spectral scanner (1.1 micrometers), the airborne heat capacity mapping radiometer (10.5 - 12.5 micrometers) and various infrared data sets acquired by low altitude aircraft. Techniques used for the statistical analysis of one dimensional infrared data, such as power spectral density (PSD), exceedance statistics, etc. are investigated for two dimensional applicability. Also treated are two dimensional extensions of these techniques (2D PSD, etc.), and special techniques developed for the analysis of 2D data.

Winter, E. M.↗

A comparison of techniques for extracting emissivity information from thermal infrared data for geologic studies

This article evaluates three techniques developed to extract emissivity information from multispectral thermal infrared data. The techniques are the assumed Channel 6 emittance model, thermal log residuals, and alpha residuals. These techniques were applied to calibrated, atmospherically corrected thermal infrared multispectral scanner (TIMS) data acquired over Cuprite, Nevada in September 1990. Results indicate that the two new techniques (thermal log residuals and alpha residuals) provide two distinct advantages over the assumed Channel 6 emittance model. First, they permit emissivity information to be derived from all six TIMS channels. The assumed Channel 6 emittance model only permits emissivity values to be derived from five of the six TIMS channels. Second, both techniques are less susceptible to noise than the assumed Channel 6 emittance model. The disadvantage of both techniques is that laboratory data must be converted to thermal log residuals or alpha residuals to facilitate comparison with similarly processed image data. An additional advantage of the alpha residual technique is that the processed data are scene-independent unlike those obtained with the other techniques.

Hook, Simon J.↗

Point source detection in infrared astronomical surveys

Data processing techniques useful for infrared astronomy data analysis systems are reported. This investigation is restricted to consideration of data from space-based telescope systems operating as survey instruments. In this report the theoretical background for specific point-source detection schemes is completed, and the development of specific algorithms and software for the broad range of requirements is begun.

Pelzmann, R. F., Jr.↗

Diagnosis of separated flow regions on wind-tunnel models using an infrared camera

A novel technique utilizing an infrared-sensitive imaging camera has been used to determine the location of three-dimensional (3-D) separated flow regions on an inclined 5 deg semiangle fiberglass cone. The results illustrate that there is a change in the contrast of the infrared (IR) signature on the cone surface corresponding with the location where the skin-friction lines merge toward lines of 3-D separation. This technique should offer a convenient means for locating separated flow regions on wind-tunnel models while obtaining simultaneous force, skin-friction, and pressure data.

Bandettini, A.↗

Optical metrology for testing an all-composite 2-meter diameter mirror

The Herschel Space Observatory (formerly known as FIRST) consists of a 3.5 m space telescope designed for use in the long IR and sub-milimeter wavebands. To demonstrate the viability of a carbon fiber composite telescope for this application, Composite Optics Incorporated (COI) manufactured a fast (f/1), large (2 m), lightweight (10.1 kg/m squared) demonstration mirror. A key challenge in demonstrating the performance of this novel mirror was to characterize the surface accuracy at cryogenic (70 K) temperatures. A wide variety of optical metrology techniques were investigated and a brief survey of empirical test results and limitations of the various techniques will be presented in this paper. Two complementary infrared (IR)techniques operating at a wavelength of 10.6 microns were chosen for further development: (1) IR Twyman-Green Phase Shifting Interferometry (IR PSI) and (2) IR Shack-Hartmann (IR SH) Wavefront Sensing. Innovative design modifications made to an existing IR PSI to achieve high-resolution, scannable, infrared measurements of the composite mirror are described. The modified interferometer was capable of measuring surface gradients larger than 350 microradians. The design and results of measurements made with a custom-built IR SH Wavefrong Sensor operating at 10.6 microns are also presented. A compact experimental setup permitting simultaneous operation of both the IR PSI and IR SH tools is shown. The advantages and the limitations of the two key IR metrology tools are discussed.

