Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IEEE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

How Inverter-Based Resources (IBRs) Affect Protection Relay Elements

This presentation starts with the details of IEEE 2800-2022 requirements of IBR for balanced and unbalanced faults. Then, it shows how to design a droop based GFM control to be IEEE 2800-2022 compliant. An performance evaluation is carried out to see if three OEM GFM inverters 2800-2022 compliant or not. And finally we show how IEEE 2800-2022 complaint and non-compliant GFM inverter will impact the transmission line protection elements, such as directional element and FID. Finally, recommendations are made if the GFM is not IEEE 2800-2022 compliant to disable the protection elements that rely on reliable and regulated negative sequence current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Grid Strength under Uncertain Renewable Generation

The increasing displacement of synchronous generators with renewable resources such as wind and solar via power electronic interfaces causes a reduction in short-circuit strength and weak grid issues. The variation and uncertainty of renewable energy increase challenges for identifying weak grid conditions. This paper proposes an efficient method to analyze the impact of uncertain renewable energy on grid strength. The proposed method uses the probabilistic collocation method (PCM) to approximate the results of grid strength assessment under uncertain renewable generation, in order to reduce computational burden without compromising result accuracy when compared with traditional Monte Carlo simulation (MCS). To improve the accuracy of the approximation results, the proposed method integrates the K-means clustering technique with PCM to select the approximation samples of input variables. The efficacy of the proposed method is demonstrated by comparison with MCS on the modified IEEE 9-bus system and modified IEEE 39-bus system with multiple renewable generators.

grid strength↗

Grid Application and Controls Development for Medium-Voltage SiC-Based Grid Interconnects

This paper studies, the grid-interconnection requirements of directly connected medium-voltage (MV) Silicon Carbide-based (SiC-based) converters and details the necessary control implementations. These power electronic converters follow the interconnection standard IEEE 1547-2018, but can also have additional controls supported by the microgrid standards in IEEE 2030.7, which is demonstrated in this work. Additionally, this paper defines the grid applications realized by these directly connected medium-voltage power electronic converters at the distribution scale and demonstrates results. The controls for the studied grid applications are then developed and implemented on the controller. The paper also includes details of the control algorithm development and validations of the control algorithm through hardware-in-the-loop results.

28 EE - Advanced Manufacturing Office (EE-5A)↗

A Benchmark Case for the Grid Survivability Analysis

Among current priorities of the power system analysis is the development of metrics and computational tools for the resilience analysis during catastrophic events. New methods and tools are required for such an analysis and they have to be validated prior application to real systems. However, benchmark problems are not readily available due to the analysis novelty. The current paper presents a case based on the IEEE 14-bus system for this purpose. The grid is simplified to a graph with nodes representing generators, loads, and buses. Power inputs are imported from real-time simulations of the IEEE 14-bus system. Outcomes of all possible combinations of failed elements are presented in terms of probabilities for the grid to survive, partially survive, or fail. Only the power grid's ability to withstand adverse events (survivability) is analyzed. The grid's recoverability, the other part of the resilience analysis, is not considered.

power system↗

A Medium-/Low-Voltage Joint State Estimator Through Linear Uncertainty Propagation

Traditionally, distribution system state estimations (DSSE) are challenged by the lack of measurements at both primary and secondary sides of the system. The widely available cable television (CATV) voltage sensors installed in low-voltage (LV) networks bring opportunities to achieve higher quality DSSE covering a broader area of the distribution network. This study proposes a medium-/low-voltage (MV/LV) joint distribution system state estimation approach using the untapped CATV measurements. It aims at addressing the need for system situational awareness at the grid edge while improving the estimation accuracy at both the primary and secondary sides compared to its disjointed counterpart. Linearized measurement functions and boundary condition uncertainty propagation rules are derived to ensure the computational efficiency and accuracy of the joint state estimator. Numerical experiments are conducted on an IEEE test feeder to demonstrate the efficacy of the proposed method and the value of CATV measurements.

