Bridging Gaps in Simulation Analysis through a General Purpose, Bidirectional Steering Interface with Ascent
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
We introduce a novel black hole mass function that realistically models the physics of pair-instability supernovae with a minimal number of parameters. Applying this to all events in the LIGO-Virgo Gravitational-Wave Transient Catalog 2 (GWTC-2), we detect a peak at M BHMG = 46$^{+17}_{-6}$ M ⊙ . Repeating the analysis without the black holes from the event GW190521, we find this feature at M BHMG =54± 6 M ⊙ . These results establish the edge of the anticipated "black hole mass gap" at a value compatible with the expectation from standard stellar structure theory. The mass gap manifests itself as a discontinuity in the mass function and is populated by a distinct, less-abundant population of higher-mass black holes. We find that the primary black hole population scales with power-law index -1.95 ± 0.51 (-1.97 ± 0.44) with (without) GW190521, consistent with models of star formation. Using Bayesian techniques, we establish that our mass function fits a new catalog of black hole masses approximately as well as pre-existing phenomenological mass functions. We also remark on the implications of these results for constraining or discovering new phenomena in nuclear and particle physics.
Electric utilities conduct planning annually to ensure their distribution system meets technical standards, policies, and regulations; addresses forecasted grid conditions; satisfies customer needs; and advances utility priorities. The plan identifies grid deficiencies, analyzes potential solutions, and prioritizes capital investments and other expenditures. About 20 U.S. states and jurisdictions require regulated utilities to file some type of distribution system plan with the public utility commission for review. Requirements for sharing distribution system data and analyses vary widely, from few specific requirements to a detailed list of information that must be provided. While utilities conduct extensive analysis to develop distribution system plans, in most jurisdictions regulators and stakeholders do not know what data are available and how the utility uses the data in planning and investing. This report aims to bridge the gap by increasing understanding of the types of data and analyses utilities employ to develop distribution system plans and how the information affects their decision-making. The report describes information that states and stakeholders can ask for related to 11 data categories: -Forecasting loads and distributed energy resources (DERs) -Scenario analysis -Worst-performing circuits -Asset management strategy -Hosting capacity analysis -Value of DERs -Grid needs assessment -Cost-effectiveness framework for investments -Distribution system investment strategy and implementation -Geotargeted programs -Non-wires alternatives procurements.
The increased use of personal vehicles presents environmental challenges, prompting the exploration of public transportation as an affordable, eco-friendly alternative. However, obstacles like fixed schedules, limited routes, and extended travel times impede widespread adoption. This study investigates the temporal evolution of spatial inequality in the travel time gap between public transportation and personal vehicles, reflecting disparities across states and time periods. Analyzing Census Transportation Planning Program data for six northeastern states in 2010 and 2016 reveals no significant increase in the travel time gap, but notable growth in inequality in a few urban and disadvantaged communities. Comprehending these trends is vital for fostering equitable advancements in transportation infrastructure and enhancing public transportation competitiveness.
Microreactor is a type of nuclear reactor that is intended to produce thermal energy from the micro and integrated design. Among various microreactor roadmaps, microreactor with heat pipes is one of the promising designs that under active development. At Idaho National Laboratory (INL) and supported by the Department of Energy (DOE) Microreactor Program (MRP), a Single Primary Heat Extraction and Removal Emulator (SPHERE) was developed. The main purpose of SPHRE is to understand thermal performance of heat pipe in the conjunction of heat source without using nuclear material. The heat pipe used in the SPHERE has sodium as a working fluid, with Argon gas in the vapor region, thus this heat pipe is variable conductance heat pipe (VCHP). The volume of non-condensable gas changes with power and elapsed time, so the area covered by non-condensable gas changes. This gives an effect that passively controls the cooling capability of condenser section. This preliminary experiment was intended to perform a gap conductance experiment that reveals heat transfer characteristics of gas at the gap around the heat pipe. However, there are not many experimental data that deals with heat transfer of the gas at the gap around heat pipe. In this research, the preliminary experimental result regarding to the heat pipe performance with different composition of gas at the gap, level of power is presented. The experimental data will be used for the validation study of SOCKEYE as a future plan.