IR metrology phase shifting interferometry Shack-H↗

Microwave, Millimeter, Submillimeter, and Far Infrared Spectral Databases

The spectrum of most known astrophysical molecules is derived from transitions between a few hundred to a few hundred thousand energy levels populated at room temperature. In the microwave and millimeter wave regions. spectroscopy is almost always performed with traditional microwave techniques. In the submillimeter and far infrared microwave technique becomes progressively more technologically challenging and infrared techniques become more widely employed as the wavelength gets shorter. Infrared techniques are typically one to two orders of magnitude less precise but they do generate all the strong features in the spectrum. With microwave technique, it is generally impossible and rarely necessary to measure every single transition of a molecular species, so careful fitting of quantum mechanical Hamiltonians to the transitions measured are required to produce the complete spectral picture of the molecule required by astronomers. The fitting process produces the most precise data possible and is required in the interpret heterodyne observations. The drawback of traditional microwave technique is that precise knowledge of the band origins of low lying excited states is rarely gained. The fitting of data interpolates well for the range of quantum numbers where there is laboratory data, but extrapolation is almost never precise. The majority of high resolution spectroscopic data is millimeter or longer in wavelength and a very limited number of molecules have ever been studied with microwave techniques at wavelengths shorter than 0.3 millimeters. The situation with infrared technique is similarly dire in the submillimeter and far infrared because the black body sources used are competing with a very significant thermal background making the signal to noise poor. Regardless of the technique used the data must be archived in a way useful for the interpretation of observations.

Pearson, J. C.↗

Infrared Heterodyne Spectroscopy and its Unique Application to Planetary Studies

Since the early 1970's the infrared heterodyne technique has evolved into a powerful tool for the study of molecular constituents, temperatures, and dynamics in planetary atmospheres. Its extremely high spectral resolution (Lambda/(Delta)Lambda/>10(exp 6)) and highly accurate frequency measurement (to 1 part in 10(exp 8)) enabled the detection of nonthermal/natural lasing phenomena on Mars and Venus; direct measurements of winds on Venus, Mars, and Titan; study of mid-infrared aurorae on Jupiter; direct measurement of species abundances on Mars (ozone, isotopic CO2), hydrocarbons on Jupiter, Saturn., Neptune, and Titan, and stratospheric composition in the Earth's stratosphere (O3, CIO, N2O, CO2 ....). Fully resolved emission and absorption line shapes measured by this method enabled the unambiguous retrieval of molecular abundances and local temperatures and thermal structure in regions not probed by other techniques. The mesosphere of Mars and thermosphere of Venus are uniquely probed by infrared heterodyne spectroscopy. Results of these studies tested and constrained photochemical and dynamical theoretical models describing the phenomena measured. The infrared heterodyne technique will be described. Highlights in its evolution to today's instrumentation and resultant discoveries will be presented, including work at Goddard Space Flight Center and the University of Koln. Resultant work will include studies supporting NASA and ESA space missions and collaborations between instrumental and theoretical groups.

Kostiuk, Theodore↗

Nanotechnology Infrared Optics for Astronomy Missions

The program "Nanotechnology Infrared Optics for Astronomy Missions" will design and develop new, nanotechnology techniques for infrared optical devices suitable for use in NASA space missions. The proposal combines expertise from the Smithsonian Astrophysical Observatory, the Naval Research Laboratory, the Goddard Space Flight Center, and the Physics Department at the Queen Mary and Westfield College in London, now relocated to the University of Cardiff, Cardiff, Wales. The method uses individually tailored metal grids, and layered stacks of metal mesh grids, both inductive (free-standing) and capacitive (substrate-mounted), to produce various kinds of filters. The program has the following goals: (1) Model FIR filter properties using electric-circuit analogs, and near-field, EM diffraction calculations; (2) Prototype fabrication of meshes on various substrates, with various materials, and of various dimensions; (3) Test of filter prototypes, and iterate with the modeling programs; (4) Travel to related sites, including trips to Washington, D.C. (location of NRL and GSFC), London (location of QMW), Cardiff, Wales, and Rome (location of ISO PMS project headquarters); (5) Produce ancillary science, including publication of both testing on mesh performance and infrared astronomical science.

