Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GLOBAL WARMING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Benefits of Leapfrogging to Superefficiency and Low Global Warming Potential Refrigerants in Room Air Conditioning

Hydrofluorocarbons (HFCs) emitted from uses such as refrigerants and thermal insulating foam, are now the fastest growing greenhouse gases (GHGs), with global warming potentials (GWP) thousands of times higher than carbon dioxide (CO2). Because of the short lifetime of these molecules in the atmosphere, mitigating the amount of these short-lived climate pollutants (SLCPs) provides a faster path to climate change mitigation than control of CO2 alone. This has led to proposals from Africa, Europe, India, Island States, and North America to amend the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) to phase-down high-GWP HFCs. Simultaneously, energy efficiency market transformation programs such as standards, labeling and incentive programs are endeavoring to improve the energy efficiency for refrigeration and air conditioning equipment to provide life cycle cost, energy, GHG, and peak load savings. In this paper we provide an estimate of the magnitude of such GHG and peak electric load savings potential, for room air conditioning, if the refrigerant transition and energy efficiency improvement policies are implemented either separately or in parallel. We find that implementing HFC refrigerant transition and energy efficiency improvement policies in parallel for room air conditioning, roughly doubles the benefit of either policy implemented separately. We estimate that shifting the 2030 world stock of room air conditioners from the low efficiency technology using high-GWP refrigerants to higher efficiency technology and low-GWP refrigerants in parallel would save between 340-790 gigawatts (GW) of peak load globally, which is roughly equivalent to avoiding 680-1550 peak power plants of 500MW each. This would save 0.85 GT/year annually in China equivalent to over 8 Three Gorges dams and over 0.32 GT/year annually in India equivalent to roughly twice India’s 100GW solar mission target. While there is some uncertainty associated with emissions and growth projections, moving to efficient room air conditioning (~30% more efficient than current technology) in parallel with low-GWP refrigerants in room air conditioning could avoid up to ~25 billion tonnes of CO2 in 2030, ~33 billion in 2040, and ~40 billion in 2050, i.e. cumulative savings up to 98 billion tonnes of CO2 by 2050. Therefore, superefficient room ACs using low-GWP refrigerants merit serious consideration to maximize peak load reduction and GHG savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits of Leapfrogging to Superefficiency and Low Global Warming Potential Refrigerants in Room Air Conditioning

Hydrofluorocarbons (HFCs) emitted from uses such as refrigerants and thermal insulating foam, are now the fastest growing greenhouse gases (GHGs), with global warming potentials (GWP) thousands of times higher than carbon dioxide (CO2). Because of the short lifetime of these molecules in the atmosphere,1 mitigating the amount of these short-lived climate pollutants (SLCPs) provides a faster path to climate change mitigation than control of CO2 alone. This has led to proposals from Africa, Europe, India, Island States, and North America to amend the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) to phase-down high-GWP HFCs. Simultaneously, energy efficiency market transformation programs such as standards, labeling and incentive programs are endeavoring to improve the energy efficiency for refrigeration and air conditioning equipment to provide life cycle cost, energy, GHG, and peak load savings. In this paper we provide an estimate of the magnitude of such GHG and peak electric load savings potential, for room air conditioning, if the refrigerant transition and energy efficiency improvement policies are implemented either separately or in parallel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of 1.5 °C and 2.0 °C global warming above pre-industrial on potential winter wheat production of China

