Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IP networks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

Power over Ethernet (PoE) technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras. They are systems that are familiar to and managed by on-site IT staff. As low voltage DC-power capabilities have increased with the advancement of IT network switches within offices, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. The connection of PoE devices to network switches offers the opportunity for energy monitoring and management to be performed through IT network management software. Data and results from technology validations of PoE equipment remain very limited. This lack of information hinders expansion of PoE as an energy management strategy as its benefits and challenges have been insufficiently quantified in real-world scenarios. This final report presents the findings of a DOE/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at six sites: two offices, three schools, and a hotel. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where not typically available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Systems Engineering Analysis of National Ignition Facility Industrial Controls Systems and Safety Interlock Systems Remote Input/Output Networking Migration from ControlNet to EtherNet/IP

The ControlNet industrial communications protocol and modules used in the Industrial Control System (ICS) and Safety Interlock System (SIS) at the National Ignition Facility (NIF) are no longer necessary and the ICS and SIS would be better served by migrating the communications structure to use EtherNet/Industrial Protocol (IP) and EtherNet bridge modules instead. By the admission of the vendor of ControlNet hardware, Rockwell Automation, in literature by Bill Petro [1], “Moving forward, customers will be able to optimize their asset utilization better using EtherNet/IP protocol than with ControlNet.” The NIF is one of the key elements of the Inertial Confinement Fusion (ICF) program at Lawrence Livermore National Laboratory (LLNL), a federally funded research and development center (FFRDC). The NIF contains the systems and provides the operational capacity to perform ICF, high energy density (HED), and discovery science experiments utilizing 192 individual beamlines, a host of diagnostics, and all the industrial systems required to facilitate these beamlines and diagnostics. The industrial systems are governed by the ICS and SIS, with the ICS providing control and the SIS providing monitoring and permissives. Construction on the NIF began in 1997 and was certified complete in 2009 and, as a result, the ICS and SIS were developed during this time using the tools that were available then. This includes the communications structure and protocols for these systems, much of which was, and still is, ControlNet. ControlNet, particularly during the time that the ICS and SIS were being built, has several attractive features. ControlNet hardware is exclusive to Rockwell Automation, which was the automation hardware chosen for the ICS and SIS. One feature that could be considered an advantage or a disadvantage depending on the communication needs of the system is that ControlNet also utilizes no active network components, excluding repeaters which are not always necessary. According to the architect of the ICS system at the NIF, Gordon Lau, one of the most attractive features of the ControlNet protocol during development of the ICS and SIS was that it is deterministic, providing timing of data transfer that is executed exactly as it is defined by the developer.

42 ENGINEERING↗

Global Interoperability of High Definition Video Streams Via ACTS and Intelsat

In 1993, a proposal at the Japan.-U.S. Cooperation in Space Program Workshop lead to a subsequent series of satellite communications experiments and demonstrations, under the title of Trans-Pacific High Data Rate Satellite Communications Experiments. The first of which is a joint collaboration between government and industry teams in the United States and Japan that successfully demonstrated distributed high definition video (HDV) post-production on a global scale using a combination of high data rate satellites and terrestrial fiber optic asynchronous transfer mode (ATM) networks. The HDV experiment is the first GIBN experiment to establish a dual-hop broadband satellite link for the transmission of digital HDV over ATM. This paper describes the team's effort in using the NASA Advanced Communications Technology Satellite (ACTS) at rates up to OC-3 (155 Mbps) between Los Angeles and Honolulu, and using Intelsat at rates up to DS-3 (45 Mbps) between Kapolei and Tokyo, with which HDV source material was transmitted between Sony Pictures High Definition Center (SPHDC) in Los Angeles and Sony Visual Communication Center (VCC) in Shinagawa, Tokyo. The global-scale connection also used terrestrial networks in Japan, the States of Hawaii and California. The 1.2 Gbps digital HDV stream was compressed down to 22.5 Mbps using a proprietary Mitsubishi MPEG-2 codec that was ATM AAL-5 compatible. The codec: employed four-way parallel processing. Improved versions of the codec are now commercially available. The successful post-production activity performed in Tokyo with a HDV clip transmitted from Los Angeles was predicated on the seamless interoperation of all the equipment between the sites, and was an exciting example in deploying a global-scale information infrastructure involving a combination of broadband satellites and terrestrial fiber optic networks. Correlation of atmospheric effects with cell loss, codec drop-out, and picture quality were made. Current efforts in the Trans-Pacific series plan to examine the use of Internet Protocol (IP)-related technologies over such an infrastructure. The use of IP allows the general public to be an integral part of the exciting activities, helps to examine issues in constructing the solar-system internet, and affords an opportunity to tap the research results from the (reliable) multicast and distributed systems communities. The current Trans- Pacific projects, including remote astronomy and digital library (visible human) are briefly described.

