At least 145 records · Page 8

Molten Salt vs. Liquid Sodium Receiver Selection Using the Analytic Hierarchy Process

An international team led by NREL analyzed the favorability of two alternative liquid receiver designs for a 700+ degrees C receiver under the Gen3 CSP Liquid Pathway project. The competing liquid heat transfer fluids were a ternary chloride salt and liquid-metal sodium. The team applied a facilitated analytic hierarchy process (AHP) to arrive at a recommended alternative and set a path forward for the project. The AHP criteria were formulated, weighted, and scored by the project leadership team and technical advisory committee consisting of energy industry and CSP experts. The six- month process culminated with a two-day workshop where the sodium alternative was deemed to have both a significantly higher benefit (19.3%) and a lower LCOE (11.4%), with only a slightly higher risk (~3%) than the salt alternative. Consequently, a sodium-receiver design was selected for the Liquid Pathway project, where it will be used to charge a two- tank chloride salt thermal energy storage system.

analytic hierarchy process↗

SAM: A Modern System Code for Advanced Non-LWR Safety Analysis

The System Analysis Module (SAM), developed at Argonne National Laboratory and by collaborators at other organizations, is for advanced non–light water reactor safety analysis. SAM aims to provide fast-running, modest-fidelity, whole-plant transient analysis capabilities that are essential for fast-turnaround design scoping and engineering analyses of advanced reactor concepts. To facilitate code development, SAM utilizes the MOOSE object-oriented application framework, its underlying finite element library, and linear and nonlinear solvers to leverage modern advanced software environments and numerical methods. SAM aims to solve tightly coupled physical phenomena, including fission reaction, heat transfer, fluid dynamics, and thermal-mechanical responses in advanced reactor structures, systems, and components with high accuracy and efficiency. Finally, this paper gives an overview of the SAM code development, including goals and functional requirements, physical models, current capabilities, verification and validation, software quality assurance, and examples of simulations for advanced nuclear reactor applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Solar Thermochemical Carbon Dioxide Splitting Using Ceria and Iron Aluminate Foam Devices and Simulation of a Plant System for Demonstration

An international research project has been undertaken to integrate a unique solar thermal processing reactor system with ceria and iron aluminate as active redox materials for CO2 splitting. Experimental investigations for CO2 splitting were conducted using a solar simulator and tube furnace at Niigata University, followed by demonstrations using a high-flux solar furnace (HFSF) at the National Renewable Energy Laboratory (NREL) in Golden, CO. Each experimental setup consisted of foam devices composed of reticulated porous ceramic (RPC). The RPC has a full ceria or iron aluminate body. It fabricated using the replica method and subjected to a two-step redox reaction, which iteratively separated a stream of CO2 into O2 and CO. Reactivity was evaluated using CO production per mass of the reactive material. The tubular furnace yielded a CO production of 6.41 mL/g at a reduction temperature of 1600degrees C, showcasing a higher CO production rate and total amount than those obtained from experiments conducted with solar simulators and solar furnace setups. For iron aluminate RPC, the productivity was measured as 3.57 mL/g using HFSF at a reduction temperature of 1450degrees C. These results are somewhat higher than those of the previous experiment at lower reduction temperatures of 1400degrees C-1500degrees C. Additionally, the production of CO in the case of ceria RPC was compared with the steady flow model simulation, which assumed chemical equilibrium at various levels of oxygen partial pressure during the reduction process. On the basis of these results, this study proposes a solar fuel system with an open receiver that uses a high-temperature heat transfer fluid.

carbon dioxide thermochemical splitting↗

Direct Measurement of Cl − Activity in Metal Chloride Molten Salts using a Cl 2 /Cl − Electrode

Molten metal chloride salts are promising candidates for advanced heat transfer fluids in generation IV nuclear reactors and beyond. The activity of the chloride ion in the salt has a large influence on the redox characteristics of the corresponding molten salt. There exists a knowledge gap for the direct measurement of chlorobasicity (Lewis basicity) in molten-salt mixtures. Here, the focus of this work was to develop a Cl 2 /Cl − electrode for the direct measurement of chloride activity in molten metal-chloride salt mixtures. The LiCl–KCl eutectic system was utilized as the reference melt to determine the change in chloride ion activity as increasing concentrations of MgCl 2 are added to the LiCl–KCl eutectic working electrode. The results of the measurements indicated a reduction in chloride ion activity as the concentration of magnesium chloride increased, consistent with the complexation of free chlorides by Lewis acidic magnesium cationic species. The Temkin model was used to estimate the thermodynamic properties of MgCl 4 2− complex.

