WVU Hydrogen Fuel Dispensing Station

The scope of this project was changed during the course of the project. Phase I of the project was to construct a site similar to the site at Central West Virginia Regional Airport in Charleston, WV to show that duplication of the site was a feasible method of conducting hydrogen stations. Phase II of the project was necessitated due to a lack of funding that was planned for the development of the station in Morgantown. The US Department of Energy determined that the station in Charleston would be dismantled and moved to Morgantown and reassembled at the Morgantown site. This necessitated storage of the components of the station for almost a year at the NAFTC Headquarters which caused a number of issues with the equipment that will be discussed in later portions of this report. This report will consist of PHASE I and PHASE II with discussions on each of the tasks scheduled for each phase of the project.

08 HYDROGEN↗

Experimental Comparison of Hydrogen Refueling with Directly Pressurized vs. Cascade Method

This paper presents a comparative analysis of two hydrogen station configurations during the refueling process: the conventional “directly pressurized refueling process” and the innovative “cascade refueling process.” The objective of the cascade process is to refuel vehicles without the need for booster compressors. The experiments were conducted at the Hydrogen Research and Fueling Facility located at California State University, Los Angeles. In the cascade refueling process, the facility buffer tanks were utilized as high-pressure storage, enabling the refueling operation. Three different scenarios were tested: one involving the cascade refueling process and two involving compressor-driven refueling processes. On average, each refueling event delivered 1.6 kg of hydrogen. Although the cascade refueling process using the high-pressure buffer tanks did not achieve the pressure target, it resulted in a notable improvement in the nozzle outlet temperature trend, reducing it by approximately 8 °C. Moreover, the overall hydrogen chiller load for the two directly pressurized refuelings was 66 Wh/kg and 62 Wh/kg, respectively, whereas the cascading process only required 55 Wh/kg. This represents a 20% and 12% reduction in energy consumption compared to the scenarios involving booster compressors during fueling. The observed refueling range of 150–350 bar showed that the cascade process consistently required 12–20% less energy for hydrogen chilling. Additionally, the nozzle outlet temperature demonstrated an approximate 8 °C improvement within this pressure range. These findings indicate that further improvements can be expected in the high-pressure region, specifically above 350 bar. This research suggests the potential for significant improvements in the high-pressure range, emphasizing the viability of the cascade refueling process as a promising alternative to the direct compression approach.

08 HYDROGEN↗

Holistic Fuel Cell Electric Vehicle/Hydrogen Station Optimization Model (CRADA CRD-18-00745 Final Report)

The National Renewable Energy Lab (NREL), Argonne National Lab (ANL), Sandia National Lab (SNL), and Frontier Energy, Inc comprise a team that will perform a review of currently available models that can simulate both a hydrogen station and a fuel cell electric vehicle (FCEV), and whose owners are willing to make them available freely. We will then down select to a single model or model pair, secure agreements for their free use, and validate the resulting model or coupled models. For example, we may evaluate an existing 1-D hydrogen fueling model developed by Kyushu University for the Japanese New Energy and Industrial Technology Development Organization (NEDO). The validation will take place using data from various sources, potentially including the European Joint Research Center (JRC) HyTransfer project, SAE testing performed by Powertech to validate SAE J2601, and whole-station validation using the NREL’s Hydrogen Infrastructure Testing and Research Facility (HITRF). The team will make the model and all the validation data open to the public at the end of the project.

1-D hydrogen fueling model↗

Development of the HyStEP Device

With the introduction of more fuel cell electric vehicles (FCEVs) on U.S. roadways, especially in California, the need for available hydrogen refueling stations is growing. While funding from the California Energy Commission is helping to solve this problem, solutions need to be developed and implemented to help reduce the time to commission a hydrogen station. The current practice of hydrogen station acceptance can take months because each vehicle manufacturer conducts their own testing and evaluation. This process is not practical or sufficient to support the timely development of a hydrogen fueling station network. To address this issue, as part of the Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Project Sandia National Laboratories and the National Renewable Energy Laboratory along with a team of stakeholders and contractor Powertech Labs has developed the Hydrogen Station Equipment Performance (HyStEP) Device. The HyStEP Device is intended to be a surrogate for FCEVs that can be used to collect data on hydrogen station fueling performance. The device includes three Type IV 70 MPa tanks capable of storing a total of 9 kg H2 that are instrumented with pressure and temperature sensors. The tanks can be used individually or in parallel to simulate small, medium, and large fuel systems. The tanks are connected to a 70 MPa receptacle equipped with pressure and temperature sensor as well as infrared communications integrated with a data acquisition, analysis, and control system. The HyStEP Device is capable of performing tests defined in the test method standard CSA HGV 4.3 and providing the data needed to ensure that hydrogen stations meet the fueling protocol standard SAE J2601-2014. These include IrDA communication tests, fault detection tests, and communication and non-communication fueling.

