Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

In situ visualization of multicomponents coevolution in a battery pouch cell

Lithium-ion battery (LIB) is a broadly adopted technology for energy storage. With increasing demands to improve the rate capability, cyclability, energy density, safety, and cost efficiency, it is crucial to establish an in-depth understanding of the detailed structural evolution and cell-degradation mechanisms during battery operation. Here, we present a laboratory-based high-resolution and high-throughput X-ray micro–computed laminography approach, which is capable of in situ visualizing of an industry-relevant lithium-ion (Li-ion) pouch cell with superior detection fidelity, resolution, and reliability. This technique enables imaging of the pouch cell at a spatial resolution of 0.5 μm in a laboratory system and permits the identification of submicron features within cathode and anode electrodes. We also demonstrate direct visualization of the lithium plating in the imaged pouch cell, which is an important phenomenon relevant to battery fast charging and low-temperature cycling. Our development presents an avenue toward a thorough understanding of the correlation among multiscale structures, chemomechanical degradation, and electrochemical behavior of industry-scale battery pouch cells.

25 ENERGY STORAGE↗

Characterization of Lab-Grown Cracks for Aerosol Transmission Testing

Motivation: Determine the length and opening of two lab-grown cracks, designated as LT-14 and LT-28, representative of stress corrosion cracks in spent nuclear fuel dry storage casks to supplement future testing of gas and aerosol transport. Problem: The extreme aspect ratio of the crack length to opening requires that imaging occurs in stages with the results merged before final analysis. Method: High magnification (1500x) optical images of both sides of the two plates were acquired. 20x stitched images with LSCM were acquired, fully stitched along the length, and leveled with newly developed PLATES Method in MATLAB®. Conclusion for LT-14: Side 1 is 47.25 mm long and has 366 separate crack features with an average length of 23.50 µm and an average opening of 8.27 µm. Side 2 is 69.44 mm long and has 550 separate crack features with an average length of 81.63 µm and an average opening of 67.70 µm. Conclusion for LT-28: Side 1 is 71.95 mm long and has 1,127 separate crack features with an average length of 42.27 µm and an average opening of 10.31 µm. Side 2 is 74.88 mm long and has 520 separate crack features with an average length of 98.13 µm and an average opening of 14.99 µm. The adjacent crack on side 1 is 18.95 mm long and has 37 separate crack features with an average length of 17.46 µm and an average opening of 10.42 µm. The adjacent crack on side 2 is 26.40 mm long and has 55 separate crack features with an average length of 87.26 µm and an average opening of 48.29 µm. Each adjacent crack is approximately 26 mm from the main crack.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Path-Integrated X-Ray Images for Multi-Surface Digital Image Correlation (PI-DIC)

X-ray imaging offers unique possibilities for Digital Image Correlation (DIC), opening the door for full-field deformation measurements of a test article in complex environments where optical DIC suffers severe biases or is impossible. While X-ray DIC has been performed in the past with standard DIC codes designed for optical images, the path-integrated nature of X-ray images places constraints on the experimental setup, predominantly that only a single surface of interest moves/deforms. These requirements are difficult to realize for many practical situations and limit the amount of information that can be garnered in a single test. Other X-ray based diagnostics such as Digital Volume Correlation (DVC) and Projection DVC (P-DVC) overcome these obstacles, but DVC is limited to quasi-static tests, and both DVC and P-DVC necessitate high-resolution computed tomography (CT) scan(s) and often require a potentially invasive pattern throughout the volume of the specimen. Here this work presents a novel approach to measure time-resolved displacements and strains on multiple surfaces from a single series of 2D, path-integrated (PI) X-ray images, called PI-DIC. The principle of optical flow or conservation of intensity—the foundation of DIC—was reframed for path-integrated images, for an exemplar setup comprised of two plates moving and deforming independently. Synthetic images were generated for rigid translations, rigid rotations, and uniform stretches, where each plate underwent a unique motion/deformation. Experimental specimens were fabricated (either an aluminum plate with tantalum features or a plastic plate with steel features) and the two specimens were independently translated. PI-DIC was successfully demonstrated with the synthetic images and validated with the experimental images. Prescribed displacements were recovered for each plate from the single set of path-integrated, deformed images. Errors were approximately 0.02 px for the synthetic images with 1.5% image noise, and 0.05 px for the experimental images. These results provide the foundation for PI-DIC to measure motion and deformation of multiple, independent surfaces with subpixel accuracy from a single series of path-integrated X-ray images.

