Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GaSe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Observations of Greenhouse Gases as Climate Indicators

Humans have significantly altered the energy balance of the Earth’s climate system mainly not only by extracting and burning fossil fuels but also by altering the biosphere and using halocarbons. The 3rd US National Climate Assessment pointed to a need for a system of indicators of climate and global change based on long-term data that could be used to support assessments and this led to the development of the National Climate Indicators System (NCIS). Here we identify a representative set of key atmospheric indicators of changes in atmospheric radiative forcing due to greenhouse gases (GHGs), and we evaluate atmospheric composition measurements, including non-CO2GHGs for use as climate change indicators in support of the US National Climate Assessment. GHG abundances and their changes over time can provide valuable information on the success of climate mitigation policies, as well as insights into possible carbon-climate feedback processes that may ultimately affect the success of those policies. To ensure that reliable information for assessing GHG emission changes can be provided on policy-relevant scales, expanded observational efforts are needed. Furthermore, the ability to detect trends resulting from changing emissions requires a commitment to supporting long-term observations. Long-term measurements of greenhouse gases, aerosols, and clouds and related climate indicators used with a dimming/brightening index could provide a foundation for quantifying forcing and its attribution and reducing error in existing indicators that do not account for complicated cloud processes.

greenhouse gases↗

Noble Gases and Stable Isotopes Track the Origin and Early Evolution of the Venus Atmosphere

The composition the atmosphere of Venus results from the integration of many processes entering into play over the entire geological history of the planet. Determining the elemental abundances and isotopic ratios of noble gases (He, Ne, Ar, Kr, Xe) and stable isotopes (H, C, N, O, S) in the Venus atmosphere is a high priority scientific target since it could open a window on the origin and early evolution of the entire planet. This chapter provides an overview of the existing dataset on noble gases and stable isotopes in the Venus atmosphere. The current state of knowledge on the origin and early and long-term evolution of the Venus atmosphere deduced from this dataset is summarized. A list of persistent and new unsolved scientific questions stemming from recent studies of planetary atmospheres (Venus, Earth and Mars) are described. Important mission requirements pertaining to the measurement of volatile elements in the atmosphere of Venus as well as potential technical difficulties are outlined.

noble gases↗

THEORY OF TRANSPORT PROPERTIES OF GASES

Kinetic theory of transport properties of dilute gases, relating it to flames processes, noting assumptions of chapman-enksog theory, discussing real and dusty gases as well as rocket exhausts

FLAME↗

Calculation of infrared spectral transmittances of inhomogeneous gases

Calculation of spectral transmittance for a particular inhomogeneous gas path is made by combining known data on gases at constant temperature, pressure, and concentration. The spectral transmittances of the inhomogeneous plume gases is needed to calculate the heat radiated from the exhaust plume to the rocket base of a multiple engine rocket.

Huffaker, R. M.↗

Irradiated gases transferred without contamination or dilution

Vacuum chamber apparatus opens sealed canisters of irradiated gases and transfers the contents without contaminating the surrounding area, and without diluting or polluting the contained gases. The apparatus consists of the chamber, a valved piping manifold, and a special drill and sealed drilling access.

Bonn, J. L.↗

Transport phenomena in gases.

Nonequilibrium statistical mechanics of nonreacting gases, discussing transport phenomena in dilute and moderately dense gases

Curtiss, C. F.↗

Solubility of non-polar gases in electrolyte solutions

Solubility theory describes the effects of both concentration and temperature on solute activity coefficients. It predicts the salting-out effect and the decrease in solubility of non-polar gases with increased electrolyte concentration, and can be used to calculate heats of solution, entropies, and partial molal volumes of dissolved gases

Walker, R. L., Jr.↗

Nondispersive infrared analyzer for specific gases in complex mixtures

Analyzer identifies and measures particular diatomic or polyatomic gases in complex gas mixtures. Mixing of absorption effects on light energy passing through gases to photodetector produces a signal component that is related to the absorption caused by reference-gas component in unknown gas mixture.