Chloride↗

HyPerPy (Hydrogen Extraction and Parabolic Trough Plant Performance Models using Python) [SWR-21-53]

The HyPerPy package consists of three scripts: 1) Model for Hydrogen Tracking in Parabolic Trough Power Plants, 2) Model for Receiver Performance, and 3) Model for Hydrogen Extraction Process. The power plant model (1) tracks hydrogen generation and transport within the circulating heat transfer fluid (HTF) of the power plant. This script is a transient, initial value simulation, in which the hydrogen concentration in the circulating HTF is 0 moles per cubic meter everywhere at time 0 seconds. Hydrogen concentration is calculated at discrete locations within the circulating HTF with 4-second time resolution. During each time step, the change in hydrogen concentration due to hydrogen generation and permeation is calculated for each location according to the local HTF temperature, vessel or piping properties, hydrogen concentration and partial pressure. This model predicts hourly hydrogen concentrations for typical operating days in the spring, summer, fall, and winter seasons. Data is used to create hourly mappings of hydrogen concentrations for a typical operating year. The receiver model (2) uses a 1-hour time step to estimate getter loading and annulus pressure. For each time step, the model uses HTF and ambient temperature data to estimate absorber tube, bellows, and getter temperatures for the time step. In addition, the model uses hourly HTF hydrogen concentrations that are generated by the power plant model (1), and annulus hydrogen pressure from the previous time step. With these data, the model calculates the moles of hydrogen permeating across the absorber tube and bellows during the time step. The net change in moles hydrogen is added or subtracted from the getter loading for the previous time step, and the hydrogen pressure is re-calculated based on getter loading and temperature. The model uses this algorithm to simulate hydrogen permeation and loading 24 hours per day, 365 days per year using seasonal temperature data. The model repeats these calculations for 25 years to create a mapping of receiver getter loading and annulus hydrogen pressure for four seasons of each year. The model for hydrogen extraction (3) estimates hydrogen extraction rates for a specific separation module configuration. The rate depends primarily on membrane area, vacuum pump performance, headspace gas flowrate to the membrane, and headspace gas hydrogen partial pressure. This model has two versions. The steady-state version predicts hydrogen extraction rates when the module is operating in separation mode. The dynamic version predicts hydrogen transfer through the membrane when the module is operating in sensor mode. The steady-state version is used with the plant model (1) to predict hydrogen partial pressures in the power plant when the extraction process is operating.

Glatzmaier, Gregory↗

Modelling of cracking during beam oscillation laser welding of a creep-resistant nickel alloy

During high power laser welding of Inconel 740H, horizontal solidification cracks form at locations between approximately 70–80% of the weld depth. With the integration of circular beam oscillation, the laser energy density distribution and underlying thermo-mechanical conditions were altered. By coupling three-dimensional heat transfer, fluid flow, and stress modelling tools, the role that circular beam oscillation plays in the formation of the strain rates and stresses driving this cracking phenomenon was identified. While the addition of a circular oscillation pattern appeared to lower the stress levels along the solidification front, it did not eliminate the appearance of horizontal cracking. Only when the beam amplitudes reached 1.6 mm did solidification cracking disappear, but the weld depths were also significantly reduced.

Gao, Mingze↗

High Temperature Erosion In Particle Based CSP Systems

Particle based concentrated solar power plants are increasingly being considered as an alternative to molten salts. Although these particle based systems provide the inherent safety and enhanced lifetime from reduced corrosion compared to molten salt systems, they bring in complexities associated with surface erosion from falling particle impact and sliding motion along the surfaces. Past research on particle related erosion has been limited to high velocity applications and doesn’t necessarily coincide with the operating conditions in CSP systems. In our work, we evaluate characterize the rate of erosion for particles and containment materials at 800ºC. Three different types of erosion resulting from a) impact of solid particles on receiver, particle storage, and heat exchanger walls; b) abrasion erosion from particle sliding motion along walls; and c) attrition erosion as the particles breakdown from particle-to-particle contact and particle-to-wall interactions are evaluated and compared across a varied spectrum of particle and containment material spectrum. From the results, It is noted that temperature plays a key role in the rate of erosion experienced by any material. With the increase in temperature, materials become more ductile and are more readily sheared away from particle impinging or sliding motion. Furthermore, the particles themselves have higher susceptibility to breakdown which also lowers particle thermal absorptance and thus efficiency as heat transfer fluid.

