Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Direct analysis of cotton swipes for plutonium isotope determination by microextraction-ICP-MS

This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe. Environmental sample (ES) swipes are routinely employed as a tool for monitoring activities in nuclear facilities. Traditional ES swipe analysis, as employed in nuclear safeguards, utilizes laborious ashing, digestion, and chemical separation procedures prior to mass spectrometric (MS) analysis. Here, an innovative sample introduction technique employing a microextraction probe to extract Pu directly from the swipe surface is described. The microextraction probe lowers onto the swipe surface, seals on a small area (8 mm 2 ), and delivers solvent (2% HNO 3 ) to extract actinide material that may be present. The extracted analyte is subsequently directed into a sector field inductively coupled plasma (ICP)-MS for isotope ratio determination. This microextraction-ICP-MS method successfully determined the isotopic composition ( 240 Pu/ 239 Pu and 242 Pu/ 239 Pu) of three Pu certified reference materials (CRM 136, 137, and 138) that were deposited (1 pg) onto ES swipes. The percent relative difference from the certified value, uncorrected for instrumental fractionation, was <2% for the 240 Pu/ 239 Pu ratio on all three CRMs and <10% for the 242 Pu/ 239 Pu ratio on CRM 136 and 138. Here, the percent relative standard deviation, an estimate of the sample-to-sample isotopic precision, was <4% for the 240 Pu/ 239 Pu and <15% for the 242 Pu/ 239 Pu. Method limits of detection were determined, based on measurements of an enriched 244 Pu material, to be ~7 fg. Additionally, a mixed uranium (U) and Pu deposition was made to determine the method's ability to simultaneously extract U and Pu and determine the isotopic composition of both analytes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Natural isotopic compositions of titanium, iron, and nickel observed in commercial fuel pellets – Promising candidate elements for stable isotope tagging

Stable isotope taggants would constitute unique identifiers for nuclear fuel cycle materials, resulting in expedited timelines and high confidence provenance assessments for nuclear forensics investigations. However, reliably identifying and interpreting stable isotope taggants in nuclear materials recovered from outside of regulatory control will largely be predicated on the assumption that the taggant element intrinsic to the untagged nuclear material exhibits natural isotopic ratios. Here, we present high-precision Ti, Fe, and Ni isotope compositions in 13 commercial low-enriched uranium (LEU) fuel pellets to assess the suitability of these transition metals as stable isotope taggants. Our investigations reveal limited isotope variations among the fuel pellets in all three elements, which are consistent with small mass-dependent isotope fractionations, comparable to variations previously reported for natural samples. In practice, isotopically tagged nuclear materials are expected to fall along isotopic mixing lines, since intrinsic background levels of taggant elements dilute the taggant towards natural isotope compositions. Furthermore, the observation that Ti, Fe, and Ni isotope compositions in a suite of LEU fuel pellets are close to or indistinguishable from estimates for the Bulk Silicate Earth demonstrates that a two end-member mixing assumption would be valid for these transition metals, indicating that all three are promising candidate elements for stable isotope tagging. Finally, we present mass balance calculations to quantify isotopic perturbations expected from admixing isotopically anomalous Ti, Fe, and Ni taggants to assess the interplay between elemental and taggant concentrations and find favorable compromises for facilitating successful taggant identification with current analytical methods.

Intentional forensics↗

Establishing the accuracy of position–specific carbon isotope analysis of propane by GC–pyrolysis–GC–IRMS

Rationale: Position-specific (PS) δ 13 C values of propane have proven their ability to provide valuable information on the evolution history of natural gases. Two major approaches to measure PS δ 13 C values of propane are isotopic 13 C nuclear magnetic resonance (NMR) and gas chromatography-pyrolysis-gas chromatography-isotope ratio mass spectrometry (GC-Py-GC-IRMS). Measurement accuracy of the isotopic 13 C NMR has been verified, but the requirements of large sample size and long experimental time limit its applications. GC-Py-GC-IRMS is a more versatile method with a small sample size, but its accuracy has not been demonstrated. Methods: We measured the PS δ 13 C values of propane from nine natural gases using both 13 C NMR and GC-Py-GC-IRMS, then evaluated the accuracy of the GC-Py-GC-IRMS method. Results: The results show that large carbon isotope fractionations occurred for both terminal and central carbons within propane during pyrolysis. The isotope fractionations during the pyrolysis are reproducible at optimum conditions, but vary between the two GC-Py-GC-IRMS systems tested, affected by experimental conditions (e.g., pyrolysis temperature, flow rate, and reactor conditions). Conclusions: It is necessary to evaluate and calibrate each GC-Py-GC-IRMS system using propane gases with accurately determined PS δ 13 C values. Finally, this study also highlights a need for PS isotope standards for propane and other molecules (e.g., butane and acetic acid).