30 DIRECT ENERGY CONVERSION↗

Operational optimization for multi-functional charging station with electric and hydrogen-powered vehicles

The rapid adoption of electric vehicles (EVs) and hydrogen fuel cell vehicles (HFCVs), combined with global efforts to reduce carbon emissions, has accelerated the development of EV charging and hydrogen refueling stations. In response to this demand, this paper introduces the concept of Multi-Functional Charging Station (MFCS) that integrates power generation, EV charging, battery swapping, and hydrogen refueling. A comprehensive operational model is developed for the MFCS that couples electricity and hydrogen conversion and storage technologies to enhance infrastructure utilization and improve overall system efficiency. The model also considers multiple revenue streams, including participation in energy and ancillary markets. To validate the effectiveness of the proposed model and evaluate its performance, a series of numerical experiments are conducted with different charger numbers, different electricity purchase limits, and different charger allocations. Numerical results demonstrate that shared charger configurations can lead to 8.11 % improvement in operational profit by improving resource utilization and reducing the number of depleted batteries at the end of operations compared to allocated charger setups. By varying the number of chargers, sensitivity analysis identifies diminishing marginal returns beyond about 45 chargers, suggesting it as an optimal sizing point under current settings. The integration of electricity and hydrogen conversion is also explored under scenarios with limited external electricity purchases. In conclusion, these findings indicate that optimizing charger allocation and energy management can significantly enhance station productivity and profitability, ultimately supporting the broader adoption of electrified and hydrogen-based transportation solutions.

Charging station↗

Maritime Fuel Cell Generator Project: 2018 – 2023

This report summarizes activity in the Maritime Fuel Cell (MarFC) Generator Project from 2018 – 2023. FY 2018 saw the implementation of upgrades and repairs, making the unit more reliable and operator friendly. In FY2019 the team engaged the Scripps Institution of Oceanography (SIO) to use the MarFC to provide zero-emission shore power to the research vessel R/V Robert Gordon Sproul while in port at the Nimitz Marine Facility in San Diego, CA. In FY2020, the MarFC unit was shipped to San Diego, CA. A fueling contract with IGX was established to support MarFC operations at SIO, with renewable hydrogen provided by the California State University Los Angeles (CSULA) hydrogen station. The project team (Sandia, Cummins/Hydrogenics) provided training to SIO staff on the technical details of the MarFC, the safe use of hydrogen in general and the MarFC in particular. The first fueling of the unit at the SIO pier was successfully completed by IGX. The first powering of a vessel with fuel-cell shore power was conducted with the R/V Robert Gordon Sproul. While the mechanical systems (lights, AC, ventilation, hydraulics, pumps and cranes) were powered without incident, problems arose when powering the computer systems. Inspections carried out in FY2021 revealed the MarFC needed routine maintenance. Maintenance was performed and the unit was upgraded. The MarFC was turned on after the year pause, and initial test data on power levels and stability were collected. FY2022 was a year spent repairing, upgrading and testing the MarFC unit. Spikes in power and voltage were observed above 60 kW that could potentially extend below 60 kW with time. Such spikes could cause problems with the Sproul electrical systems. These age-related problems, the extended time for the Sproul spent in dry dock for scheduled upgrades, and the associated need to reschedule the vessel’s high-priority science missions made it no longer possible to deploy the unit at SIO. After due consideration, the decision was made by DOE, MARAD and the project team to cease the deployment, remove the MarFC from SIO, and not pursue further deployment activities. On December 2, 2022, the MarFC unit was removed from the Scripps Nimitz Marine Facility and shipped to Fridley, Michigan. The Cummins/Hydrogenics plan for the unit is to assess the condition of the MarFC subcomponents, and then use it as a training/learning system for technical employees new to hydrogen fuel-cell technology. After summarizing project activity from 2018 – 2023, this report provides a review of lessons learned. This report provides next steps in contemplating a follow-on project that would further advance the use of fuel-cell-based shore power in a marine setting. A comparison is made of the project results to the original objectives. This report ends with an accounting of presentations stemming from the project, and a list of references.

