Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Focusing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The theory of ionospheric focused heating

Ionospheric modification by high power radio waves and by chemical releases are combined in a theoretical study of ionospheric focused heating. The release of materials which promote electron-ion recombination creates a hole in the bottomside ionosphere. The ionospheric hole focuses high power radio waves from a ground-based transmitter to give a 20 dB or greater enhancement in power density. The intense radio beam excites atomic oxygen by collisions with accelerated electrons. Airglow from the excited oxygen provides a visible trace of the focused beam. The large increase in the intensity of the radio beam stimulates new wave-plasma interactions. Numerical simulations show that the threshold for the two-plasmon decay instability is exceeded. The interaction of the pump electromagnetic wave with the backward plasmon produces a scattered electromagnetic wave at 3/2 the pump frequency. The scattered wave provides a unique signature of the two-plasmon decay process for ground-based detection.

Bernhardt, P. A.↗

Quality control of murine monoclonal antibodies using isoelectric focusing affinity immunoblot analysis

The quality control of murine hybridoma secretory products has been performed using two approaches for isoelectric focusing affinity immunoblot analysis: (1) a method in which antigen-coated nitrocellulose is placed on top of an acrylamide gel containing isoelectrically focused ascites to bind the antigen specific monoclonal antibody; and (2) a method in which focused ascite proteins were passively blotted onto nitrocellulose and specific monoclonal antibodies were detected with enzyme-conjugated antigen. Analysis by both methods of batches of ascites containing antihuman IgG antibodies that were produced by six hybridomas permitted effective monitoring of immunoreactive antibodies for pI microheterogeneity.

Hamilton, Robert G.↗

A spaceborne optical interferometer: The JPL CSI mission focus

The JPL Control Structure Interaction (CSI) program is part of the larger NASA-wide CSI program. Within this larger context, the JPL CSI program will emphasize technology for systems that demand micron or sub-micron level control, so-called Micro-Precision Controlled Structures (u-PCS). The development of such technology will make it practical to fly missions with large optical or large precision antenna systems. In keeping with the focused nature of the desired technology, the JPL approach is to identify a focus mission, develop the focus mission CSI system design to a preliminary level, and then use this design to drive out requirements for CSI technology development in the design and analysis, ground test bed, and flight experiment areas.

Laskin, R. A.↗

Laser performance, thermal focusing and depolarization effects in Nd:Cr:GSGG and Nd:YAG

The laser performance of Nd:Cr:GSGG and Nd:YAG was investigated and compared for laser efficiency, thermal focusing, and depolarization effects. Laser efficiency was studied for Nd:Cr:GSGG and Nd:YAG under similar conditions. Laser efficiency was measured as a function of electrical energy and output mirror reflectivity. Maximum laser efficiency was calculated by determining the losses in the laser cavity. Thermal focusing and birefringence loss of Nd:Cr:GSGG and Nd:YAG have been examined by varying the average pump power. The average pump power changed by adjusting both the energy per pulse and the pulse-repetition frequency. Substantial thermal focusing differences for Nd:Cr:GSGG are explained.

Williams-Byrd, Julie A.↗

Differential spot-size focus servo

We describe performance of a differential spot-size (wax-wane) focus servo. Crosstalk from the tracks are analyzed in the single detector and differential focus circuits. Magnitude of the crosstalk is reduced by a factor of three in the differential circuit. A false focus-error signal (FES) is present when the spot crosses sector marks at an angle.

Milster, T. D.↗

Focused transport of energetic particles along magnetic field lines draped around a coronal mass ejection

Evidence is presented for focused transport of energetic particles along magnetic field lines draped around a coronal mass ejection. This evidence was obtained with the University of Maryland/Max-Planck-Institute experiment on the ISEE-3 spacecraft during the decay phase of the June 6, 1979, solar particle event. During the early portion of the decay phase of this event, interplanetary magnetic field lines were apparently draped around a coronal mass ejection, leading to a small focusing length on the western flank where ISEE 3 was located. A period of very slow decrease of particle intensity was observed, along with large sunward anisotropy in the solar wind frame, which is inconsistent with predictions of the standard Fokker-Planck equation models for diffusive transport. It was found possible to fit the observations, assuming that focused transport dominates and that the particle pitch angle scattering is isotropic.

Tan, L. C.↗

Soft X Ray Telescope (SXT) focus error analysis

The analysis performed on the soft x-ray telescope (SXT) to determine the correct thickness of the spacer to position the CCD camera at the best focus of the telescope and to determine the maximum uncertainty in this focus position due to a number of metrology and experimental errors, and thermal, and humidity effects is presented. This type of analysis has been performed by the SXT prime contractor, Lockheed Palo Alto Research Lab (LPARL). The SXT project office at MSFC formed an independent team of experts to review the LPARL work, and verify the analysis performed by them. Based on the recommendation of this team, the project office will make a decision if an end to end focus test is required for the SXT prior to launch. The metrology and experimental data, and the spreadsheets provided by LPARL are used at the basis of the analysis presented. The data entries in these spreadsheets have been verified as far as feasible, and the format of the spreadsheets has been improved to make these easier to understand. The results obtained from this analysis are very close to the results obtained by LPARL. However, due to the lack of organized documentation the analysis uncovered a few areas of possibly erroneous metrology data, which may affect the results obtained by this analytical approach.