03 NATURAL GAS↗

Sr-Nd-Pb isotope systematics of Australasian tektites: Implications for the nature and composition of target materials and possible volatile loss of Pb

The Australasian tektite (AAT) strewn field is the largest strewn field on the Earth with about ~10–30% coverage, both land and ocean, but a clearly identified source impact crater is absent despite the young age of AAT of ca. 790 ka. A genetic link between the Australasian tektites and their unequivocal parental materials is therefore largely impossible to establish. Nevertheless, the nature of the parental materials and the extent of volatilization can be constrained using the splash form tektites, carrying the chemical signatures of high-temperature processes, and the layered (so-called Muong Nong-type) tektites, which are less chemically homogenized and exceptionally abundant in the AAT field. New high-precision Sr, Nd and Pb isotopic measurements were obtained for a chemically and petrographically well-characterized suite of AAT, which included the Muong Nong-type (MN-AAT) with precisely known field locations in Laos and splash forms (SF-AAT) from different parts of the strewn field. Additionally, optically dark and light zones of the MN-AAT were also separately analyzed. Homogeneous ε Nd values from -11.8 to -11.2, combined with a narrow range of two-stage Nd model ages from 1.67 to 1.72 Ga for the entire AAT suite, point to a well-mixed source, in terms of REE, of the crustal segment from which the sedimentary material for tektites was ultimately derived. The Sr isotopic data largely overlap for SF-AAT and MN-AAT ( 87 Sr/ 86 Sr = 0.71636–0.72021) and indicate Paleozoic to Mesozoic sedimentary parentage. However, late Neogene to early Quaternary re-deposition and formation of a thick silt-sized sedimentary section with vertical stratification is required to comply with 10Be data. Lead isotope systematics documents at least three different components which can perhaps be represented by different mineral phases, such as feldspar, zircon, organic matter adsorbed on young sediments etc., sorted during fluvial transport and final deposition. In addition, the SF-AAT have systematically lower Pb contents than the MN-AAT, and generally show isotopically heavier Pb isotopic ratios. This is theoretically consistent with a preferential volatilization of lighter Pb isotopes during evaporation and considerably larger Pb loss from SF-AAT when compared to MN-AAT. Nevertheless, further experimental work would be necessary to unambiguously distinguish kinetic fractionation from source mixing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Remote isotope detection and quantification using femtosecond filament-laser ablation molecular isotopic spectrometry

We demonstrate the detection and quantification of isotopes from solid samples remotely at a distance of 36 m. This was accomplished through the combination of femtosecond filaments and laser ablation molecular isotopic spectrometry (F 2 -LAMIS). Isotopically enriched graphite samples with varying 13 C concentration were used and the F 2 -LAMIS emission was measured remotely using a portable spectrometer system. A standardless quantification approach was used to determine the corresponding isotopic ratios. The use of F 2 -LAMIS for the detection and quantification of isotopes at atmospheric pressure without the use of calibration standards opens the possibility to implement this technology for remote sensing of isotopes in field applications

07 ISOTOPE AND RADIATION SOURCES↗

The incorporation of environmentally derived 87 Sr / 86 Sr and Sr/Ca in early otolith formation of Chinook salmon

