Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Impact of Volumetric Modulated Arc Therapy Technique on Treatment With Partial Breast Irradiation

Purpose: To investigate the technical feasibility of volumetric modulated arc therapy (V-MAT) in the delivery of partial breast irradiation (PBI). Methods and Materials: V-MAT and the standard, three-dimensional conformal radiotherapy (3D-CRT), were compared retrospectively in 8 patients previously treated with PBI. These patients' plans were replanned with a single partial arc using V-MAT that included partial blocking to minimize normal tissue dose. Dosimetric parameters were calculated to evaluate plan quality. Quality assurance studies included verifying both the point and the multiple planar doses. Total monitor units and delivery time were also evaluated, and collision clearance was analyzed. Results: Volumes of ipsilateral lung irradiated to 10 Gy (V10) and 20 Gy (V20) by V-MAT were significantly less than those of 3D-CRT (p = 0.03 for V10 and p = 0.025 for V20). The volume of ipsilateral breast irradiated to 5 Gy was significantly less by using V-MAT than with 3D-CRT (p = 0.02), with a ratio of integrated dose of <1.00. The total mean monitor units (489 {+-} 38) for V-MAT were significantly less than those for 3D-CRT (634 {+-} 123) (p = 0.017), with a 23% reduction. The average machine delivery time was 1.21 {+-} 0.10 min for the V-MAT plans and 6.28 {+-} 1.40 min for the 3D-CRT plans, resulting in a reduction factor of 80.1%. The conformity indexes were 1.3 in the V-MAT plans and 1.5 in the 3D-CRT plans (p = 0.102). Conclusions: V-MAT technology is feasible for PBI patients. Compared to a conventional 3D-CRT technique, it is more efficient, offers equivalent or better dose conformity, delivers lower doses to the ipsilateral lung and breast, and may potentially reduce intrafractional motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of a Radiation Model of the Shuttle Space Suit

The extravehicular activity (EVA) required to assemble the International Space Station (ISS) will take approximately 1500 hours with 400 hours of EVA per year in operations and maintenance. With the Space Station at an inclination of 51.6 deg the radiation environment is highly variable with solar activity being of great concern. Thus, it is important to study the dose gradients about the body during an EVA to help determine the cancer risk associated with the different environments the ISS will encounter. In this paper we are concerned only with the trapped radiation (electrons and protons). Two different scenarios are looked at: the first is the quiet geomagnetic periods in low Earth orbit (LEO) and the second is during a large solar particle event in the deep space environment. This study includes a description of how the space suit's computer aided design (CAD) model was developed along with a description of the human model. Also included is a brief description of the transport codes used to determine the total integrated dose at several locations within the body. Finally, the results of the transport codes when applied to the space suit and human model and a brief description of the results are presented.

Anderson, Brooke M.↗

SU-E-T-612: Photonuclear Activation of Prosthetic Hips in Radiotherapy

Purpose: To measure the neutron induced activation of a prosthetic hip when exposed to an 18 MV radiotherapy linac beam to assess the potential dose to patients. Methods: A prosthetic hip (Thackray, UK) was placed in a water phantom and irradiated (both in-field and out-of-field) with an 18 MV linac beam. Gamma spectroscopy was used to identify the radioisotopes produced. Following the in-field irradiation where the induced activity is higher, high sensitivity lithium fluoride Thermoluminescence Dosimeters (TLD-100H) (Harshaw, USA) were placed on the surface to measure the dose which would be deposited to nearby tissue resulting from the induced radioactivity. Results: The radioisotopes produced in the hip prosthesis have been identified as {sup 5{sup 2}}V, {sup 5{sup 3}}Fe, and {sup 56}Mn which have half-lives of 3.74, 8.51 and minutes respectively. The 378 and 511 keV characteristic peaks of {sup 5{sup 3}}Fe do not appear in the spectra collected from hips irradiated in the out-of-field region. This isotope is produced by photonuclear interactions within the hip itself. {sup 52}V and {sup 56}Mn appear in spectra collected from hips irradiated either within the photon beam or in the nearby out-of-field region, implying that they are produced by incident neutron radiation produced in components of the linear accelerator.The integrated dose which would be deposited in the tissue immediately surrounding the hip after four hours (1.5 half-lives of the longest lived product) was measured as approximately 100 µGy, following a 10,000 MU irradiation of the prosthesis. A highly accurate measurement of the dose is challenging because of the irregular shape of the prosthesis. Conclusion: The cumulative dose measured at the surface of the hip is 0.0001% of the in-field dose, and is therefore negligible compared with the doses the patient receives as a consequence of their treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation-Hardened Circuitry Using Mask-Programmable Analog Arrays: Report 3

