Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Geometrical correction factors for heat flux meters

General formulas are derived for determining gage averaging errors of strip-type heat flux meters used in the measurement of one-dimensional heat flux distributions. The local averaging error e(x) is defined as the difference between the measured value of the heat flux and the local value which occurs at the center of the gage. In terms of e(x), a correction procedure is presented which allows a better estimate for the true value of the local heat flux. For many practical problems, it is possible to use relatively large gages to obtain acceptable heat flux measurements.

Baumeister, K. J.↗

Corrections of Heat Flux Measurements on Launch Vehicles

Knowledge of aerothermally induced convective heat transfer is important in the design of thermal protection systems for launch vehicles. Aerothermal models are typically calibrated via the data from circular, in-flight, flush-mounted surface heat flux gauges exposed to the thermal and velocity boundary layers of the external flow. Typically, copper or aluminum Schmidt- Boelter gauges, which take advantage of the one-dimensional Fourier's law of heat conduction, are used to measure the incident heat flux. This instrumentation, when surrounded by low-conductivity insulation, has a wall temperature significantly lower than the insulation. As a result of this substantial disturbance to the thermal boundary layer, the heat flux incident on the gauge tends to be considerably higher than it would have been on the insulation had the calorimeter not been there. In addition, radial conductive heat transfer from the hotter insulation can cause the calorimeter to indicate heat fluxes higher than actual. An overview of an effort to develop and calibrate gauge correction techniques for both of these effects will be presented.

Reinarts, Thomas R.↗

Tidal and atmospheric forcing of the upper ocean in the Gulf of California. 2: Surface heat flux

Satellite infrared imagery and coastal meteorological data for March 1984 through February 1985 are used to estimate the net annual surface heat flux for the northern Gulf of California. The average annual surface heat flux for the area north of Guaymas and Santa Rosalia is estimated to be +74 W/sq m for the 1984-1985 time period. This is comparable to the +20-50 W/sq m previously obtained from heat and freshwater transport estimates made with hydrographic surveys from different years and months. The spatial distribution of the net surface heat flux shows a net gain of heat over the whole northern gulf. Except for a local maximum near San Esteban Island, the largest heat gain (+110-120 W/sq m) occurs in the Ballenas and Salsipuedes channels, where strong tidal mixing produces anomalously cold sea surface temperatures (SSTs) over much of the year. The lowest heat gain occurs in the Guayamas Basin (+40-50 W/sq m), where SSTs are consistently warmer. In the relatively shallow northern basin the net surface heat flux is farily uniform, with a net annual gain of approxmately +70 W/sq m. A local minimum in heat gain (approximately +60 W/sq m) is observed over the shelf in the northwest, where spring and summer surface temperatures are particularly high. A similar minimum in heat gain over the shelf was observed in a separate study in which historical SSTs and 7 years (1979-1986) of meteorological data from Puerto Penasco were used to estimate the net surface heat flux for the northern basin. In that study, however, the heat fluxes were higher, with a gain of +100 W/sq m over the shelf and +114 W/sq m in the northern basin. These larger values are directly attributable to the higher humidities in the 1979-1986 study compared to the 1984-1985 satellite study. High humidities reduce evaporation and the associated latent heat loss, promoting a net annual heat gain. In the norther Gulf of California, however, tidal mixing appears to play a key role in the observed gain of heat. Deep mixing in the island region produces a persistent pool of cold water which is mixed horizontally by the large-scale circulation, lowering surface temperatures over most of the northern gulf. These cold SSTs decrease evaporation by reducing the saturation vapor pressure of the overlying air. As a result, heat loss is substantially reduced, even when humidities are low. By removing heat from the surface, tidal mixing alters the time scale of air-sea interaction and reduces or possibly even inhibits the formation of deep water masses via convection.

