Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Focusing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Rethinking radiation effects in materials science using the plasma-focused ion beam

This work demonstrates the viability of using a plasma-focused ion beam (PFIB) as a new platform to carry out radiation effects studies in solids. While materials subjected to irradiation in either nuclear reactors or energetic particle accelerators experience limitations with respect to inaccuracies in both flux measurements and lack of precise control of irradiation areas, we demonstrate a new irradiation technique that allows the exposure of a single specimen in multiple areas, at multiple doses, and in site-specific dependencies - all with flux variations on the order of only 1%. This versatile technique also allows materials to be exposed to significantly higher irradiation dose rates than conventional accelerators. To validate the new methodology, we selected the classical example of ion-beam-induced amorphization of pure single-crystal Si. By pioneering the use of the PFIB for radiation effects studies in materials science, we were able to exploit, in both micro- and nanometer-sized detail, the differences in electron image contrast arising from crystalline versus amorphous solid-state phases in classical semiconductors subjected to irradiation, thus providing new insights on amorphization mechanisms. This methodology opens new research frontiers at the fringe of materials science with promising applications beyond the scope of materials at extremes such as in nanopatterning, nanodevices and nanoarchitectonics.

36 MATERIALS SCIENCE↗

Focused ion beam deposited carbon-platinum nanowires for cryogenic resistive thermometry

The study of thermal effects, both classical and quantum, at cryogenic temperatures requires the use of on-chip, local, high-sensitivity thermometry. Carbon-platinum composites fabricated using focused ion beam (FIB) assisted deposition form a granular structure which is shown in this study to be uniquely suited for this application. Carbon-platinum thermometers deposited using a 24 pA ion beam current have high sensitivities below 1 K, comparable to the best cryogenic thermometers. In addition, these thermometers can be accurately placed to within 10s of nanometers on the chip using a mask-free process. Furthermore, they also have a weak magnetic field dependence, 3% change in resistance with applied magnetic fields from 0 to 8 T. Finally, these thermometers are integrable into a variety of nanoscale devices due to the existing wide spread use of FIB.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Focused ion beam milling of polycrystalline diamond

Focused ion beam (FIB) technology has a large potential for precise milling of ultrahard materials such as diamond. However, studies of the sputtering of diamond with ion species and energies relevant to the FIB technology are scarce. Here, we report a systematic study of the sputtering of polycrystalline diamond surfaces with ion beams in a wide range of ion energies (2 - 30 keV), incident beam angles (0 - 80°), and ion masses (N, O, Ar, and Xe). Results show that the sputter yield is relatively insensitive to ion energy but strongly depends on the ion species and incident beam angles. Bombardment with O ions results in sputter yields that are significantly larger than ballistic predictions due to chemical etching effects. Characteristic surface ripples develop for oblique beam incidence angle irradiation. The critical beam tilt angle for the onset of ripple formation and the wavelength of the ripples depend on ion species and energies. Ripples appear to suppress ion reflection at high beam tilt angles and, hence, a peak in the sputter yield angular dependence. In conclusion, these results have direct implications for the development of process parameter maps for high-precision ion-beam milling of diamond.

36 MATERIALS SCIENCE↗

Linear beam stability in periodic focusing systems: Krein signature and band structure

The general question of how a beam becomes unstable has been one of the fundamental research topics among beam and accelerator physicists for several decades. In this study, we revisited the general problem of linear beam stability in periodic focusing systems by applying the concepts of Krein signature and band structure. We numerically calculated the eigenvalues and other associated characteristics of one-period maps, and discussed the stability properties of single-particle motions with skew quadrupoles and envelope perturbations in high-intensity beams on an equal footing. In particular, an application of the Krein theory to envelope instability analysis was newly attempted in this study. Finally, the appearance of instabilities is interpreted as the result of the collision between eigenmodes of opposite Krein signatures and the formation of a band gap.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionic Liquid Gating of SrTiO 3 Lamellas Fabricated with a Focused Ion Beam

Here, in this work, we combine two previously incompatible techniques for defining electronic devices: shaping three-dimensional crystals by focused ion beam (FIB), and two-dimensional electrostatic accumulation of charge carriers. The principal challenge for this integration is nanometer-scale surface damage inherent to any FIB-based fabrication. We address this by using a sacrificial protective layer to preserve a selected pristine surface. The test case presented here is accumulation of 2D carriers by ionic liquid gating at the surface of a micron-scale SrTiO 3 lamella. Preservation of surface quality is reflected in superconductivity of the accumulated carriers. This technique opens new avenues for realizing electrostatic charge tuning in materials that are not available as large or exfoliatable single crystals, and for patterning the geometry of the accumulated carriers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Structural Changes in YBa 2 Cu 3 O 7 Thin Films Modified with He + -Focused Ion Beam for High-Temperature Superconductive Nanoelectronics