As the recent accident at Fukushima Daiichi so vividly demonstrated, telerobotic technologies capable of withstanding high radiation environments need to be readily available to enable operations, repair, and recovery under severe accident scenarios when human entry is extremely dangerous or not possible. Telerobotic technologies that enable remote operation in high dose rate environments have undergone revolutionary improvement over the past few decades. However, much of this technology cannot be employed in nuclear power environments because of the radiation sensitivity of the electronics and the organic insulator materials currently in use. This is a report of the activities involving Task 3 of the Nuclear Energy Enabling Technologies (NEET) 2 project Radiation Hardened Circuitry Using Mask-Programmable Analog Arrays. Evaluation of the performance of the system for both pre- and post-irradiation as well as operation at elevated temperature will be performed. Detailed performance of the system will be documented to ensure the design meets requirements prior to any extended evaluation. A suite of tests will be developed which will allow evaluation before and after irradiation and during temperature. Selection of the radiation exposure facilities will be determined in the early phase of the project. Radiation exposure will consist of total integrated dose (TID) up to 200 kRad or above with several intermediate doses during test. Dose rates will be in various ranges determined by the facility that will be used with a target of 30 kRad/hr. Many samples of the pre-commercial devices to be used will have been tested in previous projects to doses of at least 300 kRad and temperatures up to 125C. The complete systems will therefore be tested for performance at intermediate doses. Extended temperature testing will be performed up to the limit of the commercial sensors. The test suite performed at each test point will consist of operational testing of the three basic measurement functions plus electronic functional testing (power dissipation, voltage offset changes, noise variations, etc.). This suite will be developed as part of this task.

42 ENGINEERING↗

SU-F-BRE-03: Consideration of a Track-Interaction Model for Radiochromic Film Response

Purpose: Conventional methods for characterizing the energy response of radiochromic film (RCF) typically involve assessing changes in response when exposed to various beam qualities and use Monte Carlo to determine absorbed dose. These methods represent RCF as a dose integrator of a homogeneous energy deposition volume. Apparent film saturation, nonlinearity, and intrinsic energy dependence are unpredicted with conventional methods. Recent work has shown significant RCF intrinsic energy dependence, which limits its use in absolute dosimetry. This work introduces a track-interaction model (TIM) for RCF and assesses its ability to predict total energy response. Methods: A TIM based on Katz single-hit theory was developed to accumulate energy flux along particle tracks within active crystals, represented as (1×1×20)um{sup 3} prisms about the Gafchromic™ EBT3 active volume using MCNP5 and Matlab. Energy flux contributed to film response only if near the threshold energy for polymerization in polydiacetylenes (2.5eV/monomer). Energy deposition in excess of maximum efficiency represented crystal saturation and did not contribute to film response. The TIM was applied to RCF exposed in air to various monoenergetic photon beams and Co-60. Geometric distribution of energy flux was found for each beam quality in a (1×1)mm{sup 2} RCF area. RCF response relative to Co-60 absorbed dose-to-water (S-TIM) was determined and compared to published values (S-PUB). Results: TIM successfully predicted that lower energy radiation is less effective at inducing polymerization, though the magnitude of the phenomenon was overpredicted. S-TIM was −29% and +20% for 20 and 40 keV, respectively. This agreed qualitatively with S-PUB of −27% and +16%. TIM-generated sensitometric curves contained the non-linearity and saturation apparent in RCF. Conclusion: This work indicates the possibility for TIMs to predict changes in RCF response to various energies. Future work will refine TIM by considering size distributions of active elements, other RCF formulations, and response in complex treatment fields. Acknowledgements: The authors wish to thank Dr. Christopher Soares at NIST (Gaithersburg, MD) for performing film measurements and Dr. David Lewis of Ashland, Inc. (Wayne, NJ) for making the EBT3 film available to us.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predictors of Trigeminal Neuropathy After Radiosurgery for Vestibular Schwannomas

