Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Anhydrous vs Hydrated f-Element Acetate Polymers Dictated by the Stoichiometry of Protic Acidic/Basic Azole Mixtures

Continuing our investigations of ionic liquid (IL) based routes to a library of f-element/soft donor complexes which could be studied crystallographically, we have explored the dissolution of f-element salts in protic imidazole-based ILs containing only soft donors at high temperatures to drive off volatiles, including water and carboxylic or mineral acids. Here we present our results, reacting acidic and basic azoles in 1:3 or 1:1 stoichiometric compositions at elevated temperature, followed by saturation with Nd(OAc) 3 ·xH 2 O or Ce(OAc) 3 ·xH 2 O, which led to 13 new metal–acetate polymeric complexes identified by single-crystal X-ray diffraction. We found that the diversity in coordination modes of the simple acetate ligand that interfere with substitution of the softer N donors led to several readily crystallizable complexes forming two distinct groups with respect to f-element interaction with the ionic liquid precursors. When the acidic/basic azole ratio was 1:3, acetate and a neutral basic azole were found to be coordinated to the metal centers but no water, although in one case (2) water was observed in the secondary coordination sphere: [Ce(μ 2 -OAc) 3 (C 1 im)] n (1, C 1 im = 1-methylimidazole), [Nd(μ 2 -(OAc) 3 (C 1 im)] n ·nH 2 O (2), [Ce(μ 2 -OAc) 3 (C 2 im)] n (3, C 2 im = 1-ethylimidazole), [Ln(μ 2 -OAc) 3 DMF] n (Ln = Nd (4), Ce (5); dimethylformamide (DMF) was substituted for the azole mixture), and [Nd(μ 2 -OAc) 3 (C 4 im)] n (6, C 4 im = 1-butylimidazole). However, when the stoichiometric ratio was 1:1, water was always observed coordinated to the metal ions with the acidic azole included in the structure as a solvate or cocrystal, despite a higher reaction temperature: [Nd(μ 2 -OAc) 3 (OH 2 )] n ·n(1,2,3-Taz) (7, 1,2,3-Taz = 1,2,3-triazole), [Ln(μ 2 -OAc) 3 (OH 2 )] n ·n(4,5-DCim) (Ln = Nd (8), Ce (9), 4,5-DCim = 4,5-dicyanoimidazole), [Ln(μ 2 -OAc) 3 (OH 2 )] n ·n(3,5-diNH 2 -1,2,4-Taz) (Ln = Nd (10), Ce (11), 3,5-diNH 2 -1,2,4-Taz = 3,5-diamino-1,2,4-triazole), [Ce(μ 2 -OAc) 3 (OH 2 )] n ·n(3-NH 2 -1,2,4-Taz) (12, 3-NH 2 -1,2,4-Taz = 3-amino-1,2,4-triazole), and [Nd(μ 2 -OAc) 3 (OH 2 )] n ·n(5-NH 2 -Tz) (13, 5-NH2-Tz = 5-aminotetrazole). All of the compounds retain the Ln:OAc– ratio of 1:3 and form 1D polymeric chains; however, they exhibit a variety of coordination modes affecting the degree of chain condensation. The isolation of both hydrated and anhydrous products revealed different abilities of the investigated soft N-donors to compete with O-donors finding their place in the coordination sphere of the lanthanide or in the crystal lattice.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

Ion mobility spectrometry (IMS) is a gas-phase analytical technique that separates ions with different sizes and shapes and is compatible with mass spectrometry (MS) to provide an additional separation dimension. The rapid nature of the IMS separation combined with the high sensitivity of MS-based detection and the ability to derive structural information on analytes in the form of the property collision cross section (CCS) makes IMS particularly well-suited for characterizing complex samples in -omics applications. In such applications, the quality of CCS from IMS measurements is critical to confident annotation of the detected components in the complex -omics samples. However, most IMS instrumentation in mainstream use requires calibration to calculate CCS from measured arrival times, with the most notable exception being drift tube IMS measurements using multifield methods. The strategy for calibrating CCS values, particularly selection of appropriate calibrants, has important implications for CCS accuracy, reproducibility, and transferability between laboratories. The conventional approach to CCS calibration involves explicitly defining calibrants ahead of data acquisition and crucially relies upon availability of reference CCS values. In this work, we present a novel reference-free approach to CCS calibration which leverages trends among putatively identified features and computational CCS prediction to conduct calibrations post-data acquisition and without relying on explicitly defined calibrants. We demonstrated the utility of this reference-free CCS calibration strategy for proteomics application using high-resolution structures for lossless ion manipulations (SLIM)-based IMS-MS. In conclusion, we first validated the accuracy of CCS values using a set of synthetic peptides and then demonstrated using a complex peptide sample from cell lysate.