joint state estimation↗

Recommendations for Data-in-Transit Requirements for Securing DER Communications

With the adoption of Distributed Energy Resource (DER) interoperability standards, common communication protocols are now being deployed between power system operators and DER devices. In 2018, a revision to the US interconnection and interoperability standard, Institute of Electrical and Electronics Engineers (IEEE) Std. 1547, required DER equipment to have an IEEE 2030.5, IEEE 1815, or SunSpec Modbus communication exchange interface. This change supports the future transition to secure connection and exchange of information between the DER equipment and implementing parties, such as grid operators. Adoption of standardized communication protocols and associated information models is a critical step toward interoperability between power system operators and DER, such as photovoltaic (PV) and energy storage systems. However, security requirements for these standardized communication protocols are not comprehensive, resulting in non-standard and vendor-specific implementation that may leave DER equipment susceptible to cyberattacks. This paper examines the data-in-flight security requirements for standardized DER communication protocols, per IEEE 1547-2018 revision, as it relates to device authentication, key management, and encryption. The state of the art for these security features is also explored, addressing their impact on communication and performance of low-cost single board computers, which are typical of DER devices. In conclusion, a recommendation is provided to adopt a common set of communication requirements, which are intended to achieve interoperability and implement data security over DER network pathways, while ensuring reliable, secure, and real-time information delivery.

42 ENGINEERING↗

New Approaches to Low-Cost Scalable Doping of Interdigitated back Contact Silicon Solar Cells (Final Report)

The goal of this project was to develop novel approaches to patterning of dopants in the rear fingers of interdigitated back contact (IBC) Si solar cells to reduce the cost of manufacturing this high-efficiency-potential cell architecture. The work throughout this project can be divided into four categories: (a) development of dopant patterning technique using laser scribed Si contacts masks that are mechanically aligned with ~10 μm resolution to the underlying Si substrate; (b) measuring dopant spreading profiles in the isolation region between n- and p-type dopant fingers during plasma-enhanced chemical vapor deposition (PECVD) of doped hydrogenated amorphous silicon (a-Si:H) via shadow masks, and dopant desorption and re-adsorption during high-temperature annealing; (c) understanding the role of dopant compensation on the shunt resistance in contaminated isolation regions through analysis of defect-enhanced compensation; and (d) simulation and fabrication of passivated two-sided grid and back-contact solar cells to demonstrate the use of direct dopant patterning in cell fabrication. For the passivated two-sided grid solar cells, masked deposition was used to demonstrate an improvement in the blue response of the cell by creating a shallow front emitter. During development of the masked PECVD patterning process, we measured 3-D dopant profiles using secondary ion mass spectrometry. After deposition, in the masked region, the phosphorus dopant tail was >100 µm at concentrations >10 19 cm -3 while the boron dopant tail was shorter. During high-temperature crystallization of doped a-Si:H films to polycrystalline Si (poly-Si), phosphorus atoms spread by desorbing from the poly-Si surface and re-adsorbing onto intrinsic poly-Si on adjacent wafers that were separated by several millimeters. These contamination mechanisms resulted in a decrease in resistivity from ~10 5 Ω·cm for intrinsic poly-Si to ~10 -1 Ω·cm for contaminated poly-Si. Mitigation strategies for each contamination mechanism were developed to maintain a resistivity of ~10 5 Ω·cm between doped fingers. During fabrication of the 209 cells created during this project, it was found that despite contamination of the IBC gap through the abovementioned mechanisms, high shunt resistances and FF ~75% were still reached. Investigation into this led to the discovery of defect-enhanced compensation which exists within highly defective poly-Si when net doping concentrations reach the value of defect density (~10 18 cm -3 for many poly-Si films). Simulations guided us in the fabrication of IBCs and the cells fabricated were able to meet the year-end goals for BP 2 and 3 of 15% and 17% IBC cell efficiency, as well as the BP 4 goal of a 1% absolute increase in efficiency for PERC-like devices. However, the most efficient cell created during this project of 18.6% fell short of the 21% final project target. While the champion device fell short in V oc and J sc , many devices fabricated were able to reach the necessary goals of ~40 mA/cm 2 , ~700 mV, and ~75% FF required for a 21% device. The results generated from this project were disseminated through 11 conference presentations and proceedings. Presentations included oral talks at 2019 IEEE PVSC, 2019 MRS Fall Meeting, 2020 PVSEC-30 and 2021 IEEE PVSC, as well as poster presentations at 2020 IEEE PVSC and 2021 SiPV. The project resulted in 2 peer reviewed publications – one published in IEEE Journal of Photovoltaics and one in ACS Applied Energy Materials. The information gained in this project will aid in development of improved processes for fabrication of high-efficiency solar cells and other areas of the semiconductor device industry as well. The IBC cells will also pave the way for higher efficiency tandem devices. Through further manufacturing of high-efficiency solar cells, more of the world’s energy demands can be met through renewable sources, helping to stave off the worst effects that may come about from global climate change.