Hsu, Eddie↗

Hypergraph Analytics of Domain Name System Relationships

We report on the use of novel mathematical methods in hypergraph analytice over a large quantity of DNS data. Hypergraphs generalize graphs, as used in network science, to better model complex multiway relations in cyber data. Specifically, casting DNS data from Georgia Tech's ActiveDNS repository as hypergraphs allows us to fully represent the interactions between {\em collections} of domains and IP addresses. To facilitate large-scale analytics, we fielded an analytical pipeline of two capabilities. HyperNetX (HNX) is a Python package for the exploration and visualization of hypergraphs, acting as a frontend. For the backend, the Chapel HyperGraph Library (CHGL) is a library for high performance hypergraph analytics written in the exascale programming language Chapel. CHGL was used to process gigascale DNS data, performing compute-intensive calculations for data reduction and segmentation. Identified portions are then sent to HNX for both exploratory analysis and knowledge discovery targeting known tactics, techniques, and procedures.

Joslyn, Cliff A.↗

High-Performance, Reliable Multicasting: Foundations for Future Internet Groupware Applications

Network protocols that provide efficient, reliable, and totally-ordered message delivery to large numbers of users will be needed to support many future Internet applications. The Reliable Multicast Protocol (RMP) is implemented on top of IP multicast to facilitate reliable transfer of data for replicated databases and groupware applications that will emerge on the Internet over the next decade. This paper explores some of the basic questions and applications of reliable multicasting in the context of the development and analysis of RMP.

Callahan, John↗

Best Practices for Grid Communications

As the grid evolves, the communications architecture will need to evolve with it. That architecture affords a structured means by which the evolving complexities of the modern electric grid can be managed. This document provides best practices that can be implemented in the grid of today and evolve towards the grid and grid architecture of the future. The evolving grid and its control communications increasingly rely on commercial communications providers and a variety of technologies, from wireless (e.g., 5G, microwave, Wi-Fi) to wireline (fiber, copper) to radio communications (P25, other repeater-based systems), and all these communications systems rely on electric power. A reliable and resilient grid must account for this complex set of interdependencies in its planning activities, especially those involving restoration and recovery. The participation of all relevant parties in both planning and exercising of plans can prevent unexpected conditions that impede the reliable operation and recovery of the grid. Best practices for grid communications include using a Network Management System to document the operational state, define and monitor baselines, detect changes, and accelerate response to abnormalities. If transitioning from SONET to IP/packet-based systems, translating grid requirements into communications requirements for latency, bandwidth and throughput, IP packet delay variation, packet loss, and availability should inform and drive technology planning and selection as well as that communication system’s Quality of Service (QoS) policies and Service Level Agreements (SLAs). Secure and reliable timing is another key component of a reliable and resilient grid that can operate through adverse events. A trusted internal NTP configuration, an integrated and diverse timing delivery system, optimizing the timing architecture based on the transport technologies of the communications system, and using established standards can deliver the level of timing accuracy required by a range of time-sensitive power system applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Internet over the VDL-2 Subnetwork: the VDL-2/IP Aviation Datalink System

This report describes the design to operate the standard Internet communications protocols (IP) over the VHF aviation Data Link Mode 2 (VDL-2) subnetwork. The VDL-2/IP system specified in this report can operate transparently with the current aviation users of VDL-2 (Airline Communications and Reporting System, ACARS and Aeronautical Telecommunications Network, ATN) and proposed users (Flight Information Service via Broadcast, FIS-B). The VDL-2/IP system provides a straightforward mechanisms to utilize inexpensive, commercial off-the-shelf (COTS) communications packages developed for the Internet as part of the aviation datalink system.