59 BASIC BIOLOGICAL SCIENCES↗

Surface directed reversible imidazole ligation to nickel(ii) octaethylporphyrin at the solution/solid interface: a single molecule level study

Scanning tunneling microscopy (STM) is used to study for the first time the reversible binding of imidazole (Im) and nickel(II) octaethylporphyrin (NiOEP) supported on highly oriented pyrolytic graphite (HOPG) at the phenyloctane/NiOEP/HOPG interface at 25 °C. The ligation of Im to the NiOEP receptor while not observed in fluid solution is readily realized at the solution/HOPG interface. The coordination process scales with increasing Im concentration and can be effectively modeled by the Langmuir isotherm. At room temperature it is determined that the standard free energy of adsorption is ΔG c = -15.8 kJ mol -1 and the standard enthalpy of adsorption is estimated to be ΔH c ≈ -80 kJ mol -1 . The reactivity of imidazole toward NiOEP adsorbed on HOPG is attributed to charge donation from the graphite stabilizing the Im–Ni bond. This charge transfer pathway is supported by molecular and periodic modeling calculations which indicate that the Im ligand behaves as a π-acceptor. DFT calculations also show that the nickel ion in the Im–NiOEP/HOPG complex is in a singlet ground state. This is surprising since both our calculations and previous experimental studies find a triplet ground state for the five and six coordinated Im–nickel(II) porphyrins in the gas-phase or in solution. Both the experimental and the theoretical findings provide information that is useful for better understanding of chemical sensing/recognition and catalytic processes that utilize metal–organic complexes adsorbed on surfaces where the reactivity of the metal is moderated by the substrate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis and characterization of imidazolium-mediated Tröger's base containing poly(amide)-ionenes and composites with ionic liquids for CO 2 separation membranes

Considerable attention has been given to polymeric membranes either containing, or built from, ionic liquids (ILs) in gas separation processes due to their selective separation of CO 2 molecules. Achieving high-performance CO 2 separation membranes with enhanced permeability and selectivity relies mainly on rationally designing the molecular substructure and molecular composition of the polymer matrix. In this work, we have exclusively explored a facile synthetic route to incorporate aromatic amide linkages onto an ionene backbone derived from imidazolium-mediated Tröger's base moieties, yielding a novel rigid polyamide-ionene material (“Im-TB-PA ionene”). We have optimized two novel Im-TB-PA ionene polymers via Menshutkin reactions between N,N'-(1,4-phenylene)bis(4-(chloromethyl)benzamide) and equimolar amounts of two isomeric diimidazole-functionalized Tröger's base monomers with ‘ortho’ or ‘para’ regiochemistry. The two resulting Im-TB(o&p)-PA ionenes exhibited high molecular weights and excellent solubilities in polar organic solvents, serving homogeneous and mechanically stable blend membranes with “free” ILs. The structural and physical properties, as well as the gas separation behaviors of both the Im-TB(o&p)-PA ionenes and their IL composite counterparts ([Im-TB(o&p)-PA] + [IL]), were further extensively investigated. The membrane with an optimal composition and polymer architecture ([Im-TB(o)-PA] + [IL]) exhibited outstanding permselectivites for CO 2 /CH 4 (46.73), CO 2 /N 2 (51.74), and CO 2 /H 2 (4.38) gas pairs together with the best CO 2 permeability of 47.2 barrer. Altogether, this study provides a promising strategy to explore the benefits of Im-TB-PA ionenes to separate CO 2 from flue gas, natural gas, and syngas streams, while opening new possibilities in polymer design with strong candidate materials for other practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A SAMPLE OF INTERMEDIATE-MASS STAR-FORMING REGIONS: MAKING STARS AT MASS COLUMN DENSITIES <1 g cm{sup -2}