Abstract Effective species management often requires understanding patterns of movement and habitat use. A common approach in identifying where individuals reside relies upon chemical tracers from the environment that are incorporated into an individual's tissues. For fish, isotopes in their otoliths, specifically the portion of their otolith formed during their larval stage, have been used to identify the natal origin. Complicating this work, however, is the fact that during this life stage, there is a shift in the source of isotopes deposited onto the growing otolith from maternally to environmentally derived. The objective of this study was to identify the portion of the otolith representing this transition to environmentally derived isotopes so as to accurately investigate questions of natal origin for a threatened population of fall Chinook salmon ( Oncorhynchus tshawytscha ). We exposed developing larvae to four treatments that differed in terms of their water strontium isotope ratio ( 87 Sr/ 86 Sr) and used change‐point analysis of otolith 87 Sr/ 86 Sr and strontium to calcium ratio (Sr/Ca) to identify the otolith radius corresponding to the transition to environmentally derived isotopes. Our results indicated this transition occurred, on average, at 132 μm ( 87 Sr/ 86 Sr; ±50 μm standard deviation) and 127 μm (Sr/Ca; ±29 μm) from the otolith core, which corresponded to the developmental time between hatching and exogenous feeding. A substantial proportion of our otoliths (i.e., 61%) did not show convergence between otolith and water 87 Sr/ 86 Sr by the end of the 113‐day experiment, which was likely due to the dietary contribution of marine‐based feed. Therefore, we were unable to recommend an otolith radius to target for the purposes of reconstructing natal origin apart from being beyond approximately 130 μm.

Chittaro, Paul↗

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗

Round Robin Analysis of Uranium Isotopics on Cotton Swipes Measured Using Microextraction-Based Sampling Versus Conventional Bulk Analysis

A comparison of microextraction sampling methods to directly analyze uranium isotopics on cotton swipes was performed concurrently with traditional bulk-processing methods. For the microextraction sampling approach, two different detection platforms were evaluated, a quadrupole-based inductively coupled plasma mass spectrometer (ICP-MS) and the liquid sampling-atmospheric pressure glow discharge (LS-APGD) coupled to an Orbitrap mass spectrometer. Results presented from this innovative sampling approach (i.e., microextraction) are compared with a more traditional approach employed for analysis of cotton-based environmental swipes, namely bulk ashing/digestion, separation, and subsequent analysis by high-precision multi-collector ICP-MS. Overall, the microextraction approach proved to be a reliable and accurate means to determine isotopic ratios of uranium collected on cotton swipes. The ICP-MS-based detection had relative standard deviations of <0.65% for the major isotopic determinations, whereas the LS-APGD-Orbitrap method had relative standard deviations of <3%. The percent relative difference for the 235 U/ 238 U ratios, in comparison to the expected values, was <1% for ICP-MS and <4% for the microplasma-Orbitrap method. Additionally, the microextraction ICP-MS accurately (<2%) and precisely (<5%) determined the minor isotopic compositions (i.e., 234 U/ 238 U and 236 U/ 238 U).

ICP-MS↗

Using an Isotope Enabled Mass Balance to Evaluate Existing Land Surface Models

Abstract Land surface models (LSMs) play a crucial role in elucidating water and carbon cycles by simulating processes such as plant transpiration and evaporation from bare soil, yet calibration often relies on comparing LSM outputs of landscape total evapotranspiration ( ET ) and discharge with measured bulk fluxes. Discrepancies in partitioning into component fluxes predicted by various LSMs have been noted, prompting the need for improved evaluation methods. Stable water isotopes serve as effective tracers of component hydrologic fluxes, but data and model integration challenges have hindered their widespread application. Leveraging National Ecological Observation Network measurements of water isotope ratios at 16 US sites over 3 years combined with LSM‐modeled fluxes, we employed an isotope‐enabled mass balance framework to simulate ET isotope values ( δET ) within three operational LSMs (Mosaic, Noah, and VIC) to evaluate their partitioning. Models simulating δET values consistent with observations were deemed more reflective of water cycling in these ecosystems. Mosaic exhibited the best overall performance (Kling‐Gupta Efficiency of 0.28). For both Mosaic and Noah there were robust correlations between bare soil evaporation fraction and error (negative) as well as transpiration fraction and error (positive). We found the point at which errors are smallest ( x ‐intercept of the multi‐site regression) is at a higher transpiration fraction than is currently specified in the models. Which means that transpiration fraction is underestimated on average. Stable isotope tracers offer an additional tool for model evaluation and identifying areas for improvement, potentially enhancing LSM simulations and our understanding of land‐surface hydrologic processes.

