Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMAGE PLANES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Multispectral data acquisition and classification - Statistical models for system design

In this paper we relate the statistical processes that are involved in multispectral data acquisition and classification to a simple radiometric model of the earth surface and atmosphere. If generalized, these formulations could provide an analytical link between the steadily improving models of our environment and the performance characteristics of rapidly advancing device technology. This link is needed to bring system analysis tools to the task of optimizing remote sensing and (real-time) signal processing systems as a function of target and atmospheric properties, remote sensor spectral bands and system topology (e.g., image-plane processing), radiometric sensitivity and calibration accuracy, compensation for imaging conditions (e.g., atmospheric effects), and classification rates and errors.

Huck, F. O.↗

Digital Image Velocimetry

Digital image velocimetry is technique for extracting two-dimensional (in image planes) velocities of objects from multiple photographs or video images of objects. Devised to overcome disadvantages of particle-image velocimetry and laser-speckle velocimetry, both of which involve use of illuminated seed particles to make flows visible. Directions of velocity vectors determined unambiguously, and dynamic range limited only by speed of camera or, equivalently, by speed of stroboscopic illumination.

Cho, Y.-C.↗

Three-dimensional tracking of cardiac catheters using an inverse geometry x-ray fluoroscopy system

Purpose: Scanning beam digital x-ray (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis at multiple planes. This study describes a tomosynthesis-based method for 3D tracking of high-contrast objects and present the first experimental investigation of cardiac catheter tracking using a prototype SBDX system. Methods: The 3D tracking algorithm utilizes the stack of regularly spaced tomosynthetic planes that are generated by SBDX after each frame period (15 frames/s). Gradient-filtered versions of the image planes are generated, the filtered images are segmented into object regions, and then a 3D coordinate is calculated for each object region. Two phantom studies of tracking performance were conducted. In the first study, an ablation catheter in a chest phantom was imaged as it was pulled along a 3D trajectory defined by a catheter sheath (10, 25, and 50 mm/s pullback speeds). SBDX tip tracking coordinates were compared to the 3D trajectory of the sheath as determined from a CT scan of the phantom after the registration of the SBDX and CT coordinate systems. In the second study, frame-to-frame tracking precision was measured for six different catheter configurations as a function of image noise level (662-7625 photons/mm{sup 2} mean detected x-ray fluence at isocenter). Results: During catheter pullbacks, the 3D distance between the tracked catheter tip and the sheath centerline was 1.0{+-}0.8 mm (mean {+-}one standard deviation). The electrode to centerline distances were comparable to the diameter of the catheter tip (2.3 mm), the confining sheath (4 mm outside diameter), and the estimated SBDX-to-CT registration error ({+-}0.7 mm). The tip position was localized for all 332 image frames analyzed and 83% of tracked positions were inside the 3D sheath volume derived from CT. The pullback speeds derived from the catheter trajectories were within 5% of the programed pullback speeds. The tracking precision of ablation and diagnostic catheter tips ranged from {+-}0.2 mm at the highest image fluence to {+-}0.9 mm at the lowest fluence. Tracking precision depended on image fluence, the size of the tracked catheter electrode, and the contrast of the electrode. Conclusions: High speed multiplanar tomosynthesis with an inverse geometry x-ray fluoroscopy system enables 3D tracking of multiple high-contrast objects at the rate of fluoroscopic imaging. The SBDX system is capable of tracking electrodes in standard cardiac catheters with approximately 1 mm accuracy and precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Micro to nanostructural observations in neutron irradiated nuclear graphites PCEA and PCIB

Here, the neutron irradiation induced structural changes in nuclear grade graphites PCEA and PCIB were investigated using scanning electron microscopy (SEM), X-ray diffraction (XRD), Raman spectroscopy, transmission electron microscopy (TEM), selected area electron diffraction (SAED) and electron energy loss spectroscopy (EELS). The graphite samples were irradiated at the Advanced Test Reactor National User Facility at the Idaho National Laboratory. Received doses ranged from 1.5 dpa - 6.8 dpa and irradiation temperatures varied between 350°C - 670°C. XRD data showed crystallite sizes to reduce by 35% (for both La and Lc) for low dose, low temperature specimens and by 50% (for both La and Lc) for high dose, high temperature specimens (compared to unirradiated specimens of the same grade). Analysis of the G peak in Raman spectra of irradiated specimens provided evidence for the fragmentation of crystallites following neutron irradiation. Conventional TEM and SAED were used to observe the structure of lattice fringes and measure the spacing of planes. Image analysis software was applied to TEM images to quantify fringe length, tortuosity, and relative orientation of planes. Neutron irradiation appeared to induce basal plane fragmentation and curvature. EELS was performed to study the proportion of sp2 bonding and specimen density. The high dose high temperature specimens showed evidence of structural recovery where sp2 values are slightly higher than values associated with low dose low temperature specimens. Data from XRD, Raman, TEM, SAED and EELS showed that low dose low temperature specimens tended to exhibit higher structural damage (such as lower sp2 content, higher d-spacing, and reduced crystallite size) than high dose high temperature specimens.