Keeping global temperatures below 2.0 °C above pre-industrial condition and pursuing efforts toward the more ambitious 1.5 °C goal in the late 21st century was the main target from the Paris Agreement in 2015. Here we assessed the likely challenges for the China’s winter wheat production under 1.5 °C and 2.0 °C increase of global temperature, with four wheat crop models (CERES-Wheat, Nwheat, WheatGrow, and APSIM-Wheat) and the latest climate projections from the Half a degree Additional warming, Prognosis and Projected Impacts project (HAPPI). Instead of using average “winter type” wheat cultivar, and same management and soil inputs for whole region, location-specific winter wheat cultivars with local agronomic information were calibrated for each of the representative wheat growing area of China, allowing a better spatial agronomic representation of the whole wheat planting area. The mean growing season temperature (GST) during the winter wheat vegetative stage was projected to increase by 0.6 to 1.4 °C for the 1.5 °C scenario, and 0.9 to 1.8 °C for the 2.0 °C scenario, while during the reproductive stage was decreased between 0 and 0.9 °C for the 1.5 °C scenario and -0.3 and 1.1 °C for the 2.0 °C scenario. Growing season duration (GSD) for the whole period was shortened by 6 to 15 days for the 1.5 °C scenario and 8 to 18 days for the 2.0 °C scenario, as a result of higher GST under global warming. Increase in GST and decrease in GSD was more obvious in the Southwest Subregion (SWS) than subregions in the north. The shortening GSD for the whole wheat growth period was mostly from the shortening vegetative period, as no appreciable difference in number of days from anthesis to maturity was found for the whole regions. Although there is variability among models, the indication is that wheat yields were projected to increase in the North Subregion (NS), the Huang-Huai Subregion (HHS), and the Middle-lower Researches of Yangzi River Subregion (MYS), but to decrease in the SWS under two warming scenarios. The effects of elevated CO2 concentration were mostly beneficial and tended to offset the negative impacts of increasing temperature at both global warming scenarios, with a rate of 7-14% yield increase per 100-ppm, except for locations with GST of baseline higher than 11 °C. Aggregating to regional wheat production, the total winter wheat production of China was projected to increase by 2.8% (1.6% to 3.0%, 25th percentile to 75th percentile) and 8.3% (7.0% to 9.6%, 25th percentile to 75th percentile) under 1.5 °C and 2.0 °C scenarios, and most of increase was observed in the north subregions due to the largest wheat planting area. Our results will lay the foundation for developing adaptation strategies to future climate change to ensure China and global wheat supply and food security.

Winter wheat↗

Options for low-global-warming-potential and natural refrigerants part I: Constrains of the shape of the P–T and T–S saturation phase boundaries

Current research focus is migrating toward low-global-warming-potential (GWP) and natural refrigerants to address the human impact on climate change. In this paper, we examine 13 refrigerants from the perspective of the characteristic shape of their respective temperature–entropy (T–S) and the logarithm of the pressure versus inverse absolute temperature (log P vs. T –1 ) saturated phase boundary. Such analyses explain why certain refrigerants possess a re-entrant characteristic while others do not. The re-entrant region is due to skewness of the saturation boundary. The cause of skewness is investigated for its importance in heat pump performance, design, and configuration. Re-entrant behavior contributes to premature mechanical wear of compressor components. Knowledge of the properties of the phase boundary on either side of the critical point, is useful for a better perspective on discriminating refrigerants, as hydrochlorofluorocarbons are phased out and replacement refrigerants must be found. Here, we conclude by identifying a candidate low-GWP refrigerant for heat pumps. In Part II, we evaluate all 13 refrigerants in thermodynamic cycles based on exergy analysis to identify sources of irreversibility, the root cause of systemic inefficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits of Energy Efficient and Low-Global Warming Potential Refrigerant Cooling Equipment

Hydrofluorocarbons (HFCs) are the fastest growing type of greenhouse gases (GHG) emissions, increasing at an annual rate of 10-15% [1]. HFCs are primarily used as refrigerants in air conditioning and refrigeration equipment and have a global warming potential (GWP) many thousands of times greater than CO 2 . Their rapid growth has led to a global agreement to aggressively phase down their production by amending the Montreal Protocol on Substances that Deplete the Ozone Layer [2]. We quantify the GHG benefits implementing aggressive but economic energy efficiency measures (about 30% more efficient than current technology) in air-conditioning (AC) and large commercial refrigeration equipment (CRE) together with low-GWP refrigerants. Shifting the 2030 world stock of room ACs and CRE from current levels of energy-efficiency and high-GWP refrigerants to “economic” energy efficiency levels and low-GWP refrigerants by 2050 would avoid up to 240.1 GT CO 2e and shifting to “best-available technology” energy efficiency levels and low GWP refrigerants by 2050 would avoid up to 373 GT CO 2e with existing electricity grid emission factors. About two-thirds of this cumulative savings are from reduced electricity sector emissions from improved energy efficiency. Thus, it is highly beneficial to pursue high energy efficiency in concert with the transition to lower GWP refrigerants to achieve maximal GHG reductions with the least amount of equipment re-design and replacement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Assessment of High-Efficiency Refrigerated Display Cases With Low Global Warming Potential Refrigerants

