Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HgCdTe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Sensitivity limits of an infrared heterodyne spectrometer for astrophysical applications

A discussion and an evaluation of the degradation in sensitivity are given for a heterodyne spectrometer employing a HgCdTe photodiode mixer and tunable diode lasers. The minimum detectable source brightness is considered as a function of the mixer parameters, transmission coefficient of the beam splitter, and local oscillator emission powers. The degradation in the minimum detectable line source brightness that results from the bandwidth being a fraction of the line width is evaluated and plotted as a function of the wavelength and bandwidth for various temperature to mass ratios. It is shown that the minimum achievable degradation in the sensitivity of a practical astronomical heterodyne spectrometer is about 30. Estimates of SNRs with which IR line emission from astronomical sources of interest may be detected are given.

Abbas, M. M.↗

Multilayered (Hg,Cd)Te infrared detector

Multilayered mercury-cadmium telluride photoconductive detectors were developed which are capable of providing individual coverage of three separate spectral wavelength bands without the use of beam splitters. The multilayered "three-color" detector on a single dewar takes the place of three separate detector/filter/dewar units and enables simpler and more reliable mechanical and optical designs for multispectral scanners and radiometers. Wavelength channel design goals (in micrometers) were: 10.1 to 11.0, 11.0 to 12.0, and 13.0. Detectivity for all channels was 1 x 10 to the 10th power cm-Hz 1/2/Watt. A problem occurred in finding an epoxy layer which had good infrared transmission properties and which also was chemically and mechanically compatible with HgCdTe processing techniques. Data on 6 candidate bonding materials are surveyed and discussed.

Rae, W. G.↗

Effects of systemic and non-systemic stresses on the thermal characteristics of corn

Experiments were conducted on corn plants using a calibrated spectroradiometer under field conditions in the indium antimonide channel (InSb, 2.8 to 5.6 mm) and the mercury cadmium telluride channel (HgCdTe, 7 to 14 mm). A ground cover experiment, an experiment on nonsystemic corn plants, and an experiment on systemic-stressed corn plants were included. The average spectral radiance temperature of corn plant populations was found (1) to be statistically significantly different for four healthy corn plant populations, (2) to increase with increased blight severity, and (3) to be statistically significantly different for varying rates of nitrogen applications.

Kumar, R.↗

Stratospheric ozone measurement with an infrared heterodyne spectrometer

Measurements of a stratospheric ozone concentration profile are made by detecting infrared absorption lines with a heterodyne spectrometer. The infrared spectrometer is based on a line-by-line tunable CO2 lasers, a liquid-nitrogen cooled HgCdTe photomixer, and a 64-channel spectral line receiver. The infrared radiation from the source is mixed with local-oscillator radiation. The difference frequency signal in a bandwidth above and below the local-oscillator frequency is detected. The intensity in each sideband is found by subtracting sideband contributions. It is found that absolute total column density is 0.32 plus or minus 0.02 cm-atm with a peak mixing ratio at about 24 km. The (7,1,6)-(7,1,7) O3 line center frequency is identified as 1043.1772/cm. Future work will involve a number of ozone absorption lines and measurements of diurnal variation. Completely resolved stratospheric lines may be inverted to yield concentration profiles of trace constituents and stratospheric gases.

Abbas, M. M.↗

Thermal analysis of Bridgman-Stockbarger growth

A thermal analysis of a cylindrical HgCdTe sample in a Bridgman-Stockbarger crystal growth configuration was conducted with emphasis on the thermal profile, interface shape and position, and the thermal gradients at the liquid-solid interface. Alloys of HgTe and CdTe with compositions approximating 20 percent CdTe, 80 percent HgTe were used. This composition results in a bandgap suited for the detection of 10.6 micron CO2 radiation. The sensitivity of the sample thermal characteristics to important growth parameters, such as thermal diffusivities, thermal conductivities, furnace temperature profile, ampoule dimensions, and growth velocity was assessed. Numerical techniques and associated computational models necessary to analyze the heat transfer process within the sample and the Bridgman-Stockbarger boundary conditions were developed. This thermal analysis mode was programmed in FORTRAN V, and is currently operational on the MSFC Univac 1100 system.

Knopf, F. W.↗

The TIROS-N high resolution infrared radiation sounder

The high-resolution infrared radiation sounder (HIRS/2) was developed and flown on the Television and Infrared Observation Satellite, N Series (TIROS-N) as one means of obtaining atmospheric vertical profile information. The HIRS/2 receives visible and infrared spectrum radiation through a single telescope and selects 20 narrow spectral channels by means of a rotating filter wheel. A passive radiant cooler provides an operating temperature of 106.7K for the HgCdTe and InSb detectors while the visible detector operates at instrument frame temperature. Low noise amplifiers and digital processing provide 13 bit data for spacecraft data multiplexing and transmission. The qualities of system performance that determine sounding capability are the dynamic range of data collection, the noise equivalent radiance of the system, the registration of the air columns sampled in each channel, and the ability to upgrade the calibration of the instrument to maintain the performance standard throughout life. The basic performance of the instrument in test is described. Early orbital information from the TIROS-N launched on October 13, 1978 are given and some observations on system quality are made.

