Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HVAC controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Beneficial Integration of Energy Storage and Load Management with Photovoltaic (PV)

In recent years, a number of industry activities have aimed at addressing the integration challenges posed by the variability and uncertainty of higher penetration of renewable generation sources, like solar photovoltaic (PV) – one of the key objectives of the Sustainable and Holistic Integration of Energy Storage and Solar PV (SHINES) program launched by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). This EPRI led Beneficial Integration of Energy Storge, and Load Management with PV project aimed to design, develop, and demonstrate end-to-end distributed energy resource (DER) integration solution to build on these activities. EPRI led project team designed and implemented a local controller that uses model predictive control (MPC) algorithm to optimally manage DERs on site by planning for a receding horizon while executing the control settings for the first step of its plan. The team has also developed a system controller to interface with the local controller to demonstrate the hierarchical control and how it can leverage DER capabilities to address challenges like over voltage and thermal limit violations which typically limits the DER hosting capacity of distribution feeders. Team has demonstrated how the local controller with optimization algorithm can effectively manage controllable loads like HVAC, water heater, and pool pumps to allow for greater integration of PV with relatively smaller energy storage system requirements. Optimal utilization of the load control can also reduce the depth of discharge of batteries to meet grid export/import limit from behind-the-meter (BTM) DERs. Proper utilization of DER capabilities via local control intelligence, like the one developed and demonstrated in this project can help the industry to address integration challenges of higher penetration of solar PV in economically efficient manner. This can help to accelerate deployment of clean renewable energy systems at lower societal cost.

14 SOLAR ENERGY↗

Demand Flexibility Controls Library using Semantics (DFLEXLIBS) v0.1

DFLEXLIBS is a library/repository of HVAC-based demand flexibility control applications developed using Python. The library is based on portable control applications that exclusively contain control logic and are abstract to building details, such as point names and communication protocols. The library leverages semantic models and control platform-oriented interfaces to configure and run the controls in specific buildings. To date, the library contains two applications and two interfaces (for BOPTEST and VOLTTRON) and has been demonstrated in five heterogeneous buildings.

Paul, Lazlo↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗

Evaluating Thermostats’ Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Thermostats play a crucial role in energy consumption, user control, and occupant comfort by serving as the interface between the heating, ventilation, and air conditioning (HVAC) system and the building's occupants. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on or off. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different thermostats, tested with a residential heat pump, aiming to identify variations in their deadband settings and implications for energy usage and management. The experimental study was conducted using a HVAC hardware-in-the-loop (HIL) system that allows thermostats to be connected with physical HVAC equipment, driven by conditions in a simulated residential building. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats cycle differently based on their deadband settings. The findings offer valuable insights into how thermostat deadband affects comfort and energy use, as well as the cycling frequency of a heat pump.

Ramaraj, Sugirdhalakshmi [National Renewable Energ↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Cluster analysis of occupancy schedules in residential buildings in the United States

The energy performance of residential buildings significantly depends on the building occupants’ behavior, which can be highly variable. When the heating, ventilation and air conditioning (HVAC) system is controlled based on the presence or absence of occupants in a building, occupant behavior is of even further importance to its energy performance. In current practice, building energy simulation tools generally use a single occupancy profile to represent the building’s occupancy schedule, the schedule of which is considered to be the same, regardless of the type of household being modeled. Thus, there is significant potential for improvement to allow for more flexibility and accuracy in calculation of occupancy. The objective of this study is to assess the variations in the typical types of occupancy schedules followed by the U.S. population using cluster analysis. American Time Use Survey data, which statically represents the overall U.S. population’s activities, across 12 years (2006–2017), is used. The ATUS data is segregated into smaller groups based on age and weekday/weekend, then divided into activities that are considered “at home” and “away from home”, which are mapped to the presence or non-presence of occupants in the home. Cluster analysis is then used to identify common types of occupancy schedule patterns for each age group. Three main types of patterns are obtained from cluster analysis for each age group, which together represent approximately 88% of people in the United States. The output of the cluster analysis is further analyzed to evaluate the variation in characteristics, including the number of times leaving home, time of day when leaving the home, and the timespan of absence from the home. The results of this study provide detailed insights on how typical occupants in the United States spend their time in residential spaces which can be used to create occupancy profiles for residential buildings. Finally, these occupancy profiles could be utilized inform an assessment of the energy use impact of occupancy-based controls of energy consuming systems and technologies.

42 ENGINEERING↗

Good practices for documenting AI-based studies on energy and buildings

Artificial intelligence has transformed building science research over the past decade, with applications spanning energy modeling, energy prediction, HVAC optimization and controls, fault detection, and occupancy modeling. However, many studies lack adequate documentation of datasets, algorithms, training procedures, and validation methods. Building science research faces additional challenges including inconsistent evaluation metrics, limited generalizability across building types, climates, and significant gaps between experimental studies and deployed systems. This communication provides practical guidance for good practices in documenting and publishing AI-based research following established standards from the computer science and machine learning communities. By adopting frameworks such as Datasheets for Datasets, Model Cards, and standardized reproducibility checklists, researchers can ensure their work meets the rigorous documentation standards necessary for reproducible, comparable, and impactful building science research.