47 OTHER INSTRUMENTATION↗

Charges on a suspended silicon nitride membrane under a high-energy electron beam

Thin silicon nitride (SiN x ) membranes are widely used in gas and liquid phase transmission electron microscopy (TEM) and as phase plates to enhance imaging contrast. SiN x contains trap sites for both positive and negative charges, which can be manipulated by high-energy electron irradiation, external potential biasing, or light exposure. Charge accumulation on the membrane can significantly affect in situ TEM processes, including chemical and electrochemical reactions, nanoparticle dynamics, and catalytic activity, or introduce unwanted phase shifts when used as a phase plate. Here, in this study, charge accumulation on suspended SiN x membranes was investigated using off-axis electron holography combined with model-free charge analysis, supported by custom finite element analysis (FEA) simulations. An average residual positive charge density of approximately 2.8 × 10 −4 C m −2 was measured. Localized and stable regions of both positive and negative charges were identified on the membrane. The global positive and localized positive/negative charges give rise to strong electric fields and electroosmotic slip velocities at the membrane surface, which are sufficient to induce non-Brownian particle behavior and directional fluid flow, offering a physical explanation for previously observed anomalies in particle dynamics, nucleation, and growth during gas and liquid phase TEM experiments. These results provide a benchmark for understanding charge behavior at SiNx interfaces in gas and liquid phase TEM. Furthermore, the FEA simulations establish a framework for future investigations into charge distribution, electrostatic potentials, and electrical double layers at solid–liquid interfaces, particularly in complex geometries and chemically dynamic environments.

Suspended silicon↗

Digital Mammography with a Mosaic of CCD-Arrays

The present invention relates generally to a mammography device and method and more particularly to a novel digital mammography device and method to detect microcalcifications of precancerous tissue. A digital mammography device uses a mosaic of electronic digital imaging arrays to scan an x-ray image. The mosaic of arrays is repositioned several times to expose different portions of the image, until the entire image is scanned. The data generated by the arrays during each exposure is stored in a computer. After the final exposure, the computer combines data of the several partial images to produce a composite of the original x-ray image. An aperture plate is used to reduce scatter and the overall exposure of the patient to x-rays. The novelty of this invention is that it provides a digital mammography device with large field coverage, high spatial resolution, scatter rejection, excellent contrast characteristics and lesion detectability under clinical conditions. This device also shields the patient from excessive radiation, can detect extremely small calcifications and allows manipulation and storage of the image.

Jalink, Antony, Jr.↗

Critical range evaluation using a diagonal flat plate

A novel technique is presented to image stray signals in RCS measurement ranges. In this technique, the scattered fields of a flat plate in the diagonal plane are measured in a range for various frequencies and look angles. The scattered field data is then processed to generate an inverse synthetic aperture radar (ISAR) image of the diagonal flat plate. It is shown that scattering mechanisms associated with various stray signals can be identified by using the ISAR image. This leads to better understanding of the range and possible chamber improvements. Scattering mechanisms as small as 90 dB below the plate broadside scattered field level have been observed in the image domain due to the high directivity and low sidelobe characteristics associated with the diagonal flat plate backscattered fields. The results obtained from evaluating the two compact range facilities at The Ohio State University ElectroScience Laboratory are presented to illustrate the virtues of this new range evaluation technique.

