Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GOLD IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

TU-H-CAMPUS-TeP2-03: High Sensitivity and High Resolution Fiber Based Micro-Detector for Sub-Millimeter Preclinical Dosimetry

Purpose: Current precision of small animal and cell micro-irradiators has continuously increased during the past years. Currently, preclinical irradiators can deliver sub-millimeter fields with micrometric precision but there are no water equivalent dosimeters to determine small field profiles and dose in the orthovoltage range of energies with micrometric resolution and precision. We have developed a fiber based micro-dosimeter with the resolution and dosimetric accuracy required for radiobiological research. Methods: We constructed two prototypes of micro-dosimeters based on different compositions of fiber scintillators to study the spatial resolution and dosimetric precision of small animal and cell micro-irradiators. The first has green output and the second has blue output. The blue output dosimeter has the highest sensitivity because it matches the spectral sensitivity of silicon photomultipliers. A blue detector with 500um cross section was built and tested respect to a CC01 ion chamber, film, and the 1500um green output detector. Orthovoltage fields from 1×1mm2 to 5×5mm2 were used for detector characteristics comparison. Results: The blue fiber dosimeter shows great agreement with films and matches dose measurements with the gold-standard ion chamber for 5×5mm2 fields. The detector has the appropriate sensitivity to measure fields from 1×1mm2 to larger sizes with a 1% dosimetric accuracy. The spatial resolution is in the sub-millimeter range and the spectral matching with the photomultiplier allows reducing the sensor cross section even further than the presented prototype. These results suggest that scintillating fibers combined with silicon photomultipliers is the appropriate technology to pursue micro-dosimetry for small animals and disperse cell samples. Conclusion: The constructed detectors establish a new landmark for the resolution and sensitivity of fiber based microdetectors. The validation of the detector in our small animal and cell irradiator shows that they are appropriate for preclinical and micro single cell irradiation quality assurance and dosimetry.

60 APPLIED LIFE SCIENCES↗

SU-E-T-518: Investigation of Gold Nanoparticle Radiosensitization for Carbon Ion Therapy

Purpose The aim of this work is to investigate the radiosensitization effect of gold nanoparticles (GNP) in carbon ion irradiation. Nano-scale dosimetric characteristics of GNP interaction with carbon ions as well as the secondary particles generated as a carbon beam traverses the water phantom were studied. Methods Monte Carlo simulations were carried out using TOPAS (Tool for Particle Simulation). First, a water phantom was irradiated by the carbon ion beam and the particle shower spectrum at several depths was recorded in phase spaces. We analyzed the number and energy spectrum of each particle type. Then, the phase spaces obtained from Step 1 were modified to nanometer scale to irradiate a single 50 nm GNP. The secondary electrons that escaped from the GNPs following interactions with each particle type were recorded as phase spaces. The number and energy spectrum of the secondary electrons were studied. The same simulations were repeated replacing the GNPs with water nanoparticles (WNPs) with the same size. The energy absorbed in either GNP or WNP was scored. Results There is a large amount of secondary particles generated through carbon ion beam interaction with the water phantom. Analysis of the secondary electrons generated by the primary particles which escape from the nanoparticle revealed that majority (above 80%) of these electrons were generated by the GNP interaction with Carbon beam itself, making it the biggest contributor to the enhancement. The ratio of the energy absorbed by GNP and WNP is about 8–10 for charged particles and above 3000 for gammas. Conclusion We showed in the study the GNPs may potentially be used to enhance carbon ion therapy, and the main mechanism of enhancement is the interaction with Carbon ion particles itself.

60 APPLIED LIFE SCIENCES↗

Creating The Perfect Liquid In Heavy-Ion Collisions

In 2005 the four experimental groups at Brookhaven National Laboratory's Relativistic Heavy Ion Collider (RHIC) announced that collisions of gold nuclei at ultrarelativistic energies produced a 'perfect liquid' of quarks and gluons. That's something quite different from the gaseous quark-gluon state theorists and experimenters were expecting from quantum chromodynamics, the standard theory of the strong interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliable operation of the Brookhaven EBIS for highly charged ion production for RHIC and NSRL