A closed-cycle, three-dimensional (3D) computational fluid dynamics (CFD) analysis campaign was conducted to evaluate the performance of using spark plugs to assist gasoline compression ignition (GCI) combustion during cold idle operations. A conventional spark plug using single-sided J-strap design was put at a location on the cylinder head to facilitate spray-guided spark assistance. Ignition was modeled with an L-type energy distribution to depict the breakdown and the arc-to-glow phases during the energy discharge process. Several key design parameters were investigated, including injector clocking, number of nozzle holes, spray inclusion angle, number of fuel injections, fuel split ratio, and fuel injection timings. The study emphasized the region around the spark gap, focusing on flame kernel formation and development and local equivalence ratio distribution. Flame kernel development and the ignition process were found to correlate strongly with the fuel stratification and the flow velocity near the spark gap. The analysis results showed that the flame kernel development followed the direction of the local flow field. In addition, the local fuel stratification notably influenced early-stage flame kernel development due to varying injection spray patterns and the fuel injection strategies. Among these design parameters, the number of nozzle holes and fuel injection timing had the most significant effects on the engine combustion performance.
Abstract We present an urban science framework to characterize phone users’ exposure to different street context types based on network science, geographical information systems (GIS), daily individual trajectories, and street imagery. We consider street context as the inferred usage of the street, based on its buildings and construction, categorized in nine possible labels. The labels define whether the street is residential, commercial or downtown, throughway or not, and other special categories. We apply the analysis to the City of Boston, considering daily trajectories synthetically generated with a model based on call detail records (CDR) and images from Google Street View. Images are categorized both manually and using artificial intelligence (AI). We focus on the city’s four main racial/ethnic demographic groups (White, Black, Hispanic and Asian), aiming to characterize the differences in what these groups of people see during their daily activities. Based on daily trajectories, we reconstruct most common paths over the street network. We use street demand (number of times a street is included in a trajectory) to detect each group’s most relevant streets and regions. Based on their street demand, we measure the street context distribution for each group. The inclusion of images allows us to quantitatively measure the prevalence of each context and points to qualitative differences on where that context takes place. Other AI methodologies can further exploit these differences. This approach presents the building blocks to further studies that relate mobile devices’ dynamic records with the differences in urban exposure by demographic groups. The addition of AI-based image analysis to street demand can power up the capabilities of urban planning methodologies, compare multiple cities under a unified framework, and reduce the crudeness of GIS-only mobility analysis. Shortening the gap between big data-driven analysis and traditional human classification analysis can help build smarter and more equal cities while reducing the efforts necessary to study a city’s characteristics.
We present a novel method for handling steady-state heat fluxes incident on the main wall of pilot plant-scale magnetic fusion devices, based on the utilization of protection limiters in the far scrape-off layer (SOL). This method helps avoid large plasma-wall gaps, without excessively compromising blanket performance. We present an optimization algorithm for determining the appropriate size and scale of these protection limiters given (1) probability distributions of SOL plasma parameters and (2) assumed risk tolerance. As part of this optimization, we have developed an analytic description of parallel heat fluxes across limiter shadows, and an objective cost function (the ‘Far-SOL Marginal Cost’) to quantify the impact that different main-wall thermal management design choices have on reactor capital cost. Applying the model to a midscale fusion pilot plant concept shows that making use of far-SOL protection limiters can reduce capital costs on the order of $500 M, relative to naively increasing the plasma-wall gap. Our analysis demonstrates that the far-SOL power decay length is the highest-leverage plasma assumption for thermal loading of the first wall, and the primary cost driver for main wall thermal management. The relative cost efficiency of protection limiters increases as assumptions on the far-SOL heat flux become more pessimistic. The concepts described in this paper motivate the further development of far-SOL protection limiters as part of larger efforts to design economical core-edge-wall compatible solutions for a fusion pilot plant.
Nine dyads composed of bacteriochlorins were prepared to investigate excited-state energy transfer (FRET) processes.