14 SOLAR ENERGY↗

Universal Utility Data Exchange (UUDEX): Information Exchange Models for Solar DER (Rev. 1)

This report describes how the Universal Utility Data Exchange (UUDEX) can encapsulate and exchange information about distributed energy resources (DER) within UUDEX-formatted JSON documents. It proposes to use the existing extensible markup language (XML) information exchange format described in IEEE Std 2030.5, IEEE Standard for Smart Energy Profile Application Protocol but not other information exchange provisions of IEEE 2030.5, rather, relying on equivalent mechanisms in UUDEX. This will allow adoption of the UUDEX exchanges with minimal changes to the structure of the information exchanged and will not require a modification to the UUDEX documentation if IEEE 2030.5 makes changes to the information models.

14 SOLAR ENERGY↗

Universal Utility Data Exchange (UUDEX): Information Exchange Models for Solar DER

This report describes how the Universal Utility Data Exchange (UUDEX) can encapsulate and exchange information about distributed energy resources (DER) within UUDEX-formatted JSON documents. It proposes to use the existing extensible markup language (XML) information exchange format described in IEEE Std 2030.5, IEEE Standard for Smart Energy Profile Application Protocol but not other information exchange provisions of IEEE 2030.5, rather, relying on equivalent mechanisms in UUDEX. This will allow adoption of the UUDEX exchanges with minimal changes to the structure of the information exchanged and will not require a modification to the UUDEX documentation if IEEE 2030.5 makes changes to the information models.

42 ENGINEERING↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

The Design of a Fault-Tolerant COTS-Based Bus Architecture

In this paper, we report our experiences and findings on the design of a fault-tolerant bus architecture comprised of two COTS buses, the IEEE 1394 and the 12C. This fault-tolerant bus is the backbone system bus for the avionics architecture of the X2000 program at the Jet Propulsion Laboratory. COTS buses are attractive because of the availability of low cost commercial products. However, they are not specifically designed for highly reliable applications such as long-life deep-space missions. The X2000 design team has devised a multi-level fault tolerance approach to compensate for this shortcoming of COTS buses. First, the approach enhances the fault tolerance capabilities of the IEEE 1394 and 12 C buses by adding a layer of fault handling hardware and software. Second, algorithms are developed to enable the IEEE 1394 and the 12 C buses assist each other to isolate and recovery from faults. Third, the set of IEEE 1394 and 12 C buses is duplicated to further enhance system reliability. The X2000 design team has paid special attention to guarantee that all fault tolerance provisions will not cause the bus design to deviate from the commercial standard specifications. Otherwise, the economic attractiveness of using COTS will be diminished. The hardware and software design of the X2000 fault-tolerant bus are being implemented and flight hardware will be delivered to the ST4 and Europa Orbiter missions.