Irradiation of high-temperature superconductor YBa 2 Cu 3 O 7 (YBCO) with high-energy He + ions is known to cause structural changes in the YBCO film, decreasing the critical temperature T C and finally leading to a superconductor-to-insulator transition. Here, this allows one to pattern narrow insulating regions with a focused ion beam (FIB) and thus fabricate nanoscale Josephson junctions on YBCO films. Moreover, such ion irradiation is known to cause structural changes in the YBCO film. However, details of how these structural changes occur in nanoscale devices produced by FIB remain unknown. Using nanofocus X-ray diffraction, we study the changes in the YBCO crystal lattice and investigate how the nature of these changes depends on the size of the irradiated regions. These data provide an important understanding of how oxide superconductors can be tailored at the nanometer scale for various applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-Dimensional Free Gas Flow Focuses Basin-Wide Microbial Methane to Concentrated Methane Hydrate Reservoirs in Geological System

Here, we present a systematic model that links the generation, migration, phase partitioning, and accumulation of methane into a closed loop as the sediment is deposited from the seafloor and buried through the base of hydrate stability zone (BHSZ). In our model, methane is generated by biodegradation of organic carbon in muds. Hydrate does not form and methane is not trapped until a coarse-grained layer is deposited, because the small pores prevent hydrate formation in muds. Instead, methane diffuses into sands/silts where methane solidifies into hydrate. As hydrate-bearing sands/silts pass through the BHSZ during sediment burial, methane hydrate dissociates, and releases free gas. The released and the newly generated free gas below the BHSZ concentrates into a vertical/dipping zone with low capillary entry pressure and high permeability and flows upward driven its buoyancy. When free gas reaches the hydrate stability zone (HSZ), capillary forces drive free gas to flow laterally, preferentially enter sands/silts, feed hydrate growth, and elevate hydrate saturation. With three-dimensional focused free gas flow, microbial methane that is generated from a much larger fetch area of the entire basin, both above and below the BHSZ, is concentrated into coarse-grained layers at structural closures for hydrate formation. Our model illustrates how geological evolution, microbial methane generation, and gas flow by buoyancy couple to generate concentrated hydrate deposits in geological system. These insights can be used to explore for high-concentration methane hydrate and are important for understanding the methane budget and carbon cycle under the seafloor.

58 GEOSCIENCES↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

Design and evaluation of an open-source, conformable skin-cooling system for body magnetic resonance guided focused ultrasound treatments

Magnetic resonance guided focused ultrasound (MRgFUS) treatment of tumors uses inter-sonication delays to allow heat to dissipate from the skin and other near-field tissues. Despite inter-sonication delays, treatment of tumors close to the skin risks skin burns. This work has designed and evaluated an open-source, conformable, skin-cooling system for body MRgFUS treatments to reduce skin burns and enable ablation closer to the skin. A MR-compatible skin cooling system is described that features a conformable skin-cooling pad assembly with feedback control allowing continuous flow and pressure maintenance during the procedure. System performance was evaluated with hydrophone, phantom and in vivo porcine studies. Sonications were performed 10 and 5 mm from the skin surface under both control and forced convective skin-cooling conditions. 3D MR temperature imaging was acquired in real time and the accumulated thermal dose volume was measured. Gross analysis of the skin post-sonication was further performed. Device conformability was demonstrated at several body locations. Hydrophone studies demonstrated no beam aberration, but a 5–12% reduction of the peak pressure due to the presence of the skin-cooling pad assembly in the acoustic near field. Phantom evaluation demonstrated there is no MR temperature imaging precision reduction or any other artifacts present due to the coolant flow during MRgFUS sonication. The porcine studies demonstrated skin burns were reduced in size or eliminated when compared to the control condition. An open-source design of an MRgFUS active skin cooling system demonstrates device conformability with a reduction of skin burns while ablating superficial tissues.

60 APPLIED LIFE SCIENCES↗

Plasma Focused Ion Beam Milling of High-Aspect-Ratio Holes in Diamond

Plasma focused ion beam (PFIB) technology has a great potential for applications requiring rapid micro-machining of high-aspect-ratio features. Here, we use 30-keV Ar, Xe, and O 2 ion beams to study PFIB milling of high-aspect-ratio circular holes in polycrystalline diamond. Our results show that Xe and O 2 ion beams have the highest milling efficiency for low-aspect-ratio and high-aspect-ratio hole milling, respectively. Each ion beam species produces holes with its characteristic shape and wall surface morphology. In conclusion, based on these results, we demonstrate a “hybrid” hole milled in a two-step process with Xe and O 2 ion beams with the geometry and wall morphology attractive for the attachment of a fuel fill tube to the inertial confinement fusion capsule.

