Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Functionally Graded”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Reconfigurable fuzzy cell

This invention relates to a reconfigurable fuzzy cell comprising a digital control programmable gain operation amplifier, an analog-to-digital converter, an electrically erasable PROM, and 8-bit counter and comparator, and supporting logic configured to achieve in real-time fuzzy systems high throughput, grade-of-membership or membership-value conversion of multi-input sensor data. The invention provides a flexible multiplexing-capable configuration, implemented entirely in hardware, for effectuating S-, Z-, and PI-membership functions or combinations thereof, based upon fuzzy logic level-set theory. A membership value table storing 'knowledge data' for each of S-, Z-, and PI-functions is contained within a nonvolatile memory for storing bits of membership and parametric information in a plurality of address spaces. Based upon parametric and control signals, analog sensor data is digitized and converted into grade-of-membership data. In situ learn and recognition modes of operation are also provided.

Salazar, George A.↗

Aviation turbine fuels: An assessment of alternatives

The general outlook for aviation turbine fuels, the effect that broadening permissible aviation turbine fuel properties could have on the overall availability of such fuels, the fuel properties most likely to be affected by use of lower grade petroleum crudes, and the research and technology required to ensure that aviation turbine fuels and engines can function satisfactorily with fuels having a range of fuel properties differing from those of current specification fuel are assessed. Views of industry representatives on alternative aviation turbine fuels are presented.

Source record↗

Testing of the ISS’s Charcoal HEPA Integrated Particle Scrubber (CHIPS) Filters to Ascertain an Efficiency Curve and Most Penetrating Particle Size

High air quality is a top priority in hermetically sealed environments, such as the International Space Station (ISS). Aerosol particulate filtration on the ISS is achieved via 21 HEPA filters. Traditional HEPA filters have an efficiency of 99.97%, but HEPA filters aboard the ISS have been found to achieve 99.99% efficiency. This may be due to the flight-grade HEPA filters chosen or, less likely, that they are combined with activated charcoal filters for siloxane removal in a combination referred to as Charcoal HEPA Integrated Particle Scrubbers (CHIPS) filters. All filters have a Most Penetrating Particle Size (MPPS), but, until now, the MPPS and efficiency curve of the CHIPS filters was not known. The efficiency curve of the CHIPS filters was ascertained at NASA Glenn Research Center through standard salt crystal aerosolization. This method was selected over aerosolized oil droplets due to a desire to preserve the filter’s function for further testing. The CHIPS filters were tested as they are oriented on the ISS (activated charcoal filter followed by a flight-grade HEPA filter), with the HEPA portion alone, and with the activated charcoal portion alone. The results of this experiment are generally useful but can be especially useful for the microbiology and Environmental Control and Life Support Systems (ECLSS). This is due to microbial contamination being a potential concern in the air revitalization systems on the ISS. Knowing the MMPS of the CHIPS filters, in conjunction with levels of airborne microbes, is useful for predicting which and how many microbes are likely to get through the HEPA filters that sit in the beginning of the ISS airstream. It may also be useful to other groups at NASA to know how many particulates are able to pass through high-efficiency filtration, and even for healthcare cleanrooms and other air purification pursuits.

A Nicolas Whitlock↗

Investigations of the mechanisms by which lower body negative pressure (LBNP) improves orthostatic responses

Saline ingestion during LBNP is a counter measure proposed to improve orthostatic function during space flight. To understand the mechanism(s) responsible for this effect, body fluid, endocrine, and orthostatic responses (graded LBNP tests) were measured during bed rest (BR) and after 2 hr and 4 hr LBNP/saline treatments (-30 mm Hg and 1 liter of isotonic saline). PV (from I-125 and hematocrit measurements) decreased during BR but was restored to the pre-bed rest level (3157 +/- 161 ml) 20 hrs after both 2 hr (3109 +/- 146 ml) and 4 hr (3144 +/- 173 ml) LBNP. The heart rate response to graded LBNP tests was significantly improved after the 4 hr, but not after the 2 hr treatment. These results suggest PV expansion may be responsible for some improvement in orthostatic responses, but other mechanisms also must contribute.