Grappel, R. D.↗

Charging-management And Infrastructure-planning (cmip) Model

CMIP model explores various charging infrastructure network designs to serve a free-floating car-sharing fleet and determine the charging downtime experienced by the fleet for each design. Development of the CMIP model had two major steps: (1) describing modeling assumptions and (2) developing an integer program (IP) that jointly optimizes decisions about locations to install DC fast chargers and EV-to-charger assignments. The CMIP model integrates an EV charging model, EV energy consumption model, and heterogeneous, real-world vehicle use data with an integer programming optimization model to identify optimal location of new charging stations and calculate vehicle downtime for charging. The CMIP model can be applied to understand: (a) the reduction of EV fleet downtime if an additional fast-charging station is added to the current infrastructure and (b) to what extent total vehicle downtime would be sensitive to additional charging infrastructure.

Roni, MohammadS↗

MARIAH PCAP data for Validation Demonstration

This dataset holds simulated PCAP (packet capture) data from the SCEPTRE validation demonstration model as a set of pairwise communications between devices via specific protocols. All connections should be assumed to be symmetric, as this data is an aggregation of the true PCAP. A mapping is also provided associating each IP address with its true device type.

cyber-physical system↗

Interface Supports Multiple Broadcast Transceivers for Flight Applications

A wireless avionics interface provides a mechanism for managing multiple broadcast transceivers. This interface isolates the control logic required to support multiple transceivers so that the flight application does not have to manage wireless transceivers. All of the logic to select transceivers, detect transmitter and receiver faults, and take autonomous recovery action is contained in the interface, which is not restricted to using wireless transceivers. Wired, wireless, and mixed transceiver technologies are supported. This design s use of broadcast data technology provides inherent cross strapping of data links. This greatly simplifies the design of redundant flight subsystems. The interface fully exploits the broadcast data link to determine the health of other transceivers used to detect and isolate faults for fault recovery. The interface uses simplified control logic, which can be implemented as an intellectual-property (IP) core in a field-programmable gate array (FPGA). The interface arbitrates the reception of inbound data traffic appearing on multiple receivers. It arbitrates the transmission of outbound traffic. This system also monitors broadcast data traffic to determine the health of transmitters in the network, and then uses this health information to make autonomous decisions for routing traffic through transceivers. Multiple selection strategies are supported, like having an active transceiver with the secondary transceiver powered off except to send periodic health status reports. Transceivers can operate in round-robin for load-sharing and graceful degradation.

Block, Gary L.↗

The Surface Longwave Downward Fluxes of the NASA GEWEX SRB Release 4.0 IP Products: Validation Against the Surface-Based BSRN and PMEL Observed Data

Since the NASA Global Energy Water Exchanges (GEWEX) Surface Radiation Budget (SRB) project released its 3rd version of products in 2010, the GEWEX Data Assessments Panel (GDAP) has been working on integrating various data products to address issues in the closing of the global energy and water cycles. The 4th version of the SRB products, Rel. 4.0-IP, has integrated data products from the cloud, aerosol, atmosphere, ocean surface, and land surface projects, coordinating within GDAP, to produce a long-term time series of TOA and surface radiative estimates. The Rel. 4-IP shortwave products span 34 years continuously from July 1983 to June 2017 on a quasi-equal-area 1degree longitude by 1degree latitude grid system. The longwave products are for land only from 1983-07 to 1987-12; for both land and ocean from 1988-01 to 2009-12; and ocean only from 2010-01 to 2017-06. The data are provided at 3 hourly, 3-hourly-monthly, daily and monthly means. The ISCCP HXS clouds and radiances are the key cloud input of the current GEWEX SRB algorithms. In addition, the longwave algorithm has also made changes in cloud microphysical property, surface skin temperature input, surface emissivity, atmospheric profile, adding longwave aerosol optical properties, revising cloud overlap procedure, and so on. Details of changes in both inputs and algorithms are documented in a NASA Algorithm Theoretical Basis Document (ATBD). We have validated the surface longwave downward fluxes against the surface-based Baseline Surface Radiation Network (BSRN) and the Pacific Marine Environmental Laboratory (PMEL) buoy data. As of 2020, the BSRN archive has 12,116 site-months of observed records from 73 stations on all seven continents, and as of 2017, PMEL archive has 4389 buoy months of observed records from 64 buoys deployed in the tropics of Pacific, Atlantic and Indian Oceans. This paper presents how the SRB Rel. 4.0-IP surface longwave downward fluxes compare with these surface-based measurements and how the comparison statistics differ from that of Rel. 3.0.