08 HYDROGEN↗

Update on International Space Station Nickel-Hydrogen Battery On-Orbit Performance

International Space Station (ISS) Electric Power System (EPS) utilizes Nickel-Hydrogen (Ni-H2) batteries as part of its power system to store electrical energy. The batteries are charged during insolation and discharged during eclipse. The batteries are designed to operate at a 35% depth of discharge (DOD) maximum during normal operation. Thirty-eight individual pressure vessel (IPV) Ni-H2 battery cells are series-connected and packaged in an Orbital Replacement Unit (ORU). Two ORUs are series-connected utilizing a total of 76 cells, to form one battery. The ISS is the first application for low earth orbit (LEO) cycling of this quantity of series-connected cells. The P6 (Port) Integrated Equipment Assembly (IEA) containing the initial ISS high-power components was successfully launched on November 30, 2000. The IEA contains 12 Battery Subassembly ORUs (6 batteries) that provide station power during eclipse periods. This paper will discuss the battery performance data after two and a half years of cycling.

Dalton, Penni↗

International Space Station Nickel-Hydrogen Battery On-Orbit Performance

International Space Station (ISS) Electric Power System (EPS) utilizes Nickel-Hydrogen (Ni-H2) batteries as part of its power system to store electrical energy. The batteries are charged during insolation and discharged during eclipse. The batteries are designed to operate at a 35 percent depth of discharge (DOD) maximum during normal operation. Thirty-eight individual pressure vessel (IPV) Ni-H2 battery cells are series-connected and packaged in an Orbital Replacement Unit (ORU). Two ORUs are series-connected utilizing a total of 76 cells to form one battery. The ISS is the first application for low earth orbit (LEO) cycling of this quantity of series-connected cells. The P6 (Port) Integrated Equipment Assembly (IEA) containing the initial ISS high-power components was successfully launched on November 30, 2000. The IEA contains 12 Battery Subassembly ORUs (6 batteries) that provide station power during eclipse periods. This paper will discuss the battery performance data after eighteen months of cycling.

Dalton, Penni↗

Metal Hydride Compression

Conventional hydrogen compressors often contribute over half of the cost of hydrogen stations, have poor reliability, and have insufficient flow rates for a mature fuel cell vehicle market. Fatigue associated with their moving parts including cracking of diaphragms and failure of seals leads to failure in conventional compressors, which is exacerbated by the repeated starts and stops expected at fueling stations. Furthermore, the conventional lubrication of these compressors with oil is generally unacceptable at fueling stations due to potential fuel contamination. MH technology offers a very good alternative to both conventional (mechanical) and newly developed (electrochemical, ionic liquid pistons) methods of hydrogen compression. Advantages of MH compression include simplicity in design and operation, absence of moving parts, compactness, safety and reliability, and the possibility to utilize waste industrial heat to power the compressor. Beyond conventional H 2 supply via pipelines or tanker trucks, another attractive scenario is the on-site generation and delivery of pure H 2 at pressure (> 875 bar) for refueling vehicles at electrolysis, wind, or solar H 2 production facilities in distributed locations that are too remote or widely distributed for cost effective bulk transport. MH hydrogen compression utilizes a reversible heat-driven interaction of a hydride-forming metal alloy with hydrogen gas to form the MH phase and is a promising process for hydrogen energy applications. To deliver hydrogen continuously, each stage of the compressor must consist of multiple MH beds with synchronized hydrogenation & dehydrogenation cycles. Multistage pressurization allows achievement of greater compression ratios using reduced temperature swings compared to single stage compressors. The objectives of this project are to investigate and demonstrate on a laboratory scale a twostage MH hydrogen gas compressor with a feed pressure of >100 bar and a delivery pressure > 875 bar of high purity H 2 gas using the scheme shown in Figure 1. Progress to date includes the selection of metal hydrides for each compressor stage based on experimental characterization of their thermodynamics, kinetics, and hydrogen capacities for optimal performance with respect to energy requirements and efficiency. Additionally, final bed designs have been completed based on trade studies and all components have been ordered. The prototype two-stage compressor will be fabricated, assembled, and experimentally evaluated in FY19.