Fortney, S. M.↗

Meeting Radiation Protection Requirements and Reducing Spacecraft Mass - A Multifunctional Materials Approach

Both crew and radio-sensitive systems, especially electronics must be protected from the effects of the space radiation environment. One method of mitigating this radiation exposure is to use passive-shielding materials. In previous vehicle designs such as the International Space Station (ISS), materials such as aluminum and polyethylene have been used as parasitic shielding to protect crew and electronics from exposure, but these designs add mass and decrease the amount of usable volume inside the vehicle. Thus, it is of interest to understand whether structural materials can also be designed to provide the radiation shielding capability needed for crew and electronics, while still providing weight savings and increased useable volume when compared against previous vehicle shielding designs. In this paper, we present calculations and analysis using the HZETRN (deterministic) and FLUKA (Monte Carlo) codes to investigate the radiation mitigation properties of these structural shielding materials, which includes graded-Z and composite materials. This work is also a follow-on to an earlier paper, that compared computational results for three radiation transport codes, HZETRN, HETC, and FLUKA, using the Feb. 1956 solar particle event (SPE) spectrum. In the following analysis, we consider the October 1989 Ground Level Enhanced (GLE) SPE as the input source term based on the Band function fitting method. Using HZETRN and FLUKA, parametric absorbed doses at the center of a hemispherical structure on the lunar surface are calculated for various thicknesses of graded-Z layups and an all-aluminum structure. HZETRN and FLUKA calculations are compared and are in reasonable (18% to 27%) agreement. Both codes are in agreement with respect to the predicted shielding material performance trends. The results from both HZETRN and FLUKA are analyzed and the radiation protection properties and potential weight savings of various materials and materials lay-ups are compared.

Atwell, William↗

SPACEFLIGHT ASSOCIATED NEURO-OCULAR SYNDROME (SANS): 2023 CLINICAL UPDATE

INTRODUCTION Spaceflight Associated Neuro-ocular Syndrome (SANS) is a condition unique to long-duration spaceflight, with an unclear pathogenesis and pathophysiology, and no perfect terrestrial analog. Approximately 66% of long duration spaceflight (LDSF) astronauts present with the earliest indication of SANS, which is defined as development of any of the following signs in at least one eye during or immediately following spaceflight: 1) optic disc edema (ODE; represented by an increase of ≥ 20 microns in peripapillary total retinal thickness [ΔTRT]); 2) chorioretinal folds; 3) globe flattening; and 4) excessive shift in refractive error (≥ +0.75D). Each of these signs presents potential risk to a crewmember’s vision and mission effectiveness, with ODE posing the highest risk overall. It is not yet known what severity and/or duration of these signs might lead to acute or permanent impacts to ocular anatomy or visual performance. Brain anatomical changes also occur during long-duration spaceflight and are being monitored in the astronaut population; however, these changes have not yet been associated with functional decrements or with SANS. An update will be provided on the latest SANS clinical analyses, diagnostics, and program initiatives. METHODS Data were obtained from clinical records and SANS subject matter experts (SMEs) to compile a SANS clinical update. Areas of interest include: 1) prevalence of SANS signs, 2) defining clinical thresholds for SANS, and 3) an overview of current and planned SANS clinical efforts. DISCUSSION SANS Sign Prevalence: Analysis at the time of this abstract submission indicates that the approximate prevalence of primary SANS findings in USOS LDSF crewmembers is: 64% for ODE (≥ 20-micron ΔTRT), 15% for chorioretinal folds, 26% for globe flattening, and 14% for hyperopic shifts in refractive error (≥ +0.75D). Clinical Thresholds:  The Earliest Indication of SANS was presented publicly for the first time at the 2020 NASA Human Research Program Investigators’ Workshop. See definition in Introduction section (above).  Clinically Concerning SANS – Development of any of the following signs during or immediately following spaceflight: 1) ODE (≥ 55-micron ΔTRT* and/or Frisèn grade ≥1*), 2) sharp chorioretinal folds in the vicinity of the macula, or 3) moderate globe flattening.  Pathological SANS with an Acute Functional Impact – Development of any of the following signs/symptoms during or immediately following spaceflight: 1) visual field loss (e.g., enlarged blindspot), 2) distorted centralvision, or 3) shift in refractive error beyond power of available correction (e.g., “space anticipation glasses”).  Pathological SANS affecting Long-Term Health – Development of any of the following signs/symptoms during or following spaceflight: 1) permanent visual field loss, 2) reduced retinal nerve fiber layer (RNFL) thickness, 3) permanently distorted central vision, 4) atrophy of retinal pigment epithelium (RPE) or photoreceptors, or 5) choroidal neovascularization. Current & Planned Clinical Efforts (accurate at time of abstract submission): All SANS diagnostic hardware are performing nominally onboard the International Space Station: vision screening, fundoscope, optical coherence tomography (OCT) device, ultrasound, and tonometer. The Goggle-Based Visual Field (GBVF) device is nearing completion of its clinical validation study at Ohio State University and is planned for parabolic flight testing in fiscal year 2023 (FY23); pending positive results, this sequence may pave the way towards an ISS technology demonstration in FY24.