Hong, Tianzhen [Lawrence Berkeley National Laborat↗

High-Fidelity Building Emulator

This dataset provides high-fidelity time series data for an emulated commercial office building sited in the Chicago, IL area during a Typical Meteorological Year (TMY). This dataset consists of air-side HVAC measurements and control inputs, and it includes normal operations as well as various implemented faults (with associated ground truth measurements) implemented on selected days. This data could be used to quantify and compare the impacts of different faults, and it could also be used as training or validation data for machine learning algorithms (e.g., reduced-order modelling, fault detection and diagnosis).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Saving Quantification on Ductless Heat Pump (DHP) in Existing Homes

In residential retrofit applications, ductless mini-split heat pumps (DHP) are often reported to have high-energy savings potential, depending on the system they are supplementing or replacing. However, recently, there have been a number of utility studies and analyses indicating these energy savings are not being achieved when the existing system is left in place for backup heating or air conditioning. The Pacific Northwest National Laboratory conducted a three-phase project to help determine which control strategies would have the most energy savings impact in various climate zones around the United States. The first phase developed the standalone simulation model for the PNNL Lab Homes and investigated the energy-saving potential from different control strategies and HVAC system configurations. The second phase focused on conducting experiments in the PNNL Lab Homes, which tested the most promising solutions that were modeled in the first phase. The third phase used the field data to calibrate the simulation model and then extrapolated the results to different climate locations and different building sizes. This report focuses on the third phase of the study, including five major parts: model calibration, parametric model setup, results, a sensitivity analysis of air leakage rate, and conclusions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An analysis of the hybrid internal mass modeling approach in EnergyPlus

Accurate simulation of building system dynamics is particularly important for understanding building energy flexibility. Among all dynamics in a building, a zone temperature’s variation is especially important, as it significantly affects a building’s electricity load profile when its heating, ventilating, and air conditioning (HVAC) system is controlled with on/off cycles or setpoint reset strategies. To accurately simulate a zone temperature’s dynamics, internal mass needs to be modeled carefully. In this paper, we compare the two internal mass modeling approaches provided by EnergyPlus, i.e., internal mass object and zone air capacitance multiplier, to better understand their impacts on zone temperature simulation. Real building zone temperature dynamic data from small- and medium-sized office buildings are analyzed and compared with simulated data. In particular, we illustrate the effectiveness of a hybrid method of the two EnergyPlus modeling approaches, which yields more realistic zone temperature dynamics, especially when the zone is conditioned with heat pump systems with on/off cycling.

Chen, Zhelun↗

Ecosystem-Level Biomimicry for the Built Environment: Adopting Systems Ecology Principles for the Control of Heterogeneous Energy Systems

This paper presents, to our knowledge, the first system-level engineering study to bio-mimic the cybernetics and flow dynamics of energy resources in natural ecosystems for the control of heterogeneous energy infrastructures in the built environment. To this end, we introduce a novel Biomimetic Pulsing State (BPS) control that functionally mimics mature ecosystems. A preliminary Modelica-based case study features a single-family residential building with electrical and HVAC subsystems. The BPS control objective is to minimize the energy exchange between the building and the grid for the purposes of future self-supporting buildings and grid stability. The building contains PV, a wind turbine, a battery storage system, and a fan coil/heat pump HVAC system served by an ambient district energy network. Evaluating the control performance (BPS vs. constant setpoint) over several renewable energy scenarios (net importer, net zero, net exporter), simulation results show how the building's HVAC system can dynamically adjust its electrical load and temperatures to the electrical system's net energy status in real-time with BPS control. As a net importer, the heat pump consumed 29% less energy and its peak power reduced by 15% with BPS control compared to the constant setpoint case, with the zone air temperature 1 degree C lower on average. As a net exporter, the heat pump effectively consumed the same energy, but the peak power increased by 34% with BPS control, while the zone air temperature was 1 degree C higher when renewable energy was abundant, preheating the home. BPS and constant setpoint control produced comparable results under a net zero scenario. While further evaluation is essential, BPS control may help communities meet their sustainability and resiliency targets as they transition towards fully distributed and renewable energy grids.

biomimicry↗

IBPSA Project 2 BOPTEST: An update on the test cases available in the framework for testing advanced control strategies in buildings

Project 2 develops software infrastructure, test cases, and extensions for the Building Optimization Testing Framework (BOPTEST) to address the expanding needs of building and urban energy system controls through open international collaboration. This paper provides an overview of the new test cases available as of BOPTEST version 0.7.1. Each test case is developed using open-source Modelica libraries and Spawn of EnergyPlus, enabling the creation of high-fidelity building models that incorporate envelope dynamics, Heating Ventilation and Air Conditioning (HVAC) systems, and explicit control representations. Currently, eight test cases are available, with five additional cases under development. These test cases cover a wide range of climates, building types, and HVAC systems. This paper compiles and summarizes test case descriptions, cites original manuscripts that developed them for a more detailed description, and reports baseline control performance metrics. Furthermore, two example applications are presented: one illustrating different levels of control, from supervisory to low-level, and another demonstrating how Model Predictive Control (MPC) solutions must be adapted from continuous to integer to control some building actuators.

Zanetti, Ettore↗