Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HfIr”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

NSUF BOILER Pre-Irradiation Characterization and High Flux Isotope Reactor Experiment Design

Alumina-forming austenitic (AFA) stainless steels have emerged as a candidate alloy because of their high-temperature strength, formability, cost, and compatibility with primary coolants for lead-cooled fast reactors (LFRs). This class of steels has exceptional high-temperature oxidation performance; however, a high concentration of Ni is required to stabilize the austenite phase and to provide sufficient creep strength. AFA stainless steels are also susceptible to liquid metal embrittlement (LME). Additionally, under neutron irradiation, Ni will enrich at grain boundaries due to radiation-induced segregation (RIS). Nickel RIS can increase the LME under these coupled effects. Oak Ridge National Laboratory (ORNL) and the NSUF program have leveraged its High Flux Isotope Reactor (HFIR) and experience with complex irradiation experiments to design experiment capsules that test the aforementioned coupled effects. These capsules are designed for insertion in the central flux trap, the highest flux region, of HFIR. The experiment capsules will be filled with Pb, designed to passively melt from the gamma heating in HFIR. The specimens were fabricated into miniature tensile specimens from two different alloys, GA05-25Ni and GA05-20Ni, varying Ni concentrations. The experiment capsules are designed to achieve target temperatures of 400 °C and 650 °C with accumulated dosage of 3 dpa. This report documents the specimen alloy characterization, experimental design, and expected performance of the capsules.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Oak Ridge National Laboratory Neutron Spin Echo Beamline on NB-2

Neutron Spin Echo (NSE) spectroscopy uniquely measures the Q-dependence of slow relaxation dynamics, and having such a machine at HFIR will advance polarized neutron spectroscopy and promote the study of biophysical and energy materials using neutrons. The 2018 Instrument Advisory Board (IAB) advises Neutron Sciences Directorate, ORNL to upgrade the cold neutron delivery system at HFIR, addressing geometrical challenges in neutron transfer from the bright cold source. This is being optimized now: the entrance to the guide system is moving closer to the source, and more guides are being added. However, there are still significant challenges to making the cold flux at the sample world-class. With the proposed guide system, NB-2 can deliver more than 10 6 polarized neutrons per cm 2 /sec below 8Å, and probably 10Å with further optimization. With no potential for running user experiments with neutrons longer than 15Å, the utility of such a machine for biological studies is limited. However, there is a large demand for this class of spectrometer in materials science, chemical engineering, and nanotechnology. Workshops held over the past decade and the three-source vision have highlighted the community's need for a low-angle, high-energy resolution spectrometer at HFIR. A detailed design study of this spectrometer is needed, focusing on optimizing the neutron delivery system for SANS-type studies. This neutron spectrometer would complement studies already performed on both SNSNSE and BASIS by overlapping and extend the dynamic range accessible, while acknowledging the proposed machine, EXPANSE, at the Second Target Station. Two technologies currently exist for such a spectrometer: traditional DC solenoids like those on BL-15 at SNS and IN15 at the ILL, and RF-flipper-based machines similar to RESEDA at FRMII. Either instrument would satisfy the scientific justification. However, there are strong business and scientific cases to utilize the thermal flux, the resonant expertise developed at ORNL, and the potential to utilize an entangled beam of neutrons to probe quantum matter by adopting the neutron resonant spin-echo configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of MiniFuel Subcapsule Design Recommendations on Previous Experiments