T J Brunstetter↗

Microwave Sterilization and Depyrogenation System

A fully functional, microgravity-compatible microwave sterilization and depyrogenation system (MSDS) prototype was developed that is capable of producing medical-grade water (MGW) without expendable supplies, using NASA potable water that currently is available aboard the International Space Station (ISS) and will be available for Lunar and planetary missions in the future. The microwave- based, continuous MSDS efficiently couples microwaves to a single-phase, pressurized, flowing water stream that is rapidly heated above 150 C. Under these conditions, water is rapidly sterilized. Endotoxins, significant biological toxins that originate from the cell walls of gram-negative bacteria and which represent another defining MGW requirement, are also deactivated (i.e., depyrogenated) albeit more slowly, with such deactivation representing a more difficult challenge than sterilization. Several innovations culminated in the successful MSDS prototype design. The most significant is the antenna-directed microwave heating of a water stream flowing through a microwave sterilization chamber (MSC). Novel antenna designs were developed to increase microwave transmission efficiency. These improvements resulted in greater than 95-percent absorption of incident microwaves. In addition, incorporation of recuperative heat exchangers (RHxs) in the design reduced the microwave power required to heat a water stream flowing at 15 mL/min to 170 C to only 50 W. Further improvements in energy efficiency involved the employment of a second antenna to redirect reflected microwaves back into the MSC, eliminating the need for a water load and simplifying MSDS design. A quick connect (QC) is another innovation that can be sterilized and depyrogenated at temperature, and then cooled using a unique flow design, allowing collection of MGW at atmospheric pressure and 80 C. The final innovation was the use of in-line mixers incorporated in the flow path to disrupt laminar flow and increase contact time at a given flow rate. These technologies can be employed in small-scale systems for efficient production of MGW in the laboratory or in a range of larger systems that meet various industrial requirements. The microwave antennas can also be adapted to selectively sterilize vulnerable connections to ultra-pure water production facilities or biologically vulnerable systems where microorganisms may intrude.

Akse, James R.↗

Hydrogen enhanced crack growth in 18 Ni maraging steels

The kinetics of sustained-load subcritical crack growth for 18 Ni maraging steels in high-purity hydrogen are examined using the crack-tip stress intensity factor K as a measure of crack driving force. Crack growth rate as a function of stress intensity exhibited a clearly defined K-independent stage (Stage II). Crack growth rates in an 18 Ni (grade 250) maraging steel are examined for temperatures from -6 to +100 C. A critical temperature was observed above which crack growth rates became diminishingly small. At lower temperatures the activation energy for Stage II crack growth was found to be 16.7 plus or minus 3.3 kJ/mole. Temperature and hydrogen partial pressure are shown to interact in a complex manner to determine the apparent Kth (stress intensity level below which no observable crack growth occurs) and the crack growth behavior. Comparison of results on '250' and '300' grades of 18 Ni maraging steel indicate a significant influence of alloy composition and/or strength level on the crack growth behavior.