Lee, Teh-Hong↗

Delamination Detection Using Guided Wave Phased Arrays

This paper presents a method for detecting multiple delaminations in composite laminates using non-contact phased arrays. The phased arrays are implemented with a non-contact scanning laser Doppler vibrometer (SLDV). The array imaging algorithm is performed in the frequency domain where both the guided wave dispersion effect and direction dependent wave properties are considered. By using the non-contact SLDV array with a frequency domain imaging algorithm, an intensity image of the composite plate can be generated for delamination detection. For the proof of concept, a laboratory test is performed using a non-contact phased array to detect two delaminations (created through quasi-static impact test) at different locations in a composite plate. Using the non-contact phased array and frequency domain imaging, the two impact-induced delaminations are successfully detected. This study shows that the non-contact phased array method is a potentially effective method for rapid delamination inspection in large composite structures.

Tian, Zhenhua↗

Vision Algorithm for the Solar Aspect System of the High Energy Replicated Optics to Explore the Sun Mission

This work covers the design and test of a machine vision algorithm for generating high- accuracy pitch and yaw pointing solutions relative to the sun on a high altitude balloon. It describes how images were constructed by focusing an image of the sun onto a plate printed with a pattern of small cross-shaped fiducial markers. Images of this plate taken with an off-the-shelf camera were processed to determine relative position of the balloon payload to the sun. The algorithm is broken into four problems: circle detection, fiducial detection, fiducial identification, and image registration. Circle detection is handled by an "Average Intersection" method, fiducial detection by a matched filter approach, and identification with an ad-hoc method based on the spacing between fiducials. Performance is verified on real test data where possible, but otherwise uses artificially generated data. Pointing knowledge is ultimately verified to meet the 20 arcsecond requirement.

0000000↗

X-ray imaging of Rayleigh–Taylor instabilities using Fresnel zone plate at the National Ignition Facility

Being able to provide high-resolution x-ray radiography is crucial in order to study hydrodynamic instabilities in the high-energy density regime at the National Ignition Facility (NIF). Current capabilities limit us to about 20 μm resolution using pinholes, but recent studies have demonstrated the high-resolution capability of the Fresnel zone plate optics at the NIF, measuring 2.3 μm resolution. Using a zinc Heα line at 9 keV as a backlighter, we obtained a radiograph of Rayleigh–Taylor instabilities with a measured resolution of under 3 μm. Two images were taken with a time integrated detector and were time gated by a laser pulse duration of 600 ps, and a third image was taken with a framing camera with a 100 ps time gate on the same shot and on the same line of sight. The limiting factors on image quality for these two cases are the motion blur and the signal to noise ratio, respectively. We also suggest solutions to increase the image quality.

Do, A. (ORCID:0000000174372147)↗

Research study on stellar X-ray imaging experiment, volume 1

The use of microchannel plates as focal plane readout devices and the evaluation of mirrors for X-ray telescopes applied to stellar X-ray imaging is discussed. The microchannel plate outputs were either imaged on a phosphor screen which was viewed by a low light level vidicon or on a wire array which was read out by digitally processing the output of a charge division network attached to the wires. A service life test which was conducted on two image intensifiers is described.

Wilson, H. H.↗

Workflow for High-throughput Screening of Enzyme Mutant Libraries Using Matrix-assisted Laser Desorption/Ionization Mass Spectrometry Analysis of Escherichia coli Colonies

High-throughput molecular screening of microbial colonies and DNA libraries are critical procedures that enable applications such as directed evolution, functional genomics, microbial identification, and creation of engineered microbial strains to produce high-value molecules. A promising chemical screening approach is the measurement of products directly from microbial colonies via optically guided matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Measuring the compounds from microbial colonies bypasses liquid culture with a screen that takes approximately 5 s per sample. We describe a protocol combining a dedicated informatics pipeline and sample preparation method that can prepare up to 3,000 colonies in under 3 h. The screening protocol starts from colonies grown on Petri dishes and then transferred onto MALDI plates via imprinting. The target plate with the colonies is imaged by a flatbed scanner and the colonies are located via custom software. The target plate is coated with MALDI matrix, MALDI-MS analyzes the colony locations, and data analysis enables the determination of colonies with the desired biochemical properties. This workflow screens thousands of colonies per day without requiring additional automation. The wide chemical coverage and the high sensitivity of MALDI-MS enable diverse screening projects such as modifying enzymes and functional genomics surveys of gene activation/inhibition libraries.