MiniFuel describes the class of separate effects nuclear fuels irradiation experiments that have been conducted in the High Flux Isotope Reactor (HFIR) since 2018. These experiments comprise a stack of six fuel-bearing subcapsules contained in a stainless steel target housing that is in contact with HFIR coolant on its exterior. All MiniFuel targets have a near-standardized architecture, and the primary design variables that change between experiments are the radial gap size between the subcapsule and housing and the target fill gas composition. Finite element heat transfer models are used to determine the optimum gas composition and gap sizes, and recent studies were performed to identify model parameters that contribute the most uncertainty to fuel specimen temperature predictions. That work, which is referenced herein, also recommended a set of design modifications to the subcapsule internal architecture and assembly process. These modifications are intended to reduce fuel temperature uncertainty in future experiments. In this report, the subcapsule design modifications were retroactively applied to a previously conducted MiniFuel experiment to determine how these changes affect the established safety and performance envelope of the experimental capability. These effects were determined in two steps. First, the modifications were applied to the subcapsule design without any other changes to determine their isolated effect on the predicted fuel specimen temperatures. This portion of the analysis showed that fuel temperatures were modestly reduced because the implemented changes improved heat transfer efficacy. Next, traditional MiniFuel design activities (i.e., sizing the gas gaps and determining the fill gas composition) were reperformed, and they confirmed that the original desired fuel temperatures could be achieved while remaining within established safety limits. Therefore, this report demonstrates improved performance resulting from the subcapsule modifications, which mitigate uncertainty while meeting the objectives of past experiments. An additional benefit of the design changes is reduced sensitivity of the fuel temperature to the evolving flux spectrum in HFIR, leading to more stable temperatures and enhanced utility of MiniFuel as a separate effects irradiation platform.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Custom Robotic System for Inspecting HEPA Filters in the Payload Changeout Room at the NASA Kennedy Space Center

In this paper, the prime objective is to describe a custom 4-dof (degree-of-freedom) robotic arm capable of autonomously or telerobotically performing systematic HEPA filter inspection and certification in the Shuttle Launch Pad Payload Changeout Rooms (PCR's) on pads A and B at the Kennedy Space Center, Florida. This HEPA filter inspection robot (HFIR) has been designed to be easily deployable and is equipped with the necessary sensory devices, control hardware, software and man-machine interfaces needed to implement HEPA filter inspection reliably and efficiently without damaging the filters or colliding with existing PCR structures or filters. The main purpose of the HFIR is to implement an automated positioning system to move special inspection sensors in pre-defined or manual patterns for the purpose of verifying filter integrity and efficiency. This will ultimately relieve NASA Payload Operations from significant problems associated with time, cost and personnel safety, impacts realized during non-automated PCR HFIR filter certification.

Spencer, James E., Jr.↗

Development of an In Situ Fission Gas Release Instrument for Fuel Sample Irradiations in the High Flux Isotope Reactor

Experimental measurement of gaseous fission product release with respect to temperature and burnup is a critical aspect of understanding nuclear fuel performance, validating predictive models, and qualifying new fuels. To measure this phenomenon in real-time, Oak Ridge National Laboratory has developed an instrument for measuring in situ fission gas release from small-scale fuel samples irradiated in the High Flux Isotope Reactor (HFIR). The instrument uses a continuous flow of Heover the fuel samples to sweep gaseous fission products from a sealed capsule in the HFIR Be reflector to an instrument station adjacent to the reactor. The instrument station houses two high-purity germanium (HPGe) detectors that measure decay gamma rays from fission products passing through a room temperature dwell chamber placed over the detector crystal. The sealed capsules in the reactor are designed to modulate fuel sample temperatures between 700 and 1,100°C by changing the Ar/He gas mixture surrounding the capsules during irradiation. N-type thermocouples are incorporated into the capsule housing to record real-time fuel temperatures. The capsules are heated primarily by prompt gamma rays emitted from the HFIR core with minimal heat contributions from fission in the fuel samples to minimize temperature gradients in the specimens for separate-effects characterization of the material. This paper describes modeling of time-dependent nuclear heating and fission product formation in fuel samples, thermal characteristics of the in-core capsules, and expected gaseous fission product gamma spectra at the HPGe instrument station.