Purpose: To analyze the relationship between dosimetric characteristics and symptoms related to trigeminal neuropathy (TN) observed after radiosurgery (RS) for vestibular schwannomas (VS); to propose guidelines to optimize planification in VS RS regarding TN preservation; and to detail the mechanism of TN impairment after VS RS. Methods and Materials: One hundred seventy-nine patients treated between 2011 and 2013 for VS RS and without trigeminal impairment before RS were included in a retrospective study. Univariate and multivariate analyses were performed to determine predictors of TN among characteristics of the patients, the dosimetry, and the VS. Results: There were 20 Koos grade 1, 99 grade 2, 57 grade 3, and 3 grade 4. Fourteen patients (7.8%) presented a transitory or permanent TN. Between the patients with and without TN after VS RS, there was no significant difference regarding dosimetry or VS volume itself. Significant differences (univariate analysis P<.05, Mann-Whitney test) were found for parameters related to the cisternal portion of the trigeminal nerve: total integrated dose, maximum dose, mean dose, volume of the Vth nerve (Vol{sub v}), and volume of the Vth nerve receiving at least 11 Gy (Vol{sub Vcist>11Gy}), but also for maximal dose to the Vth nerve nucleus and intra-axial portion (Dose max{sub Vax}). After multivariate analysis, the best model predicting TN included Vol{sub Vcist>11Gy} (P=.0045), Dose max{sub Vax} (P=.0006), and Vol{sub v} (P=.0058). The negative predictive value of this model was 97%. Conclusions: The parameters Vol{sub Vcist>11Gy}, Dose max{sub Vax}, and Vol{sub v} should be checked when designing dosimetry for VS RS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of ITER radiation environment during the remote-handling operation of In-Vessel components with D1SUNED

During ITER operational life, a remote-handled cask will be used to transfer In-Vessel components to the Hot Cell for maintenance, storage and decommissioning purposes. Due to the distribution of penetrations for system allocation in the facility, the radiation field of each transfer operation presents a high spatial variability; all operations must be studied independently for workers and electronics protection. In this paper, we present a fully representative approach to describe the radiation environment during the complete remote-handling scenario of In-Vessel components in the ITER facility. The impact of all relevant radiation sources during different stages of the operation is addressed. As-built structures and 2020 baseline designs are considered to produce the most detailed neutronics model of the Tokamak Complex, the 400,000-tonne civil structure hosting the tokamak, up to date. Novel capabilities of the D1SUNED code have allowed to compute the integral dose, the dose rate and the photon-induced neutron flux of both moving and static radiation sources. Time bins are included in the simulations to compute the dose rate caused by In-Vessel components at all positions along the transfer. The time evolution of the dose rate is built in video format with a 1-m resolution, especially valuable for hot-spots identification.

42 ENGINEERING↗

Simulations for CMS hadron endcap calorimeter upgrade at HL-LHC

The upgrade of the present endcap calorimeters is foreseen to prepare the CMS experiment for the High Luminosity LHC. Integrated doses at the location of the front layers of the hadron endcap calorimeter are expected to reach 20 Mrad. Studies of radiation fields are presented in this report. At the same time, the effects of pileup will become more severe, making the identification of jet objects more challenging. We estimated the effects of different transverse segmentations of back hadron calorimeter (BH) for CMS upgrade.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Annular Core Research Reactor (ACRR) Pulse Curve Characterization

Reactor pulse characterization at the Annular Core Research Reactor (ACRR) at Sandia Technical Area V (TA-V) is commonly done through photo conductive detection (PCD) and calorimeter detectors. Each of these offer a mode of analyzing a digital signal with different advantages/methods for determination of integrated dose or temporal based metrology. This report outlines a method and code that takes the millions of data points from such detectors and delivers a characteristic pulse trendline through two main methods: digital signal filtration and machine learning, in particular, Support Vector Machines (SVMs). Each method's endpoint is to deliver a characteristic curve for the many bucket environments of ACRR while considering other points of interest including delayed gamma removal for prompt dose metrics. This work draws and adds on previous work detailing the delayed gamma fraction contributions from CINDER simulations of the ACRR. Results from this project show a method to determine characteristic curves in a way that has previously been limited by data set size.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Heavy Ion Minibeam Therapy: Side Effects in Normal Brain

The purpose of this work was to investigate whether minibeam therapy with heavy ions might offer improvements of the therapeutic ratio for the treatment of human brain cancers. To assess neurotoxicity, we irradiated normal juvenile rats using 120 MeV lithium-7 ions at an absorbed integral dose of 20 Gy. Beams were configured either as a solid parallel circular beam or as an array of planar parallel minibeams having 300-micron width and 1-mm center-to-center spacing within a circular array. We followed animals for 6 months after treatment and utilized behavioral testing and immunohistochemical studies to investigate the resulting cognitive impairment and chronic pathologic changes. We found both solid-beam therapy and minibeam therapy to result in cognitive impairment compared with sham controls, with no apparent reduction in neurotoxicity using heavy ion minibeams instead of solid beams under the conditions of this study.