Dimeff, J.↗

Remote control flare stack igniter for combustible gases

Device has been designed and developed for igniting nonrecoverable combustible gases and sustaining combustion of gases evolving from various gas vent stacks. Igniter is superior to existing systems because of simplicity of operation, low cost fabrication, installation, operational and maintainability features, and excellent reliability in all phases of required operations.

Ray, W. L.↗

Fe I oscillator strengths determined from anomalous dispersion of shock-heated gases.

Determination of Fe I oscillator strengths by the hook method on shock-heated gases. Within the given errors these values agree with oscillator strengths obtained by other methods, including wall-stabilized arc and shock-tube emission, the beam-foil technique, and delayed-coincidence measurements, except that the data reported in the present article tend to be somewhat higher. If it is assumed that no change occurs in atmospheric models, the authors' f-value scale would suggest a solar abundance at the lower limit of the recently published values - namely, log (A sub Fe/A sub H) + 12 = 7.4. This study demonstrates the effectiveness of the hook method for quantitative spectroscopy on shock-heated gases and points up its usefulness for gas diagnostics on optically thick lines.

Huber, M. C. E.↗

Improved fast response pressure gauge for shock reflection studies in ionized gases.

An improved design is presented for a fast response pressure gauge (0.1 microsec risetime) suitable for short duration measurements on the end wall of a shock tube. The design includes standard components to facilitate gauge construction, and it utilizes dual capacitive sensing elements together with a signal differencing scheme to permit use of the gauge in ionized gases. Pressure-time records obtained with the gauge are presented showing details of pressure profiles on the shock tube end wall for reflecting shock waves in ionized gases.

Hanson, R. K.↗

Thermal conductivity in vibrationally excited gases.

Comparisons between experimental and theoretical values of the thermal conductivity for a series of nonpolar polyatomic gases show large discrepancies at higher temperatures where the vibrational contribution becomes increasingly important. Examination of various theoretical approaches indicates that the discrepancies can be attributed to approximating the coefficient characterizing the diffusion of vibrational energy, D sub vib, by the self-diffusion coefficient. The present theories cannot accurately predict D sub vib, and its measurement is extremely difficult. Consequently, the approach adopted by the author is to obtain D sub vib by using experimental values of the thermal conductivity. An attempt is made to correlate these values of D sub vib with vibrational relaxation time, so that values of D sub vib can be obtained for all nonpolar polyatomic gases.

Ahtye, W. F.↗

Correlation of heat transfer for the zero pressure gradient hypersonic laminar boundary layer for several gases

A theoretical study of heat transfer for zero pressure gradient hypersonic laminar boundary layers for various gases with particular application to the flows produced in an expansion tube facility was conducted. A correlation based on results obtained from solutions to the governing equations for five gases was formulated. Particular attention was directed toward the laminar boundary layer shock tube splitter plates in carbon dioxide flows generated by high speed shock waves. Computer analysis of the splitter plate boundary layer flow provided information that is useful in interpreting experimental data obtained in shock tube gas radiation studies.

Cook, W. J.↗

Apparatus for production, measurement and reaction studies of dissociated gases at elevated temperatures

An apparatus is described which is used for the controlled production, characterization, and study of dissociated gases in a microwave discharge at elevated temperatures. A unique feature is the ability to produce and study a microwave discharge plasma in the heated zone. This allows elevated temperature reactions to be studied in high concentrations of dissociated gases. Further, the system permits weight change measurements of specimens in the plasma, thus facilitating reaction rate determinations. Included is a description of a cavity for use on a 50-mm diameter cylindrical reactor. The effects of flow rate, pressure, temperature, power, metal sample, and sampling position on dissociation percentage of oxygen in the apparatus are described as well as a technique for sample temperature measurements in the plasma which permits determination of high temperature recombination coefficients and reaction rates.

Christian, J. D.↗

A study of the toxicology of pyrolysis gases from synthetic polymers

An apparatus and procedure for evaluating the toxicity of pyrolysis gases from synthetic polymers are described. In each test, four Swiss albino mice are exposed in a 5-liter chamber to the gases from materials pyrolyzed at 700 C. The apparatus is simple in design, easy to clean, inexpensive and gives reproducible results. Data on several fluorine-containing and polyamide polymers are presented.

Young, W.↗