Paden, Cynthia A.↗

Design and Analysis of High Heat Flux Plasma-Facing Components for NSTX Upgrade

The National Spherical Tokamak Experiment (NSTX) upgrade (NSTX-U) requirements lead to enhanced heat loads on plasma-facing components (PFCs) especially in the divertor regions, where normal heat flux density can reach up to 8 MW/m 2 . For these high heat flux (HHF) regions, the PFCs were redesigned, to use castellations which relieved the thermal stresses associated with high incident heat flux. Another design feature of HHF PFCs is the absence of front face mounting holes which create localized areas of high temperature and thermal stress concentrations. Optimized shaping of the front face of the HHF PFCs eliminates regions where the front face is perpendicular to the heat flux direction during normal helicity operation and spreads the heat load. A unique mechanism was designed to connect PFC tiles to the NSTX-U center stack casing using locking features accessible from the low heat flux regions. Isotropic graphite was selected as the HHF PFC tile material. Initial tile design parameters were accessed using analytical expressions for pulsed heat flux loading. A working prototype of the locking mechanism was created during the initial stages of the design to prove the concept performance. This article presents an overview of the divertor HHF PFC design and the results of the thermal and structural analyses performed using ANSYS software. The results of the analyses cover normal operating conditions and disruptions which impose electromagnetic (EM) loads from eddy and halo currents. The 3-D, transient, nonlinear analyses took into account the temperature-dependent properties of the materials, friction interfaces between the parts, and variable electric properties of the parts and interfaces. The results confirm that the HHF PFC tiles remain within the allowable limits for the loads defined by the NSTX-U Recovery Project. In addition, tolerance stack up analyses were performed to ensure tile performance in the worst possible assembly configuration. Finally, the design process was completed successfully, and the NSTX HHF PFC tiles are currently in the production phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dual-Active-Surface Miniature Plug-Type Heat-Flux Gauges

Improved miniature plug-type heat-flux gauges developed for determining fluxes of heat through surfaces on both sides of heat-transfer walls. Walls are those of heat exchangers, engine housings, furnaces, chemical reactors, or any of variety of other structures in which fluxes of heat important quantities one seeks to measure.

Liebert, Curt H.↗

MHD-induced SOL filaments and divertor heat flux striations in NSTX

Magnetohydrodynamic (MHD) activity in NSTX has been found to induce striated heat flux patterns at the divertor. These striated heat fluxes were previously interpreted as strike-point splitting caused by stochastic magnetic lobes near the X-point. Recent analysis indicates that MHD can directly generate filaments in the scrape-off layer (SOL), and the MHD-related filaments are consistent with the rotation and the frequency of the MHD. Magnetic field line tracing from the mid-plane of the MHD-related filaments to the divertor is consistent with the location of striated heat fluxes on the divertor. Additionally, gas puff imaging (GPI) diagnostic data shows the generation of regular blobs following each edge harmonic oscillation (EHO) toroidal mode number n = 1 perturbation, which indicates that the MHD perturbation directly drives the blobs. These blobs are responsible for the divertor heat flux striations. Here, this finding provides a new framework for understanding MHD-induced edge transport and has important implications for heat-load control in NSTX-U and future spherical tokamaks.

MHD↗

LOFTID Heat Flux Gauge Calibration: What is Truth?