In an effort to understand the factors that govern the transition from low- to high-mass star formation, for the first time we identify a sample of intermediate-mass star-forming regions (IM SFRs) where stars up to (but not exceeding) {approx}8 M{sub sun} are being produced. We use IRAS colors and Spitzer Space Telescope mid-IR images, in conjunction with millimeter continuum and {sup 13}CO maps, to compile a sample of 50 IM SFRs in the inner Galaxy. These are likely to be precursors to Herbig AeBe stars and their associated clusters of low-mass stars. IM SFRs constitute embedded clusters at an early evolutionary stage akin to compact H II regions, but they lack the massive ionizing central star(s). The photodissociation regions that demarcate IM SFRs have typical diameters of {approx}1 pc and luminosities of {approx}10{sup 4} L{sub sun}, making them an order of magnitude less luminous than (ultra-)compact H II regions. IM SFRs coincide with molecular clumps of mass {approx}10{sup 3} M{sub sun} which, in turn, lie within larger molecular clouds spanning the lower end of the giant molecular cloud mass range, 10{sup 4}-10{sup 5} M{sub sun}. The IR luminosity and associated molecular mass of IM SFRs are correlated, consistent with the known luminosity-mass relationship of compact H II regions. Peak mass column densities within IM SFRs are {approx}0.1-0.5 g cm{sup -2}, a factor of several lower than ultra-compact H II regions, supporting the proposition that there is a threshold for massive star formation at {approx}1 g cm{sup -2}.

79 ASTRONOMY AND ASTROPHYSICS↗

Structure, function, and evolution of bacterial ATP-binding cassette systems

The ATP-binding cassette (ABC) systems constitute one of the largest superfamilies of paralogous sequences. All ABC systems share a highly conserved ATP-hydrolyzing domain or protein (the ABC; also referred to as a nucleotide-binding domain [NBD]) that is unequivocally characterized by three short sequence motifs (Fig. 1): these are the Walker A and Walker B motifs, indicative of the presence of a nucleotide-binding site, and the signature motif, unique to ABC proteins, located upstream of the Walker B motif (426). Other motifs diagnostic of ABC proteins are also indicated in Fig. 1. The biological significance of these motifs is discussed in Structure, Function, and Dynamics of the ABC. ABC systems are widespread among living organisms and have been detected in all genera of the three kingdoms of life, with remarkable conservation in the primary sequence of the cassette and in the organization of the constitutive domains or subunits (203, 420). ABC systems couple the energy of ATP hydrolysis to an impressively large variety of essential biological phenomena, comprising not only transmembrane (TM) transport, for which they are best known, but also several non-transport-related processes, such as translation elongation (62) and DNA repair (174). Although ABC systems deserve much attention because they are involved in severe human inherited diseases (107), they were first discovered and characterized in detail in prokaryotes, as early as the 1970s (13, 148, 238, 468). The most extensively analyzed systems were the high-affinity histidine and maltose uptake systems of Salmonella enterica serovar Typhimurium and Escherichia coli. Over 2 decades ago, after the completion of the nucleotide sequences encoding these transporters in the respective laboratories of Giovanna Ames and Maurice Hofnung, Hiroshi Nikaido and colleagues noticed that the two systems displayed a global similarity in the nature of their components and, moreover, that the primary sequences of MalK and HisP, the proteins suspected to energize these transporters, shared as much as 32% identity in amino acid residues when their sequences were aligned (171). Later, it was found that several bacterial proteins involved in uptake of nutrients, export of toxins, cell division, bacterial nodulation of plants, and DNA repair displayed the same similarity in their sequences (127, 196). This led to the notion that the conserved protein, which had been shown to bind ATP (198, 201), would probably energize the systems mentioned above by coupling the energy of ATP hydrolysis to transport. The latter was demonstrated with the maltose and histidine transporters by use of isolated membrane vesicles (105, 379) and purified transporters reconstituted into proteoliposomes (30, 98). The determination of the sequence of the first eukaryotic protein strongly similar to these bacterial transporters (the P-glycoprotein, involved in resistance of cancer cells to multiple drugs) (169, 179) demonstrated that these proteins were not restricted to prokaryotes. Two names, 'traffic ATPases' (15) and the more accepted name 'ABC transporters' (193, 218), were proposed for members of this new superfamily. ABC systems can be divided into three main functional categories, as follows. Importers mediate the uptake of nutrients in prokaryotes. The nature of the substrates that are transported is very wide, including mono- and oligosaccharides, organic and inorganic ions, amino acids, peptides, ironsiderophores, metals, polyamine cations, opines, and vitamins. Exporters are involved in the secretion of various molecules, such as peptides, lipids, hydrophobic drugs, polysaccharides, and proteins, including toxins such as hemolysin. The third category of systems is apparently not involved in transport, with some members being involved in translation of mRNA and in DNA repair. Despite the large, diverse population of substrates handled and the difference in the polarity of transport, importers and exporters share a common organization made of two hydrophobic membrane-spanning or integral membrane (IM) domains and two hydrophilic domains carrying the ABC peripherally associated with the IM domains on the cytosolic side of the membrane (26). In importers, these four domains are almost always independent polypeptide chains that come together to form a multimeric complex. In most exporters, including the E. coli hemolysin exporter HlyB, the N-terminal IM and the C-terminal ABC domains are fused as a single polypeptide chain (IM-ABC). An inverted organization in which the IM domain is C-terminal with respect to the ABC domain (ABC-IM) exists, such as in the MacB protein, involved in macrolide resistance in E. coli. No IM domain partners have been identified for ABC proteins falling into the third category, and these proteins consist of two ABCs fused together (ABC2).