An Electron Beam Ion Source for the Relativistic Heavy Ion Collider (RHIC EBIS) was commissioned at Brookhaven in September 2010 and since then it routinely supplies ions for RHIC and NASA Space Radiation Laboratory (NSRL) as the main source of highly charged ions from Helium to Uranium. Using three external primary ion sources for 1+ injection into the EBIS and an electrostatic injection beam line, ion species at the EBIS exit can be switched in 0.2 s. A total of 16 different ion species have been produced to date. The length and the capacity of the ion trap have been increased by 20% by extending the trap by two more drift tubes, compared with the original design. The fraction of Au{sup 32+} in the EBIS Au spectrum is approximately 12% for 70-80% electron beam neutralization and 8 pulses operation in a 5 Hertz train and 4-5 s super cycle. For single pulse per super cycle operation and 25% electron beam neutralization, the EBIS achieves the theoretical Au{sup 32+} fractional output of 18%. Long term stability has been very good with availability of the beam from RHIC EBIS during 2012 and 2014 RHIC runs approximately 99.8%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visualization of expanding warm dense gold and diamond heated rapidly by laser-generated ion beams

With the development of several novel heating sources, scientists can now heat a small sample isochorically above 10,000 K. Although matter at such an extreme state, known as warm dense matter, is commonly found in astrophysics (e.g., in planetary cores) as well as in high energy density physics experiments, its properties are not well understood and are difficult to predict theoretically. This is because the approximations made to describe condensed matter or high-temperature plasmas are invalid in this intermediate regime. A sufficiently large warm dense matter sample that is uniformly heated would be ideal for these studies, but has been unavailable to date. We have used a beam of quasi-monoenergetic aluminum ions to heat gold and diamond foils uniformly and isochorically. For the first time, we visualized directly the expanding warm dense gold and diamond with an optical streak camera. Furthermore, we present a new technique to determine the initial temperature of these heated samples from the measured expansion speeds of gold and diamond into vacuum. We anticipate the uniformly heated solid density target will allow for direct quantitative measurements of equation-of-state, conductivity, opacity, and stopping power of warm dense matter, benefiting plasma physics, astrophysics, and nuclear physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gold-implanted shallow conducting layers in polymethylmethacrylate

PMMA (polymethylmethacrylate) was ion implanted with gold at very low energy and over a range of different doses using a filtered cathodic arc metal plasma system. A nanometer scale conducting layer was formed, fully buried below the polymer surface at low implantation dose, and evolving to include a gold surface layer as the dose was increased. Depth profiles of the implanted material were calculated using the Dynamic TRIM computer simulation program. The electrical conductivity of the gold-implanted PMMA was measured in situ as a function of dose. Samples formed at a number of different doses were subsequently characterized by Rutherford backscattering spectrometry, and test patterns were formed on the polymer by electron beam lithography. Lithographic patterns were imaged by atomic force microscopy and demonstrated that the contrast properties of the lithography were well maintained in the surface-modified PMMA.

36 MATERIALS SCIENCE↗

Experimental study of single-electron detachment for Cu{sup −}, Ag{sup −}, Au{sup −}, Co{sup −}, and Ir{sup −} in collisions with Kr and Xe

The single electron detachment (SED) cross sections for Cu{sup −}, Ag{sup −}, Au{sup −}, Co{sup −}, and Ir{sup −} in collisions with Kr and Xe in the energy range of 10keV≤E≤30keV are measured by using the growth rate method in our experiments. The SED cross sections increase as the incident velocity increases. These data are compared with other available experimental data for the corresponding negative ions colliding with Ar. The affinities of the negative ions and the mass relation between the projectile and the target seem important in the electron detachment process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electronic stopping powers for heavy ions in SiC and SiO{sub 2}

Accurate information on electronic stopping power is fundamental for broad advances in materials science, electronic industry, space exploration, and sustainable energy technologies. In the case of slow heavy ions in light targets, current codes and models provide significantly inconsistent predictions, among which the Stopping and Range of Ions in Matter (SRIM) code is the most commonly used one. Experimental evidence, however, has demonstrated considerable errors in the predicted ion and damage profiles based on SRIM stopping powers. In this work, electronic stopping powers for Cl, Br, I, and Au ions are experimentally determined in two important functional materials, SiC and SiO{sub 2}, based on a single ion technique, and new electronic stopping power values are derived over the energy regime from 0 to 15 MeV, where large deviations from the SRIM predictions are observed. As an experimental validation, Rutherford backscattering spectrometry (RBS) and secondary ion mass spectrometry (SIMS) are utilized to measure the depth profiles of implanted Au ions in SiC for energies from 700 keV to 15 MeV. The measured ion distributions by both RBS and SIMS are considerably deeper than the SRIM predictions, but agree well with predictions based on our derived stopping powers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Energy loss of keV fluorine ions scattered off a missing-row reconstructed Au(110) surface under grazing incidence