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) is a demonstration of Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology, which may enable the delivery of heavy payloads to Mars, Venus, and Titan, as well as return to Earth. Unlike rigid aeroshells that are constrained by the size of the rocket’s shroud, inflatable aeroshells can be deployed to a much larger scale, thus allowing a spacecraft to begin its deceleration earlier and experience less heating. On LOFTID, there will be 4 total heat flux gauges (HFG) with a range of 70 W/cm2 and 1 radiometer with a range of 3 W/cm2, arranged as shown in Fig. 1. Both the radiometer and total HFGs are Schmidt-Boelter gauges purchased from an external vendor. Radiative calibrations were performed in-house at NASA Ames’ Sensors and TPS Advanced Research Laboratories (STAR Labs) before and after environmental testing to investigate how the testing affected the sensors' response. Additional rounds of radiative calibration at STAR Labs were also performed in order to investigate the large uncertainties associated with these tests. For example, a survey of multiple calibration facilities concluded that the uncertainty within a given facility was +/-3% [1]. An additional NIST study that calibrated heat flux gauges at 7 different facilities also found the variation in calibration coefficients to be up to ~3% within a given facility, but up to 15% between facilities, suggesting systematic differences between test setups [2]. Finally, the response of heat flux gauges to radiative versus convective heat flux has shown to differ by up to 20% [3],[4]. Because the heat flux gauges on LOFTID will predominantly experience convective heat flux during flight, a convective calibration study was performed at Boeing's Large-Core Arc Tunnel (LCAT) facility. Radiative Calibration Procedure The calibrations performed at STAR Labs utilize a quartz lamp bank (QLB) that provides a maximum heat flux of 50 W/cm2, which bounds the expected LOFTID flight environment. The calibration involves exposing a water-cooled Gardon gauge (reference) and then the unit-under-test (UUT) to 5 different heat fluxes multiple times for 10 seconds each, and then calculating a linear fit. The test setup is shown in Fig. 2. The total HFGs were calibrated at STAR Labs 3 times, denoted as STAR 1 (before environmental testing), STAR 2 (after protoflight vibration and thermal-vacuum testing), and STAR 3 (no change from previous test). All 8 flight-lot total HFGs showed a decrease in full-scale output from STAR 1 to STAR 2 by between 0.5% and 10. The first portion of this investigation was to determine whether the change could be due to differences in temperature between the two calibration runs. A typical linear fit to the calibration data was performed using Eq. 1 where q’ is the heat flux in W/cm2, c is the calibration coefficient, and mV is the sensor output. To account for temperature, the data were fit to a nonlinear function that included both the sensor output (mV) and the temperature from the thermocouple embedded inside the HFG near the surface (T): q'=mV/(c1* T + c0}. The residuals between the fits and the actual data points were calculated for every point, and proven to be much smaller for the temperature-compensated fits than for the linear fits for all sensors. An example is shown in Fig. 3. When the temperature-compensated fits from STAR 1 were applied to the STAR 2 data, the residuals did not improve, suggesting that the change in sensitivity between these two calibration runs was not due to temperature. A third round of calibration (STAR 3) was conducted to further address the temperature dependence of the total HFGs, and the resulting sensitivities matched closely to STAR 2 (within 2%). Temperature-compensated calibration curves were once again fit to the data. In this case, when the temperature-compensated fits from STAR 3 were applied to STAR 2 data, the residuals between the fits and STAR 2 data were much lower than the residuals due to the linear fits. This suggests that the changes seen between STAR 1 and STAR 2 were likely due to actual changes in the sensors caused by the environmental testing between the two calibrations. A modification of the original calibration process, in which the UUT was exposed to each heat flux for just 3 seconds (instead of 10) to reduce the temperature increase during the test, was additionally performed on several of the HFGs. In general, the sensitivities were 1-1.5% lower than from the 10-second tests, but the temperatures were also significantly lower. When the temperature-compensated fits from the 10-second tests were applied to the 3-second test data, the residuals were greatly improved than when just using the linear fits, further suggesting that the temperature-compensated fits may lead to better accuracy than the linear fits in flight. Convective Calibration The second portion of this study was to create a mapping between the radiative and convective calibration coefficients. The majority of the heating during flight will be convective, so it is important to understand how the HFG response differs under these conditions. However, there are no standardized methods for convective calibration [5]. Because the TPS aerothermal response models were validated at LCAT, the same facility was chosen for convective calibration of two of the total HFGs (Fig. 4). Preliminary results showed that the full-scale output was 3% and 8% higher in convective heat flux as compared to radiative heat flux. However, tunnel variation may have contributed to noise and uncertainty in the measurements, and more testing and analysis remains to be done. Scope of Presentation The presentation will include an overview of the changes seen in HFG calibration before and after environmental testing, differences between radiative and convective calibrations, the modeling work done to aid in understanding the sensor response to varying environments, and recommended future work.