59 BASIC BIOLOGICAL SCIENCES↗

Measuring Cellular-scale Nutrient Distribution in Algal Biofilms with Synchrotron Confocal Infrared Microspectroscopy

The microscope and infrared spectrometer are two of the most useful tools for the study of biological materials, and their combined analytical power far exceeds the sum of the two. Performing molecular spectroscopy through a microscope superimposes chemical information onto the physical microstructure obtained from the optical microscope when visible and infrared information are collected under the same conditions. The instrument developments that enable current infrared microspectroscopic studies began with the introduction of the first research-grade infrared microscope, patented in 1989 (1). By 1993, published reports using this method to determine macroalgae (seaweed) cell-wall composition appeared (2-4). Since these initial reports, the use of infrared microspectroscopy (IMS) in microalgal (single cells or groups of cells) research has grown. Primarily, cultured algae have been used to hone IMS methodology and evaluate its capabilities in algal research (5-8). Studies involving natural, mixed species assemblages, which can utilize the spatial resolution potential of this technique fully are rare (9-11). For instance, in a recent review of IMS microalgal ecological research (12), only 3 of the 29 peer-reviewed publications investigated natural algal assemblages. Both thermal and synchrotron infrared sources provide a resolution capable of measuring individual algae in mixed species assemblages, and each has its advantages. For example, thermal source IMS is more accessible, allowing more samples to be analyzed than synchrotron IMS. However, synchrotron IMS with confocal masking provides superior resolution, which can be critical in isolating small or contiguous cells. Algal ecology is the study of the interaction between algae and their environment. Infrared microspectroscopy addresses a major logistical problem in this field, obtaining species-specific cellular biochemical information from natural, mixed-species assemblages (11,12). Benthic (bottom-dwelling) algae, for example, grow in a three-dimensional matrix (biofilm) composed of different cell sizes, shapes, and configurations. The optical and ecological challenge of studying algae is apparent from Figure 1, which shows a photomicrograph of algal chlorophyll fluorescence on a rock. Several issues make it difficult to obtain single species measurements with standard techniques: cell sizes can vary over an order of magnitude; species can occur as single cells, long filaments, or globular colonies; a number of different species can be found within a few square millimeters; and fluorescence can vary across cells (that is, the physiological state varies across cells). Synchrotron IMS is a tool that can be used to begin to overcome these spatially related challenges by giving a species- and location-specific measurement of an individual alga's relative chemical composition and distribution. This technique enables algal ecologists to focus on new, ecologically relevant questions such as what level (that is, cell, colony, and population) best defines a species' response to environmental change. For instance, many species occur as single cells and thus can be measured as individual organisms. However, the variety of growth forms and sizes can make it difficult to define the best unit to measure multicellular groups in terms of its functional role such as primary productivity (that is, carbon incorporation) and nutrient cycling. Understanding how individual algal species within a diverse community respond to environmental changes can help predict how changes in assemblage structure will impact overall assemblage function.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Hydrology and Interim Measure Performance in the Chromium Plume at Los Alamos National Laboratory - 20498