Choe, Kisurb↗

The improvement of star positions by photographic methods

A brief description is given of the new astrometric camera and of the program on which it is being employed. This is the photography of the southern sky so that each star appears on at least four overlapping plates. Sets of star coordinates measured on each plate are combined with a limited set of provisional meridian places to give an accurate set of relative star positions which are independent of the meridian system together with a set of residuals for each plate-star. The technique is based on a simple geometrical model of image formation on photographic plates. Current investigations are concerned with the elimination of sources of systematic deviation from this model.

Clube, S. V. M.↗

Statistical performance of the intensified charged coupled device

The first analysis of the statistical performance of the intensified charge coupled device (CCD) is presented. The Poisson statistics of the arriving photons, the exponential pulse height distribution of the microchannel plate in the image intensifier, and the effects of discrete digitization of the charge in reading the CCD are included. A range of intensifier gains from the high levels that permit pulse counting to the low levels that can be used with the accumulation of charge on the CCD is considered. As a tool for this analysis, an analytical model of the performance of the detector system that is generally useful for predicting many aspects of system performance under a wide range of conditions is developed. The statistical penalty for operating the intensified CCD in the charge accumulation mode is not severe, and in some applications it may be desirable to accept this penalty to gain the advantages of increased dynamic range through charge accumulation. This investigation has revealed no pathological aspects of the operation of the detector system.

Sandel, B. R.↗

Space Shuttle Main Engine plume spectral monitoring preliminary results

In order to provide the information necessary to develop a rocket engine ground test failure detection monitor which keys on anomalous activity in the plume, a series of experimental observations were made during single engine Space Shuttle Main Engine (SSME) tests. The observations were conducted from the 220 nm wavelength in the ultraviolet out to the 15 micron wavelength in the infrared. Four types of instruments were employed including analog autoranging narrow band radiometers, optical multichannel analyzers, mechanical scanning and film plate spectrometers, and imaging cameras. Some results included: strong OH radiation in the UV up to vibrational transition state four; Na and K radiation lines in all phases of engine operation; reaction of some of the instruments to minor engine anomalies; good shock structure imaging; striations in the flow in the 310 nm OH band; and detection of gross changes in engine operating state such as start or shutdown.

Cikanek, H. A., III↗

Optical design of the Ultraviolet Imaging Spectrograph for the Cassini mission to Saturn

When the Cassini spacecraft arrives at Saturn early in the next century it will carry an Ultraviolet Imaging Spectrograph (UVIS). Observations made with the UVIS will support a broad set of scientific investigations including spectroscopy, imaging, and occultations. The UVIS consists of three spectroscopic channels covering the wavelength ranges 55-115 nm, 115-190 nm, and 160-320 nm. Each channel has an off-axis parabolic telescope followed by a toroidal grating spectrograph and an imaging microchannel plate-CODACON detector. The UVIS configuration was selected as a balanced solution to a large number of engineering and scientific constraints. We describe these constraints, the optical design, and the anticipated performance of the instrument.

Mcclintock, William E.↗

Absolute proper motions of distant Galactic satellites

We describe the motivation for a new program to determine the absolute proper motions (transverse velocities) for distant Galactic globular clusters and satellite dwarf spheroidal galaxies. The topic of globular-cluster proper motions is reviewed with emphasis on the correction from relative to absolute proper motions. Our project relies on astrometry from deep 2-5 m prime focus plates which contain images of numerous faint galaxies which are used to set a precise extragalactic reference frame. We discuss first results from the survey, determinations of the space motions for the clusters Palomar 5 and Palomar 3, at distances of 21 and 88 kpc, respectively.

Majewski, S. R.↗