Smith, Howard A.↗

Nanotechnology Infrared Optics for Astronomy Missions

The program "Nanotechnology Infrared Optics for Astronomy Missions" will design and develop new, nanotechnology techniques for infrared optical devices suitable for use in NASA space missions. The proposal combines expertise from the Smithsonian Astrophysical Observatory, the Naval Research Laboratory, the Goddard Space Flight Center, and the Physics Department at the Queen Mary and Westfield College in London, now relocated to the University of Cardiff, Cardiff, Wales. The method uses individually tailored metal grids and layered stacks of metal mesh grids, both inductive (freestanding) and capacitive (substrate-mounted), to produce various kinds of filters. The program has the following goals: 1) Model FIR filter properties using electric-circuit analogs and near-field, EM diffraction calculations. 2) Prototype fabrication of meshes on various substrates, with various materials, and of various dimensions. 3) Test filter prototypes and iterate with the modeling programs. 4) Travel to related sites, including trips to Washington, D.C. (location of NRL and GSFC), London (location of QMW), Cardiff, Wales, and Rome (location of ISO PMS project headquarters). 5) Produce ancillary science, including both publication of testing on mesh performance and infrared astronomical science.

Smith, Howard A.↗

Exploration of the Saturn System by the Cassini Mission: Observations with the Cassini Infrared Spectrometer

The Cassini mission is a joint NASA-ESA international mission, launched on October 17, 1997 with 12 instruments on board, for exploration of the Saturn system. A composite Infrared Spectrometers is one of the major instruments. Successful insertion of the spacecraft in Saturn's orbit for an extended orbital tour occurred on July 1, 2004. The French Huygens-Probe on board, with six instruments was programmed for a soft landing on Titan's surface occurred in January 2005. The broad range scientific objectives of the mission are: Exploration of the Saturn system for investigations of the origin, formation, & evolution of the solar system, with an extensive range of measurements and the analysis of the data for scientific interpretations. The focus of research dealing with the Cassini mission at NASA/MSFC in collaboration with the NASA/Goddard Space Flight Center, JPL, as well as the research teams at Oxford/UK and Meudon Observatory/France, involves the Infrared observations of Saturn and its satellites, for measurements of the thermal structure and global distributions of the atmospheric constituents. A brief description of the Cassini spacecraft, the instruments, the objectives, in particular with the infrared observations of the Saturn system will be given. The analytical techniques for infrared radiative transfer and spectral inversion programs, with some selected results for gas constituent distributions will be presented.

Abbas, Mian M.↗

Hyperspectral and Nanosecond Temporal Resolution Widefield Infrared Photothermal Heterodyne Imaging

Label-free, bond-selective imaging offers new opportunities for fundamental and applied studies in chemistry, biology, and materials science. Preventing its broader application to investigating spectrally congested specimens are issues related to low sensitivity as well as low spatial and temporal resolution. Here, we demonstrate a widefield, mid-infrared (MIR) photothermal imaging technique, called widefield Infrared Photothermal Heterodyne imaging (wIR-PHI), that massively parallelizes acquisition of MIR absorption data through use of a high-speed complementary metal-oxide-semiconductor camera. wIR-PHI possesses notable features that include: spatial resolution significantly below the MIR diffraction limit, hyperspectral imaging capabilities, high sensitivity, and ~100 ns temporal resolution. Here, the first two features are highlighted by hyperspectral imaging of proximally close poly(methyl methacrylate) (PMMA) and polystyrene (PS) nanoparticles where clear, bond-specific imaging of nanoparticles, separated by less than the MIR diffraction limit, is demonstrated. Sensitivity is highlighted by imaging individual PMMA and PS nanoparticles with radii between r = 97-556 nm. This leads to a current, peak absorption cross-section limit-of-detection of σ abs = 1.9× 10 –16 cm 2 . wIR-PHI's 100 ns temporal resolution is simultaneously demonstrated by observing the decay of photothermal contrast on individual nanoparticles on a ~200-6000 ns timescale. In whole, wIR-PHI’s dramatic increase in acquisition speed opens opportunities for future MIR kinetic imaging and spectroscopic studies of important chemical, biological, and material processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Focal plane optics in far-infrared and submillimeter astronomy

The construction of airborne observatories, high mountain-top observatories, and space observatories designed especially for infrared and submillimeter astronomy has opened fields of research requiring new optical techniques. A typical far-IR photometric study involves measurement of a continuum spectrum in several passbands between approx 30 microns and 1000 microns and diffraction-limited mapping of the source. At these wavelengths, diffraction effects strongly influence the design of the field optics systems which couple the incoming flux to the radiation sensors (cold bolometers). The Airy diffraction disk for a typical telescope at submillimeter wavelengths approx 100 microns-1000 microns is many millimeters in diameter; the size of the field stop must be comparable. The dilute radiation at the stop is fed through a Winston nonimaging concentrator to a small cavity containing the bolometer. The purpose of this paper is to review the principles and techniques of infrared field optics systems, including spectral filters, concentrators, cavities, and bolometers (as optical elements), with emphasis on photometric systems for wavelengths longer than 60 microns.