Hexavalent chromium, Cr(VI), is present in the regional aquifer beneath Los Alamos National Laboratory (LANL) at concentrations greater than the New Mexico groundwater standard (50 ppb). The source of the Cr is blowdown from a power plant where potassium dichromate was used as a corrosion inhibitor from 1956 to 1972. Blowdown comingled with effluent from another source and migrated approximately 3 miles down a canyon, primarily as surface flow, until reaching an alluvial infiltration zone. The infiltrating water moved vertically through a thick (approximately 900 ft), complex stratigraphic sequence of unsaturated tuffs, basalt, and unconsolidated alluvial deposits. Horizontal transport also took place within spatially limited perched groundwater horizons in the vadose zone (VZ). Breakthrough at the regional aquifer water table is thought to have occurred in multiple hydraulic windows or 'drip points' located approximately 3 miles from the initial release site at the power plant. The regional aquifer is highly heterogeneous and anisotropic, and displays unconfined behavior in an upper zone and confined behavior at depth. The Cr(VI) contamination has so far remained confined to the upper approximately 25 m of the aquifer. The ambient hydraulic gradient in the regional aquifer is toward the east/southeast, but the water table is extremely flat in the Cr plume area compared to surrounding areas. There is some local variability in flow direction, potentially related to effects of seasonal pumping from nearby Los Alamos county water-supply wells, which draw from the regional aquifer several hundred feet below the water table. An interim measure (IM) is currently operating at the site to achieve hydraulic control of plume migration using a series of extraction wells, ion-exchange treatment, and injection along the downgradient portion of the plume. The migration of Cr contamination in the aquifer has been previously evaluated using a calibrated probabilistic numerical model, which has also been used to design the spatial configuration of extraction and injection wells for the IM, and to identify locations for monitoring wells. The model is built using the Finite Element Heat and Mass (FEHM) transfer code, and the Model Analysis and Decision Support (MADS) software is used for analyses. To date, the portion of the IM system that has operated in a continuous manner has been very effective at hydraulic control. Modifications to the flow field associated with the influence of IM pumping and injection are evaluated here, with modeling constraints to be provided by recent observations of tracers injected into both monitoring wells and IM injection wells, as well as opportunistic observations of geochemical signatures of treated ion-exchange effluent injected into IM injection wells. The tracer and geochemical data provide insights into modified flow directions within the Cr plume area that cannot be otherwise obtained. Results of the modeling work are being used to inform adaptive management of IM operations and will be a valuable tool for development and refinement of long-term remediation strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Mobility Spectrometry-Mass Spectrometry for High-Throughput Analysis

Ion mobility spectrometry is a widely used analytical technique providing gas phase separation of molecules. It has received increasing attention in the recent years with the advancement in technology development and the availability of commercial instruments. In this chapter, we introduced the ion mobility fundamental theory and provided examples of IMS applications, especially for isomer separation, collision cross section database generation, high throughput analysis workflows, software tools for IMS data analysis, and ongoing high resolution SLIM IMS development. While IMS is not yet routinely utilized in drug discovery and pharmaceutical industry, there has been increased interest in high throughput library screening and antibody characterization. With all the ongoing development in IMS technology and informatics, we foresee more and more exciting applications of high throughput IMS analysis in different fields including omics studies, drug discovery and clinical applications in the near future.