H S Alpert↗

Simulations of heat fluxes in an ELMy H-mode discharge on HL-2A

In order to study the distribution and evolution of the transient heat flux on HL-2A during edge-localized-mode (ELM) bursts, the BOUT++ electromagnetic six-field two-fluid model is used to simulate the pedestal collapse under the lower single-null divertor geometry. The equilibrium profiles of HL-2A ELMy H-mode discharge No. 24 953 are adopted as the initial condition in the original case. In this instance, linear analysis shows that the resistive ballooning mode (RBM) and drift-Alfven wave are unstable to this equilibrium, and RBM is the dominant instability. The evolutions of the radial heat fluxes at the outer mid-plane and heat fluxes to the inner and outer targets during the ELM event are presented. Six more equilibria are constructed based on the original case to find out the influence of the pedestal profiles on the peak electron heat flux. The results indicate that the heat flux increases with temperature and/or density, and the theoretical analysis and simulation results consistently show that the heat flux q ∥e is proportional to n e0,SEP $T^{\frac32}_{e0,SEP}$.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inferring the scrape-off layer heat flux width in a divertor with a low degree of axisymmetry

Plasma facing components (PFCs) in the next generation of tokamak devices will operate in challenging environments, with heat loads predicted to exceed 10 MWm -2 . The magnitude of these heat loads is set by the width of the channel, the ‘scrape-off layer’ (SOL), into which heat is exhausted, and can be characterised by an e-folding length scale for the decay of heat flux across the channel. It is expected this channel will narrow as tokamaks move towards reactor relevant conditions. Understanding the processes involved in setting the SOL heat flux width is imperative to be able to predict the heat loads PFCs must handle in future devices. Measurements of the SOL width are performed on the high-field spherical tokamak, ST40, using a newly commissioned infrared thermography system. With its high on-axis toroidal magnetic field (≥1.5 T) ST40 is uniquely positioned to investigate the influence of toroidal field on the heat flux width in spherical tokamaks, whilst also extending measurements of the SOL width in spherical tokamaks to increased poloidal field (≥0.3 T). Due to the divertor on ST40 having a low degree of axisymmetry, it is necessary for a set of radial measurements of the heat flux to be taken across the divertor, made possible using an automated toolchain that fully incorporates its 3D geometry. These radial profiles are combined with the magnetic geometry of the plasma to infer the width of the SOL, with both Eich and double exponential profiles of heat flux observed. A reduction in the heat flux is observed toroidally across part of the divertor, along with increased heat loads observed locally around the edges of the tiles. Future work in characterising the impact of tile misalignment and uncertainties in the reconstructed divertor magnetic geometry is required in order to further understand the observed heat flux patterns, as are additional investigations into the role potentially being played by an inhomogeneous sheath electric field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 2D Kaleidoscope of Electron Heat Fluxes Driven by Auroral Electron Precipitation

Electron heat flux is an important value for ionospheric space weather modeling networks. Utilizing the 2D array of Time History of Events and Macroscale Interactions during Substorms all-sky-imager (ASI) observations, Gabrielse et al. (2021, https://doi.org/10.3389/fphy.2021.744298) described a new method that estimates the auroral scale sizes of intense precipitating electron energy fluxes and their mean energies during two substorms on 16 February 2010. These parameters in combination with SuperThermal Electron Transport code were used to develop a new methodology to calculate electron thermal fluxes from data inputs in 2D during one of the substorms at 09:40:00 UT across Canada and Alaska. To test the effect of various precipitation lifetimes on electron heat flux values, boxcar averages ranging from 0 to 900 s were applied to the ASI data. These data are then combined with the newly developed kinetic simulation to determine the thermal fluxes associated with the observed diffuse and discrete precipitation.

Electron precipitation in aurora↗

Heat flux calibration facility capable of SSME conditions

There is a need to more thoroughly characterize the hostile space shuttle main engine (SSME) turbopump environment. It has been estimated that component surface heat flux in the hot-gas environment is about 10 MW/square meter, and this is about 50 times that encountered in aircraft engines. Also, material temperature transients can be as high as 1000 K in about 1 second. These transients can cause durability problems such as material cracking. Heat flux sensors placed in the turbopump components can partially characterize this environment by measuring surface heat flux. These heat flux data can be used to verify analytical-stress, boundary-layer, and heat-transfer design models. Preliminary plans were discussed at the first SSME durablity conference for designing and fabricating a new facility for the calibration and durability testing of prototype heat flux sensors for the SSME. This facility, which is necessary for assessment of new heat flux gauge concepts needed in the hostile SSME turbopump environment, is described.