14 SOLAR ENERGY↗

Concurrent Optimization of Capital Cost and Expected O&M

Concentrating solar power (CSP) technologies can utilize heat from concentrated sunlight from a field of tracking mirrors to generate electricity, reform fuel, provide process heat, or augment fossil plant heat sources. Electricity-generating power tower systems focus light from thousands of independent heliostats onto a thermal receiver, which uses the focused light to warm a heat transfer fluid (HTF), typically, a molten nitrate salt. The HTF is then sent to a power generation cycle or diverted into thermal energy storage (TES) for later use. Thermal storage is – in principle – a straightforward proposition. However, optimal utilization of a TES resource is complex and multi-faceted: thermal energy may be dispatched to produce electricity immediately upon first availability, or thermal energy may be reserved for next-day peak periods at risk of filling storage and dumping energy, or a portion of the thermal energy can be reserved to maintain equipment temperatures, reducing power cycle startup time, etc. Many possible dispatch permutations variously emphasize producing peak power, operating through transients, expediting daily startup, etc. The best operation strategy can change day-to-day throughout the year, depending on the weather and market pricing forecasts. The project we describe in this report develops a software package that allows users to explore design optimization, operations decisions, and performance characterization of concentrating solar power tower plants. Users interface with the tool through a scripting language, and results are reported in time series tables, plots, runtime logs, and design outputs. Users choose from a list of variables such as tower height, solar multiple, design-point irradiance, thermal storage size, etc., and specify information about the system using a list of parameters. The software can then optimize the specified variables to reduce the cost of energy produced by the system while meeting certain production requirements, accounting for uncertain weather and electricity price forecasts, and correcting for equipment failures or repair time. The software we develop is the first comprehensive design tool of its kind to incorporate all of these aspects while being deployed as open source.

14 SOLAR ENERGY↗

Abrasion wear at high temperature in particle receiver type Concentrating Solar Power Systems

The use of solid particles as a heat transfer fluid in receivers for concentrating solar powerplants has garnered much attention in the past decade. Particles are not only stable at temperatures above 700 °C but are also able to absorb solar energy directly, which gives them a distinct advantage over conventional molten salts. The use of particles can, however, cause material degradation from the flow of hot or cold particles through discharge hoppers or along the inner receiver surfaces and other system components (e.g. tubes, valves etc.), depending on operating mode of the receiver. Stainless steel alloy 316, nickel-based alloy Inconel® 740H®, Haynes 230, and a 60% alumina, low-cement refractory castable from Allied Mineral Products were tested for wear from first-of-a-kind high-temperature low-velocity abrasion-erosion experiments. The tests are designed to simulate potential conditions in Generation 3 falling particle Concentrating Solar Power (CSP) systems. Simultaneous experiments were conducted at room temperature as well to draw comparison on the role of temperature on abrasion wear rates. It was noted that the abrasion wear rate in candidate materials was driven by the oxidation resistance of the material. The findings from these experiments will be used to determine life-time of critical components in particle receiver concentrated solar powerplants.

14 SOLAR ENERGY↗

High Flux Microchannel Receiver Development (Final Report)

The opportunity addressed in this project was using microscale heat exchanger technology for improving solar thermal central receiver efficiency. This will result in smaller, less expensive components and reduce the levelized cost of electricity from concentrated solar thermal power. This micro-pin solar receiver (MSR) directly heats high pressure (25 MPa) supercritical carbon dioxide (sCO 2 ) from 550°C to 720°C with an incident flux of at least 120 W/cm 2 at a receiver efficiency of >90% (assuming availability of 95% absorptivity coating), and receiver cost target of less than $\$$150/kWt. Realization of the MSR required an understanding of thermal hydraulic performance of sCO 2 in micro-pin passages, mechanical behavior of high nickel alloys at high temperatures including joints, advanced fabrication methods of high nickel alloys (etching, machining, brazing, welding, diffusion bonding), and the cost implications of these when the concept is scaled to production volumes. The technology can be used with gases (sCO 2 , helium, etc.) or with liquids such as molten salt or liquid metal. Given the high pressure associated with sCO 2 , its use demonstrates a “worst case” scenario, and the successful development of the MSR for this application will result in the development of a technology also applicable to a range of other heat transfer fluids that will enable next generation CSP plants, including support of the Gen3CSP program.