Ross, Dylan H.↗

Computational tools and algorithms for ion mobility spectrometry-mass spectrometry

Ion mobility spectrometry-mass spectrometry (IMS-MS or IM-MS) is a powerful analytical technique that combines the gas-phase separation capabilities of IM with the identification and quantification capabilities of MS. IM-MS can differentiate molecules with indistinguishable masses but different structures (e.g., isomers, isobars, molecular classes, and contaminant ions). The importance of this analytical technique is reflected by a staged increase in the number of applications for molecular characterization across a variety of fields, from different MS-based omics (proteomics, metabolomics, lipidomics, etc.) to the structural characterization of glycans, organic matter, proteins, and macromolecular complexes. With the increasing application of IM-MS there is a pressing need for effective and accessible computational tools. This article presents an overview of the most recent free and open-source software tools specifically tailored for the analysis and interpretation of data derived from IM-MS instrumentation. This review enumerates these tools and outlines their main algorithmic approaches, while highlighting representative applications across different fields. Finally, a discussion of current limitations and expectable improvements is presented.

59 BASIC BIOLOGICAL SCIENCES↗

Principles of Ion Selection, Alignment, and Focusing in Tandem Ion Mobility Implemented Using Structures for Lossless Ion Manipulations (SLIM)

Tandem ion mobility (IM) enables the characterization of subpopulations of ions from larger ensembles, including differences that cannot be resolved in a single dimension of IM. Tandem IM consists of at least two IM regions that are each separated by an ion selection region. In many implementations of tandem IM, ions eluting from a dimension of separation are filtered and immediately transferred to the subsequent dimension of separation (selection-only experiments). We recently reported a mode of operation in which ions eluting from a dimension are trapped prior to the subsequent dimension (selection-trapping experiments), which was implemented on an instrument constructed using the structures for lossless ion manipulations (SLIM) architecture. Here, we use a combination of experiments and trajectory simulations to characterize aspects of the selection, trapping, and separation processes underlying these modes of operation. For example, the actual temporal profile of filtered ions can be very similar to the width of the waveforms used for selection, but depending on experimental parameters, can differ by up to ± 500 μs. Experiments and simulations indicate that ions in selection-trapping experiments can be spatially focused between dimensions, which removes the broadening that occurred during the preceding dimension. During focusing, individual ions are thermalized, which aligns and establishes common initial conditions for the subsequent dimension. Therefore, selection-trapping experiments appear to offer significant advantages relative to selection-only experiments, which we anticipate will become more pronounced in future experiments that make use of longer IM separations, additional dimensions of analysis, and the outcomes of this study. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Utilizing ion mobility spectrometry and mass spectrometry for the analysis of polycyclic aromatic hydrocarbons, polychlorinated biphenyls, polybrominated diphenyl ethers and their metabolites

Polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) are persistent environmental pollutants originating from incomplete combustion of organic materials and synthetic sources. PAHs, PCBs, and PBDEs have all been shown to have a significant effect on human health with correlations to cancer and other diseases. Therefore, measuring the presence of these xenobiotics in the environment and human body is imperative for assessing their health risks. To date, their analyses require both gas chromatography and liquid chromatography separations in conjunction with mass spectrometry measurements for detection of both the parent molecules and their hydroxylated metabolites, making their studies extremely time consuming. In this work, we characterized PAHs, PCBs, PBDEs and their hydroxylated metabolites using ion mobility spectrometry coupled with mass spectrometry (IMS-MS) and in combination with different ionization methods including electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). The collision cross section and m/z trend lines derived from the IMS-MS analyses displayed distinct trends for each molecule type. Additionally, the rapid isomeric and molecular separations possible with IMS-MS showed great promise for quickly distinguishing the parent and metabolized PAH, PCB, and PDBE molecules in complex environmental and biological samples.

Zheng, Xueyun (ORCID:0000000197824521)↗

Development of a new ion mobility time-of-flight mass spectrometer

Complex samples require multidimensional measurements with high resolution for full characterization of biological and environmental systems. To address this challenge, we developed a drift tube-based ion mobility spectrometry-Orbitrap mass spectrometry (IMS-Orbitrap MS) platform. To circumvent the timing difference between the fast IMS separation and the slow Orbitrap MS acquisition, we utilized a dual gate and pseudorandom sequence to multiplex ions into the drift tube and Orbitrap. The instrument was designed to operate in signal averaging (SA), single multiplexing (SM) and double multiplexing (DM) IMS modes to fully optimize the signal-to-ratio of the measurements. For the SM measurements, a previously developed algorithm was used to reconstruct the IMS data, while a new algorithm was developed for the DM analyses. The new algorithm is a two-step process that first recovers the SM data from the encoded DM data and then decoded the SM data. The algorithm also performs multiple refining procedures in order to minimize the demultiplexing artifacts traditionally observed in such scheme. The new IMS-Orbitrap MS platform was demonstrated for the analysis of proteomic and petroleum samples, where the integration of IMS and high mass resolution proved essential for accurate assignment of molecular formulae.