Chau, Savio N.↗

Downlink Data Multiplexer

A multiplexer/demultiplexer system has been developed to enable the transmission, over a single channel, of four data streams generated by a variety of sources at different (including variable) bit rates. In the original intended application, replicas of this multiplexer/demultiplexer system would be incorporated into the spacecraft-to-ground communication systems of the space shuttles. The multiplexer of each system would be installed in the spacecraft, where it would acquire and process data from such sources as commercial digital camcorders, video tape recorders, and the spacecraft telemetry system. The demultiplexer of each system would be installed in a ground station. Purely terrestrial systems of similar design could be attractive for use in situations in which there are requirements to transmit multiple streams of high-quality video data and possibly other data over single channels. The figure is a block diagram of the multiplexer as configured to process data received via three fiber-optic channels like those of the International Space Station and one electrical-cable channel that conforms to the Institute of Electrical and Electronic Engineers (IEEE) 1394 standard. (This standard consists of specifications of a high-speed serial data interface, the physical layer of which includes a cable known in the art as "FireWire." An IEEE 1394 interface can also transfer power between the components to which it is connected.) The fiber-optic channels carry packet and/or bit-stream signals that conform to the standards of the Consultative Committee for Space Data Systems (CCSDS). The IEEE 1394 interface accepts an isochronous signal like that from a digital camcorder or a video tape recorder. The processing of the four input data streams to combine them into one output stream is governed by a statistical multiplexing algorithm that features a flow-control capability and makes it possible to utilize the transmission channel with nearly 100-percent efficiency. This algorithm allocates the available bandwidth of the transmission channel to the data streams according to a combination of data rates and preassigned priorities. Incoming data streams that demand too much bandwidth are blocked. Bandwidth not needed for a transmission of a given data stream is allocated to other streams as available. Priority is given to the IEEE 1394 stream. In addition to the four incoming data streams, the multiplexer transmits data on the status of the system. An operator can monitor and control the multiplexer via displays and controls on the multiplexer housing. The output of the multiplexer is connected via a coaxial cable with an impedance of 50 Ohms to an interface circuit compatible with the space-shuttle high-speed digital downlink, which operates at a rate of 48 Mb/s.

Holland, Douglas↗

Application of Multihop Relay for Performance Enhancement of AeroMACS Networks

A new transmission technology, based on IEEE 802.16-2009 (WiMAX), is currently being developed for airport surface communications. A C-band spectrum allocation at 5091 to 5150 MHz has been created by International Telecommunications Union (ITU) to carry this application. The proposed technology, known as AeroMACS, will be used to support fixed and mobile ground to ground applications and services. This article proposes and demonstrates that IEEE 802.16j-amendment-based WiMAX is most feasible for AeroMACS applications. This amendment introduces multihop relay as an optional deployment that may be used to provide additional coverage and/or enhance the capacity of the network. Particular airport surface radio coverage situations for which IEEE 802.16-2009-WiMAX provides resolutions that are inefficient, costly, or excessively power consuming are discussed. In all these cases, it is argued that 16j technology offers a much better alternative. A major concern about deployment of AeroMACS is interference to co-allocated applications such as the Mobile Satellite Service (MSS) feeder link. Our initial simulation results suggest that no additional interference to MSS feeder link is caused by deployment of IEEE 802.16j-based AeroMACS.

Kamali, Behnam↗

Application of Multihop Relay for Performance Enhancement of AeroMACS Networks

A new transmission technology, based on IEEE 802.16-2009 (WiMAX), is currently being developed for airport surface communications. A C-band spectrum allocation at 5091-5150 MHz has been created by ITU to carry this application. The proposed technology, known as AeroMACS, will be used to support fixed and mobile ground to ground applications and services. This article proposes and demonstrates that IEEE 802.16j-amendment-based WiMAX is most feasible for AeroMACS applications. This amendment introduces multihop relay as an optional deployment that may be used to provide additional coverage and/or enhance the capacity of the network. Particular airport surface radio coverage situations for which IEEE 802.16-2009-WiMAX provides resolutions that are inefficient, costly, or excessively power consuming are discussed. In all these cases, it is argued that 16j technology offers a much better alternative. A major concern about deployment of AeroMACS is interference to co-allocated applications such as the Mobile Satellite Service (MSS) feeder link. Our initial simulation results suggest that no additional interference to MSS feeder link is caused by deployment of IEEE 802.16j-based AeroMACS.