60 APPLIED LIFE SCIENCES↗

Radiation damage in MOS integrated circuits, Part 1

Complementary and p-channel MOS integrated circuits made by four commercial manufacturers were investigated for sensitivity to radiation environment. The circuits were irradiated with 1.5 MeV electrons. The results are given for electrons and for the Co-60 gamma radiation equivalent. The data are presented in terms of shifts in the threshold potentials and changes in transconductances and leakages. Gate biases of -10V, +10V and zero volts were applied to individual MOS units during irradiation. It was found that, in most of circuits of complementary MOS technologies, noticable changes due to radiation appear first as increased leakage in n-channel MOSFETs somewhat before a total integrated dose 10 to the 12th power electrons/sg cm is reached. The inability of p-channel MOSFETs to turn on sets in at about 10 to the 13th power electrons/sq cm. Of the circuits tested, an RCA A-series circuit was the most radiation resistant sample.

Danchenko, V.↗

Thermoluminescent dosimetry for the Apollo 16 microbial response to space environment experiment (M191)

Lithium fluoride thermoluminescent chips were used to provide an integrated dose from the broad spectrum of ionizing radiation to the Microbial Response to Space Environment Experiment (M191). The chips were positioned in the flight hardware to provide data on ionizing radiation within specific volume segments. A uniform radiation dose of 4.8 x 0.001 plus or minus 2 x 0.0001 joule/kg resulted.

Brown, R. D.↗

Trends and techniques for space base electronics

A system was developed for depositing aluminum and aluminum alloys by the D.C. sputtering technique. This system which was designed for a high level of cleanliness and ion monitoring the deposition parameters during film preparation is ready for studying the deposition and annealing parameters upon double level metal preparation. The finite element method was studied for use in the computer modeling of two dimensional MOS transistor structures. An algorithm was developed for implementing a computer study which is based upon the finite difference method. The program was modified and used to calculate redistribution data for boron and phosphorous which had been predeposited by ion implantation with range and straggle conditions typical of those used at MSFC. Data were generated for 111 oriented SOS films with redistribution in N2, dry O2 and steam ambients. Data are given showing both two dimensional effects and the evolution of the junction depth, sheet resistance and integrated dose with redistribution time.

Gassaway, J. D.↗

Charged particle LET-spectra measurements aboard LDEF

The linear energy transfer (LET) spectra of charged particles was measured in the 5 to 250 keV/micron (water) interval with CR-39 and in the 250 to 1000 keV/micron (water) interval with polycarbonate plastic nuclear track detectors (PNTDs) under different shielding depths in the P0006 experiment. The optimal processing conditions were determined for both PNTDs in relation to the relatively high track densities due to the long term exposure in space. The total track density was measured over the selected samples, and tracks in coincidence on the facing surfaces of two detector sheets were selected for measuring at the same position on each sheet. The Short Range (SR) and Galactic Cosmic Ray (GCR) components were measured separately. The integral dose and dose rate spectra of charged particles are also given. The high LET portion of the LET spectra was measured with high statistical accuracy. This is a unique result of this experiment due to the low flux of this type of particle under typical shielding conditions.

Csige, I.↗

Charged particle LET-spectra measurements aboard LDEF

The linear energy transfer (LET) spectra of charged particles was measured in the 5 to 250 keV/micron (water) interval with CR-39 and in the 500 to 1500 keV/micron (water) interval with polycarbonate plastic nuclear track detectors (PNTDs) under different shielding depths in the P0006 experiment. The optimal processing conditions were determined for both PNTDs in relation to the relatively high track densities due to the long term exposure in space. The total track density was measured over the selected samples, and tracks in coincidence on the facing surfaces of two detector sheets were selected for measuring at the same position on each sheet. The short range (SR) and Galactic Cosmic Ray (GCR) components were measured separately with CR-39 PNTDs and the integral dose and dose rate spectra of charged particles were also determined. The high LET portion of the LET spectra was measured with polycarbonate PNTDs with high statistical accuracy. This is a unique result of this exposure due to the low flux of these types of particles for typical spaceflight durations. The directional dependence of the charged particles at the position of the P0006 experiment was also studied by four small side stacks which surrounded the main stack and by analyzing the dip angle and polar angle distributions of the measured SR and GCR particle tracks in the main stack.