08 HYDROGEN↗

Metal Hydride Compression

Conventional hydrogen compressors often contribute over half of the cost of hydrogen stations, have poor reliability, and have insufficient flow rates for a mature FCEV market. Fatigue associated with their moving parts including cracking of diaphragms and failure of seal leads to failure in conventional compressors, which is exacerbated by the repeated starts and stops expected at fueling stations. Furthermore, the conventional lubrication of these compressors with oil is generally unacceptable at fueling stations due to potential fuel contamination. Metal hydride (MH) technology offers a very good alternative to both conventional (mechanical) and newly developed (electrochemical, ionic liquid pistons) methods of hydrogen compression. Advantages of MH compression include simplicity in design and operation, absence of moving parts, compactness, safety and reliability, and the possibility to utilize waste industrial heat to power the compressor. Beyond conventional H2 supplies of pipelines or tanker trucks, another attractive scenario is the on-site generating, pressuring and delivering pure H 2 at pressure (≥ 875 bar) for refueling vehicles at electrolysis, wind, or solar generating production facilities in distributed locations that are too remote or widely distributed for cost effective bulk transport. MH hydrogen compression utilizes a reversible heat-driven interaction of a hydride-forming metal alloy with hydrogen gas to form the MH phase and is a promising process for hydrogen energy applications [1,2]. To deliver hydrogen continuously, each stage of the compressor must consist of multiple MH beds with synchronized hydrogenation & dehydrogenation cycles. Multistage pressurization allows achievement of greater compression ratios using reduced temperature swings compared to single stage compressors. The objectives of this project are to investigate and demonstrate on a laboratory scale a two-stage MH hydrogen (H 2 ) gas compressor with a feed pressure of >50 bar and a delivery pressure ≥ 875 bar of high purity H 2 gas using the scheme shown in Figure 1. Progress to date includes the selection of two candidate metal hydrides for each compressor stage, supplier engagement and synthesis of small samples, and the beginning of in-depth characterization of their thermodynamics, kinetics, and hydrogen capacities for optimal performance with respect to energy requirements and efficiency. Additionally, bed design trade studies are underway and will be finalized in FY18. Subsequently, the prototype two-stage compressor will be fabricated, assembled and experimentally evaluated in FY19.

08 HYDROGEN↗

Fuel Cell Stack Model for Real-Time Simulation of Grid-Connected Applications

Fuel cell stacks coupled with electrolyzers and hydrogen storage sites can be a promising category of distributed energy resources for both grid-connected and stand-alone power systems. However, because of high costs, at-scale hardware testing of fuel cell stacks for grid-connected applications is not economically viable at present. A model-based system that can accurately captures the steady-state and dynamic response of fuel cell stacks over long time periods (hours), is needed. This paper demonstrate a real-time electromagnetic transient model of a megawatt-scale, grid-connected proton exchange membrane fuel cell stack, coupled with a mass-based hydrogen storage system. This model can emulate the electrical steady-state and dynamic response of grid-connected fuel cell stacks. We validate the model using the response of commercial hardware fuel cell stacks and analytical models in the literature - using a digital real-time simulator (RSCAD). The proposed real-time model is then used to simulate cases spanning different time horizons and to design controller-hardware-in-the-loop experiments to evaluate controllers for hydrogen stations.

activation potential↗

Administration of H-Prize Final Report

The Hydrogen Education Foundation (HEF) administrated the H-Prize, a program authorized by Congress in 2007 to incentivize innovative technology development in the hydrogen and fuel cell sector. Under this authorization, DOE allocated $\$$1 million for one Prize. DOE selected HEF competitively in 2008 to administer the competition, perform fundraising activities to develop a robust prize program, and perform marketing and communications, from 2008 to 2017. HEF administered two H-Prize competitions for DOE, the first for development of hydrogen storage materials for use on board fuel cell electric vehicles, and the second for a home or community sized hydrogen fueling system. HEF marketed the competitions through industry channels, at industry meetings, a specialized website and press releases to obtain entrants to the competitions. HEF provided assistance to the DOE for development of the judging criteria, and administered the judging and the final decision processes. In parallel, HEF sought additional prize funding from industry and foundations to expand the number of potential competitions and the amount of future prizes, consistent with the Congressional authorization of H-Prize. The first prize sought the development of a hydrogen storage material that could meet DOE’s criteria for onboard storage. This competition did not achieve any entrants that met the requirements. The second prize was for a small-scale hydrogen fueling system. The $\$$1 million prize was awarded to the industry consortium SimpleFuel for their home hydrogen refueling system. HEF executed a three-pronged strategy for raising funds to expand the competitions through private (non-public) funding – corporate contributions consistent with company interests; foundation contributions consistent with their goals; and individual contributions, principally through the United Way Campaigns. For a variety of reasons, HEF did not achieve the envisioned fundraising goals, which made it difficult to achieve the excitement originally envisioned by the H-Prize Congressional authors. Originally planned as a multi-year, multi-prize competition, an expansion of H-Prize to additional competitions with potentially larger awards did not happen. Prize competitions remain a useful way to stimulate technological innovation by researchers and product developers. Creating excitement through topic selection and harmony with important and achievable energy goals that inspire both applicants and their development work, and prize funders, is key.