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison, was to assess the energy performance of two high-efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290, GWP = 3), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513A (GWP = 573). Performance of these display cases was compared to a baseline fixture using HFC (R-134A, GWP = 1301) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores and small supermarkets. The high-efficiency cases were equipped with energy-efficient lighting, improved panel insulation, high-efficiency evaporator and condenser fan motors, and high-effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions (ASHRAE 2018). However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining equivalent target product temperature, the energy-efficient fixtures A (containing R-290, improved insulation, heat exchangers with a higher overall heat transfer coefficient (higher UA), and more efficient lighting and fan motors) and B (containing R-513A, improved fans, and higher UA-heat exchangers, and more efficient lighting and fan motors) consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134A refrigerant. The daily energy consumption of the R-290, R-513A, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

Contrasting phase changes of precipitation annual cycle between land and ocean under global warming

The annual cycle of precipitation is a fundamental aspect of the water cycle with global ramification. Climate warming induces a robust phase delay1-5 in zonal mean tropical precipitation concomitant with an amplitude enhancement6-8. Here, we find a large land ocean contrast in the phase response of precipitation annual cycle, with a phase delay over land and a phase advance over ocean as climate warms. The phase delay over land is mainly attributed to the increase in the effective heat capacity of the atmosphere, while the phase advance over ocean is associated with a precipitation shift from land to ocean during the peak rainy season. Through the energetic constraint, this precipitation shift is closely related to the opposite changes in the amplitude of surface temperature annual cycle between land and ocean, both as consequences of basic climate feedback processes under global warming: weakening of the summer trade wind over the tropical ocean increases the surface temperature seasonal amplitude through evaporation, while an increase of the atmospheric effective heat capacity and surface cooling feedback induces opposite temperature amplitude changes over the tropical land. The opposite precipitation phase changes between land and ocean will have myriad implications for terrestrial/marine ecosystems and human activities.

Song, Fengfei↗

Condensation heat transfer and pressure drop of low-global warming potential refrigerants in smooth aluminum tubes

In this work we report condensation heat transfer coefficient and pressure drop data for R-454B, R-32, and R-454C. These refrigerants are low Global Warming Potential (GWP) replacements for R-410A. We obtained these data in a smooth 7.2 mm outer diameter (5.94 mm inner diameter) aluminum tube. In these experiments, the key variables were condensation temperature (35 °C ≤ T cond ≤ 50 °C) and refrigerant mass flux (151.1 ≤ G ≤ 347.3 kg m –2 s –1 ). In general, for similar nominal operating conditions, we measured the highest heat transfer coefficients for R-32 and the lowest for R-454C. Among the correlations we used to predict the heat transfer data for all three refrigerants, the one developed by Thome et al. (2003) predicted the data with the greatest accuracy. Deviations between experimental data and predictions of this correlation were 21.7% for R-454B (with SBG correction), 22.0% for R-32, and 18.8% for R-454C (with SBG correction). Experimental pressure gradient data were predicted by the Friedel correlation Friedel (1979) with deviations of 13.8% for R-454B, 9.8% for R-32, and 10.2% for R-454C. In this work, we also compare the predictions of the Cavallini et al. correlation Cavallini et al. (2006) for R-454B and R-32 in smooth copper versus smooth aluminum tubes. To improve this correlation’s predictive capability for aluminum tubes, we have proposed some modifications. After incorporating these modifications, the deviations between the correlation’s predictions and our data were 10% for R-454B (with SBG correction), 8.1% for R-32, and 5.2% for R-454C (with SBG correction). Furthermore, these data and findings will assist the HVAC and refrigeration industry to implement low-GWP refrigerants in condensers using smooth aluminum tubes.