Hildebrand, R. H.↗

Focal plane optics in far-infrared and submillimeter astronomy

The construction of airborne observatories, high mountain-top observatories, and space observatories designed especially for infrared and submillimeter astronomy has opened fields of research requiring new optical techniques. A typical far-IR photometric study involves measurement of a continuum spectrum in several passbands between approx 30 microns and 1000 microns and diffraction-limited mapping of the source. At these wavelengths, diffraction effects strongly influence the design of the field optics systems which couple the incoming flux to the radiation sensors (cold bolometers). The Airy diffraction disk for a typical telescope at submillimeter wavelengths approx 100 microns-1000 microns is many millimeters in diameter; the size of the field stop must be comparable. The dilute radiation at the stop is fed through a Winston nonimaging concentrator to a small cavity containing the bolometer. The purpose of this paper is to review the principles and techniques of infrared field optics systems, including spectral filters, concentrators, cavities, and bolometers (as optical elements), with emphasis on photometric systems for wavelengths longer than 60 microns.

Hildebrand, R. H.↗

Near-field infrared microscopy: A novel analytic mapping technique to nanocharacterize calcium silicate-based cement materials

Infrared imaging via scattering-type scanning near-field optical microscopy (s-SNOM) allows chemical mapping of organic and inorganic materials with nanoscale spatial resolution. However, its potential adaptation to the complex multiphase structure of Portland cement is yet to be explored. Here we demonstrate the successful implementation of s-SNOM to spatially resolve coexisting chemical phases in tricalcium silicate, Portland cement's main compound, with 20-nm resolution. We found that s-SNOM is sensitive to different anhydrous polymorphic phases, revealing nanoscale domains that are ‘invisible’ to other microscopic techniques. Furthermore, s-SNOM's ability to distinguish the unhydrated and hydrated phases signifies its great promise as an analytical tool to study the complex hydration process of cement. The key to s-SNOM's application was nano-modifying the surface roughness of the cement samples, allowing nanoscale infrared imaging without topographical artifacts. Our study opens a window for infrared spectral microscopy in cement and other porous inorganic materials.

36 MATERIALS SCIENCE↗

A sensitive infrared imaging up converter and spatial coherence of atmospheric propagation

An infrared imaging technique based on the nonlinear interaction known as upconversion was used to obtain images of several astronomical objects in the 10 micrometer spectral region, and to demonstrate quantitatively the sharper images allowed for wavelengths beyond the visible region. The deleterious effects of atmospheric inhomogeneities on telescope resolution were studied in the infrared region using the technique developed. The low quantum efficiency of the device employed severely limited its usefulness as an astronomical detector.

Boyd, R. W.↗

Flash Infrared Thermography Contrast Data Analysis Technique

This paper provides information on an IR Contrast technique that involves extracting normalized contrast versus time evolutions from the flash thermography inspection infrared video data. The analysis calculates thermal measurement features from the contrast evolution. In addition, simulation of the contrast evolution is achieved through calibration on measured contrast evolutions from many flat-bottom holes in the subject material. The measurement features and the contrast simulation are used to evaluate flash thermography data in order to characterize delamination-like anomalies. The thermal measurement features relate to the anomaly characteristics. The contrast evolution simulation is matched to the measured contrast evolution over an anomaly to provide an assessment of the anomaly depth and width which correspond to the depth and diameter of the equivalent flat-bottom hole (EFBH) similar to that used as input to the simulation. A similar analysis, in terms of diameter and depth of an equivalent uniform gap (EUG) providing a best match with the measured contrast evolution, is also provided. An edge detection technique called the half-max is used to measure width and length of the anomaly. Results of the half-max width and the EFBH/EUG diameter are compared to evaluate the anomaly. The information provided here is geared towards explaining the IR Contrast technique. Results from a limited amount of validation data on reinforced carbon-carbon (RCC) hardware are included in this paper.

Koshti, Ajay↗