Abstract not provided
Abstract Using ground state density functional theory (DFT) and implementing an occupation-constrained DFT (occ-DFT) for self-consistent excited state calculations, we decipher the electronic structure of the Mn dopant and other 3 d defects in GaN across the band gap. Our analysis, validated with broad agreement with defect levels (ground-state calculations) and photoluminescence data (excited-state calculations), mandates reinterpretation and reassignment of 3 d defect data in GaN. The Mn Ga defect is determined to span stable charge states from (1−) in n -type GaN through (2+) in p -type GaN. The Mn(2+) is predicted to be a d 2 ground state spin triplet defect with a singlet excited state, isoelectronic with the defect associated with the 1.19 eV photoluminescence in n -type GaN. The combined analysis of defect levels and excited states invites reassessment of all d 2 -capable dopants in GaN. We demonstrate that the 1.19 eV defect, a candidate defect for optically controlled quantum applications, cannot be the Cr(1+) assumed in literature and instead must be the V(0). The combined ground-state/excited-state DFT analysis is shown to be able to chemically fingerprint defects.
Cu 3 Sb is a known copper-rich phase in the Cu–Sb binary phase diagram. It is reported to be dimorphic, with a low-temperature form adopting the orthorhombic Cu 3 Ti structure type (space group Pmmn , No. 59). The high-temperature form crystallizes in the cubic space group F m 3 - m $Fm‾{3}m$ (No. 225), and is isostructural with BiF 3 . Neither polymorph has been carefully characterized to date, with both structures being assigned to the respective structure type, but never refined. With this study, we provide structural evidence, based on single-crystal and powder X-ray diffraction data that the low-temperature orthorhombic phase exists with a significant amount of defects on one of the Cu-sites. As a result, its composition is not Cu 3 Sb, but rather Cu 3– δ Sb ( δ = 0.13(1)). The cubic form could not be accessed as a part of this study, but another Cu-rich phase, Cu 3 Sb ≈0.8 In ≈0.2 , was also identified. It adopts the hexagonal Ni 3 Sn structure type (space group P 6 3 / mmc , No. 194) and represents an In-substituted variant of a hitherto unknown structural modification of Cu 3 Sb. Whether the latter can exist as a binary phase, or what is the minimum amount of In inclusions needed to stabilize it remains to be determined. Measurements of the thermopower of Cu 3– δ Sb ( δ = 0.13(1)) were conducted in the range of 300–600 K and demonstrated a maximum value of ca. 50 μV/K at 600 K, indicative of a p -type transport mechanism. Electrical resistivity measurements for the same sample confirmed that it exhibits metallic-like behavior, with a room temperature value of 0.43 mΩ cm. Electronic structure calculations show the absence of a band gap. Thermal analysis was utilized to ascertain the congruent melting of both phases.
The project team of Southwest Research Institute ® (SwRI ® ), Malta Inc. (Malta), and Luminant Generation Company LLC (Luminant) completed a feasibility study for the integration of a 100-MW, 10-hour (1000-MWh) Malta Pumped Heat Energy Storage (MPHES) system with multiple full-sized fossil-fired electricity generation units (EGU) in Luminant portfolio. MPHES is a long-duration, molten-salt-energy storage technology that uses turbomachinery and heat exchangers to transfer energy to a thermal storage media when charging, and removes the heat in a similar fashion when discharging. With high round trip efficiency (60-65%) and long lifespan (30+ years), MPHES provides economic benefits to the fossil-asset owners that can be scaled to integrate with assets across their portfolio. This technology uses hardware components, workforce personnel, and skillsets similar to those used by fossil EGUs, allowing for synergy when co-locating the two technologies. Luminant has approximately 39,000 megawatts of generation across 12 states, operating in six of the seven competitive markets in the U.S. and powered by a diverse portfolio of natural gas, nuclear, coal, and solar facilities. The DeCordova plant in Granbury, Texas, a simple cycle natural gas peaker power plant, was used as the fossil-fired asset in this project. The local market in Granbury, Texas has many influences, including several nearby power plants, a Luminant-owned nuclear plant (Comanche Peak), and substantial wind energy, which causes both negative pricing at night and high market volatility. Reducing false starts of the DeCordova plant and better responding to market volatility would be an economic advantage. Luminant is currently integrating battery storage plant on site to begin addressing these challenges. Integrating long-duration storage, like MPHES, would expand this capability beyond one hour of storage and have the potential to greatly reduce the total number of gas turbine starts. The MPHES charging requirement could help offset the overnight operating costs of Comanche Peak, which cannot load follow, and the nearby Luminant-owned Wise County combined cycle plant that cycles too often. Following the assessment of Luminant’s ERCOT-based portfolio for integration compatibility with Malta’s PHES system and the project tasks of conceptual study, technoeconomic analysis, technology gap assessment, and commercialization plan, the project team effort has resulted in several key outcomes: (1) Identification of market trends in a high-wind penetration market outside a major metropolitan area; (2) Creation of a dispatching model for the MPHES system and the pairing of Li-ion battery with a gas turbine in a real time market; (3) Revenue and cost estimations for operating MPHES alongside a gas peaker plant with real dispatching considerations and comparison with variations in the Malta implementation, including doubling the storage capacity and using two discharge drivetrains; (4) Potential carbon emission reductions possible by replacing gas turbine operation with Malta PHES operation; and (5) Summary of literature-based future market predictions for Texas.