08 HYDROGEN↗

A liquid hydrogen tube moderator arrangement for SNS second target station

Liquid hydrogen filled tubes arranged in a triangular shape surrounded by light-water premoderators were investigated as cold moderators coupled to a neutron production zone of a tungsten target fed by a 1.3 GeV proton beam in a short-pulse mode. A moderator concept optimized for the tube length, premoderator thickness, and target position was found to deliver the highest pulse-integrated neutron brightness suitable to send cold neutron beams for neutron scattering instrumentation geared toward medium resolution and small samples. Reducing the tube diameter from 50 to 10 mm boosts the cold neutron brightness (E < 10 meV) by a factor of 2.25, also with enhancements seen by downsizing the height of cylindrical moderators in earlier studies. Attempts were made to characterize this novel moderator system with regard to pulse shapes, local brightness distribution, and angular distribution of emission at the neutron emission port.

Gallmeier, Franz X. (ORCID:0000000171500764)↗

Evaluating national hydrogen refueling infrastructure requirement and economic competitiveness of fuel cell electric long-haul trucks

This study explored the national hydrogen refueling infrastructure requirement along major United States (US) interstate highway corridors to support the deployment of fuel cell electric trucks (FCETs) for the national long-haul trucking fleet. Given the long-haul trucking shipment demand in 2025 projected by the Freight Analysis Framework, locations and capacities of hydrogen stations were identified for inter-zone freight flows, and the total daily refueling demand was estimated for intra-zone flows for each FAF zone. Based on the infrastructure deployment results, we conducted an economic feasibility analysis of FCETs by evaluating the total ownership cost. We found that when the FCET penetration is relatively high (e.g., 10% penetration), FCETs become more competitive in terms of fuel cost and idling cost and could be economic viable if the incremental vehicle cost is reduced to meet the near-term FCET technology cost targets and the liquefaction cost is reduced to an optimal case. We also observed that the station cost depends on regional factors, particularly regional demand, which is used to determine station capacity. Thus, one possible strategy for station roll-out is to have early investment in target regions where station costs are expected to be relatively low such as the Pacific and West South Central regions.

33 ADVANCED PROPULSION SYSTEMS↗

Assessment of Heavy-Duty Fueling Methods and Components

Building on the successful commissioning and demonstration of NREL's heavy-duty (HD) fast flow research facility under the Innovating Hydrogen Station's Project, researchers advanced R&D activities to the next phase under a new project titled, Assessment of Heavy-Duty Fueling Methods and Components. This Cooperative Research and Development Agreement (CRADA) is led by NREL in partnership with NextEnergy, Argonne National Laboratory, and Chevron with NextEnergy representing a larger group of industry partners that includes AirLiquide, Hyundai, Nel, Nikola, Shell, and Toyota. The CRADA seeks to develop a comprehensive assessment of HD fuel cell electric vehicle fueling protocols and fueling hardware to understand the effects of fueling protocol architectures on station design, vehicle design, functional safety requirements, and the implications on the total cost of ownership (TCO) and techno economic assessment (TEA).

class 8 truck↗

Hydrogen Component Leak Rate Quantification for System Risk and Reliability Assessment through QRA and PHM Frameworks: Preprint