Liebert, Curt H.↗

Evaporation on/in Capillary Structures of High Heat Flux Two-Phase Devices

Two-phase devices (heat pipes, capillary pumped loops, loop heat pipes, and evaporators) have become recognized as key elements in thermal control systems of space platforms. Capillary and porous structures are necessary and widely used in these devices, especially in high heat flux and zero-g applications, to provide fluid transport and enhanced heat transfer during vaporization and condensation. However, some unexpected critical phenomena, such as dryout in long heat pipe evaporators and high thermal resistance of loop heat pipe evaporators with high heat fluxes, are possible and have been encountered in the use of two-phase devices in the low gravity environment. Therefore, a detailed fundamental investigation is proposed to better understand the fluid behavior in capillary-porous structures during vaporization at high heat fluxes. The present paper addresses some theoretical aspects of this investigation.

Faghri, Amir↗

Computation of full-coverage film-cooled airfoil temperatures by two methods and comparison with high heat flux data

Two methods were used to calculate the heat flux to full-coverage film cooled airfoils and, subsequently, the airfoil wall temperatures. The calculated wall temperatures were compared to measured temperatures obtained in the Hot Section Facility operating at real engine conditions. Gas temperatures and pressures up to 1900 K and 18 atm with a Reynolds number up to 1.9 million were investigated. Heat flux was calculated by the convective heat transfer coefficient adiabatic wall method and by the superposition method which incorporates the film injection effects in the heat transfer coefficient. The results of the comparison indicate the first method can predict the experimental data reasonably well. However, superposition overpredicted the heat flux to the airfoil without a significant modification of the turbulent Prandtl number. The results suggest that additional research is required to model the physics of full-coverage film cooling where there is significant temperature/density differences between the gas and the coolant.

Gladden, H. J.↗

Comparison of Thin Film Heat Flux Gauge Technologies Emphasizing Continuous-Duration Operation

Abstract Thin-film heat flux gauges (HFGs) have been used for decades to measure surface temperatures and heat flux in test turbines with the majority being used in facilities that are short-duration. These gauges are typically composed of two resistive temperature devices deposited on opposing sides of a dielectric. However, because these sensors have been traditionally applied for measurements in transient-type facilities, the challenges facing adaptation of this technology for a steady facility warrant investigation. These challenges are highlighted, and the solutions are presented throughout the paper. This paper describes the nanofabrication process for heat flux gauges and a new calibration method to address the potential deterioration of gauges over long runtimes in continuous-duration facilities. Because the primary uncertainty of these sensors arises from the ambiguity of the thermal properties, the emphasis is placed on the property determination. Also, this paper presents a discussion on the use of impulse response theory to process the data showing the feasibility of the method for steady-duration facilities after an initial settling time. The latter portion of the paper focuses on comparing well-established heat flux gauges developed for short-duration turbine test facilities to recently developed gauges fabricated using modern nanofabrication techniques for a continuous turbine test facility. The gauges were compared using the test case of an impinging jet over a range of Reynolds numbers. The comparison between the PSU gauge and the reference device indicated agreement within 14%, and similar results were achieved through comparison with established sensors from partner institutions.

Engineering↗

Ground Heat Flux Reconstruction Using Bayesian Uncertainty Quantification Machinery and Surrogate Modeling

Ground heat flux (G 0 ) is a key component of the land-surface energy balance of high-latitude regions. Despite its crucial role in controlling permafrost degradation due to global warming, G 0 is sparsely measured and not well represented in the outputs of global scale model simulation. In this study, an analytical heat transfer model is tested to reconstruct G 0 across seasons using soil temperature series from field measurements, Global Climate Model, and climate reanalysis outputs. The probability density functions of ground heat flux and of model parameters are inferred using available G 0 data (measured or modeled) for snow-free period as a reference. When observed G 0 is not available, a numerical model is applied using estimates of surface heat flux (dependent on parameters) as the top boundary condition. These estimates (and thus the corresponding parameters) are verified by comparing the distributions of simulated and measured soil temperature at several depths. Aided by state-of-the-art uncertainty quantification methods, the developed G 0 reconstruction approach provides novel means for assessing the probabilistic structure of the ground heat flux for regional permafrost change studies.