58 GEOSCIENCES↗

Impact of T - and ρ -dependent decay rates and new (n, γ ) cross-sections on the s process in low-mass asymptotic giant branch stars

Aims. We study the impact of nuclear input related to weak-decay rates and neutron-capture reactions on predictions for the slow neutron-capture process (s process) in asymptotic giant branch (AGB) stars. We provide the first database of surface abundances and stellar yields of the isotopes heavier than iron from the Monash models. Methods. We ran nucleosynthesis calculations with the Monash post-processing code for seven stellar structure evolution models of low-mass AGB stars with three different sets of nuclear inputs. The reference set has constant decay rates and represents the set used in the previous Monash publications. The second set contains the temperature and density dependence of β decays and electron captures based on the default rates of nuclear NETwork GENerator (NETGEN). In the third set, we further update 92 neutron-capture rates based on re-evaluated experimental cross sections from the ASTrophysical Rate and rAw data Library. We compare and discuss the predictions of the sets relative to each other in terms of isotopic surface abundances and total stellar yields. We also compare the results to isotopic ratios measured in presolar stardust silicon carbide (SiC) grains from AGB stars. Results. The new sets of models result in a ∼66% solar s-process contribution to the p-nucleus 152 Gd, confirming that this isotope is predominantly made by the s process. The nuclear input updates result in predictions for the 80 Kr/ 82 Kr ratio in the He intershell and surface 64 Ni/ 58 Ni, 94 Mo/ 96 Mo, and 137 Ba/ 136 Ba ratios that are more consistent with the corresponding ratios measured in stardust; however, the new predicted 138 Ba/ 136 Ba ratios are higher than the typical values of the SiC grains. The W isotopic anomalies are in agreement with data from the analyses of other meteoritic inclusions. We confirm that the production of 176 Lu and 205 Pb is affected by too large uncertainties in their decay rates from NETGEN.

79 ASTRONOMY AND ASTROPHYSICS↗

Isotopic discrimination of natural and anthropogenic perchlorate sources in groundwater in a semi-arid region of northeastern Oregon (USA)

Perchlorate (ClO 4 - ) has synthetic and natural sources. Synthetic ClO 4 - is released to the environment from its use as an oxidant in military and aerospace applications, and from its presence in a variety of common commercial products, such as safety flares, chlorate herbicides, and fireworks. Natural sources of ClO 4 - in the environment include imported nitrate fertilizers derived from salt deposits in the Atacama Desert of Chile and indigenous natural ClO 4 - that accumulates in unsaturated soils and groundwaters in other arid and semi-arid environments, largely from atmospheric deposition. The stable isotope ratios of chlorine ( 37 Cl/ 35 Cl) and oxygen ( 18 O/ 16 O, 17 O/ 16 O) and the isotopic abundance of radioactive 36 Cl in ClO 4 - can be used to discriminate these different sources. Perchlorate was previously detected at relatively high concentrations (3.8–34.7 μg/L) in groundwater from many wells in the Boardman-Umatilla area near the Columbia River in northeastern Oregon, which is a semi-arid, highly agricultural, heavily irrigated area that includes several past and current military installations. Eight representative groundwater wells were sampled throughout this region and isotopic characteristics of ClO 4 - collected from each well were measured along with other chemical and isotopic parameters including tritium and other groundwater age indicators. We report isotopic data indicate that indigenous natural ClO 4 - was present in groundwater from all sampled wells and was the predominant source in five of the wells. Synthetic ClO 4 - was present in the three remaining wells with natural ClO 4 - , and a minor fraction of Atacama-fertilizer-derived ClO4- was indicated in one of the wells. Data from this study expand the geographic area of the USA in which indigenous natural ClO 4 - has been detected to include the semi-arid northwest. This study also illustrates the role of irrigation recharge as a mechanism for producing relatively high concentrations of indigenous natural ClO 4 - in groundwater by flushing accumulated salts from the unsaturated zone.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental investigation of elemental and isotopic evaporation processes by laser heating in an aerodynamic levitation furnace