In July 2023, the Massachusetts Clean Energy Center (MassCEC) published an employment report titled “Powering the Future: A Massachusetts Clean Energy Workforce Needs Assessment.” This report was intended to support the State in meeting its 2030 decarbonization goals by identifying both existing workforce and training resources as well as gaps and barriers that need to be addressed in order to scale the State’s workforce to meet future demand. The following is a summary of the content that is relevant to Lawrence, MA. This was completed as part of the US Department of Energy’s Communities LEAP (Local Energy Action Program) Pilot supporting the Lawrence Stakeholders Coalition (LSC) led by Browning the Green Space in partnership with Groundwork Lawrence, All In Energy, and the City of Lawrence.
Presentation assessing the DER Cybersecurity Standards Landscape.
We present an experimental analysis of the change in the electric field enhancement factor with varying gap size and penetration depth (P.D) of cathode into anode for a coaxial vacuum gap, diagnosed using Fowler–Nordheim analysis and optical imaging via scanning electron microscope (SEM) and time integrated Digital single lens reflex camera (DSLR). Data were collected on the Coaxial Gap Breakdown Machine (240 A, 25 kV, 150 ns, 0.1 Hz). Experiments using five different gap sizes at nine different P.Ds are compared over runs comprising 50 shots for each case. The results show a strong link between enhancement factor and gap size, with P.D and surface topology. For large gap sizes, 150, 330, and 700 μm, the average enhancement factor value increases with increasing P.D. For smaller gap sizes, 50 and 100 μm, the average enhancement factor decreases with P.D. SEM imaging before and after plasma formation for each gap size allows for quantifying surface finish, microprotrusion growth, average blast diameter, and an estimation of the surface area breakdowns occupy. Time integrated DSLR imaging analysis of the gap at each shot allows for a determination of the distribution of breakdowns about the circumference of the gap for each case tested. Here, the Fowler–Nordheim analysis allows for a quantitative analysis of the surface roughness of all gap sizes tested. Results show that for large gap sizes, the gap geometry and increasing area of breakdown is the main cause for increasing average enhancement factor. For small gap sizes, the dominant driving factor for small average enhancement factors—that subsequently decrease with P.D—is significant changes in surface topology due to an increased number of breakdowns.
Here, the nature of the superconducting order parameter in Sr 2 RuO 4 has generated intense interest in recent years. Since the superconducting gap is very small, high-resolution methods such as scanning tunneling spectroscopy might be the best chance to directly resolve the gap symmetry. Recently, a Bogoliubov quasiparticle interference imaging (BQPI) experiment has suggested that the d x 2 –y 2 gap symmetry is appropriate for Sr 2 RuO 4 . In this work, we use a material-specific theoretical approach based onWannier functions of the surface of Sr 2 RuO 4 to calculate the continuum density of states as detected in scanning tunneling microscopy experiments. We examine several different proposed gap order parameters and calculate the expected BQPI pattern for each case. Comparing to the available experimental data, our results suggest that a s' + id xy gap order parameter is the most probable state, but the measured BQPI patterns still display features unaccounted for by the theory for any of the states currently under discussion.