Koenig, E. W.↗

A 10 micron heterodyne receiver for ultra high resolution astronomical spectroscopy

An improved CO2 laser heterodyne spectrometer is examined. The present system uses reflective optics to eliminate refocusing at different wavelengths, and the local oscillator is a line-center-stabilized isotopic CO2 laser. A tunable diffraction grating makes possible easy and rapid selection of over 50 transitions per isotope of CO2. The IF (0 to 1.6 GHz) from the HgCdTe photomizer is analyzed by a 128-channel filter bank, consisting of 64 tunable 5-MHz filters and 64 fixed 25-MHz RF filters. These filters provide resolving powers of about 1,000,000 to 10,000,000 and velocity resolution of 50 to 250 m/sec; their output is synchronously detected, integrated, multiplexed and stored in a buffer memory for the desired integration period. Kitt Peak observations show the wide spectral coverage, wide mixer and electronics bandwidth, and high sensitivity of the system.

Buhl, D.↗

Satellite observations of upper atmosphere O3 and HNO3 from the Limb Infrared Monitor of the Stratosphere /LIMS/ experiment on Nimbus 7

The Limb Infrared Monitor of the Stratosphere (LIMS) experiment, launched on-board the Nimbus satellite, was designed to measure both day and night limb radiance which is used to infer upper atmosphere temperature profiles and chemical compound concentrations important in the study of ozone chemistry. The LIMS instrument is a six channel, limb scanning, thermal radiometer which uses HgCdTe detectors, cooled to approximately 64 K. Measurements include ozone, water vapor, nitrogen dioxide, and nitric acid. The ozone and nitric acid channels are centered at approximately 9.6 microns and 11.3 microns, respectively. Results from the channels are described with an emphasis on data validation. The O3 and HNO3 channels have demonstrated high measurement precision.

Russell, J. M., III↗

Performance of the HIRS/2 instrument on TIROS-N

The High Resolution Infrared Radiation Sounder (HIRS/2) was developed and flown on the TIROS-N satellite as one means of obtaining atmospheric vertical profile information. The HIRS/2 receives visible and infrared spectrum radiation through a single telescope and selects 20 narrow radiation channels by means of a rotating filter wheel. A passive radiant cooler provides an operating temperature of 106.7 K for the HgCdTe and InSb detectors while the visible detector operates at instrument frame temperature. Low noise amplifiers and digital processing provide 13 bit data for spacecraft data multiplexing and transmission. The qualities of system performance that determine sounding capability are the dynamic range of data collection, the noise equivalent radiance of the system, the registration of the air columns sampled in each channel and the ability to upgrade the calibration of the instrument to maintain the performance standard throughout life. The basic features, operating characteristics and performance of the instrument in test are described. Early orbital information from the TIROS-N launched on October 13, 1978 is given and some observations on system quality are made.

Koenig, E. W.↗

Space processing of electronic materials

The relative values of thermal conductivity of solid and liquid HgCdTe are critically important in the design configuration of the furnaces used for Bridgman crystal growth. The thermal diffusivity of the material is closely linked to the conductivity by the defining relation D = k/rho c, where D is the diffusivity, K is the thermal conductivity, rho is the density, and c is the specific heat. The use of transient and periodic heating approaches to measure the diffusivity are explored. A system for securing and extracting heat from silica or glass tubes under high C vacuum conditions is described.

Workman, G. L.↗

Heat flow control and segregation in directional solidification

Optimization of the vertical Bridgman technique for growth of electronic materials in single crystal form was investigated. The limitations of the crystal growth configuration were experimentally determined and heat transfer related deficiencies identified. Design of an alternate system was based on the use of heat pipes separated by a gradient region. Heat transfer analyses based on one and two dimensional models indicated the necessity of a flexible gradient zone configuration. Directional melting of binary systems as encountered during seeding in melt growth was analysed for concurrent compositional changes at the crystal-metal interface, and the theoretical treatment numerically applied to HgCdTe and Ga doped germanium. A theoretical and experimental study of the thermal effects associated with current flow was conducted. It was found that experimental measurements of dc induced growth during crystal pulling can be used for the precise determination of the Peltier coefficient.

Witt, A. F.↗

Image science team

A substantial technology base of solid state pushbroom sensors exists and is in the process of further evolution at both GSFC and JPL. Technologies being developed relate to short wave infrared (SWIR) detector arrays; HgCdTe hybrid detector arrays; InSb linear and area arrays; passive coolers; spectral beam splitters; the deposition of spectral filters on detector arrays; and the functional design of the shuttle/space platform imaging spectrometer (SIS) system. Spatial and spectral characteristics of field, aircraft and space multispectral sensors are summaried. The status, field of view, and resolution of foreign land observing systems are included.