Aluminum tube↗

Amplified Mesoscale and Submesoscale Variability and Increased Concentration of Precipitation under Global Warming over Western North America

Abstract Cold-season precipitation statistics in simulations from the storm-resolving WRF Model at 6-km and 1-h resolution over western North America are analyzed. Pseudo–global warming future simulations for the 2041–80 period, constrained by GCMs under the RCP8.5 scenario, are compared to the 1981–2020 historical simulation. The analysis focuses on the dynamical properties of precipitation time series at subdaily scales and on the morphology of storms. The statistical distribution of precipitation intensities in each pixel of the simulation domain is characterized through nonparametric statistical indicators: frequency of wet hours, mean wet-hour precipitation intensity, and Gini coefficient as a measure of the temporal concentration of the precipitation volume. Additionally, the temporal and spatial Fourier power spectra of precipitation time series and precipitation fields are analyzed. The half-power period (HPP) and half-power wavelength (HPW) are defined as spectral measures of the characteristic scales of precipitation’s temporal and spatial patterns. The results show statistically significant increases in the mean wet-hour precipitation intensity and in the Gini coefficient in 99% of the pixels, indicating that the seasonal precipitation volume becomes more concentrated within a smaller number of hours with higher precipitation intensity. The statistics of change in the frequency of wet hours are more contrasted across the simulation domain. The changes are also reflected in the power spectra, which show the spatial and temporal variability increasing proportionally more with finer spatial and temporal scales and the HPW and HPP decreasing. These projected changes are expected to have consequences, not only in terms of hydrologic impacts but also in terms of the predictability of precipitation patterns. Significance Statement The precipitation characteristics of winter storms over the western United States and southwestern Canada are analyzed in future climate simulations for the 2041–80 period. As compared to present-day climate, the most intense parts of the storms are projected to produce a higher rainfall volume, with increased concentration over smaller areas and shorter time intervals. The propensity of rainfall intensity to vary rapidly over time will be enhanced in the future according to the simulations. These model predictions imply an increased risk of rapid flooding in small basins. They also suggest that predicting several hours ahead the time and location at which a storm will produce maximum rainfall may become more challenging in the future.

Climate change↗

1,2-Dichlorohexafluoro-Cyclobutane (1,2-c-C4F6Cl2, R-316c) a Potent Ozone Depleting Substance and Greenhouse Gas: Atmospheric Loss Processes, Lifetimes, and Ozone Depletion and Global Warming Potentials for the (E) and (Z) stereoisomers

The atmospheric processing of (E)- and (Z)-1,2-dichlorohexafluorocyclobutane (1,2-c-C4F6Cl2, R-316c) was examined in this work as the ozone depleting (ODP) and global warming (GWP) potentials of this proposed replacement compound are presently unknown. The predominant atmospheric loss processes and infrared absorption spectra of the R-316c isomers were measured to provide a basis to evaluate their atmospheric lifetimes and, thus, ODPs and GWPs. UV absorption spectra were measured between 184.95 to 230 nm at temperatures between 214 and 296 K and a parametrization for use in atmospheric modeling is presented. The Cl atom quantum yield in the 193 nm photolysis of R- 316c was measured to be 1.90 +/- 0.27. Hexafluorocyclobutene (c-C4F6) was determined to be a photolysis co-product with molar yields of 0.7 and 1.0 (+/-10%) for (E)- and (Z)-R-316c, respectively. The 296 K total rate coefficient for the O(1D) + R-316c reaction, i.e., O(1D) loss, was measured to be (1.56 +/- 0.11) × 10(exp −10)cu cm/ molecule/s and the reactive rate coefficient, i.e., R-316c loss, was measured to be (1.36 +/- 0.20) × 10(exp −10)cu cm/molecule/s corresponding to a approx. 88% reactive yield. Rate coefficient upper-limits for the OH and O3 reaction with R-316c were determined to be <2.3 × 10(exp −17) and <2.0 × 10(exp −22)cu cm/molecule/s, respectively, at 296 K. The quoted uncertainty limits are 2(sigma) and include estimated systematic errors. Local and global annually averaged lifetimes for the (E)- and (Z)-R-316c isomers were calculated using a 2-D atmospheric model to be 74.6 +/- 3 and 114.1 +/-10 years, respectively, where the estimated uncertainties are due solely to the uncertainty in the UV absorption spectra. Stratospheric photolysis is the predominant atmospheric loss process for both isomers with the O(1D) reaction making a minor, approx. 2% for the (E) isomer and 7% for the (Z) isomer, contribution to the total atmospheric loss. Ozone depletion potentials for (E)- and (Z)-R-316c were calculated using the 2-D model to be 0.46 and 0.54, respectively. Infrared absorption spectra for (E)- and (Z)-R-316c were measured at 296 K and used to estimate their radiative efficiencies (REs) and GWPs; 100-year time-horizon GWPs of 4160 and 5400 were obtained for (E)- and (Z)-R-316c, respectively. Both isomers of R-316c are shown in this work to be long-lived ozone depleting substances and potent greenhouse gases.