GEWEX SRB↗

Toward an Integrated Product of Higher Accuracy and Longer Time Span: Improvement of the Upcoming NASA GEWEX SRB Data Release 4 over Release 3 Based on Validation Against Surface-Based Measurements

The NASA Global Energy and Water Exchanges (GEWEX) Surface Radiation Budget (SRB) is moving toward its next generation, the Release 4 Integrated Product (Rel. 4-IP), and its shortwave algorithm preliminary results as of this writing span 34 years continuously from July 1983 to June 2017 on a quasi-equal-area grid system with 44,016 gridboxes ranging from 1 longitude times 1 latitude around the Equator to 120 longitude times 1 latitude. The data are in the form of 3-hourly, 3-hourly-monthly, daily and monthly means. The Baseline Surface Radiation Network (BSRN) is a project of the Data and Assessments Panel from the GEWEX under the umbrella of the World Climate Research Programme (WCRP). Currently in the archive there are data from 67 sites located in all seven continents spanning from 1992 to the very present. The original BSRN records are at 1-, 2-, 3- or 5-minute intervals, and sophisticated quality-control procedures have been developed to eliminate erroneous records before hourly, daily and monthly means are computed. The Pacific Marine Environmental Laboratory (PMEL) arrays of buoys in the tropical oceans, TAO/TRITON (Pacific Ocean), RAMA (Indian Ocean) and PITARA (Atlantic Ocean), measure shortwave downward fluxes using pyranometers. These buoys transmit measured data to shore in real-time via the Argos satellite system. And these buoys are major components of the CLIVAR climate analysis project and the GOOS, GCOS, and GEOSS observing systems. So far there are data from 64 buoys and the earliest data start from 2000. We have extensively validated the Rel. 4-IP preliminary results against the BSRN and PMEL 3-hourly, daily and monthly means. In this paper, we will show that the new results not only temporally span 10 years longer than its predecessor, Release 3, but agree significantly better with the BSRN data over the land and PMEL data over the ocean.

Taiping Zhang↗

Internet Data Delivery for Future Space Missions

Ongoing work at National Aeronautics and Space Administration Goddard Space Flight Center (NASA/GSFC), seeks to apply standard Internet applications and protocols to meet the technology challenge of future satellite missions. Internet protocols and technologies are under study as a future means to provide seamless dynamic communication among heterogeneous instruments, spacecraft, ground stations, constellations of spacecraft, and science investigators. The primary objective is to design and demonstrate in the laboratory the automated end-to-end transport of files in a simulated dynamic space environment using off-the-shelf, low-cost, commodity-level standard applications and protocols. The demonstrated functions and capabilities will become increasingly significant in the years to come as both earth and space science missions fly more sensors and as the need increases for more network-oriented mission operations. Another element of increasing significance will be the increased cost effectiveness of designing, building, integrating, and operating instruments and spacecraft that will come to the fore as more missions take up the approach of using commodity-level standard communications technologies. This paper describes how an IP (Internet Protocol)-based communication architecture can support all existing operations concepts and how it will enable some new and complex communication and science concepts. The authors identify specific end-to-end data flows from the instruments to the control centers and scientists, and then describe how each data flow can be supported using standard Internet protocols and applications. The scenarios include normal data downlink and command uplink as well as recovery scenarios for both onboard and ground failures. The scenarios are based on an Earth orbiting spacecraft with downlink data rates from 300 Kbps to 4 Mbps. Included examples are based on designs currently being investigated for potential use by the Global Precipitation Measurement (GPM) mission.