54 ENVIRONMENTAL SCIENCES↗

Sabots, Obturator and Gas-In-Launch Tube Techniques for Heat Flux Models in Ballistic Ranges

For thermal protection system (heat shield) design for space vehicle entry into earth and other planetary atmospheres, it is essential to know the augmentation of the heat flux due to vehicle surface roughness. At the NASA Ames Hypervelocity Free Flight Aerodynamic Facility (HFFAF) ballistic range, a campaign of heat flux studies on rough models, using infrared camera techniques, has been initiated. Several phenomena can interfere with obtaining good heat flux data when using this measuring technique. These include leakage of the hot drive gas in the gun barrel through joints in the sabot (model carrier) to create spurious thermal imprints on the model forebody, deposition of sabot material on the model forebody, thereby changing the thermal properties of the model surface and unknown in-barrel heating of the model. This report presents developments in launch techniques to greatly reduce or eliminate these problems. The techniques include the use of obturator cups behind the launch package, enclosed versus open front sabot designs and the use of hydrogen gas in the launch tube. Attention also had to be paid to the problem of the obturator drafting behind the model and impacting the model. Of the techniques presented, the obturator cups and hydrogen in the launch tube were successful when properly implemented

obturators↗

Average Heat Flux Measurements in a Gaseous Detonation-Based Rocket Engine

Rotating detonation rocket engines (RDREs) offer benefits over traditional deflagrative engines, including increased engine performance, compact combustion and negligible detrimental thermoacoustic instabilities due to mode-locking. Realizing the benefits of a detonation-based propulsion system will be accompanied by increased thermal loads due to a combination of heat release at elevated pressure and temperature, as well as compact heat release due to detonation. Managing these heat loads necessitates the development of thermal management strategies. As a first step towards establishing the requirements for detonation-based engine thermal management strategies, this work develops an additively manufactured (AM) water-based, axially resolved calorimeter for integration in an existing 76.8 mm outer diameter (OD) RDRE to measure average chamber heat flux. In particular, the calorimetry outer body provides average heat flux data via circumferential channels at nine axial stations to axially resolve the heat flux distribution on the chamber outer wall. The average heat flux is found to be 5 − 12 MW/m 2 for a straight annulus and 6 − 18 MW/m 2 for a constricted annular configuration which exhibited maximum heat flux at the throat. A difference in heat flux scaling is observed near the detonation region compared to the downstream flow expansion section in the constricted geometry. By quantifying the axial distribution of heat flux, this work seeks to support the development of thermal management systems for long duration firing of detonation-based devices.

Matthew A Maybee↗

Average Heat Flux Measurements in a Gaseous Detonation-Based Rocket Engine

Rotating detonation rocket engines (RDREs) offer benefits over traditional deflagrative engines, including increased engine performance, compact combustion and negligible detrimental thermoacoustic instabilities due to mode-locking. Realizing the benefits of a detonation-based propulsion system will be accompanied by increased thermal loads due to a combination of heat release at elevated pressure and temperature, as well as compact heat release due to detonation. Managing these heat loads necessitates the development of thermal management strategies. As a first step towards establishing the requirements for detonation-based engine thermal management strategies, this work develops an additively manufactured (AM) water-based, axially resolved calorimeter for integration in an existing 76.8 mm outer diameter (OD) RDRE to measure average chamber heat flux. In particular, the calorimetry outer body provides average heat flux data via circumferential channels at nine axial stations to axially resolve the heat flux distribution on the chamber outer wall. The average heat flux is found to be 5 − 12 MW/m 2 for a straight annulus and 6 − 18 MW/m 2 for a constricted annular configuration which exhibited maximum heat flux at the throat. A difference in heat flux scaling is observed near the detonation region compared to the downstream flow expansion section in the constricted geometry. By quantifying the axial distribution of heat flux, this work seeks to support the development of thermal management systems for long duration firing of detonation-based devices.

Matthew A Maybee↗