In this report we carried out evaporation experiments on a B-type calcium–aluminium-rich inclusion (CAI) melt in a gas-mixing aerodynamic levitation laser furnace, at 1873 K and an oxygen partial pressure of 10 -9.1 atm, for durations ranging from 60 to 600 s. Evaporation of SiO 2 and MgO follow the same trend as those observed in vacuum furnace experiments at the same temperature and starting composition, showing that their evaporation relative to one another from the melt is independent of pressure, oxygen fugacity, and hydrodynamical regime specific to the furnace. Isotopic ratios of Mg and Si in evaporation residues are used to derive fractionation factors of α 26/24 Mg vap-liq = 0.9906± 0.0004 and α 30/28 Si vap-lip = 0.9943±0.0003, which are both significantly closer to unity than those found for evaporation in a vacuum, which translates to less isotope fractionation. The residues are also less isotopically fractionated than expected for cases in which transport of the gas species away from the melt is diffusion-controlled at 1-atm. By analysing the flow regimes in our furnace, we find that advection by the levitating gas is the primary mode of mass transport away from the melt surface, as opposed to diffusion-limited transport in a vacuum or 1-atm tube furnace. A modified Hertz–Knudsen–Langmuir formulation accounts for this process, and shows that isotopic fractionation of both Si and Mg reflect a saturation factor (ratio of the pressure of the evaporating species to vapour saturation pressure) equal to 0.75. This is in perfect accord with recent measurements of Cu isotopic fractionation using a similar furnace. The fact that three elements (Mg, Si, Cu) with varying equilibrium vapour pressures, activity coefficients in the liquid, and diffusion coefficients in the gas have the same scaling behaviour to saturation pressure is a strong indication that the mechanism controlling evaporation is driven by the hydrodynamical regime imposed in the furnace. Therefore, this class of experiments can be used to constrain processes in which advection dominates over diffusion, such as (but not limited to) planetary ejecta, tektites, giant impacts, nebular condensation in a turbulent flow, or nuclear fallout material. Finally, the possibility to reach high temperatures (in excess of 3500 K) in this furnace allows it to be used to evaluate the activity coefficients of melt components in extreme conditions relevant to molten planetary interiors (i.e., magma oceans), with a specific focus on refractory elements.

58 GEOSCIENCES↗

Neutron Irradiation Induced Changes in Isotopic Abundance of 6Li and 3D Nanoscale Distribution of Tritium in LiAlO2 Pellets Analyzed by Atom Probe Tomography

Tritium, a radioactive isotope of hydrogen is produced by neutron irradiation of 6Li enriched LiAlO2 pellets in Tritium producing burnable absorber rods (TPBARs). Three-dimensional nanoscale mapping of Tritium in irradiated pellets is critical to understand its spatial variation and its association with various microstructural features in the pellets. Spatially resolved analysis of 6Li isotopic enrichment in such ceramic pellets before and after irradiation can provide insights to heterogeneities in Li isotopic distribution. However, Li being a light isotope, its spatially resolved compositional or isotopic analysis is a challenging task to most analytical methods. Here we used atom probe tomography, to evaluate the Li isotopic enrichment in both the LiAlO¬2 matrix and the Li deficient secondary phase LiAl5O8 before irradiation. These results were then compared with 6Li isotopic ratio measured by APT analysis of neutron irradiated pellets to clearly demonstrate the unique capability of APT to quantitatively analyze the isotopic enrichment of 6Li as well as for other light elements present in these materials. Evidence for heterogenous nanoscale distribution of 3H and O3H within irradiated pellet microstructure is also provided, which is attributed to 3H trapping in irradiation induced vacancy clusters or voids within the LiAlO2 matrix. The characterization results given here, now prove the feasibility for using APT for analyzing nanoscale spatially resolved isotopic enrichment of Li as well as other light elements such as Tritium in TPBARs. This work also paves way to adopt APT for analyzing light elements such as Li and tritium in materials used for nuclear fusion reactor applications, geochemistry, astrophysics as well as for energy storage applications.