36 MATERIALS SCIENCE↗

Local polar structure and multiferroic properties of (1−x)Bi{sub 0.9}Dy{sub 0.1}FeO{sub 3}−xPbTiO{sub 3} solid solution

The multiferroic (1–x)[0.9BiFeO{sub 3}–0.1DyFeO{sub 3}]–xPbTiO{sub 3} (BDF–xPT) solid solution with compositions around the morphotropic phase boundary (x = 0.25, 0.28, 0.31, 0.34, and 0.37) has been synthesized in the form of ceramics. The phase symmetry, microstructure, ferroelectricity, piezoresponse, and ferromagnetic properties have been characterized by various techniques. It is found that, with increasing content of lead titanate from x = 0.25 to x = 0.37, the grain size increases and the ferroelectric property is improved. The ferroelectric performance is further enhanced by the introduction of an excess amount (2%) of TiO{sub 2} or by sintering in oxygen atmosphere, which reduces the leakage. The local polar structure is imaged by piezoresponse force microscopy. Both the out-of-plane and in-plane images reveal distinct ferroelectric domain structures, with the amplitude and the average domain size decreasing with the increase of lead titanate amount. Compared with the (1–x)BiFeO{sub 3}–xPbTiO{sub 3} binary solid solution of about the same concentration of PT, the magnetic properties are enhanced in BDF–xPT due to the presence of dysprosium, as demonstrated by the ferromagnetic hysteresis loops displayed at room temperature and at 10 K, but the remnant magnetization decreases with increasing PT content. The simultaneous presence of ferroelectricity and ferromagnetism entitles the BDF–xPT solid solution a room-temperature multiferroic material.

36 MATERIALS SCIENCE↗

Flash x-ray radiography analysis of detonation wave propagation in additive-manufactured high explosives

Recent research has demonstrated that additive manufacturing (AM) can be used to produce directionally sensitive high explosives (HEs), but detonation wave propagation in AM HEs with variable internal structure has not been studied. In this work, samples were printed using a 73 wt. % octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine-based HE ink. Flash x-ray radiography imaging was used to observe density changes in two imaging planes of each sample during detonation, and high-speed imaging was used to calculate the detonation velocity at the HE surface. The detonation front initially appears to fail in internal channel regions of the HE, but late reactions occurred in two samples, which increased the material bulk density by 2.8%, possibly due to shock convergence phenomena. The calculated detonation wave pressure similarly increased, but the accuracy of the results is uncertain because of the deviation of the low bulk density printed samples from the cast charge principal isentrope. Here, this work demonstrates that structure can be effectively utilized to guide detonation wave propagation through HE charges.

3D printing↗

Quantum ghost imaging through turbulence

We investigate the effect of turbulence on quantum ghost imaging. We use entangled photons and demonstrate that for a specific experimental configuration the effect of turbulence can be greatly diminished. By decoupling the entangled photon source from the ghost-imaging central image plane, we are able to dramatically increase the ghost-image quality. When imaging a test pattern through turbulence, this method increases the imaged pattern visibility from V=0.15{+-}0.04 to 0.42{+-}0.04.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compressed video camera with a moving patterned disk

A high-speed video system is disclosed that includes a moving image absorbing disk at an image plane. The disk has a pattern that passes and blocks image data. The disk is located between an event and an image sensor, or reflects an image to the image sensor. The disk is rotated at a speed that matches the desired reconstructed image frame rate. The image sensor frame data is processed using image reconstruction techniques, such as the D-AMP or TWIST algorithm, to recover a time sequence of reconstructed images. Additional images can be reconstructed for each image sensor frame if some spatial resolution is sacrificed. For continuous video, the disk speed is adjusted to the sensor frame rate. For burst mode, a single sensor image is acquired and a short image sequence is reconstructed. This image capture system works with a variety of radiations, including infrared, light, UV and X-rays.

42 ENGINEERING↗

Method of forming aperture plate for electron microscope

An electron microscope is described with an electron source a condenser lens having either a circular aperture for focusing a solid cone of electrons onto a specimen or an annular aperture for focusing a hollow cone of electrons onto the specimen. It also has objective lens with an annular objective aperture, for focusing electrons passing through the specimen onto an image plane. A method of making the annular objective aperture using electron imaging, electrolytic deposition and ion etching techniques is included.