Hudak, S. J., Jr.↗

High velocity continuous-flow reactor for the production of solar grade silicon

The feasibility of a high volume, high velocity continuous reduction reactor as an economical means of producing solar grade silicon was tested. Bromosilanes and hydrogen were used as the feedstocks for the reactor along with preheated silicon particles which function both as nucleation and deposition sites. A complete reactor system was designed and fabricated. Initial preheating studies have shown the stability of tetrabromosilane to being heated as well as the ability to preheat hydrogen to the desired temperature range. Several test runs were made and some silicon was obtained from runs carried out at temperatures in excess of 1180 K.

Woerner, L.↗

The 2001 Mars In-Situ-Propellant-Production Precursor (MIP) Flight Demonstration

The successful performance of the five individual demonstrations of MARS IN-SITU-PROPELLANT-PRODUCTION PRECURSOR (MIP) will provide both knowledge of and confidence in the reliability of this technology. At the completion of this flight demonstration, the MIP Team will be able to: a) recommend preferred hardware configurations for the intake and adsorption of carbon dioxide from the Martian atmosphere; b) understand the performance characteristics of zirconia cells to generate propellant-grade oxygen; c) understand long-term performance characteristics of advanced solar cells/arrays operated in the actual Mars environment; d) evaluate the functionality of methods to mitigate the deposition of airborne dust onto solar arrays; and e) recommend preferred hardware designs for innovative thermal management including the radiation of heat to the outside environment.

Kaplan, David I.↗

Left ventricular, systemic arterial, and baroreflex responses to ketamine and TEE in chronically instrumented monkeys

Effects of prescribed doses of ketamine five minutes after application and influences of transesophageal echocardiography (TEE) on left ventricular, systemic arterial, and baroreflex responses were investigated to test the hypothesis that ketamine and/or TEE probe insertion alter cardiovascular function. Seven rhesus monkeys were tested under each of four randomly selected experimental conditions: (1) intravenous bolus dose of ketamine (0.5 ml), (2) continuous infusion of ketamine (500 mg/kg/min), (3) continuous infusion of ketamine (500 mg/kg/min) with TEE, and (4) control (no ketamine or TEE). Monkeys were chronically instrumented with a high fidelity, dual-sensor micromanometer to measure left ventricular and aortic pressure and a transit-time ultrasound probe to measure aortic flow. These measures were used to calculate left ventricular function. A 4-element Windkessel lumped-parameter model was used to estimate total peripheral resistance and systemic arterial compliance. Baroreflex response was calculated as the change in R-R interval divided by the change in mean aortic pressure measured during administration of graded concentrations of nitroprusside. The results indicated that five minutes after ketamine application heart rate and left ventricular diastolic compliance decreased while TEE increased aortic systolic and diastolic pressure. We conclude that ketamine may be administered as either a bolus or continuous infusion without affecting cardiovascular function 5 minutes after application while the insertion of a TEE probe will increase aortic pressure. The results for both ketamine and TEE illustrate the classic "Hawthorne Effect," where the observed values are partly a function of the measurement process. Measures of aortic pressure, heart rate, and left ventricular diastolic pressure should be viewed as relative, as opposed to absolute, when organisms are sedated with ketamine or instrumented with a TEE probe.

Non-NASA Center↗

Advances in Detector-Integrated Filter Coatings for the Far Ultraviolet

We report on the continued development of multilayer optical coatings on back-illuminated silicon imaging sensors in order to enhance the functionality of such systems at ultraviolet wavelengths. This includes the development metal-dielectric filter structures to enable solar-blind operation, and graded thickness coatings to tune the spatial response of a detector system to the dispersion of a spectrometer. Such systems can maintain the high internal quantum efficiency afforded by the delta-doping process utilized at NASA JPL, while also providing long-wavelength rejection or a spatially optimized efficiency (or both). We present the characterization of CCD and CMOS image sensors incorporating these processes, and describe the atomic layer deposition coating processes. Such detectors are currently being developed for ground-based high energy physics applications as well as NASA orbital astrophysics instruments operating at wavelengths shorter than 200 nm.