Mulligan, Padhraic L [ORNL] (ORCID:000000025826540↗

Fast neutron irradiation capability in existing thermal test reactors

In today’s nuclear industry, momentum towards the design, licensing, and construction of advanced nuclear demonstration plants, including fast reactors, is at a remarkably high level. However, there are currently no dedicated fast spectrum irradiation test facilities in the United States to support the development of fast spectrum technologies. As a result, a unique situation is developing where most of these plants will likely be designed by leveraging historic nuclear material technologies, but where the further optimization and advancement is impeded by the lack of fast neutron irradiation test facilities. While these circumstances present a challenge, there are some near-term opportunities that, if seized, can still help develop advanced fast reactor materials to a meaningful level of readiness to support future commercial fast reactors. Here, in this paper, we assess the feasibility of using thermal neutron filtering materials in existing experiment positions in the Advanced Test Reactor (ATR) at Idaho National Laboratory and the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory to simulate fast reactor test environments for nonfuel test specimens. Items investigated include the incident neutron flux (both fast and thermal), the total neutron fluence and cumulative atom displacements, helium production rate due to thermal neutron capture in nickel, and the potential impact that the thermal neutron filter material has on the cycle length of a given reactor. It is concluded that while HFIR provides the highest fast flux of all the options investigated, it is limited in the amount of thermal neutron filtering material that can be introduced into an experiment position without significantly affecting the operation of the reactor. Irradiation in Outboard-A positions in the ATR was found to be the most realistic near-term experiment avenue due to having ample space for several capsules in a moderately fast flux.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensitivity analysis of thermal contact conductance modeling to inform MiniFuel irradiation capsule designs

The MiniFuel irradiation platform has been developed by Oak Ridge National Laboratory as a flexible, high-throughput separate effects testing capability within the High Flux Isotope Reactor (HFIR). Finite element thermal models are relied upon to design MiniFuel experiments to achieve a specific time-averaged irradiation temperature for experimental objectives. A previous study identified that uncertainty in the component heat generation rates and thermal contact conductance (TCC) model are the most significant contributors to predicted fuel temperature variance. To address both sources of uncertainty, this work performs sensitivity analysis on the TCC model to identify high-impact, high-uncertainty parameters that contribute to fuel temperature variance. The TCC model is analyzed in increasing detail, first using a standalone Python code, then again after coupling Python to the BISON fuel performance code. Furthermore, the parameters with the largest contributions to fuel temperature variance which can be reduced through design changes are identified as the initial subcapsule gas pressure, contact pressure between the fuel and dish, and the effective surface roughness of the interface. A set of design recommendations for future capsule designs has been established and applied to reduce the previously quantified average fuel temperature uncertainty ranges of ± 40 °C in the HFIR vertical experiment facilities (VXF) and ± 80 °C in the removable beryllium (RB) reflector to approximately ± 32 °C and ± 53 °C, respectively. This equates to a 21 % and 33 % reduction in the uncertainty range of the average fuel temperature for VXF and RB, respectively.

BISON↗

Deployment of the HFIRCON transport and depletion tool for plutonium-238 production studies

Irradiation of {sup 237}Np-bearing targets in Oak Ridge National Laboratory's (ORNL) High Flux Isotope Reactor (HFIR) results in the efficient production of {sup 238}Pu, which, in the form of heat source PuO{sub 2}, is used as a reliable power source for deep-space and planetary NASA missions. A technology demonstration subproject was initiated at ORNL in 2011 to develop and implement the technology required to establish a {sup 238}Pu supply chain. A systematic progression of NpO{sub 2}/Al cermet (20 vol.% NpO{sub 2}) activities to date has successfully demonstrated target fabrication, irradiation, and chemical recovery processes. Recent program tasks have included the development of the HFIRCON transport and depletion tool for efficient reactor physics analyses and the evaluation of increased NpO{sub 2} loadings (i.e., beyond 20 vol.%) and NpN-based targets. This paper documents the deployment of the HFIRCON code to assess various Np concentrations in NpO{sub 2}- and NpN-based targets in HFIR's inner small vertical experiment facilities. Results indicate that {sup 238}Pu production and quality can be enhanced with increased Np loadings; however, target conversion rates are reduced. The results recorded in this paper, thermal and material balance evaluations, and testing requirement planning will be used to determine whether increased NpO{sub 2} loadings or NpN-based targets will be further considered. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Co-Disposal Waste Package Loading Options for DOE SNF and HLW - 20331