Csige, I.↗

Nuclear modules for space electric propulsion

Analysis of interplanetary cargo and piloted missions requires calculations of the performances and masses of subsystems to be integrated in a final design. In a preliminary and scoping stage the designer needs to evaluate options iteratively by using fast computer simulations. The Oak Ridge National Laboratory (ORNL) has been involved in the development of models and calculational procedures for the analysis (neutronic and thermal hydraulic) of power sources for nuclear electric propulsion. The nuclear modules will be integrated into the whole simulation of the nuclear electric propulsion system. The vehicles use either a Brayton direct-conversion cycle, using the heated helium from a NERVA-type reactor, or a potassium Rankine cycle, with the working fluid heated on the secondary side of a heat exchanger and lithium on the primary side coming from a fast reactor. Given a set of input conditions, the codes calculate composition. dimensions, volumes, and masses of the core, reflector, control system, pressure vessel, neutron and gamma shields, as well as the thermal hydraulic conditions of the coolant, clad and fuel. Input conditions are power, core life, pressure and temperature of the coolant at the inlet of the core, either the temperature of the coolant at the outlet of the core or the coolant mass flow and the fluences and integrated doses at the cargo area. Using state-of-the-art neutron cross sections and transport codes, a database was created for the neutronic performance of both reactor designs. The free parameters of the models are the moderator/fuel mass ratio for the NERVA reactor and the enrichment and the pitch of the lattice for the fast reactor. Reactivity and energy balance equations are simultaneously solved to find the reactor design. Thermalhydraulic conditions are calculated by solving the one-dimensional versions of the equations of conservation of mass, energy, and momentum with compressible flow.

Difilippo, F. C.↗

Twenty Years of Radiation Measurements in Low-Earth Orbit - What Have We Learned Space Radiation Environment?

The advent of the Space Shuttle program has made possible space radiation environment measurements spanning a wide range of altitudes and orbital inclinations over multiple solar cycles. These measurements range from routine integral dose measurements with thermoluminescent dosimeters to particle energy spectra measurements made with a charged particle telescope. This paper will review the new understanding about the space radiation environment gained from this diverse data set. Major findings from these measurements include: estimations of the westward drift rate of the South Atlantic Anomaly (SAA) of 0.28-0.49/y; evidence for a northward component to the SAA drift of 0.08-0.12/y; observation of the formation and decay of the pseudo-stable additional radiation belt following the Mar 1991 SPE and geomagnetic storm with an estimated decay e-folding time of 9-10 months; observation of a local geomagnetic east-west trapped proton exposure anisotropy with an estimated magnitude of 1.6-3.3; demonstration that the trapped proton exposure in low-Earth orbit (LEO) can be reasonably modeled as a power law function of atmospheric density in the SAA region, with best correlations obtained when the exospheric temperature saturates at 938-975 K; the actual solar cycle modulation of trapped proton exposure in LEO is less than predicted by the AP8 model; and the testing and validation of GCR flux models, radiation transport codes, and dynamic geomagnetic cutoff models. Long-term, time-resolved proportional counter measurements made aboard the Mir during the same period provides further demonstration of the solar cycle modulation of the trapped protons at low altitudes - the observed modulation is also well described as power law function of atmospheric density. These data and findings have helped to improve the overall accuracy of pre-mission crew exposure projections using various semi-empirical space environment models, radiation transport codes, and spacecraft radiation shielding models. During the rise phase of solar cycle 22 (1987-1991), the RMS error between preflight exposure projections and measured crew exposure was 73%. For the rise phase of cycle 23 (1997-2001), the preflight exposure projection RMS error has decreased to 23%. The launch and assembly of the Space Station has begun a new era of long-term LEO space environment monitoring. The radiation environment at the Space Station will be monitored with three external charged particle telescopes oriented in the velocity vector, anti-velocity vector, and zenith directions. Data from the telescopes will provide charge, mass, energy, and arrival direction for incident particles with energy to mass ratios of 13- 450 MeV/amu and Z of 1-24. The external environment data will be complimented by measurements from a portable charged particle telescope and proportional counter located inside the vehicle.

Golightly, Michael J.↗

Modeling Ionizing Radiation for Spaceflight Dynamic Radioisotope Power Systems

This paper presents methods, simulations, and analyses for spaceflight ionizing radiation exposures to three dynamic radioisotope power systems(DRPSs). The specific systems being investigated are part of an open solicitation by the National Aeronautics and Space Administration (NASA) and the US Department of Energy (DOE)to develop DRPS convertor technologies. The analyses include ionizing radiation sources from PuO2andgalactic cosmic rays (GCRs) over notional 20-year mission architectures with optional 10-year exposures from Jovian radiation environments. Total integrated doses to various components are calculated and compared to known material degradation thresholds in the open literature. Based on the findings, certain material trades are recommended for Jovian and non-Jovian mission architectures based solely on ionizing radiation. However, consideration is given to known and unknown synergistic degradation effects(i.e., radiation in combination with heat, pressure, or outgassing)that may be relevant to these systems and are not captured in these analyses.

Models↗