A joint experimental and theoretical study of energy loss is presented for 1-to-4-keV fluorine negative ions in grazing scattering on a missing-row reconstructed Au(110) surface. Measurements of energy losses for various azimuthal orientations of the crystal have been performed by means of a time-of-flight method with a pulsed beam. The dependence of the fraction of surviving negative ions on azimuthal angles, was determined. Our energy-loss data are discussed in light of trajectory and stopping-power calculations, where the explicit inclusion of the nonuniform electron density at the surface provides good agreement with the experimental data. The simulation allows us to delineate various trajectory classes that correspond to different contributions in the energy-loss spectra for various azimuthal orientations of the surface.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ion irradiation induced phase transformation in gold nanocrystalline films

Gold is a noble metal typically stable as a solid in a face-centered cubic (FCC) structure under ambient conditions; however, under particular circumstances aberrant allotropes have been synthesized. In this work, we document the phase transformation of 25 nm thick nanocrystalline (NC) free-standing gold thin-film via in situ ion irradiation studied using atomic-resolution transmission electron microscopy (TEM). Utilizing precession electron diffraction (PED) techniques, crystallographic orientation and the radiation-induced relative strains were measured and furthermore used to determine that a combination of surface and radiation-induced strains lead to an FCC to hexagonal close packed (HCP) crystallographic phase transformation upon a 10 dpa radiation dose of Au 4+ ions. Contrary to previous studies, HCP phase in nanostructures of gold was stabilized and did not transform back to FCC due to a combination of size effects and defects imparted by damage cascades.

36 MATERIALS SCIENCE↗

Development of high current Bi and Au beams for the synchrotron operation at the GSI accelerator facility

In this work, the latest results of developing high current ion beams of Au and Bi at GSI facility are described. The difficulties in the production of required charge state in vacuum arc discharge ion sources using the pure materials in the cathodes are discussed. As a possible solution, admix of a small amount of more refractory metal to the cathode material is considered. As a significant result, a dramatic improvement in the production of high charge state Bi ions using the mixed Bi-Cu cathodes (with 8%-15% of Cu admixed) compared to pure Bi cathodes is presented. The preliminary results of investigation of the material structure of Bi-Cu cathodes are discussed. As a next step, it is planned to test the composition of Au with Pd, Zr, and Fe as cathode materials.

43 PARTICLE ACCELERATORS↗

Erosive versus shadowing instabilities in the self-organized ion patterning of polycrystalline metal films

We report on the self-organized patterning of polycrystalline metal films supported on dielectric substrates using defocused Ar{sup +} ion-beam sputtering at glancing incidence. The data demonstrate that a nonflat initial surface morphology does plays a critical role in triggering self-organization during the early stages, where the distribution of polycrystalline grains initially imposes a nonstochastic spatial modulation of the ion impact sites. A crossover to the conventional erosive regime observed for single crystals sets in at longer sputtering times. Surprisingly, the vertical and lateral modulation of the pristine surface profile of the nonflat films results in a substantial reduction in the ion dose required for the formation of the nanoscale patterns, in comparison to the case of an initially flat film.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Metallic glass as a temperature sensor during ion plating

The temperature of the interface and/or a superficial layer of a substrate during ion plating was investigated using a metallic glass of the composition Fe67Co18B14Si1 as the substrate and as the temperature sensor. Transmission electron microscopy and diffraction studies determined the microstructure of the ion-plated gold film and the substrate. Results indicate that crystallization occurs not only in the film, but also in the substrate. The grain size of crystals formed during ion plating was 6 to 60 nm in the gold film and 8 to 100 nm in the substrate at a depth of 10 to 15 micrometers from the ion-plated interface. The temperature rise of the substrate during ion plating was approximately 500 C. Discontinuous changes in metallurgical microstructure, and physical, chemical, and mechanical properties during the amorphous to crystalline transition in metallic glasses make metallic glasses extremely useful materials for temperature sensor applications in coating processes.