UV cross section↗

Cosmic Rays and Global Warming

Some workers have claimed that the observed temporal correlations of (low level) terrestrial cloud cover with the cosmic ray intensity changes, due to solar modulation, are causal. The possibility arises, therefore, of a connection between cosmic rays and Global Warming. If true, the implications would be very great. We have examined this claim in some detail. So far, we have not found any evidence in support and so our conclusions are to doubt it. From the absence of corroborative evidence we estimate that less than 15% at the 95% confidence level, of the 11-year cycle warming variations are due to cosmic rays and less than 2% of the warming over the last 43 years is due to this cause. The origin of the correlation itself is probably the cycle of solar irradiance although there is, as yet, no certainty.

54 ENVIRONMENTAL SCIENCES↗

Regime shifts of the wet and dry seasons in the tropics under global warming

The main seasonal characteristics in the tropics include both spatial patterns and temporal parameters of onset, cessation, duration, and the number of wet and dry seasons. Previous studies showed that wet seasons shortened and dry seasons extended with global warming, but the changes in spatial distribution and the number of wet and dry seasons are still unclear. Here, we analyze the climatic characteristics of once wet and dry season a year (annual regime) and twice wet and dry seasons a year (biannual regime), and find that regimes of wet and dry seasons have changed from 1935 to 2014. Across the equator and the Tropic of Cancer and Capricorn, some regions where there used to be an annual regime have become a biannual regime; instead, other regions have shifted from a biannual regime into an annual regime. With seasonal regimes shifting, areas of the biannual regime have expanded at a rate of 31 000 km 2 /decade. Meanwhile, in annual regime regions, wet seasons have been shortened in 60.3% of regions, with an average of 7 d; the onset dates of wet seasons have been delayed in 64.8%, with an average of 6 d. Besides, wet seasons have become wetter in 51.1% of regions, and dry seasons have become drier in 59.9%. In biannual regime regions, the shortened wet seasons have occurred in 83.7% of regions, with an average shortening of 8 d, and precipitation has decreased in both wet and dry seasons. Moreover, the shorter wet seasons will amplify further by the end of the 21st century. The continuous seasonal changes will threaten agricultural, ecological security, and even human well-being.

54 ENVIRONMENTAL SCIENCES↗

Increasing water cycle extremes in California and relation to ENSO cycle under global warming

California has experienced its most severe drought in recorded history since the winter of 2013-2014. The long duration of drought has stressed statewide water resources and the economy, while fueling an extraordinary increase in wildfires. The effects of global warming on the regional climate include a hotter and drier climate, as well as earlier snowmelt, both of which exacerbate drought conditions. However, connections between a changing climate and how climate oscillations modulate regional water cycle extremes are not well understood. Here we analyze large-ensemble simulations of future climate change in California using the Community Earth System Model version 1 (CESM1) and multiple climate models participating in the Coupled Model Intercomparison Project Phase 5 (CMIP5). Both intense drought and excessive flooding are projected to increase by at least 50% toward the end of the 21st century. Furthermore, the projected increase in water cycle extremes is associated with tighter relation to El Niño and Southern Oscillation (ENSO), particularly extreme El Niño and La Niña events, which modulates California’s climate not only through its warm and cold phases, but also ENSO’s precursor patterns.