14 SOLAR ENERGY↗

Continuous Particle Monitoring and Removal for Molten Chloride CSP Systems

This report describes the technologies that were developed as part of the Continuous Particle Monitoring and Removal for Molten Chloride CSP Systems project that was funded by the EERE Solar Energy Technologies Office during FY2021. This project consisted of two main tasks: (1) the development electrical resistance tomography (ERT) sensors to provide particle sensing capabilities for CSP-relevant molten chloride salts, and (2) the development of vortex separation technologies to enable efficient removal of particles from the salt. Both of these tasks are crucial because, although the Gen3 CSP chloride heat transfer fluid is inexpensive and can achieve high temperatures, major issues with erosion corrosion and clogging can arise from the presence of MgO particles within the salt. The particle monitoring and removal technologies were both demonstrated over the course of this project. The ERT sensors were able to achieve their performance targets by providing accurate particle concentration measurements over a range from 0.0 to 8.0 wt%. The vortex separators were able to demonstrate separation of particles from molten salt streams, but the separation efficiencies were lower than the targeted level of 90%. With further development and deployment, these technologies will ultimately help to enable successful long-term operations of CSP systems that make use of high-temperature chloride salts.

14 SOLAR ENERGY↗

Characterization of Safeguards Implementation Schedules for Advanced Reactors

Advanced reactor designs differ from the traditional light-water reactor designs and operational requirements in nearly every facet, including the heat transfer fluids, operating temperatures and pressures, and fuel cycle requirements. To account for these differences, significant effort will be required to ensure appropriate safeguards implementation for US-based reactors intended for global deployment. This is the second in a series of three reports that examine facets of this issue. The first paper (ORNL/TM-2021/2142) examines potential construction schedules for advanced reactors to create a baseline understanding of the timeframes involved. This second report characterizes International Atomic Energy Agency (IAEA) safeguards implementation schedules for potential advanced reactors. Finally, the third report (ORNL/TM-2021/2208) examines existing gaps for safeguards implementation at advanced reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Status Report on Thermal Delivery Modeling in HYBRID

This report details the modeling efforts consistent with the HYBRID repository of the Integrated Energy Systems (IES) program, motivated to develop information data tables characterizing the thermodynamic losses associated with transporting thermal energy over large distances. The described model establishes a methodology to currently characterize the impacts of certain parameters such as distance, piping geometry, and heat transfer fluid among others as well as sets up ability to interconnect the delivery model into Modelica IES simulations in the future. This report describes the modeling efforts completed and describes some of the future studies that will be done using results produced by the modeling efforts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

3D Printing of Inconel 718 with Enhanced Boron Composition as a Novel Solar Absorber Tube Material in the Concentrated Solar Power (CSP) System

The growing demands for elevated efficiency in the solar energy industry led researchers to focus on the development of functional solar absorber tube material in concentrated solar power (CSP) systems, when molten salts are adopted as the heat transfer fluid. In this study, the typical solar absorber tube material, Inconel 718, was enhanced with boron to achieve a higher solar absorptivity in the visible light spectrum. Combined with an additive manufacturing (AM) method, the boron composition exceeded the traditional manufacturing limit of 60 ppm without microstructural defects. The boron-enhanced Inconel 718 exhibited a high solar absorptivity of nearly 90 % while maintaining a high thermal cycle fatigue resistance after thermal cycling treatment between 550°C and 720°C. The boron composition was increased to the manufacturing failure point, and the effects of different boron compositions on mechanical properties, microstructure, and optical properties were studied. The provided microstructure-property map in this study delivers high potentials of functional AM-printed alloy material in CSP applications.

13 HYDRO ENERGY↗

A Novel Concentrating Solar Weathering Apparatus for Experimental Validation of Multi-Modal Degradation Models

High-performance coatings for Concentrating Solar Power (CSP) receivers are subjected to remarkable environmental stressors during normal operations. Applied to the receiver tubes, these coatings serve to maximize the solar absorptivity of the receiver, transferring as much heat as possible from the solar collectors into the heat-transfer fluid (HTF). The lifecycle of these coatings is not well-defined, and the harsh operational conditions make them difficult to test. NREL has designed, built, and tested an apparatus to expose these samples to design levels of environmental stress and well beyond, into accelerated and destructive conditions. The chamber is actively cooled, monitored, and has the capability to supply humidification for cycling tests, allowing us to test multi-modal degradation and failure conditions at high temperature, high flux, and high humidity conditions. These conditions can catalyze high-temperature oxidation, mechanical degradation, and other modes of absorptivity loss seen in selective solar receiver coatings. The experimental data can feed lifecycle models for expensive and necessarily resilient materials, offering insights to aid maintenance schedules, technoeconomic analysis, and material industry performance benchmarks. This presentation will demonstrate the apparatus design and performance, as well as initial results for aging on a selective receiver coating.