ICF targets↗

Electronic angle focusing for neutron time-of-flight powder diffractometers

A neutron time-of-flight (TOF) powder diffractometer with a continuous wide-angle array of detectors can be electronically focused to make a single pseudo-constant wavelength diffraction pattern, thus facilitating angle-dependent intensity corrections. The resulting powder diffraction peak profiles are affected by the neutron source emission profile and resemble the function currently used for TOF diffraction.

electronic focusing↗

Mirror-centered representation of a focusing hyperbolic mirror for X-ray beamlines

Conic sections are commonly used in reflective X-ray optics. Hyperbolic mirrors can focus a converging light source and are frequently paired with elliptical or parabolic mirrors in Wolter type configurations. This paper derives the closed-form expression for a mirror-centered hyperbolic shape, with zero-slope at the origin. Combined with the slope and curvature, such an expression facilitates metrology, manufacturing and mirror-bending calculations. Previous works consider ellipses, parabolas, magnifying hyperbolas or employ lengthy approximations. Here, the exact shape function is given in terms of the mirror incidence angle and the source and image distances.

47 OTHER INSTRUMENTATION↗

Comparison of Single-Event Transients in an Epitaxial Silicon Diode Resulting from Heavy Ion-, Focused X-Ray-, and Pulsed Laser-Induced Charge Generation

Heavy ion, focused x-ray, and pulsed laser single event transient experiments are performed on a silicon epitaxial diode. Collected charge, transient rise times, and transient fall times are calculated and compared between the different sources. It is observed that these transient shape characteristics depend on the source (ion, x-ray, or laser), even when similar amounts of charge are generated. Finally, the observed differences are examined and explained in terms of basic charge collection mechanisms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lithium source for focused ion beam implantation and analysis

In this work, we present a new Li source for focused ion beam applications. Based on an AuSi eutectic alloy, Li is added as an impurity to minimize effects from degradation when exposed to air. We show the source is stable over the course of an hour and spot sizes ≲10 nm can be achieved. The Li beam can achieve hundreds of nanometer ranges in semiconductors with minimal damage being generated along the path length. The source performance is evaluated through a high-resolution ion beam induced charge collection experiment on an Si-based detector. Further application of the source for ion beam analysis is numerically explored; the example investigated is based on probing a semiconductor heterostructure through a Rutherford backscattering experiment, where the Li beam can reveal information that is inaccessible with either low energy or high energy He projectiles used as probes.

36 MATERIALS SCIENCE↗

Repair strategy for fused silica wedged focus lens with high-density filamentary damage

The National Ignition Facility (NIF) is intentionally operated with the final fused silica glass (SiO2) optics exposed to fluences and intensities with the potential to induce damage that will grow with additional laser exposure. Therefore, the NIF operates a recycle loop to refurbish final optics by mitigating any initiated surface damage to arrest its growth. However, the morphology of filamentary damage, caused by local self-focusing in the bulk of a silica optic, adds complexity to optics mitigation and provides a limitation to optic reusability. Here, we evaluate techniques for mitigating isolated and clustered filamentary damage. Optical microscopy before and after installation on NIF was used to determine the efficacy of filamentary mitigation after a series of high fluence and intensity laser exposures. The challenges and success rate of the methods are compared for various filamentary damage mitigation strategies.

National Ignition Facility↗

Station 6: Focused Experiments

This station, the second of four on the inside portion of the exhibit, explains focused experiments at Los Alamos. The station consists of a title monitor, main monitor, pushbuton monitor, and tabletop.

99 GENERAL AND MISCELLANEOUS↗

Automation of Laser Plasma Focused Ion Beam Microscopy for Next-Gen Energy Materials

Automation can revolutionize the use of ultrafast laser ablation and plasma-focused ion beam (PFIB) techniques for high-throughput, reproducible cross-sectioning and various sample preparation in materials characterization. As these methods become essential for analyzing complex energy materials and next-generation devices, efficient, standardized workflows are needed to minimize variability and enhance precision. This work highlights our advancements in developing automated processes for sample preparation that integrates machine learning, workflow optimization, and large-scale data acquisition to improve efficiency and scalability in applications such as electrolyzers, photovoltaic cells, and microelectronics. To streamline cross-sectioning and lamella fabrication, we have implemented fully automated workflows that standardize laser ablation and PFIB milling sequences. These workflows incorporate pre-programmed protocols for material removal, alignment, and thinning, reducing user intervention and ensuring consistency across different sample types. Machine learning algorithms further enhance automation by predicting optimal milling strategies and adapting parameters based on material properties and sectioning requirements. This approach significantly improves throughput while maintaining the structural integrity of prepared samples for high-resolution imaging and analysis, including transmission electron microscopy. Beyond sample preparation, our automation platform enables the acquisition of large, high-resolution datasets through serial sectioning, image alignment, and 3D reconstruction. These automated routines facilitate multi-scale characterization, capturing structural and compositional details from the nanoscale to the device level. By reducing variability and increasing efficiency, our automated approach enhances defect analysis, failure diagnostics, and process optimization, accelerating advancements in materials research and device engineering.

36 MATERIALS SCIENCE↗