Heinemann, K.↗

Information theory analysis of sensor-array imaging systems for computer vision

Information theory is used to assess the performance of sensor-array imaging systems, with emphasis on the performance obtained with image-plane signal processing. By electronically controlling the spatial response of the imaging system, as suggested by the mechanism of human vision, it is possible to trade-off edge enhancement for sensitivity, increase dynamic range, and reduce data transmission. Computational results show that: signal information density varies little with large variations in the statistical properties of random radiance fields; most information (generally about 85 to 95 percent) is contained in the signal intensity transitions rather than levels; and performance is optimized when the OTF of the imaging system is nearly limited to the sampling passband to minimize aliasing at the cost of blurring, and the SNR is very high to permit the retrieval of small spatial detail from the extensively blurred signal. Shading the lens aperture transmittance to increase depth of field and using a regular hexagonal sensor-array instead of square lattice to decrease sensitivity to edge orientation also improves the signal information density up to about 30 percent at high SNRs.

Huck, F. O.↗

Strategy and calculations for the design of baffles for Wolter Type II telescopes

Spaceflight, stellar pointing telescopes require baffle systems to define the field of view and protect this observational area from stray and scattered light. In the case of near normal incidence telescope systems, the problem consists in controlling the stray/scattered radiation reaching the image plane when circular plates, the primary and secondary mirrors, are the imaging elements. The case addressed in this paper is quite different in that it involves baffling two conical surfaces, i.e., the primary and secondary mirrors of a Wolter Type II telescope. A strategy is described for systematically moving through the telescope system and establishing criteria for placement of baffles. Calculations are given which determine the size and number of permitted baffles as a function of practical physical parameters. Clear options are given for the design of minimum baffle lengths to meet packaging constraints.

Mangus, John D.↗

Laser beam centering and pointing system

An optical instrument aligns an optical beam without the need for physical intervention of the instrument within the apparatus or platforms from which the trajectory of the beam to be ascertained. The alignment apparatus and method enable the desired function to be realized without the placement of physical apertures or sensors directly in the path of the beam through the system whose spatial position and slope is to be sought. An image plane provides the observer with a pair of well-defined images that are indicative of the beam centering and pointing alignment parameters. The optical alignment can be realized without the need for referencing to an external or fixed set of coordinates or fiducials. The instrument can therefore service situations where adverse environments would otherwise prohibit the use of such instruments, including regions of high radiation, high temperature, vacuum and/or cryogenic atmospheres.

42 ENGINEERING↗

Utility of the Virtual Liver Parenchymal Perfusion Area Using a Commercially Available Workstation in Transarterial Chemoembolization for Hepatocellular Carcinoma

Purpose: To evaluate the accuracy of the virtual liver parenchymal perfusion area using a commercially available workstation and liver analysis software in conventional transarterial chemoembolization (cTACE) for hepatocellular carcinoma (HCC). Materials and Methods: This method was retrospectively applied to 29 treated HCCs in 23 patients. The virtual embolic area (VEA) was estimated based on cone beam computed tomography during hepatic arteriography using a commercially available workstation and liver analysis software by two observer groups (group A: experts; group B: semi-experts). The real embolic area (REA) was defined as the area where iodized oil accumulated on computed tomography at 1 week after cTACE. The REA was estimated by each of the two groups, and the mean REA between the groups (mREA) was used as a standard reference. Agreement of volume and cross-sectional area in three orthogonal planes between the VEA and mREA were analyzed using intraclass correlation coefficients (ICCs) and Bland–Altman plots. Results: The ICCs for volume between VEA and mREA were 0.97 and 0.88 for groups A and B, respectively, and those for cross-sectional area were 0.94 and 0.88 for the axial plane, 0.95 and 0.83 for the coronal plane, and 0.87 and 0.74 for the sagittal plane, respectively. Thus, the overall agreement was excellent, except for the sagittal imaging plane in group B. Conclusion: This method using a commercially available workstation and liver analysis software can be useful for estimating the embolic area in cTACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

H I ABSORPTION SPECTRA TOWARD MAGPIS SUPERNOVA REMNANT CANDIDATES

The Multi-Array Galactic Plane Imaging Survey is an ongoing project to map out the northern Galactic plane in the 21 cm radio continuum. The survey identified 30 probable supernova remnant candidates in the Galactic plane from 18 deg. <l< 32 deg. H I absorption spectra were taken toward these sources using data from the VLA Galactic Plane Survey. Using both circular and hydrodynamical Galactic rotation models, the corresponding distances were calculated. Of the 30 candidates, distances to nine of them were determined, and another eight sources had their distances constrained with upper and lower bounds. Many of these sources have detectable radio recombination line emission toward them, and we comment on the possible nature of these emissions.