Nikzad, Shouleh↗

Technology Directions for the 21st Century

New technologies will unleash the huge capacity of fiber-optic cable to meet growing demands for bandwidth. Companies will continue to replace private networks with public network bandwidth-on-demand. Although asynchronous transfer mode (ATM) is the transmission technology favored by many, its penetration will be slower than anticipated. Hybrid networks - e.g., a mix of ATM, frame relay, and fast Ethernet - may predominate, both as interim and long-term solutions, based on factors such as availability, interoperability, and cost. Telecommunications equipment and services prices will decrease further due to increased supply and more competition. Explosive Internet growth will continue, requiring additional backbone transmission capacity and enhanced protocols, but it is not clear who will fund the upgrade. Within ten years, space-based constellations of satellites in Low Earth orbit (LEO) will serve mobile users employing small, low-power terminals. 'Little LEO's' will provide packet transmission services and geo-position determination. 'Big LEO's' will function as global cellular telephone networks, with some planning to offer video and interactive multimedia services. Geosynchronous satellites also are proposed for mobile voice grade links and high-bandwidth services. NASA may benefit from resulting cost reductions in components, space hardware, launch services, and telecommunications services.

Crimi, Giles F.↗

Urban Air Quality Management at Low-Cost Using Micro Air Sensors: A Case Study From Accra, Ghana

Urban air quality management is dependent on the availability of local air pollution data. In many major urban centers of Africa, there is limited to non-existent information on air quality. This is gradually changing in part due to the increasing use of micro air sensors which have the potential to enable the generation of ground-based air quality data at fine scales for understanding local emission trends. Regional literature on the application of the high-resolution data for emission source identification in this region is limited. In this study a micro air sensor was co-located at the Physics Department, University of Ghana with a reference grade instrument to evaluate its performance for estimating PM2.5 pollution accurately at fine scales and the value of this data in identification of local sources and their behavior over time. For this study 15 weeks of data at hourly resolution with approximately 2500 data pairs are generated and analyzed (June 01, 2023, to September 15, 2023). For this time period a coefficient of determination (r 2 ) of 0.83 was generated with a mean absolute error (MAE) of 5.44 μgm -3 between the pre local calibration micro air sensor (i.e. out of box) and the reference-grade instrument. Following currently accepted best practice methods (see e.g., PAS4023) a domain specific (i.e. local) calibration factor was generated using a multi-linear regression model and when this factor is applied to the micro air sensor data, a reduction i.e., improvement in MAE to 1.43 μgm -3 was found. Daily variation was calculated, a receptor model was applied, and time series plots as a function of wind direction were generated, including PM2.5/PM10 ratio scatter and count plots to explore the utility of this observational approach for local source identification. The 3 data sets were compared (out of box, domain calibrated and reference-grade) and it was found that although there were variations in the data reported, source areas highlighted based on these data were similar, with input from local sources such as traffic emissions and biomass burning. As the temporal resolution of observational data associated with these micro air sensors is higher than for reference grade instruments (primarily due to costs and logistics limitations), they have the potential to provide insight into the complex, often hyper localized sources associated with urban areas, such as those found in major African cities.

Source apportionment↗

X-ray photoelectron spectroscopy study of radiofrequency-sputtered refractory compound steel interfaces

Radiofrequency sputtering was used to deposit Mo2C, Mo2B5, and MoSi2 coatings on 440C steel substrates. Both sputter etched and preoxidized substrates were used, and the films were deposited with and without a substrate bias of -300 V. The composition of the coatings was measured as a function of depth by X-ray photoelectron spectroscopy combined with argon ion etching. In the interfacial region there was evidence that bias produced a graded interface in Mo2B5 but not in Mo2C. Oxides of iron and of all film constituents except carbon were presented in all cases but the iron oxide concentration was higher and the layer thicker on the preoxidized substrates. The film and iron oxides were mixed in the MoSi2 and Mo2C films but layered in the Mo2B5 film. The presence of mixed oxides correlates with enhanced film adhesion.