The U.S. Department of Energy (DOE) is responsible for managing spent nuclear fuel (SNF) that is currently in, or will in the future come into, its possession. DOE must continue to safely store that SNF, transport it to an interim storage site or a repository, and dispose of it. These fuels come from a wide range of reactor types with various cladding materials and enrichments. Many of these reactors, now decommissioned, had unique design features, such as core configuration, fuel element and assembly geometry, moderator and coolant materials, operational characteristics, and neutron spatial and spectral properties, resulting in a large diversity of reactor and fuel designs. Because of the wide variety and conditions of SNF, a robust DOE Standard Canister was proposed that would confine radionuclides and preclude moderator. The DOE Standard Canister had four variations: 3.05-meter (10-foot) or 4.57-meter (15-foot) length, and 45.7-cm (18-inch) or 61.0-cm (24-inch) diameter. For ultimate disposal in the Yucca Mountain Repository, these canisters were to be grouped with 61.0-cm (24-inch) diameter high level waste (HLW) canisters in a 2.13-meter (84-inch) diameter co-disposal waste package. The smaller 45.7-cm (18-inch) diameter DOE Standard Canister could be placed in the middle of five HLW canisters. The larger 61.0-cm (24-inch) diameter DOE Standard Canister would take the place of one of the five HLW canisters on the outer ring in the co-disposal waste package. No DOE Standard Canisters have been loaded. A preliminary evaluation has estimated the number of elements of a fuel type that can fit into the different sizes of the DOE Standard Canister, but no definitive loading configuration has been selected. Changing the loading configuration could impact the number of loadable DOE Standard Canisters and the number of co-disposal waste packages needed for eventual disposition. This paper conveys the ranges of DOE Standard Canisters and HLW canisters that may be produced under certain conditions. It also examines the differences in the estimated number of co-disposal waste packages produced for eventual disposal when using different loading strategies in the DOE Standard Canister for Advanced Test Reactor (ATR), Peach Bottom, and High Flux Isotope Reactor (HFIR) SNF. Changing the loading configurations of ATR, Peach Bottom, and HFIR SNF slightly impacted the number of co-disposal waste packages that may be needed for ultimate disposal. The change in loading configuration was more impactful when a different canister was used, as opposed to varying the number of elements that could fit inside the same size canister. In one case, a reduction of co-disposal waste packages could be achieved by allowing mixing of short HLW canisters with long DOE Standard Canisters. The main conclusion from this analysis is that the ratio between HLW canisters and DOE Standard Canisters will drive the total number of co-disposal waste packages. If too many HLW canisters (i.e., more than five times the number of 18-inch DOE standard canisters) or DOE Standard Canisters are produced, some co-disposal waste packages may not have all positions filled. A co-disposal waste package may be filled with all HLW with no DOE Standard Canister, or a co-disposal waste package could be filled with a single DOE Standard Canister. A ratio that does not closely align to optimum could allow for the design of waste packages that hold just HLW canisters or just DOE SNF canisters. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding the effect of specimen size on the properties of fine-grain isotropic nuclear graphite for irradiation studies: Mechanical properties

Programs at Oak Ridge National Laboratory are investigating the effects of neutron irradiation in the High Flux Isotope Reactor (HFIR) on properties of fine-grain isotropic nuclear graphites. Specimens were irradiated in the HFIR flux trap, which requires using specimens that are smaller than the sizes recommended by ASTM standards. Here, this work has investigated whether subsized specimens can be used to reliably predict strength behavior. The results show that (1) tensile strength was loosely coupled to specimen volume, (2) the compression specimens had a slightly higher strength for larger volumes, (3) the uniaxial flexural strength was nearly independent of specimen effective area for one orientation whereas the other orientation showed a slight strength–size scaling Weibull behavior, and (4) equibiaxial flexural strength followed traditional strength–size scaling Weibull behavior. These results suggest that fine-grain graphite is more similar to ceramics than to medium- and large-grained graphite with respect to both the strength-limiting flaws (Griffith theory) and the effect of machining on the strength behavior. This work shows that using specimens that are smaller than ASTM recommendations are suitable for investigating the strength changes caused by neutron irradiation because the primary interest is the relative change in the strength distribution parameters rather than their absolute values.