47 OTHER INSTRUMENTATION↗

GraMeR: Gra ph Me ta R einforcement learning for multi-objective influence maximization

Influence maximization (IM) is a combinatorial problem of identifying a subset of seed nodes in a network (graph), which when activated, provide a maximal spread of influence in the network for a given diffusion model and a budget for seed set size. IM has numerous applications such as viral marketing, epidemic control, sensor placement and other network-related tasks. However, its practical uses are limited due to the computational complexity of current algorithms. Recently, deep reinforcement learning has been leveraged to solve IM in order to ease the computational burden. However, there are serious limitations in current approaches, including narrow IM formulation that only consider influence via spread and ignore self-activation, low scalability to large graphs, and lack of generalizability across graph families leading to a large running time for every test network. In this work, we address these limitations through a unique approach that involves: (1) Formulating a generic IM problem as a Markov decision process that handles both intrinsic and influence activations; (2)incorporating generalizability via meta-learning across graph families. There are previous works that combine deep reinforcement learning with graph neural network, but this work solves a more realistic IM problem and incorporates generalizability across graphs via meta reinforcement learning. Extensive experiments are carried out in various standard networks to validate performance of the proposed Graph Meta Reinforcement learning (GraMeR) framework. Finally, the results indicate that GraMeR is multiple orders faster and generic than conventional approaches when applied on small to medium scale graphs.

97 MATHEMATICS AND COMPUTING↗

Greatly Increasing Trapped Ion Populations for Mobility Separations Using Traveling Waves in Structures for Lossless Ion Manipulations

The initial use of traveling waves (TW) for ion mobility (IM) separations using a structures for lossless ion manipulations (SLIM) employed an ion funnel trap (IFT) to accumulate ions from a continuous electrospray ionization source, and limited to injected ion populations of ~106 charges due to the onset of space charge effects in the trapping region. Additional limitations arise due to the loss of resolution for the injection of ions over longer periods (e.g. in extended pulses). In this work a new SLIM ‘flat funnel’ (FF) module has been developed and demonstrated to enable the accumulation of much larger ion populations and their injection for IM separations. Ion current measurements indicate a capacity of ~3.2×108 charges for the extended trapping volume, over an order of magnitude greater than the IFT. The orthogonal ion injection into a funnel shaped separation region can greatly reduce space charge effects during the initial IM separation stage, and the gradually reduced width of the path allows the ion packet to be increasingly compressed in the lateral dimension as the separation progresses, allowing e.g. efficient transmission through conductance limits or compatibility with subsequent ion manipulations. This work examined the TW, RF, and DC confining field SLIM parameters involved in ion accumulation, injection, transmission and separation in the FF IM module using both direct ion current and MS measurements. Wide m/z range ion transmission is demonstrated, along with significant increases in signal to noise (S/N) ratios due to the larger ion populations injected. Additionally, we observed a reduction in the chemical background, which was attributed to more efficient desolvation of solvent related clusters over the extended ion accumulation periods. The TW SLIM FF IM module is anticipated to be especially effective as a front end for long path SLIM IM separation modules.