Wheeler, D. R.↗

Support of NASA quality requirements by defense contract administration services regions

Defense Contract Administration Services Regions (DCASR) quality assurance personnel performing under NASA Letters of Delegation must work closely with the assigned technical representative of the NASA centers. It is realized that technical personnel from the NASA Centers cannot make on-site visits as frequently as they would like to. However, DCASR quality assurance personnel would know the assigned NASA technical representative and should contact him when problems arise. The technical representative is the expert on the hardware and should be consulted on any problem area. It is important that the DCASR quality assurance personnel recommend to the delegating NASA Center any new or improved methods of which they may be aware which would assist in achieving the desired quality and reliability in NASA hardware. NASA expects assignment of competent personnel in the Quality Assurance functional area and is not only buying the individual's technical skill, but also his experience. Suggestions by field personnel can many times up-grade the quality or the hardware.

Farrar, Hiram D.↗

Properties and Performance Attributes of Novel Co-extruded Polyolefin Battery Separator Materials: Electrical Properties - Part 2

As NASA prepares for its next era of manned spaceflight missions, advanced energy storage technologies are being developed and evaluated to address and enhance future mission needs and technical requirements. Cell-level components for advanced lithium-ion batteries possessing higher energy, more reliable performance and enhanced, inherent safety characteristics have been under development within the NASA infrastructure. A key component for safe and reliable cell performance is the cell separator, which separates the two energetic electrodes and functions to inhibit the occurrence of an internal short circuit but preserves an ionic current. Recently, a new generation of co-extruded separator films has been developed by ExxonMobil Chemical and introduced into their battery separator product portfolio. Several grades of this new separator material were evaluated with respect to dynamic mechanical properties and safety-related performance attributes, and the results of these evaluations were previously reported in "Part 1: Mechanical Properties" of this publication. This current paper presents safety-related performance results for these novel materials obtained by employing a complementary experimental methodology, which involved the analysis of separator impedance characteristics as a function of temperature. The experimental results from this study are discussed with respect to potential cell safety enhancement for future aerospace as well as for terrestrial energy storage needs, and they are compared with pertinent mechanical properties of these materials, as well as with current state-of-the practice separator materials.

Baldwin, Richard S.↗

Comparison of aortic and carotid baroreflex stimulus-response characteristics in humans

In order to characterize the stimulus-response relationships of the arterial, aortic, and carotid baroreflexes in mediating cardiac chronotropic function, we measured heart rate (HR) responses elicited by acute changes in mean arterial pressure (MAP) and carotid sinus pressure (CSP) in 11 healthy individuals. Arterial (aortic + carotid) baroreflex control of HR was quantified using ramped changes in MAP induced by bolus injection of phenylephrine (PE) and sodium nitroprusside (SN). To assess aortic-cardiac responses, neck pressure (NP) and suction (NS) were applied during PE and SN administration, respectively, to counter alterations in CSP thereby isolating the aortic baroreflex. Graded levels of NP and NS were delivered to the carotid sinus using a customized neck collar device to assess the carotid-cardiac baroreflex, independent of drug infusion. The operating characteristics of each reflex were determined from the logistic function of the elicited HR response to the induced change in MAP. The arterial pressures at which the threshold was located on the stimulus-response curves determined for the arterial, aortic and carotid baroreflexes were not significantly different (72+/-4, 67+/-3, and 72+/-4 mm Hg, respectively, P > 0.05). Similarly, the MAP at which the saturation of the reflex responses were elicited did not differ among the baroreflex arcs examined (98+/-3, 99+/-2, and 102+/-3 mm Hg, respectively). These data suggest that the baroreceptor populations studied operate over the same range of arterial pressures. This finding indicates each baroreflex functions as both an important anti-hypotensive and anti-hypertensive mechanism. In addition, this investigation describes a model of aortic baroreflex function in normal healthy humans, which may prove useful in identifying the origin of baroreflex dysfunction in disease- and training-induced conditions.

Non-NASA Center↗