36 MATERIALS SCIENCE↗

Understanding the effect of specimen size on the properties of fine-grain isotropic nuclear graphite for irradiation studies: Physical, electrical, thermal properties

Programs at Oak Ridge National Laboratory are investigating the effects of neutron irradiation in the High Flux Isotope Reactor (HFIR) on properties of fine-grain nuclear graphites. Specimens were irradiated in the HFIR flux trap, which required using specimens that are smaller than the sizes recommended by ASTM standards. Here, this work has investigated whether subsized specimens can be used to reliably determine the measured physical (density, elastic moduli, and electrical resistivity) and thermal properties (coefficient of thermal conductivity and thermal conductivity). The results show the specimen sizes in this investigation had a minimal influence on any of the measured properties. Even for the properties where size influenced the measured value (density and thermal conductivity), an explanation is provided, and the consequences can be accounted for in post-irradiation results. This work demonstrated that using subsized specimens for physical and thermal property measurements is suitable when necessary for fine-grain isotropic graphite.

36 MATERIALS SCIENCE↗

Irradiation creep measurement and microstructural analysis of chromium nitride–coated zirconium alloy using pressurized tubes

Environmental barrier coatings for Zr-based materials are currently under development to reduce oxidation and embrittlement in light-water reactors. Chromium nitride is one such candidate for this application, particularly as accident-tolerant fuel cladding. However, quantifying the impact of coatings on the irradiation-induced creep of zircaloy (Zry) is critical as this mechanism often exceeds thermal creep rates under light-water reactor operating conditions and can be a limiting design characteristic. Additionally, examining irradiation effects in the microstructure at the coating interface is key to understanding the compatibility of the material system. Here, to accelerate the experimental measurement of irradiation creep and microstructure evolution in CrN-Zry, compact, pressurized creep tubes were fabricated and irradiated in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Miniature, thin-walled rodlets fabricated from annealed Zr-Sn barstock were coated with CrN using physical vapor deposition (PVD) to nominal thicknesses of 4 and 8 μm. Coated and uncoated rodlet specimens were internally pressurized and welded, generating nominal circumferential hoop stresses of 0, 90, or 180 MPa under 300°C irradiation conditions. Twelve specimens were measured diametrically prior to irradiation using a low-cost, automated, contactless laser profilometer developed for this work. Specimens were irradiated in sealed capsules for one 25-day HFIR cycle, accumulating approximately 1.8 $\times$ 10 21 n/cm 2 fast fluence (E n > 10 MeV). The irradiated samples were retrieved and remeasured using the same profilometry system in a shielded hot cell facility. Irradiation creep between specimens was compared using standard statistical tests and showed that both thicknesses of CrN coating had a negligible effect on the irradiation creep strain of the Zry material. Microstructure characterization of pre- and post-irradiated CrN-Zry specimens showed minimal changes due to irradiation but did show a substantial O-rich region at the Zry-CrN interface.

36 MATERIALS SCIENCE↗

Phase stability and microstructure of neutron-irradiated substoichiometric yttrium dihydrides