Ahmad, Anees↗

A sharp-focusing schlieren optical deflectometer

A new instrument capable of localized, nonintrusive turbulence measurements is developed by combining a focusing schlieren system with an optical deflectometer. This instrument records the fluctuating light intensity at a point in the focused schlieren image. Its capability is verified by making benchmark measurements of Kelvin-Helmholtz vortices produced in a low-speed axisymmetric mixing layer. The sharp-focusing effect is demonstrated both visually and quantitatively. The results show that the instrument is capable of optical turbulence measurements within a 4 mm depth-of-field.

Alvi, F. S.↗

Mechanical and thermal disturbances of the PSR Moderate Focus-Mission Structure

The primary objective of this paper is to evaluate the optical pointing performance of the PSR Moderate Focus-Mission Structure when subjected to both mechanical and thermal disturbances. The mechanical disturbances are based on secondary mirror chopping. Results indicate that dynamic responses of the primary reflector and the secondary reflector subjected to chopping disturbances of the secondary reflector about its center of mass are within the figure maintenance control capabilities. The effects of modal damping, truss-type secondary support, interface boundary constraints, and alternate configurations, are also evaluated in the analysis. Thermal distortions of the structure were also evaluated based on the on-orbit temperature profiles derived from the submillimeter telescope missions. Results from thermal deformation analysis indicate that figure initialization control is needed for the PSR Moderate Focus-Mission. However, a figure maintenance system may not be required if adequate thermal isolation is incorporated into the support truss design for the PSR Moderate Focus-Mission Structure.

Shih, Choon-Foo↗

Comparison of ring-focus image profile with predictions for the AXAF VETA-I test

The X-ray test of the largest pair of nearly cylindrical mirrors for the Advanced X-ray Astrophysics Facility (AXAF) was completed in October 1991 at Marshall Space Flight Center. The test assembly was named the Verification Engineering Test Article I (VETA-I). The ring-focus portion of the test measured the imaging quality of azimuthal sections of VETA-I. This gives information about the core of the on-orbit image. The finite source distance, VETA-I mirror spacing, and VETA-I structural deformation caused the core of the image to be spread over a diameter of nearly 4 arc seconds at the VETA-I overall focus. The results of a preliminary analysis of the ring-focus data and the implications for the on-orbit image of the telescope are discussed. An upper limit for the on-orbit encircled-energy fraction at 1 arc second diameter was determined to be 0.82 at 0.277 keV X-ray energy. This assumes that the bottoms of the mirrors in the VETA-I arrangement are representative of the mirror surfaces and that the on-orbit system would be aligned using a combination of preliminary measurements and predictions for the mirror surface shapes.

Zissa, David E.↗

Techniques For Focusing In Zone Electrophoresis

In two techniques for focusing in zone electrophoresis, force of applied electrical field in each charged particle balanced by restoring force of electro-osmosis. Two techniques: velocity-gradient focusing (VGF), suitable for rectangular electrophoresis chambers; and field-gradient focusing (FGF), suitable for step-shaped electrophoresis chambers.

Sharnez, Rizwan↗

Attention focusing and anomaly detection in systems monitoring

Any attempt to introduce automation into the monitoring of complex physical systems must start from a robust anomaly detection capability. This task is far from straightforward, for a single definition of what constitutes an anomaly is difficult to come by. In addition, to make the monitoring process efficient, and to avoid the potential for information overload on human operators, attention focusing must also be addressed. When an anomaly occurs, more often than not several sensors are affected, and the partially redundant information they provide can be confusing, particularly in a crisis situation where a response is needed quickly. The focus of this paper is a new technique for attention focusing. The technique involves reasoning about the distance between two frequency distributions, and is used to detect both anomalous system parameters and 'broken' causal dependencies. These two forms of information together isolate the locus of anomalous behavior in the system being monitored.

Doyle, Richard J.↗

Program Models A Laser Beam Focused In An Aerosol Spray

Monte Carlo analysis performed on packets of light. Program for Analysis of Laser Beam Focused Within Aerosol Spray (FLSPRY) developed for theoretical analysis of propagation of laser pulse optically focused within aerosol spray. Applied for example, to analyze laser ignition arrangement in which focused laser pulse used to ignite liquid aerosol fuel spray. Scattering and absorption of laser light by individual aerosol droplets evaluated by use of electromagnetic Lorenz-Mie theory. Written in FORTRAN 77 for both UNIX-based computers and DEC VAX-series computers. VAX version of program (LEW-16051). UNIX version (LEW-16065).

Barton, J. P.↗

Copper Gas Diffusers For Purging Line-Focus Laser Welds

Modified flow diffusers built for inert-gas purging of welds made with 5-kW CO(2) lasers operating with line-focus optics in conduction mode instead of with point-focus optics in customary keyhole mode. Diffusers made of copper components brazed together, robust enough to withstand strong reflections of line-focused laser energy.