14 SOLAR ENERGY↗

Coatings for CSP Lifetime

The feasibility and performance of tower-technology-based concentrated solar power (CSP) is highly dependent on the efficiency of the energy transformation from sun to heat at the receiver. The higher the solar absorptivity of the receiver coating, the higher the efficiency of the plant as a whole. BrightSource Energy (BSE) has developed a series of High-Performance Coating (HPC) systems in order to achieve high absorptivity over the plant lifetime (25-35 years). This requires stable coatings that are easily applicable on the large receiver surface and will maintain their optical properties under intense solar flux and thousands of heating and cooling cycles in desert conditions. Different coating formulations are required according to the differing plant conditions: receiver materials, operating conditions (temperatures, daily cycles, etc.), and environmental conditions. BSE also developed a coating for the next generation of CSP receivers, such as those being under DOE’s CSP Gen3 program, which will be operated with high temperature heat transfer fluids at temperatures of up to 800°C, which is significantly hotter than the operating temperature of current systems. Once the coating is formulated, the next challenge is evaluating its lifetime properties. BSE has found several independent failure modes that impact HPC absorptivity degradation: • Decrease in HPC optical properties due to oxidation in the receiver tubes surface below the HPC; • HPC film deterioration due to cycling of temperatures and humidity due to daily operation startup and shutdown as well as changing ambient conditions; • Mechanical degradation due to erosion by sand and wind. Existing test methods examine various aspects independently, but do not provide a combined accelerated lifetime result. Creating such a combined test suite, with a way to interpret the results to predict the coating’s projected lifetime, was the ultimate goal of this project. The project was divided into three major workstreams: lab testing (individual failure mode tests and combined failure mode tests); developing a theoretical model for aging; and validation of the test apparatus via on-sun testing in near real-world conditions at CIEMAT-PSA. Developing a test apparatus that accurately controlled the temperature while also introducing the desired solar flux proved more challenging than expected. While in the end we did succeed in creating a test apparatus that can control temperature, solar flux, and humidity, the results did not appear to accelerate the lifetime of the samples as desired. We suspect that to properly accelerate the samples we must also subject the samples to increased amounts of oxygen. Similarly, while we successfully created a combined model that is publicly available, we were unable to validate it sufficiently to feel comfortable recommending it as a general guideline.

14 SOLAR ENERGY↗

THERMS Technology Commercialization Fund Final Report

The technology commercialization fund assisted with the design and development of an intermediate scale packed be thermal energy storage system. Presented in this final report is the design, testing, and modeling of a 100 kWh th radial packed-bed. Air is used as a heat transfer fluid and 3/8” pea gravel is used as the storage medium. Testing has demonstrated the formation of a thermocline within the packed-bed. An air charging temperature of 450 °C was achieved resulting in a charging power of 26.5 kWh th . The radial packed-bed was charged for 5 hours and discharged for 5 hours. Minimal temperature variation was observed at the bottom, middle, and top axial locations of the radial packed-bed which suggests that buoyancy and hydrodynamics in the injection well had a minimal effect on the uniformity of air flow through the bed during charging and discharging. This indicates that the forced convection in a radial direction is dominating the flow regime compared to the buoyancy. The findings of this study suggest an increased air duct diameter through the air heater will increase the charging temperature and increase air mass flow through the system. Increased mass flow through the packed-bed is hypothesized to shorten the thermocline length. Modeled and measured results are compared, and it is here determined that a more comprehensive CFD model will aid in the understanding of air flow and thermocline evolution within the packed-bed.

25 ENERGY STORAGE↗

Shaping High Efficiency, High Temperature Cavity Tubular Solar Central Receivers

High temperature solar receivers are developed in the context of the Gen3 solar thermal power plants, in order to power high efficiency heat-to-electricity cycles. Since particle technology collects and stores high temperature solar heat, CNRS (French National Center for Scientific Research) develops an original technology using fluidized particles as HTF (heat transfer fluid). The targeted particle temperature is around 750 °C, and the walls of the receiver tubes, reach high working temperatures, which impose the design of a cavity receiver to limit the radiative losses. Therefore, the objective of this work is to explore the cavity shape effect on the absorber performances. Geometrical parameters are defined to parametrize the design. The size and shape of the cavity, the aperture-to-absorber distance and its tilt angle. A thermal model of a 50 MW hemi-cylindrical tubular receiver, closed by refractory panels, is developed, which accounts for radiation and convection losses. Parameter ranges that reach a thermal efficiency of at least 85% are explored. This sensitivity analysis allows the definition of cavity shape and dimensions to reach the targeted efficiency. For an aperture-to-absorber distance of 9 m, the 85% efficiency is obtained for aperture areas equal or less than 20 m2 and 25 m2 for high, and low convection losses, respectively.

Gueguen, Ronny (ORCID:0000000252368638)↗