Kamali, Behnam↗

Integrated Mission Simulation (IMSim): Multiphase Initialization Design with Late Joiners, Rejoiners and Federation Save & Restore

This document describes the design of the Integrated Mission Simulation (IMSim) federate multiphase initialization process. The main goal of multiphase initialization is to allow for data interdependencies during the federate initialization process. IMSim uses the High Level Architecture (HLA) IEEE 1516 [1] to provide the communication and coordination between the distributed parts of the simulation. They are implemented using the Runtime Infrastructure (RTI) from Pitch Technologies AB. This document assumes a basic understanding of IEEE 1516 HLA, and C++ programming. In addition, there are several subtle points in working with IEEE 1516 and the Pitch RTI that need to be understood, which are covered in Appendix A. Please note the C++ code samples shown in this document are for the IEEE 1516-2000 standard.

Dexter, Daniel E.↗

On Proper Selection of Multihop Relays for Future Enhancement of AeroMACS Networks

As the Aeronautical Mobile Airport Communications System (AeroMACS) has evolved from a technology concept to a deployed communications network over major US airports, it is now time to contemplate whether the existing capacity of AeroMACS is sufficient to meet the demands set forth by all fixed and mobile applications over the airport surface given the AeroMACS constraints regarding bandwidth and transmit power. The underlying idea in this article is to present IEEE 802.16j-based WiMAX as a technology that can address future capacity enhancements and therefore is most feasible for AeroMACS applications. The principal argument in favor IEEE 802.16j technology is the flexible and cost effective extension of radio coverage that is afforded by relay fortified networks, with virtually no increase in the power requirements and virtually no rise in interference levels to co-allocated applications. The IEEE 802.16j-based multihop relay systems are briefly described. The focus is on key features of this technology, frame structure, and its architecture. Next, AeroMACS is described as a WiMAX-based wireless network. The two major relay modes supported by IEEE 802.16j amendment, i.e., transparent and non-transparent are described. The benefits of employing multihop relays are listed. Some key challenges related to incorporating relays into AeroMACS networks are discussed. The selection of relay type in a broadband wireless network affects a number of network parameters such as latency, signal overhead, PHY (Scalable Physical Layer) and MAC (Media Access Layer) layer protocols, consequently it can alter key network quantities of throughput and QoS (Quality of Service).

aircraft communications↗

One NASA PEM qualification standard : comparison of JPL and GSFC standards

Although use of Plastic Encapsulated Microelectronics (PEMs) in space applications is discouraged, their use is mandatory for selected applications involving the need for advanced technology and small packages. Various space systems designers and manufacturers have developed methods to qualify and screen PEMs. In general, each procedure is different. The purpose of this fiscal year’s investigation is to initiate a process to coordinate the efforts at various NASA centers to eventually develop a One NASA method. Part of this activity includes sharing of test data and PEM qualification methodologies. Various experts in the NASA community were identified and contacted to support this effort. We were successful in finding such experts at GSFC, APL and the Constellation office (Orion and Ares). All these experts provided typical qualification program plans. Since funding was severely restricted, it was decided to concentrate on coordination activity with GSFC. GSFC is planning a new version of IEEE-INST-002 section applying to PEMs. The GSFC expert (Dr. Alexander Teverovsky) provided a detailed assessment of the differences between the planned new version of IEEE-INST-002 and the JPL-D-19426 (JPL guideline) as well as a summary rationale for the decisions within the IEEE-INST-002. It should be noted that GSFC’s assessment of IEEE-INST-002 in the area of PEMs is not finalized. JPL is also considering changes in PEM qualification methodologies based on test data from recent qualification testing for their newer Projects (MSL, Grail, Juno). A spreadsheet delineating the differences between the JPL standard and the GSFC standard is presented.

Cooper, Mark↗

ECAR-7517 Rev 1 MARVEL I&C Failure Modes and Effects Analysis

The purpose of this document is to perform a single-failure analysis through the use of a Failure Modes and Effects Analysis (FMEA) for the Safety Related components of the MARVEL Instrumentation and Control (I&C) System. The intent is that this document will meet the requirements for a single-failure analysis described in IEEE-379, “IEEE Standard for Application of the Single-Failure Criterion to Nuclear Power Generating Station Safety Systems”, to verify that this design does indeed meet the single failure criterion. Principles of IEEE-352, “IEEE Guide for General Principles of Reliability Analysis of Nuclear Power Generating Station Safety Systems” are followed to ensure the analysis is consistent with industry standards.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