Fonteyne, Steve L.↗

USAF Flight Test Investigation of Focused Sonic Booms: Project Have Bears

Supersonic operations from military aircraft generate sonic booms that can affect people, animals and structures. A substantial experimental data base exists on sonic booms for aircraft in steady flight and confidence in the predictive techniques has been established. All the focus sonic boom data that are in existence today were collected during the 60's and 70's as part of the information base to the US Supersonic Transport program and the French Jericho studies for the Concorde. These experiments formed the data base to develop sonic boom propagation and prediction theories for focusing. There is a renewed interest in high-speed transports for civilian application. Moreover, today's fighter aircraft have better performance capabilities, and supersonic flights ars more common during air combat maneuvers. Most of the existing data on focus booms are related to high-speed civil operations such as transitional linear accelerations and mild turns. However, military aircraft operating in training areas perform more drastic maneuvers such as dives and high-g turns. An update and confirmation of USAF prediction capabilities is required to demonstrate the ability to predict and control sonic boom impacts, especially those produced by air combat maneuvers.

Downing, Micah↗

Using High Frequency Focused Water-Coupled Ultrasound for 3-D Surface Depression Profiling

Surface topography is an important variable in the performance of many industrial components and is normally measured with diamond-tip profilometry over a small area or using optical scattering methods for larger area measurement. A prior study was performed demonstrating that focused air-coupled ultrasound at 1 MHz was capable of profiling surfaces with 25 micron depth resolution and 400 micron lateral resolution over a 1.4 mm depth range. In this article, the question of whether higher-frequency focused water-coupled ultrasound can improve on these specifications is addressed. 10 and 25 MHz focused ultrasonic transducers were employed in the water-coupled mode. Time-of-flight images of the sample surface were acquired and converted to depth / surface profile images using the simple relation (d = V*t/2) between distance (d), time-of-flight (t), and the velocity of sound in water (V). Results are compared for the two frequencies used and with those from the 1 MHz air-coupled configuration.

Roth, Don J.↗

Adjustable Focus Optical Correction Lens (AFOCL)

This report describes the activities and accomplishments along with the status of the characterization of a PLZT-based Adjustable Focus Optical Correction Lens (AFOCL) test device. The activities described in this report were undertaken by members of the Center for Applied Optics (CAO) at the University of Alabama in Huntsville (UAH) under NASA Contract NAS8-00188. The effort was led by Dr. Bruce Peters as the Principal Investigator and supported by Dr. Patrick Reardon, Ms. Deborah Bailey, and graduate student Mr. Jeremy Wong. The activities outlined for the first year of the contract were to identify vendors and procure a test device along with performing the initial optical characterization of the test device. This activity has been successfully executed and test results are available and preliminary information was published at the SPIE Photonics West Conference in San Jose, January 2001. The paper, "Preliminary investigation of an active PLZT lens," was well received and generated response with several questions from the audience. A PLZT test device has been commercially procured from an outside vendor: The University of California in San Diego (UCSD) in partnership with New Interconnect Packaging Technologies (NIPT) Inc. The device has been subjected to several tests to characterize the optical performance of the device at wavelengths of interest. The goal was to evaluate the AFOCL similar to a conventional lens and measure any optical aberrations present due to the PLZT material as a deviation in the size of the diffraction limited spot (blur), the presence of diffracted energy into higher orders surrounding the focused spot (a variation in Strehl), and/or a variation or spread in the location of the focused energy away from the optical axis (a bias towards optical wedge, spherical, comma, or other higher order aberrations). While data has been collected indicative of the imaging quality of the AFOCL test device, it was not possible to fully characterize the optical performance of the AFOCL alone because there were significant optical distortions due to fabrication related issues.

Peters, Bruce R.↗

Electrophoretic Focusing

Electrophoretic focusing is a new method of continuous flow electrophoresis that introduces precision flow control to achieve high resolution separations. The electric field is applied perpendicular to an incoming sample lamina and buffer but also perpendicular to the broad faces of the thin rectangular chamber. A uniform fluid cross-flow then enters and exits the separation chamber through the same broad faces which are porous. A balance is achieved by adjusting either the electric field or the cross-flow so the desired sample fraction with its specific migration velocity encounters an opposing flow of the same velocity. Applying an electric field transverse to the incoming sample lamina and opposing this field with a carefully configured buffer flow, a sample constituent can be selected and focused into a narrow stream for subsequent analysis. Monotonically changing either electric field or buffer cross-flow will yield a scan of all constituents of the sample. Stopping the scan increases the collection time for minor constituents to improve their analysis. Using the high voltage gradients and/or cross-flow to rapidly deflect extraneous sample through the porous screens and into either of the side (purge) chambers, the selected sample is focused in the center plane of the separation chamber and collected without contact or interaction with the separation chamber walls. Results will be presented on the separation of a range of materials including dyes, proteins, and monodisperse polystyrene latexes. Sources of sample dispersion inherent in other electrokinetic techniques will be shown to be negligible for a variety of sample concentrations, buffer properties and operating conditions.

Snyder, Robert S.↗