Rash, James↗

Fault recovery in the reliable multicast protocol

The Reliable Multicast Protocol (RMP) provides a unique, group-based model for distributed programs that need to handle reconfiguration events at the application layer. This model, called membership views, provides an abstraction in which events such as site failures, network partitions, and normal join-leave events are viewed as group reformations. RMP provides access to this model through an application programming interface (API) that notifies an application when a group is reformed as the result of a some event. RMP provides applications with reliable delivery of messages using an underlying IP Multicast (12, 5) media to other group members in a distributed environment even in the case of reformations. A distributed application can use various Quality of Service (QoS) levels provided by RMP to tolerate group reformations. This paper explores the implementation details of the mechanisms in RMP that provide distributed applications with membership view information and fault recovery capabilities.

Callahan, John R.↗

Specification and Design of a Fault Recovery Model for the Reliable Multicast Protocol

The Reliable Multicast Protocol (RMP) provides a unique, group-based model for distributed programs that need to handle reconfiguration events at the application layer. This model, called membership views, provides an abstraction in which events such as site failures, network partitions, and normal join-leave events are viewed as group reformations. RMP provides access to this model through an application programming interface (API) that notifies an application when a group is reformed as the result of a some event. RMP provides applications with reliable delivery of messages using an underlying IP Multicast media to other group members in a distributed environment even in the case of reformations. A distributed application can use various Quality of Service (QoS) levels provided by RMP to tolerate group reformations. This paper explores the implementation details of the mechanisms in RMP that provide distributed applications with membership view information and fault recovery capabilities.

Montgomery, Todd↗

Network Configuration Analysis for Formation Flying Satellites

The performance of two networks to support autonomous multi-spacecraft formation flying systems is presented. Both systems are comprised of a ten-satellite formation, with one of the satellites designated as the central or 'mother ship.' All data is routed through the mother ship to the terrestrial network. The first system uses a TCP/EP over ATM protocol architecture within the formation, and the second system uses the IEEE 802.11 protocol architecture within the formation. The simulations consist of file transfers using either the File Transfer Protocol (FTP) or the Simple Automatic File Exchange (SAFE) Protocol. The results compare the IP queuing delay, IP queue size and IP processing delay at the mother ship as well as end-to-end delay for both systems. In all cases, using IEEE 802.11 within the formation yields less delay. Also, the throughput exhibited by SAFE is better than FTP.

Knoblock, Eric J.↗

Satellite systems requirements for land mobile communications

The system design objective is to provide a satellite link through a gateway station, connecting mobile users in areas not served by a terrestrial cellular system to the switched telephone network (STN). The proposed frequency allocation comprises a pair of 10-MHz bands in the 806-890 MHz range specified by the 1979 World Administrative Radio Conference (WARC) for land-mobile satellite service (LMSS). The satellite design is constrained by projected STS capability with an upper stage of the wide-body Centaur or Integral Propulsion System (IPS) type. For the latter (a TRW design), the payload is limited to approximately 10,400 lb. The design is to be based on 1990's technology, with initial operating capability scheduled for 1995. The satellite should be designed for a 7-year life. Mobile-unit compatibility with cellular system specifications is desirable, if consistent with other system requirements.

Horstein, M.↗

Adding HDLC Framing to CCSDS Recommendations

Current Space IP missions use High-Level Data Link Control (HDLC) framing to provide standard serial link interfaces over a space link. HDLC is the standard framing technique used by all routers over clock and data serial lines and is also the basic framing used in all Frame Relay services which are widely deployed in national and international communication networks. In late 2003 a presentation was made to CCSDS committees to initiate discussion on including HDLC in the CCSDS recommendations for space systems. This presentation will summarize the differences between variable length HDLC frames and fixed length CCSDS frames. It will also discuss where and how HDLC framing would fit into the overall CCSDS structures.

Hogie, Keith↗