The National Renewable Energy Laboratory's (NREL) Hydrogen Safety Research and Development (HSR&D) program in collaboration with the University of Maryland's Systems Risk and Reliability Analysis Laboratory (SyRRA) are working to improve reliability and reduce risk in hydrogen systems. This approach strives to use quantitative data on component leaks and failures, together with Prognosis and Health Management (PHM), and Quantitative Risk Assessment (QRA) to identify at-risk components, reduce component failures and downtime, and predict when components require maintenance. Hydrogen component failures increase facility maintenance cost, facility downtime, and reduce public acceptance of hydrogen technologies, ultimately increasing facility size and cost because of potentially overly conservative requirements. Leaks are a predominant failure mode for hydrogen components. However, uncertainties in the amount of hydrogen emitted from leaking components and the frequency of those failure events limit the understanding of the risks that they present under real-world operational conditions. NREL has deployed a test fixture, the Leak Rate Quantification Apparatus (LRQA), to quantify the mass flow rate of leaking gases from medium and high-pressure components that have failed while in service. Quantitative hydrogen leak rate data from this system could ultimately be used to better inform risk assessment and Regulation Codes and Standards (RCS). Parallel activity explores the use of PHM and QRA techniques to assess and reduce risk, thereby improving safety and reliability of hydrogen systems. The results of QRAs could further provide a systematic and science-based foundation for the design and implementation of RCS, as in the latest versions of the NFPA 2 code for gaseous hydrogen stations. Alternatively, data-driven techniques of PHM could provide new damage diagnosis and health-state prognosis tools. This research will help end users, station owners and operators, and regulatory bodies move towards risk-informed preventative maintenance versus emergency corrective maintenance, reducing cost and improving reliability. Predictive modelling of failures could improve safety and affect RCS requirements such as setback distances at liquid refuelling sites. The combination of leak rate quantification research, PHM, and QRA can lead to better informed models enabling data-based decision to be made for hydrogen system safety improvements.

codes and standards↗

International Space Station Nickel-Hydrogen Battery Start-Up and Initial Performance

International Space Station (ISS) Electric Power System (EPS) utilizes Nickel-Hydrogen (Ni-H2) batteries as part of its power system to store electrical energy. The batteries are charged during insolation and discharged during eclipse. The batteries are designed to operate at a 35% depth of discharge (DOD) maximum during normal operation. Thirty eight individual pressure vessel (IPV) Ni-H2 battery cells are series-connected and packaged in an Orbital Replacement Unit (ORU). Two ORUs are series-connected utilizing a total of 76 cells, to form one battery. The ISS is the first application for low earth orbit (LEO) cycling of this quantity of series-connected cells. The P6 Integrated Equipment Assembly (IEA) containing the initial ISS high-power components was successfully launched on November 30, 2000. The IEA contains 12 Battery Subassembly ORUs (6 batteries) that provide station power during eclipse periods. This paper will describe the battery hardware configuration, operation, and role in providing power to the main power system of the ISS. We will also discuss initial battery start-up and performance data.

Cohen, Fred↗

Hyundai FCEV Testing, Data Collection and Validation Fleet

This report summarizes the work conducted under Award Number DE-EE0005970 by Hyundai America Technical Center, Inc. (HATCI) to demonstrate and validate Hyundai Tucson Fuel Cell Electric Vehicles (FCEV) reliability in real world applications. HATCI operated 10 light-duty FCEVs throughout various geographical regions in United States to collect and submit vehicle performance durability data over 5 years. HATCI introduced FCEVs in two phases. First phase deployed 5 vehicles in Southern California to study customer real world usage and prove its reliability under commute and fleet driving pattern from 2013 to 2015. As the hydrogen station infrastructure expanded its network, second phase deployed and operated 5 additional vehicles under various climate zones (hot, cold, high altitude) and validated fuel cell performance from 2016 to 2017. California Air Resources Board (Sacramento, CA), California Fuel Cell Partnership, US Department of Energy (Washington DC), Hyundai Motor America, HATCI (Ann Arbor, Michigan), National Renewable Energy Laboratory (Golden, CO), and South Coast Air Quality Management District were the fleet operators. Four different stack degradation mechanism issues were addressed through validation project: fuel cell stack dry-out, flooding, cathode oxidation, and platinum dissolution. By developing counter-measures to each fuel cell stack degradation mechanism through performance validation fleet, Hyundai was able to successfully develop the next generation fuel cell vehicle NEXO, with longest range, large cost reduction, and best fuel cell powertrain warranty in its class (100,000 miles, 10 years warranty).