The impact of the neutron-displacement damage on phase stability and microstructure of substoichiometric yttrium dihydrides (YH x , x <2) were investigated to assess their use as solid moderator in high-temperature nuclear reactors. YH x specimens were, thus, subjected to neutron irradiations in the range of 0.1–2 displacements per yttrium atom (dpa-Y) in the temperature range of 536–878°C at the Oak Ridge National Laboratory's (ORNL's) High Flux Isotope Reactor (HFIR). YH x specimens were initially prepared at stoichiometry (H/Y) ratios of 1.69 and 1.83. HFIR-irradiated specimens were characterized by variety of techniques to investigate H retention characteristics including dimensional analysis, optical microscopy, scanning electron microscopy electron back scatter diffraction (EBSD), transmission electron microscopy, thermal desorption spectroscopy (TDS), and high-energy x-ray diffraction (HE-XRD) characterizations. Overall, YH x exhibited notable structural and phase stability under short-term neutron-irradiation, except for the samples with significant silicon carbide (SiC) interaction at high doses and temperatures. Basic dimensional and mass measurements were misleading for accurate assessment of H retention, as confirmed by EBSD phase maps, XRD line profiles, and TDS signals. Thus, it was discussed that a robust H retention metric is needed to assess irradiated hydrides. Further, nanoscale cavities were observed as a result of the neutron irradiation in all samples. Although no clear impact of dose and irradiation temperature was determined, the initial H/Y ratio had an impact on the cavity number density where low H/Y specimens had high-resistance to cavity formation. The Y-vacancy cluster formation at the collision stage of the displacement cascade and their stabilization by H were considered to be the likely underlying mechanisms for the observed cavity microstructure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Incident beamline design for a modern cold triple axis spectrometer at the High Flux Isotope Reactor

A modern cold triple axis spectrometer is being planned for the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Here, we describe the design of an incident beamline that will put a flux of ~ 10 8 $\frac {n}{cm^{2}s}$ on a sample with an area of 2 cm X 2 cm. It takes current physical constraints at HFIR into account and it can accommodate both single and multiplexed analyzer-detector secondary spectrometers and large superconducting magnets. The proposed incident beamline includes a multi-channel guide with horizontal focusing, a neutron velocity selector, components to facilitate an incident beam polarization option, and a double-focusing pyrolytic graphite monochromator. Here, this work describes the process of optimizing the guide system and monochromator and summarizes the expected performance of the incident beamline for non-polarized operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of ray-tracing simulations to confirm performance of the GP-SANS instrument at the High-Flux Isotope Reactor

The CG-2 beamline at the High Flux Isotope Reactor (HFIR) exhibits a notable discrepancy between observed count rates and the count rates we would expect based on a Monte-Carlo neutron ray-trace simulation. These simulations consistently predict count rates approximately five times greater than those observed in four separate experimental runs involving different instrument configurations. This discrepancy suggests that certain factors are causing losses in measurements that are not adequately accounted for in the simulation, in particular guide reflectivity or misalignment. To investigate these discrepancies, a high-dimensional simulation parameter approach is applied in order to understand the losses. Region of Interest (ROI) groups along the instrument are assigned to different surfaces of the guide components within the simulation. This allows the parameters of those guide components to be varied as a group to minimize the complexity of the search space. The result is an optimization of simulation parameters using an iterative scheme that aims to minimize the difference between experimentally measured count rates and simulated count rates across all tested collimator combinations. This proposed methodology holds the potential to reveal previously unrecognized sources of intensity loss in the CG-2 beamline at HFIR and improve the accuracy of simulations, leading to enhanced understanding and performance of the beamline for various scientific applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ROADRUNNER uranium nitride MiniFuel: Experimental design, fabrication and pre-irradiation baseline characterization for accelerated burnup testing