Devaraj, Arun↗

An R Shiny graphical user interface for analyzing, visualizing, and interpreting high precision mass spectrometric data

There is currently a lack of software that meets the needs for the analysis of raw data produced by modern isotope ratio mass spectrometers for both R&D and routine use at SRNL and other US national labs • Needs to accommodate multiple isotope systems, instruments, and manufacturers • Include modern statistical methods and handling/visualization of uncertainty • Flexible software with transparent (no “black box”) and reproducible methods • This project is inspired by existing discipline-specific data analysis software (e.g., Tripoli1 , ET_Redux2 , IsoplotR3) used in the geochemical community • Our goal is to build an open source data analysis software package that focuses on flexibility, transparency, and reproducibility

Labone, Elizabeth↗

An R shiny graphical user interface for highprecision mass spectrometric data analysis

• There is currently a lack of software that meets the needs for the analysis of raw data produced by modern isotope ratio mass spectrometers for both R&D and routine use at SRNL and other US national labs • Needs to accommodate multiple isotope systems, instruments, and manufacturers • Include modern statistical methods and handling/visualization of uncertainty • Flexible software with transparent (no “black box”) and reproducible methods • This project is inspired by existing discipline-specific data analysis software (e.g., Tripoli1 , ET_Redux2, IsoplotR3) used in the geochemical community • Our goal is to build an open source data analysis software package that focuses on flexibility, transparency, and reproducibility

LABONE, ELIZABETH↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

What can we learn from N 2 O isotope data? – Analytics, processes and modelling

The isotopic composition of nitrous oxide (N 2 O) provides useful information for evaluating N 2 O sources and budgets. Due to the co–occurrence of multiple N 2 O transformation pathways, it is, however, challenging to use isotopic information to quantify the contribution of distinct processes across variable spatiotemporal scales. Here, we present an overview of recent progress in N 2 O isotopic studies and provide suggestions for future research, mainly focusing on: analytical techniques; production and consumption processes; and interpretation and modelling approaches. Comparing isotope–ratio mass spectrometry (IRMS) with laser absorption spectroscopy (LAS), we conclude that IRMS is a precise technique for laboratory analysis of N 2 O isotopes, while LAS is more suitable for in situ/inline studies and offers advantages for site–specific analyses. When reviewing the link between the N 2 O isotopic composition and underlying mechanisms/processes, we find that, at the molecular scale, the specific enzymes and mechanisms involved determine isotopic fractionation effects. In contrast, at plot–to–global scales, mixing of N 2 O derived from different processes and their isotopic variability must be considered. We also find that dual isotope plots are effective for semi–quantitative attribution of co–occurring N 2 O production and reduction processes. More recently, process–based N 2 O isotopic models have been developed for natural abundance and 15 N–tracing studies, and have been shown to be effective, particularly for data with adequate temporal resolution. Here, despite the significant progress made over the last decade, there is still great need and potential for future work, including development of analytical techniques, reference materials and inter–laboratory comparisons, further exploration of N 2 O formation and destruction mechanisms, more observations across scales, and design and validation of interpretation and modelling approaches. Synthesizing all these efforts, we are confident that the N 2 O isotope community will continue to advance our understanding of N 2 O transformation processes in all spheres of the Earth, and in turn to gain improved constraints on regional and global budgets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chromium isotope fractionation during reduction of Chromium(VI) by Iron(II/III)-bearing clay minerals

Chromium stable isotope ratios are used to trace the reduction of Cr(VI) to Cr(III) in both ancient and modern systems. However, quantitative interpretation of Cr isotopic signatures has been stymied by the large variability in isotopic fractionation factors for Cr(VI) reduction by different reductants. Here we determine Cr isotope fractionation factors during Cr(VI) reduction by Fe(II/III)-bearing clay minerals, which are abundant in subsurface environments. Several variables were tested: pH, total Fe content of the clay, and the fraction of reduced Fe within the clay (Fe(II)/Fe(total)). The latter controls the standard reduction potential of the clay. Our results demonstrate that neither pH nor total Fe content of the clay have major effects on isotopic fractionation. In contrast, as the effective standard reduction potential of the clay and thus the standard free energy of Cr(VI) reduction become more negative, Cr isotope fractionation factors decrease in magnitude from - 4.9 to -1.3‰ according to a linear free energy relationship. This linear free energy relationship can be predicted from Marcus electron transfer theory and allows first-order predictions of Cr isotope fractionation factors to be made from the standard reduction potential or Fe(II)/Fe(total) of a clay, potentially improving our ability to model Cr isotope signatures in geochemical systems. Chromium is the first isotope system to show such a linear free energy relationship over a diverse range of reductants, including both aqueous and solid-phase reductants, and may provide a model for determining other redox-driven kinetic isotope effects in environmentally important isotope systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