Environmental Molecular Sciences Laboratory↗

Development of an Ion Mobility Spectrometry-Orbitrap Mass Spectrometer Platform

Complex samples benefit from multidimensional measurements where higher resolution enables more complete characterization of biological and environmental systems. To address this challenge, we developed a drift tube-based ion mobility spectrometry-Orbitrap mass spectrometer (IMS-Orbitrap MS) platform. To circumvent the time scale disparity between the fast IMS separation and the much slower Orbitrap MS acquisition, we utilized a dual gate and pseudorandom sequences to multiplexed injection of ions and allowing operation in signal averaging (SA), single multiplexing (SM) and double multiplexing (DM) IMS modes to optimize the signal-to-noise ratio of the measurements. For the SM measurements, a previously developed algorithm was used to reconstruct the IMS data. A new algorithm was developed for the DM analyses involving a two-step process that first recovers the SM data and then decodes the SM data. The algorithm also performs multiple refining procedures in order to minimize demultiplexing artifacts. The new IMS-Orbitrap MS platform was demonstrated by the analysis of proteomic and petroleum samples, where the integration of IMS and high mass resolution proved essential for accurate assignment of molecular formulae.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Online Ozonolysis Combined with Ion Mobility-Mass Spectrometry Provides a New Platform for Lipid Isomer Analyses

One of the most significant challenges in contemporary lipidomics lies in the separation and identification of lipid isomers that differ only in site(s) of unsaturation or geometric configuration of the carbon-carbon double bonds. While analytical separation techniques including ion mobility spectrometry (IMS) and liquid chromatography (LC) can separate isomeric lipids under appropriate conditions, conventional tandem mass spectrometry cannot provide unequivocal identification. To address this challenge, we have implemented ozone-induced dissociation (OzID) in-line with LC, IMS and high resolution mass spectrometry. Modification of an IMS- capable quadrupole time-of-flight mass spectrometer was undertaken to allow the introduction of ozone into the high-pressure trapping ion funnel region preceding the IMS cell. This enabled the novel LC-OzID-IMS-MS configuration where ozonolysis of ionized lipids occurred rapidly (10 ms) without prior mass-selection. LC-elution time alignment combined with accurate mass and arrival time extraction of ozonolysis products facilitated correlation of precursor and product ions without mass-selection (and associated reductions in duty cycle). Unsaturated lipids across 11 classes were examined using this workflow in both positive and negative ion modalities and in all cases the positions of carbon-carbon double bonds were unequivocally assigned based on predictable OzID transitions. Under these conditions geometric isomers exhibited different IMS arrival time distributions and distinct OzID product ion ratios providing a means for discrimination of cis/trans double bonds in complex lipids. The combination of OzID with multidimensional separations shows significant promise for facile profiling of unsaturation patterns within complex lipidomes.

Environmental Molecular Sciences Laboratory↗

Rapid and Simultaneous Characterization of Drug Conjugation in Heavy and Light Chains of a Monoclonal Antibody Revealed by High-Resolution Ion Mobility Separations in SLIM

Antibody-drug conjugates (ADCs) have recently gained traction in the biomedical community due to their promise for human therapeutics and an alternative to chemotherapy for cancer. Crucial metrics for ADC efficacy, safety, and selectivity are their drug-antibody ratios (DARs). However, DAR characterization (i.e., determining the average number of conjugated drugs on the antibody) through analytical methods remains challenging due to the heterogeneity of drug conjugation as well as the numerous post-translational modifications possible in the monoclonal antibody. In this work, we report on the use of high-resolution ion mobility spectrometry separations in our structures for lossless ion manipulations coupled to mass spectrometry (SLIM IMS-MS) platform for the rapid and simultaneous characterization of the drug load profile (i.e., stoichiometric distribution of the number of conjugated drugs present on the mAb), determination of the weighted average DAR in both the heavy and light chains of a model antibody-drug conjugate, and calculation of the overall DAR of the ADC. After chemical reduction of the ADC and a subsequent 31.5 meter SLIM IMS separation the various drug bound antibody species could be well resolved for both chains. Furthermore, we also show that higher resolution separations were possible with SLIM IMS as compared to ones performed on a commercially available (~1 meter) drift tube IMS-MS platform. Interestingly, additional gas-phase substructures become evident with longer path length SLIM IMS, potentially providing insight related to how drug conjugation may alter the structural properties of a monoclonal antibody and thus affect its overall potency and/or selectivity for a given antigen. We expect high-resolution SLIM IMS separations will augment the existing toolbox for ADC characterization, particularly for structural confirmation to enable the rapid optimization of DAR for a given ADC and thus better understand its potential toxicity and potency.