Ando, K.↗

JPL airborne instruments activities

Two instruments intended for flight aboard aircraft for research in advanced remote sensing of the earth are under development: the airborne imaging spectrometer (AIS) and the airborne visible-infrared imaging spectrometer (AVIRIS). The AIS utilizes a 32 x 32 element HgCdTe CCD array to gather 10nm spectral data, initially in the 1.2 to 2.4 micron range, with 32 pixels of cross-track spatial data. The instrument acquires 128 channels of spectral data by using a grating spectrometer whose grating is stepped through four positions during a fraction of an IFOV time on the ground. With an IFOV of 2 mrad, the GIFOV at the design altitude of 3 km is 6m. The instrument has several on-board processing capabilities including ax+b corrections for detector calibration, cross-track and down-track pixel summing, spectral band summing, and variable integration time to allow flight at various altitudes and velocities. The AVIRIS uses a proven scanning mechanism to acquire the spatial data in a whisk broom mode. The spectral coverage is from 0.35 to 2.5 microns at bandwidths ranging from 10 to 20 nm.

Vane, G.↗

High-temperature, high-pressure optical cells

For measuring the thermal diffusivity of HgCdTe melts by the laser-pulse method, an infrared transparent cell with flat windows of sufficient strength to withstand the high-vapor pressure of mercury had to be developed. Since mercury telluride expands on freezing, certain difficulties arose in returning the cell to room temperature without cracking it. T08 commercial fused silica is used in the construction of the cell, and the cells are transparent for wavelengths from about 3.5 microns in the infrared to 260 nm in the ultraviolet. The construction procedure for the required cells has been laborious. However, the obtained cell has routinely withstood internal pressures in excess of 60 atm at 900 C. Attention is given to the design of the windows, aspects of cell construction, and questions of loading.

Holland, L. R.↗

IR detectors - Heterodyne and direct

Recent developments in the area of wide-bandwidth infrared detectors, both for direct and heterodyne detection, are reviewed with emphasis on the differences and tradeoffs between photodiodes and photoconductors. In the direct-detection mode, where amplifier noise is an important consideration, the state-of-the-art detection noise equivalent power is approximated by 500 (B/10 MHz) pW. At short wavelengths (less than 1.7 micron), avalanche photodiodes offer superior performance, with a detection noise equivalent power of about 50 (B/10 MHz) pW. In heterodyne operation, near-ideal sensitivities of about 0.3 (B/10 MHz) pW have been achieved with 77K photodiodes. At 10 microns, HgCdTe photoconductors offer very good heterodyne performance at elevated temperatures: 2 (B/10 MHz) pW at 195 K and potentially 3 (B/10 MHz) pW at 250 K.

Spears, D. L.↗

Mineralogic information from a new airborne thermal infrared multispectral scanner

The thermal IR multispectral scanner (TIMS) has been developed for airborne geologic surveys. The resststrahlen band between 8-11 microns is exhibited by interatomic stretching vibrations of Si and oxygen bound up in the crystal lattice of silicate rocks. The crystal structure of the component minerals influence the depth and position of the detected band. The TIMS has six channels, an 80 deg field of view, and a sensitivity sufficient to detect a noise equivalent change in spectral emissivity of 0.002-0.006. The six bands measured are 8.2-8.6, 8.6-9.0, 9.4-10.2, 10.2-11.2, and 11.2-12.2 microns, using HgCdTe detectors. The data are analyzed with respect to emissivity variations as a function of wavelength, using the component transformation technique called a decorrelation stretch, with spectral differences being displayed as different colors. Sample scenes from Death Valley and the Nevada Cuprite mining district are compared with visible and near-IR color composites of the same areas, revealing the superior distinctions that are available with the TIMS.

Kahle, A. B.↗

Compositional Segregation in Unidirectionally Solidified Solid Solution Crystals

A computer program was developed to model compositional segregation in unidrectionally solidified solid-solution-semiconducting crystals. The program takes into account the variations of the interface segregation constant and solidification rate with composition. Calculations are performed for the HgCdTe solid solution system that is compared with experimental data.

Wang, J. C.↗

High-Temperature, High-Pressure Optical Cells

Optical cell constructed for measurement of thermal diffusivity of HgCdTe semiconductor by laser pulses. Container allows radiation from laser to enter one side of alloy sample, while allowing lower-energy infrared radiation to leave opposite side of sample so temperature rise read by sensor. Composed entirely of fused silica, cell includes two optical windows joined by tube. Cell withstands 1,000 degrees C cell-operating temperature and contains molten alloy at its 100-atmosphere vapor pressure. Finally, allows alloy to solidify without bursting even though alloy expands on cooling.

Harris, R. P.↗