54 ENVIRONMENTAL SCIENCES↗

The impact of global warming on river runoff

A global atmospheric model is used to calculate the annual river runoff for 33 of the world's major rivers for the present climate and for a doubled CO2 climate. The model has a horizontal resolution of 4 x 5 deg, but the runoff from each model grid box is quartered and added to the appropriate river drainage basin on a 2 x 2.5 deg resolution. The computed runoff depends on the model's precipitation, evapotranspiration, and soil moisture storage. For the doubled CO2 climate, the runoff increased for 25 of the 33 rivers, and in most cases the increases coincide with increased rainfall within the drainage basins. There were runoff increases in all rivers in high northern latitudes, with a maximum increase of 47 percent. At low latitudes there were both increases and decreases ranging from a 96 increase to a 43 percent decrease. The effect of the simplified model assumptions of land-atmosphere interactions on the results is discussed.

Miller, James R.↗

Energy and Exergy Analysis of Low-Global Warming Potential Refrigerants as Replacement for R410A in Two-Speed Heat Pumps for Cold Climates

Heat pumps (HPs) are being developed with a new emphasis on cold climates. To lower the environmental impact of greenhouse gas (GHG) emissions, alternate low global warming potential (GWP) refrigerants must also replace the exclusive use of the refrigerant R410A, preferably without re-engineering the mechanical hardware. In this paper, we analyze the performance of four low-GWP alternative refrigerants (R32, R452B, R454B, and R466A) relative to the conventional R410A and draw conclusions on the relative performances for providing heating in cold climates based on the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) 210/240 standard for two-speed heat pumps. The simulations are carried using the Department of Energy, Oak Ridge National Laboratory (DOE/ORNL) Heat Pump Design Model (HPDM), a well-known heating, ventilation, and air conditioning (HVAC) modeling and design tool in the public domain and the HVAC research and development community. The results of the simulation are further scrutinized using exergy analysis to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate low-GWP refrigerants to replace R410A using available compressors and system components, without compromising performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Global Warming Estimation From Microwave Sounding Unit

Microwave Sounding Unit (MSU) Ch 2 data sets, collected from sequential, polar-orbiting, Sun-synchronous National Oceanic and Atmospheric Administration operational satellites, contain systematic calibration errors that are coupled to the diurnal temperature cycle over the globe. Since these coupled errors in MSU data differ between successive satellites, it is necessary to make compensatory adjustments to these multisatellite data sets in order to determine long-term global temperature change. With the aid of the observations during overlapping periods of successive satellites, we can determine such adjustments and use them to account for the coupled errors in the long-term time series of MSU Ch 2 global temperature. In turn, these adjusted MSU Ch 2 data sets can be used to yield global temperature trend. In a pioneering study, Spencer and Christy (SC) (1990) developed a procedure to derive the global temperature trend from MSU Ch 2 data. Such a procedure can leave unaccounted residual errors in the time series of the temperature anomalies deduced by SC, which could lead to a spurious long-term temperature trend derived from their analysis. In the present study, we have developed a method that avoids the shortcomings of the SC procedure, the magnitude of the coupled errors is not determined explicitly. Furthermore, based on some assumptions, these coupled errors are eliminated in three separate steps. Such a procedure can leave unaccounted residual errors in the time series of the temperature anomalies deduced by SC, which could lead to a spurious long-term temperature trend derived from their analysis. In the present study, we have developed a method that avoids the shortcomings of the SC procedures. Based on our analysis, we find there is a global warming of 0.23+/-0.12 K between 1980 and 1991. Also, in this study, the time series of global temperature anomalies constructed by removing the global mean annual temperature cycle compares favorably with a similar time series obtained from conventional observations of temperature.

Prabhakara, C.↗

Cryoinsulation Material Development to Mitigate Obsolescence Risk for Global Warming Potential Foams

Cryoinsulation foams currently being qualified for the Space Launch System (SLS) core stage are nonozone- depleting substances (ODP) and are compliant with current environmental regulations. However, these materials contain the blowing agent HFC-245fa, a hydrofluorocarbon (HFC), which is a Global Warming Potential (GWP) substance. In August 2014, the Environmental Protection Agency (EPA) proposed a policy change to reduce or eliminate certain HFCs, including HFC-245fa, in end-use categories including foam blowing agents beginning in 2017. The policy proposes a limited exception to allow continued use of HFC and HFC-blend foam blowing agents for military or space- and aeronautics-related applications, including rigid polyurethane spray foams, but only until 2022.

Protz, Alison↗