79 ASTRONOMY AND ASTROPHYSICS↗

Three-dimensional visual guidance improves the accuracy of calculating right ventricular volume with two-dimensional echocardiography

Three-dimensional guidance programs have been shown to increase the reproducibility of 2-dimensional (2D) left ventricular volume calculations, but these systems have not been tested in 2D measurements of the right ventricle. Using magnetic fields to identify the probe location, we developed a new 3-dimensional guidance system that displays the line of intersection, the plane of intersection, and the numeric angle of intersection between the current image plane and previously saved scout views. When used by both an experienced and an inexperienced sonographer, this guidance system increases the accuracy of the 2D right ventricular volume measurements using a monoplane pyramidal model. Furthermore, a reconstruction of the right ventricle, with a computed volume similar to the calculated 2D volume, can be displayed quickly by tracing a few anatomic structures on 2D scans.

Non-NASA Center↗

The GMRT High Resolution Southern Sky Survey for pulsars and transients. I. survey description and initial discoveries

We are conducting a survey for pulsars and transients using the Giant Metrewave Radio Telescope (GMRT). The GMRT High Resolution Southern Sky (GHRSS) survey is an off-Galactic plane (|b| > 5) survey in the declination range −40° to −54° at 322 MHz. With the high time (up to 30.72 μs) and frequency (up to 0.016275 MHz) resolution observing modes, the 5σ detection limit is 0.5 mJy for a 2 ms pulsar with a 10% duty cycle at 322 MHz. The total GHRSS sky coverage of 2866 deg{sup 2} will result from 1953 pointings, each covering 1.8 deg{sup 2}. The 10σ detection limit for a 5 ms transient burst is 1.6 Jy for the GHRSS survey. In addition, the GHRSS survey can reveal transient events like rotating radio transients or fast radio bursts. With 35% of the survey completed (i.e., 1000 deg{sup 2}), we report the discovery of 10 pulsars, 1 of which is a millisecond pulsar (MSP), which is among the highest pulsar per square degree discovery rates for any off-Galactic plane survey. We re-detected 23 known in-beam pulsars. Utilizing the imaging capability of the GMRT, we also localized four of the GHRSS pulsars (including the MSP) in the gated image plane within ±10″. We demonstrated rapid convergence in pulsar timing with a more precise position than is possible with single-dish discoveries. We also show that we can localize the brightest transient sources with simultaneously obtained lower time resolution imaging data, demonstrating a technique that may have application in the Square Kilometre Array.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging spectrometer for high resolution measurements of stratospheric trace constituents in the ultraviolet

A high-resolution spectrometer has been developed for studies of minor constituents in the middle atmosphere at ultraviolet wavelengths. In particular, the instrument is intended for observations of upper stratospheric UV bands. The spectrometer has a slit width of 0.08 A obtained by means of an echelle grating and a cross-disperser grating. The image plane detector is an intensified CCD consisting of a high gain proximity focused image intensifier that is fiber optically coupled to a two-dimensional CCD array. An instantaneous bandwidth of 9.2 A is resolved across 488 pixels at 0.018 A/pixel, permitting simultaneous acquisition of multiple lines of selected OH bands and the neighboring background. The spectrometer and the approach have been successfully demonstrated as a technique for measuring the concentration of OH on two high-altitude balloon flights. This paper reports the instrument design and its achieved performance.

Torr, Marsha R.↗

Reliable vision-guided grasping

Automated assembly of truss structures in space requires vision-guided servoing for grasping a strut when its position and orientation are uncertain. This paper presents a methodology for efficient and robust vision-guided robot grasping alignment. The vision-guided grasping problem is related to vision-guided 'docking' problems. It differs from other hand-in-eye visual servoing problems, such as tracking, in that the distance from the target is a relevant servo parameter. The methodology described in this paper is hierarchy of levels in which the vision/robot interface is decreasingly 'intelligent,' and increasingly fast. Speed is achieved primarily by information reduction. This reduction exploits the use of region-of-interest windows in the image plane and feature motion prediction. These reductions invariably require stringent assumptions about the image. Therefore, at a higher level, these assumptions are verified using slower, more reliable methods. This hierarchy provides for robust error recovery in that when a lower-level routine fails, the next-higher routine will be called and so on. A working system is described which visually aligns a robot to grasp a cylindrical strut. The system uses a single camera mounted on the end effector of a robot and requires only crude calibration parameters. The grasping procedure is fast and reliable, with a multi-level error recovery system.

Nicewarner, Keith E.↗