Miyoshi, K.↗

Metallic glass as a temperature sensor during ion plating

The temperature of the interface and/or a superficial layer of a substrate during ion plating was investigated using a metallic glass of the composition Fe67Co18B14Si1 as the substrate and as the temperature sensor. Transmission electron microscopy and diffraction studies determined the microstructure of the ion-plated gold film and the substrate. Results indicate that crystallization occurs not only in the film, but also in the substrate. The grain size of crystals formed during ion plating was 6 to 60 nm in the gold film and 8 to 100 nm in the substrate at a depth of 10 to 15 micrometers from the ion-plated interface. The temperature rise of the substrate during ion plating was approximately 500 C. Discontinuous changes in metallurgical microstructure, and physical, chemical, and mechanical properties during the amorphous to crystalline transition in metallic glasses make metallic glasses extremely useful materials for temperature sensor applications in coating processes.

Miyoshi, K.↗

Size-dependent effect of ion bombardment on Au nanoparticles on top of various substrates: Thermodynamically dominated capillary forces versus sputtering

Hexagonally ordered arrays of Au nanoparticles exhibiting narrow size distributions were prepared on top of Si wafers with either a thin native oxide or a thick thermally oxidized layer as well as on top of crystalline (0001)-oriented sapphire substrates. Subsequent irradiation of these nanoparticles by 200 keV Ar{sup +} and Xe{sup +}, respectively, in combination with transmission electron microscopy analysis (TEM) corroborated the previously reported phenomenon of bombardment-induced burrowing of metallic nanoparticles into SiO{sub x} while conserving their spherical shape [X. Hu et al., J. Appl. Phys. 92, 3995 (2002)]. Performing the ion irradiations on particle ensembles of different radii R{sub 0} (1.3 nm{<=}R{sub 0}{<=}5.3 nm) and determining the burrowing effect by atomic force microscopy combined with TEM provide sufficient statistics to allow a quantitative description of this effect. In addition to the thermodynamic driving forces necessary for the burrowing effect, sputtering of the nanoparticles due to the ion bombardment has to be included to arrive at an excellent theoretical description of the experimental data. The magnitude of sputtering can be quantified for the Au/sapphire system, where the burrowing effect is found to be completely suppressed. In that case, the theoretical description can even be improved by assuming a size-dependent sputtering coefficient for the Au nanoparticles. Combining this type of sputtering with the thermodynamically driven burrowing effect delivers a consistent model for all ion bombarded Au nanoparticles on top of SiO{sub x}. Specifically, the residual heights of the Ar{sup +}- or Xe{sup +}-induced burrowing of Au nanoparticles can be scaled on top of each other if plotted versus the average displacements per target atom rather than versus the applied ion fluences.

36 MATERIALS SCIENCE↗

Importance of ion bombardment during coverage of Au nanoparticles on their structural features and optical response

This work studies the changes in the optical response and morphological features of 6 ± 1 nm diameter Au nanoparticles (NPs) when covered by a layer of a-Al{sub 2}O{sub 3} by pulsed laser deposition (PLD). The laser fluence used for ablating the Al{sub 2}O{sub 3} target is varied in order to modify the kinetic energy (KE) of the species bombarding the NPs during their coverage. When the ion KE < 200 eV, the structural features and optical properties of the NPs are close to those of uncovered ones. Otherwise, a shift to the blue and a strong damping of the surface plasmon resonance is observed as fluence is increased. There are two processes responsible for these changes, both related to aluminum ions arriving to the substrate during the coverage process, i.e., sputtering of the metal and implantation of aluminum species in the metal. Both processes have been simulated using standard models for ion bombardment, the calculated effective implanted depths allow explaining the observed changes in the optical response, and the use of a size-dependent sputtering coefficient for the Au NPs predicts the experimental sputtering fractions. In spite of the work is based on PLD, the concepts investigated and conclusions can straightforwardly be extrapolated to other physical vapor deposition techniques or processes involving ion bombardment of metal NPs by ions having KE > 200 eV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