Uranium nitride (UN) is a promising fuel candidate for advanced reactor systems owing to its high uranium density and thermal conductivity; however, its qualification remains constrained by the scarcity of well-controlled irradiation performance data. Here, to address this limitation, the ROADRUNNER (Research On ADvancing the peRformance of UraNium Nitrides in Extreme enviRonments) campaign employs the MiniFuel platform in the High Flux Isotope Reactor (HFIR) to enable accelerated burnup irradiation testing under tightly controlled and largely isothermal conditions. This paper presents the experimental design, fuel fabrication, and pre-irradiation baseline characterization of the ROADRUNNER UN MiniFuel campaign. Thirty-six UN minidisc specimens were fabricated with systematically varied as-fabricated density (86–96% of theoretical density), carbon impurity content (961–5240 ppm), oxygen content (≤ ∼2000 ppm), and grain size (2.5–24 μm). The irradiation matrix spans nominal fuel temperatures of 873 K, 1173 K, and 1473 K and target burnups of 3.75%, 6.0%, and 7.5% fissions per initial metal atom (FIMA). Neutronic and thermal analyses were performed to define specimen-specific burnup accumulation and temperature histories, establishing the boundary conditions for subsequent in-pile behavior. Comprehensive pre-irradiation characterization—including dimensional metrology, density verification, impurity analysis, X-ray diffraction, Raman spectroscopy, scanning electron microscopy, X-ray computed tomography, and confocal profilometry—provides a detailed baseline for post-irradiation examination. Pre-irradiation data were further used to generate predictive estimates of fission gas release and swelling using existing empirical correlations. This quantitative comparison reveals substantial inter-model divergence at intermediate and elevated temperatures that exceeds propagated input uncertainties, highlighting structural gaps in the historical irradiation database. The ROADRUNNER irradiation campaign is currently underway in HFIR, with initial firs cycle completed in late 2025 and remaining targets scheduled through 2027. The experimental design and baseline dataset presented here establish the framework needed to interpret forthcoming post-irradiation measurements and to provide discriminating data for the validation and refinement of physics-based UN fuel performance models.

Lopes, Denise Adorno [Oak Ridge National Laborator↗

A high-efficiency cryogenic neutron spin flipper for IMAGINE-X at the high flux isotope reactor

The Laue neutron macromolecular crystallography beamline, IMAGINE, at the High Flux Isotope Reactor (HFIR) is undergoing a major upgrade to incorporate the dynamic nuclear polarization (DNP) technique. Upon completion, the new IMAGINE-X instrument is expected to enhance the signal-to-noise ratio of the diffraction data by an order of magnitude. To take full advantage of the benefits of DNP, both a highly polarized neutron beam and a high-efficiency neutron spin flipper are required. We have developed a compact cryogenic spin flipper utilizing the Meissner effect in high-Tc yttrium–barium–copper–oxide superconducting films. The flipper has been successfully tested at two HFIR neutron development beamlines, Larmor and Poplar, with neutron wavelengths of 5.3 and 2.4 Å respectively. At Larmor, a flipping efficiency of 0.995 ± 0.004 was achieved for 5.3 Å neutrons, and at Poplar, efficiency of up to 0.9987 ± 0.0004 was obtained for 2.4 Å neutrons. Both tests demonstrated the flipper’s excellent performance and suitability for integration into IMAGINE-X.

Fu, Sichao [Oak Ridge National Laboratory (ORNL), ↗

PROSPECT-II physics opportunities

We report the precision reactor oscillation and spectrum experiment, PROSPECT, has made world-leading measurements of reactor antineutrinos at short baselines. In its first phase, conducted at the high flux isotope reactor (HFIR) at Oak Ridge National Laboratory, PROSPECT produced some of the strongest limits on eV-scale sterile neutrinos, made a precision measurement of the reactor antineutrino spectrum from 235 U, and demonstrated the observation of reactor antineutrinos in an aboveground detector with good energy resolution and well-controlled backgrounds. The PROSPECT collaboration is now preparing an upgraded detector, PROSPECT-II, to probe yet unexplored parameter space for sterile neutrinos and contribute to a full resolution of the reactor antineutrino anomaly, a longstanding puzzle in neutrino physics. By pressing forward on the world’s most precise measurement of the 235 U antineutrino spectrum and measuring the absolute flux of antineutrinos from 235 U, PROSPECT-II will sharpen a tool with potential value for basic neutrino science, nuclear data validation, and nuclear security applications. Following a two-year deployment at HFIR, an additional PROSPECT-II deployment at a low enriched uranium reactor could make complementary measurements of the neutrino yield from other fission isotopes. PROSPECT-II provides a unique opportunity to continue the study of reactor antineutrinos at short baselines, taking advantage of demonstrated elements of the original PROSPECT design and close access to a highly enriched uranium reactor core.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